Loading...
HomeMy WebLinkAbout055-A2-PLANS BLDG A_HIGHLAND-A2.2a1 23 4 5 54321 29 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 30 LMNOPQZAARSTWYZAAABCDEFGHIJKYXWUTSRQPONMLKJIHGFEDCBAUXVV72240100ACCORDSHOWER STALLVIKRELL72240100ACCORDSHOWER STALLVIKRELL 72240100ACCORDSHOWER STALLVIKRELL72240100ACCORDSHOWER STALLVIKRELL 72240100ACCORDSHOWER STALLVIKRELL 72240100ACCORDSHOWER STALLVIKRELL72240100ACCORDSHOWER STALLVIKRELL VIKRELLSHOWER STALLACCORD72240100 (U3-2 B)3 BDRM / 2 BATH UNIT A201 (U2-2 B)2 BDRM / 2 BATH UNIT A203 (U1-1 B)1 BDRM / 1 BATH UNIT A207 (U3-2 B)3 BDRM / 2 BATH UNIT A209 (U3-2 B) 3 BDRM / 2 BATH UNIT A202 (U2-2 B) 2 BDRM / 2 BATH UNIT A204 (U2-2 B) 2 BDRM / 2 BATH UNIT A206 (U1-1 B) 1 BDRM / 1 BATH UNIT A208 (U1-1 B) 1 BDRM / 1 BATH UNIT A210 (U1-1 B)1 BDRM / 1 BATH UNIT A213 (U2-2 B)2 BDRM / 2 BATH UNIT A215 (U2-2 B) 2 BDRM / 2 BATH UNIT A217 (U3-2 B)3 BDRM / 2 BATH UNIT A219 (U1-1 B)1 BDRM / 1 BATH UNIT A214 (U2-2 B)2 BDRM / 2 BATH UNIT A216 (U2-2 B) 2 BDRM / 2 BATH UNIT A218 (U3-2 B)3 BDRM / 2 BATH UNIT A120 (U1-1 B)1 BDRM / 1 BATH UNIT A212 (U3-2 B)3 BDRM / 2 BATH UNIT A211 STAIR 1 S201 STAIR 2 S202 CORRIDOR C201 CORRIDOR C202 CORRIDOR C205 CORRIDOR C206 ELEVATOR E102 CLOSET JANITOR C203 CLOSET MAINT. C204 (U2-2 ACC.)2 BDRM / 2 BATH UNIT A205 A2.2a SECOND LEVEL FLOOR PLAN - BUILDING A TAGS 25.104edinc Job #: 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design + architecture inc THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. INFORMAL SET:SITE PLAN PACKET #2 - 10/24/20252025 ENCOMPASS DESIGN INC.C A NEW KAMAKA HOUSING DEVELOPMENT:HIGHLANDS APARTMENTSBOZEMAN, MONTANA05/09/25 SITE PLAN PACKET #1:08/01/25 SITE PLAN PACKET #2:10/24/25 SCALE :1 Second Level Floor Plan - Building A 3/32" = 1'-0" N 30 MIN REQUIRED FIRE RATING CEILING FAN, SEE ELECTRICAL # ALT SEE COVER SHEET FOR INFORMATION ON ALTERNATE CPT#RF FLOORING DESIGNATION, SEE FINISH NOTES LIGHTING, SEE ELECTRICAL ROOM NAME ROOM NUMBER DOOR TAG - SEE SCHEDULE ON A0.5 WINDOW TAG - SEE SCHEDULE ON A0.5 INTERIOR WALL TYPES - SEE A0.2 FOR WALL ASSEMBLY SECTION CUT GRID LINE GUARD RAIL, SEE DETAILS ON A8.4 EGRESS WINDOW, SEE WINDOW SCHEDULE, NOTED ON CODE PLANS(E) TEMPERED GLASS, SEE WINDOW SCHEDULE(T) EXTERIOR WALL - SEE A0.2 FOR WALL ASSEMBLY, SEE ELEVATIONS FOR SIDING TYPE 24" DEEP SHELF W/ CLOSET ROD, SEE SPEC. FD FLOOR DRAIN, SEE MECHANICAL AND DETAIL 8/A7.1b HATCH DESIGNATION DOWN SPOUT, SEE ROOF PLANDS HOSE BIB, SEE MECHANICALHB CONCRETE RAIN CHAIN, SEE ROOF PLANRC 1 # A#.# LANDSCAPING, SEE CIVIL AWNING BELOW, SEE DETAILS ON A8.6 AND STRUCTURAL WOOD DECKING NO ROOF PENETRATIONS SEE CODE WALL SECTIONS 30 YEAR ARCHITECTURAL ASPHALT SHINGLES - SEE ARCH ROOF PLAN XXX XXX LEGEND - FLOOR PLANS I-# X ROOM2 ROOM1 RM# N XXX S W E D-100 E-# INTERIOR ELEVATION NUMBER SHEET NUMBER DETAIL REFERENCE LOCATION DETAIL DRAWING NUMBER DETAIL SHEET NUMBER CLOTHES WASHER & DRYER LOCATIONS. PROVIDE EXHAUST VENTING AS REQ'D BY MANUF. DRYER: PROVIDE MIN 26 GA DUCT, SEE MECHANICAL WASHER: PROVIDE A FLOOR DRAIN (BY CODE) AND PROVIDE HOOKUPS (CSCI) ELECTRICAL PANEL, SEE ELECTRICAL 20X30 ATTIC ACCESS, SEE DETAIL 1/A7.1c, COORDINATE W/ STRUCTURAL GENERAL NOTES -FLOOR PLANS A.USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. B.DIMENSIONS ARE FROM FACE OF STUD AT NEW WALLS. SEE WALL TYPES FOR ADDITIONAL WALL ASSEMBLY INFORMATION. C.SET DOOR ROUGH OPENINGS 6" FROM F.O.S., TYP. U.N.O. CENTER CLOSET DOOR ALONG LENGTH OF CLOSET. D.SEE OVERALL PLANS FOR ADDITIONAL DIMENSIONS. E.SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING & SHEAR WALLS. F.COORDINATE ALL COLUMN LOCATIONS AND SIZES WITH STRUCTURAL DRAWINGS. G.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE RODS, ETC. BACKING TO BE INCLUDED IN ALL UNITS ON ALL FLOORS TO COMPLY WITH "ADA" ADAPTABILITY. REFER TO INTERIOR ELEVATIONS FOR FURTHER INFORMATION REGARDING TOILET & TUB/SHOWER BLOCKING, TYPICAL. H.SEE RCP, ELECTRICAL & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS & LIGHTING. I.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS. J.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR FLOOR SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS. K.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE ADDITIONAL LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH, UNIFORM FINISHED SURFACE FOR ENTIRE LENGTH OF WALL. L.SEE CODE SHEET FOR FURTHER REQUIREMENTS. M.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ OWNER. N.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP. O.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER HEATER ROOMS, ETC). USE ADDITIONAL LAYERS OF GWB AS REQ'D TO NOT INTERRUPT RATINGS OF WALLS. P.SEE A5.1 & A5.2 FOR ALL ACCESSIBLE DETAILS & TYPICAL CASEWORK DIMENSIONS FOR THIS FLOOR. Q.SHELF MOUNTING HEIGHTS TO BE MAX 48" A.F.F. IN THE CODE REQUIRED ADA ACCESSIBLE UNITS AND 64" A.F.F. IN ALL OTHER UNITS. SEE ACCESSIBLE MOUNTING HEIGHTS ON A5's. R.SEE A5's FOR BATHROOM AND KITCHEN INTERIOR ELEVATIONS. S.SEE A7's FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS. T.SEE A7's FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS. U.SEE A8's FOR DOOR AND WINDOW DETAILS. V.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES. W.PROVIDE P.T. PLATES AT ALL WALLS ADJACENT TO CEMENTIOUS MATERIAL. X.CONTRACTOR TO VERIFY IN EACH UNIT THAT THE CABINETRY LENGTH IS COORDINATED AND VERIFIED WITH THE REFRIGERATOR REQUIRED CLEAR SPACE PER THE INSTALLATION INSTRUCTIONS. Y.VERIFY BATHTUB/SHOWER HEAD WALL LOCATIONS WITH ARCH & MECH. Z.FLOOR DRAIN REQUIRED AT ALL LAUNDRY NOOKS AND WATER HEATER CLOSETS. SEE MECH. AA.PROVIDE GARBAGE DISPOSALS @ ALL KITCHEN SINKS. AB.USE ¼” DURAROCK (OR APPROVED WATER RESISTANT CEMENT BOARD) IN ALL BATHROOMS, LAUNDRY ROOMS AND WATER HEATER ROOMS. AT RATED COMMON WALLS BEHIND TUB OR SHOWER INSERT PROVIDE 5/8" TYPE 'X' IN FULL, FIRE TAPE PRE TUB / SHOWER INSTALL. AC.CARBON MONOXIDE DETECTORS REQUIRED IN EACH UNIT, COORDINATE WITH ELECTRICAL. SEE SPECS. AD.PORTABLE FIRE EXTINGUISHERS REQUIRED IN ALL UNITS & COMMUNITY ROOM. G.C. TO VERIFY TYPE & SIZE W/ CITY AHJ & FINAL LOCATION WITH ARCHITECT. SEE A0.2's, A0.3's, A4's FOR: HORIZONTAL & VERTICAL ASSEMBLIES ROOF TYPE ASSEMBLIES X.X* = EXT. RIGID INSULATION IS ADDED ASSEMBLIES LEGEND R-# FLOOR TYPE ASSEMBLIESF-# EXTERIOR WALL TYPE ASSEMBLIESE-# INTERIOR WALL TYPE ASSEMBLIESI-# RA-# FB-# RADON ASSEMBLY FIRE BLOCKING SEE A0.0a FOR ALTERNATE NOTES. ALTERNATE NOTE SEE CODE PLANS AND SECITON FOR RATED FLOOR, CEILING AND ROOF ASSEMBLIES. CODE NOTE SEE SPECIFICATIONS FOR PRODUCT INFORMATION SPEC NOTE SEE OVERALL BUILDING PLANS FOR WINDOWS. SEE WINDOW SCHEDULE ON A0.5.X WINDOW TYPES & SCHEDULE NOT USED KEYED NOTES - THIS SHEET ONLY 1 A B C C D D D D D D D E A C D D E B C E A B C C D D D D D D E A C D D E B C E S T E D D D D D AC E AC B C D D E D D E AC B C D DD D D BC E ACB C D D E D D E ACB C D DD D E AC D F G G G G HH C202 C205 C206 C201C203 C204 1 A4.1 E-2 E-2 E-2 E-2 I-G I-G I-A I-A I-BI-B I-A I-A I-A I-A I-A I-A I-A I-BI-B I-A I-A I-A I-A I-A I-A I-A I-A