HomeMy WebLinkAbout022_C303-BuildingAFireServicePlanProfileWWWW W W W W WWWWW WW W W W W UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEVITREOUS CHINATOILETDEVONSHIREK-3457 VITREOUS CHINATOILETDEVONSHIREK-3457 VITREOUS CHINATOILETDEVONSHIREK-3457 VITREOUS CHINATOILETDEVONSHIREK-3457 STSTSTSTSTSTST STSTSTSTSTSTSTSTST 0+00.00 0+75.00 0+50.00 ELEVATIONSTATION 4900 4910 0+00 0+25 0+50 0+75 1+00 6" D.I. MJ CONNECTION TO EXISTING 6" GATE VALVE STA =0+23.91 INV EL = 4901.58 6" D.I. 90° HORZ BEND W/ THRUST BLOCK STA =0+27.01 INV EL = 4901.63 6" D.I. 90° HORZ BEND W/ THRUST BLOCK STA =0+50.16 INV EL = 4901.92 6" D.I. 90° VERT BEND W/ THRUST BLOCK STA =0+70.31 INV EL = 4902.19 UTILTIY CROSSING STA =0+44.89 4" D.I. DOMESTIC WATER SERVICE INV EL = 4902.99 6" D.I. FIRE SERVICE TOP OF PIPE = 4902.34 UTILTIY CROSSING STA =0+55.14 10" STORM SEWER INV EL = 4907.26 6" D.I. FIRE SERVICE TOP OF PIPE = 4902.40 2" DRY UTILITY CONDUIT UNDERGROUND ELECTRICAL STA =0+20.02 INV EL = 4908.40 20.21 LF OF 6" DUCTILE IRON22.14 LF OF 6" DUCTILE IRON2.70 LF OF 6" DUCTILE IRON DRAWING:Print Date:Copyright 2022, Graham Engineering LLC10/24/2025 9:26 AMZ:\PROJECTS\ENCOMPASS\25008-EDMT-HIGHLANDS\CAD\HIGHLANDS_C303_BLDG A FIRE SERVICE P&P.DWG DRAWING NUMBER:Checked:Drawn:PROJECT NO:GRAHAM ENGINEERING LLCDATE DESCRIPTION REVISIONS This drawing and all related documents (including those on electronic media) were prepared by GRAHAMENGINEERING LLC, except as noted otherwise herein, as instruments of service, and shall remain the property ofGRAHAM ENGINEERING LLC. The information shown herein shall be used only by the client to whom the service arerendered and only for the purpose of constructing or installing the work as shown at the designated location and site.Any other use of said documents, including (without limitation) any reproduction or alteration, is strictly prohibited, andthe user shall hold harmless and indemnify GRAHAM ENGINEERING LLC from all liabilities which may arise fromsuch unauthorized use. Such use hall cause the waiver of expressed or implied warranties and shall serve anyliabilities which may arise from construction, use or result of such unauthorized use or changes.ORIGINAL DATE: PERMIT DATE: IFC DATE:PLAN & PROFILE: BLDG A FIRE SERVICEHIGHLANDS APARTMENTSC303 ZWGTMRBOZEMAN, MT25008_EDMT-HIGHLANDS10/24/2025NREMINGTON WAYLEGEND CONSTRUCTION NOTES 1.THRUST BLOCKS TO BE INSTALLED IN ACCORDANCE WITH DETAIL 1/C407. 10/24/2025 PLAN VIEW SCALE: 1" = 5' PROFILE VIEW HORIZONTAL SCALE: 1" = 5' VERTICAL SCALE: 1" = 2' KEYNOTES EXISTING 6" WATER STUB EXISTING 6" GATE VALVE (RELOCATED PER C010) EXISTING 4" WATER STUB EXISTING 4" GATE VALVE (RELOCATED PER C010) PROPOSED 6" D.I. FIRE SERVICE PROPOSED 4" D.I. DOMESTIC WATER SERVICE PROPOSED 6" 90° HORZ BEND W/ TRUST BLOCK - SEE NOTE 1 PROPOSED 4" 90° HORZ BEND W/ TRUST BLOCK - SEE NOTE 1 PROPOSED 6" 90° VERT BEND W/ TRUST BLOCK - SEE NOTE 1 PROPOSED 4" 90° VERT BEND W/ TRUST BLOCK - SEE NOTE 1 FIRE RISER ROOM - SEE BUILDING PLANS STORM AREA INLET - SEE C200 1 2 3 4 5 6 7 8 9 1 10 11 12 3 4 7 5 9 10 11 12 2 6 12 7 8 8 EXISTING SURFACE PROPOSED SURFACE BLDG A PROPERTY LINE - SUBJECT PARCEL(S) EASEMENT EXISTING SANITARY SEWER EXISTING WATERMAIN EXISTING GATE VALVE PROPOSED STORM SEWER PROPOSED DOMESTIC WATER PROPOSED FIRE SERVICE ST ST W W W W