Loading...
HomeMy WebLinkAbout012 - ElectricalFixtureCutSheetsSLIM18Y/D10 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 1 of 3 12, 18 and 26 Watt SLIM wall packs are ultra efficient and deliver impressive light distribution with a compact low-profile design that's super easy to install as a downlight or uplight. Color: Bronze Weight: 4.1 lbs Project:Type: Prepared By:Date: Driver Info Type Constant Current 120V 0.18A 208V 0.09A 240V 0.09A 277V 0.08A Input Watts 21W LED Info Watts 18W Color Temp 3000K (Warm) Color Accuracy 71 CRI L70 Lifespan 100,000 Hours Lumens 2,494 lm Efficacy 118.8 lm/W Technical Specifications Compliance UL Listed: Suitable for wet locations. Suitable for mounting within 4 ft (1.2m) of the ground. IP Rating: Ingress protection rating of IP66 for dust and water ADA Compliant: SLIM™ is ADA Compliant IESNA LM-79 & LM-80 Testing: RAB LED luminaires and LED components have been tested by an independent laboratory in accordance with IESNA LM-79 and LM-80. Dark Sky Conformance: Dark Sky Approved in 3000K. Conforms to (allows for conformance to) the IDA's fully shielding requirement, emitting no light above 90 degrees (with the exclusion of incidental light reflecting from fixture housing, mounts, and pole). DLC Listed: This product is listed by Design Lights Consortium (DLC) as an ultra-efficient premium product that qualifies for the highest tier of rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements. DLC Product Code: PTHNSBDK LED Characteristics LED: Multi-chip, long-life LED Color Consistency: 3-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color Color Stability: LED color temperature is warrantied to shift no more than 200K in color temperature over a 5-year period Color Uniformity: RAB's range of Correlated Color Temperature follows the guidelines for the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017. Performance Lifespan: 100,000-Hour LED lifespan based on IES LM-80 results and TM-21 calculations Wattage Equivalency: Equivalent to 100W Metal Halide Construction Cold Weather Starting: The minimum starting temperature is -40°C (-40°F) Maximum Ambient Temperature: Suitable for use in up to 40°C (104°F) Housing: Precision die-cast aluminum housing Lens: Tempered glass lens Reflector: Specular thermoplastic Gaskets: High-temperature silicone Finish: Formulated for high durability and long-lasting color Green Technology: Mercury and UV free. RoHS-compliant components. Installation Mounting: Heavy-duty mounting bracket with hinged housing for easy installation Recommended Mounting Height: Up to 14 ft SLIM18Y/D10 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 2 of 3 Technical Specifications (continued) Other Patents: The design of the SLIM™ is protected by patents in U.S. Pat D681,864, and pending patents in Canada, China, Taiwan and Mexico. HID Replacement Range: Replaces 100W Metal Halide Warranty: RAB warrants that our LED products will be free from defects in materials and workmanship for a period of five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish. RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty. Optical BUG Rating: B1 U0 G0 Electrical Driver: Constant Current, Class 2, 100-277V, 50/60 Hz., 4KV surge protection, 120V: 0.19A, 208V: 0.11A, 240V: 0.10A, 277V: 0.08A THD: 5% at 120V, 11.3% at 277V Power Factor: 99.6% at 120V, 91.4% at 277V Dimensions Features Full cutoff, fully shielded LED wall pack Can be used as a downlight or uplight Contractor friendly features for easy installation 100,000-hour LED Life 5-Year, No-Compromise Warranty SLIM18Y/D10 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 3 of 3 Ordering Matrix Family Wattage Color Temp Finish Driver Options SLIM 18 Y /D10 12 = 12W 18 = 18W 26 = 26W Blank = 5000K Cool N = 4000K Neutral Y = 3000K Warm Blank = Bronze W = White Blank = 120-277V, 0-10V Dimming /D10 = 120-277V, 0-10V Dimming Blank = No Option /PC = 120V Button /PC2 = 277V Button /LC = Lightcloud DISK34-6 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 1 of 3 Color: White Weight: 0.5 lbs Project:Type: Prepared By:Date: Driver Info Type Constant Current 120V .14A 208V N/A 240V N/A 277V N/A Input Watts 15W LED Info Watts 15W Color Temp 2700/3000/3500/4000/5000K Color Accuracy 90 CRI L70 Lifespan 50,000 Hours Lumens 1,000 lm Efficacy 67 Technical Specifications Performance Product Type: Disk Surface Mount Description: Low-profile, surface-mount disk with field-adjustable color temperature for use in dry, damp and wet environments. Wattage Equivalency: 75W Incandescent Input Wattage: 15W Lumens: 2700K @ 1,017lm; 3000K @ 1,077lm; 3500K @ 1,128lm; 4000K @ 1,132lm; 5000K @ 1,088lm Efficacy: 2700K @ 68lm/W; 3000K @ 72lm/W; 3500K @ 77lm/W; 4000K @ 76lm/W; 5000K @ 73lm/W L70 Lifespan: 50,000-Hour LED lifespan based on IES LM-70 results Electrical Driver: Constant Current, 60 Hz, 120V, 120V: 0.09A THD: ≤20% Power Factor: ≥0.9 Dimmable: Yes, dimmable down to 10% on compatible TRIAC/ELV dimming systems. See Dimmer Compatibility List. Input Voltage: 120V Operating Frequency: 60 Hz Input Current @ 120V: 136mA Operating Temperature: -4°F to 104°F (-20°C to 40°C) Flicker: ≤30% LED Characteristics Beam Angle: 110°±10° Color Temperature: Field Adjustable dip switch 2700/3000/3500/4000/5000K Color Accuracy (CRI): >90 CRI R9 Value: High color performance with R9 greater than or equal to 50 Color Consistency: 4-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color Installation Mounting: Surface Mount + Recessed Construction Size: 6" Shape: Round Finish: White Enclosure Material: Metal DISK34-6 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 2 of 3 Technical Specifications (continued) Trim Style: Smooth Lens: Polycarbonate light diffuser distributes light evenly and smoothly for general lighting applications Compliance Listings: UL Listed Environment: Suitable for indoor and outdoor applications in dry, damp, and wet environments. IC Rated: No Air Tight: No T20 Compliant: Not applicable California Title 24 JA8 Compliant: Can be used to conform with the requirements of California Title 24 Part 6 California Energy Commission (CEC) Status: Lawful for Sales in California NEC Compliant: Suitable for use in closets. Compliant with NEC Sec. 410.16 (A)(1) and 410.16 (C1). IESNA LM-79 & LM-80 Testing: RAB LED luminaires and LED components have been tested by an independent laboratory in accordance with IESNA LM-79 and LM-80. RoHS Compliant: Mercury and UV free. RoHS-compliant components. FCC: Complies with Part 15B of the FCC Rules Trade Agreements Act Compliant: This product is a product of Cambodia and a "designated country" end product that complies with the Trade Agreements Act Energy Star Approved: ENERGY STAR® Version 1.0 Certified Certification Model Number: DLR0124(R6R149FA120WS) Other Accessories: DSKFA6/PIR/ACC Mounting hardware Warranty: RAB warrants that our LED products will be free from defects in materials and workmanship for a period of five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish. RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty. \ DISK34-6 Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 3 of 3 Dimensions Features Low-profile, back-lit design made of durable thermoplastic housing with frosted lens 5 Color temperature selectable: 2700K, 3000K, 3500K, 4000K, & 5000K New construction or retrofit applications Installs on standard junction boxes Suitable for indoor/outdoor use in dry, damp, and wet locations Ordering Matrix Family Size (Wattage)Shape CRI/Color Temp Driver Finish Trim DISK34 6 4 = 4" (10W) 6 = 6" (15W) Blank = Round Blank = 90CRI, 2700/3000/3500/4000/5000K CCT Adjustable Blank = 120V, TRIAC/ELV Blank = White Blank = Smooth SSS-B Series Poles SQUARE STRAIGHT STEEL Page 1 of 5 (Rev 06/19/24) BEA_SSS-B-Poles_spec_R04 currentlighting.com/beacon © 2024 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. BASE DETAILBASE POLE CAP Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. TENON Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. BASE COVER Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. CONSTRUCTION • Shaft: One-piece straight steel with square cross section, flat sides and minimum 0.23" radius on all corners; Minimum yield of 46,000 psi (ASTM-A500, Grade B); Longitudinal weld seam to appear flush with shaft side wall; Steel base plate with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ASTM A36) • Base cover: Two-piece square aluminum base cover included standard • Pole cap: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available • Hand hole: Rectangular 3x5 steel hand hole frame (2.38" x 4.38" opening); Mounting provisions for grounding lug located behind gasketed cover • Anchor bolts: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling • Anchor bolt part numbers: 3/4 x 30 x 3 — TAB-30-M38 1 x 36 x 4 — TAB-36-M38 • Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness • Powder paint prime applied over “white metal” steel substrate cleaned via mechanical shot blast method • Decorative finish coat available in multiple standard colors; Custom colors available; RAL number preferable INSTALLATION • Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location SPECIFICATIONS DATE:LOCATION: TYPE:PROJECT: CATALOG #: RSA RSS SSS Overall Height 8'–30' Overall Height 8'–30' Overall Height 8'–40' Handhole 18" Handhole 18" Handhole 18" SSS-B Series Poles SQUARE STRAIGHT STEEL Page 2 of 5 (Rev 06/19/24) BEA_SSS-B-Poles_spec_R04 currentlighting.com/beacon © 2024 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. SSS-B ––––––– Series Height Shaft Thickness Mounting Drill Pattern Finish Options SSS-B Square Straight Steel Pole Beacon Reference page 3 Ordering matrix Reference page 3 Ordering matrix Reference page 3 Ordering matrix A - .125" WallB - .188" WallC - .250" Wall 1 Single arm mount 2 Two fixtures at 180˚ 2L Two fixtures at 90˚ 3T Three fixtures at 90˚ 4 Four fixtures at 90˚ TA Tenon (2.38" OD x 4" Tall) TB Tenon (2.88" OD x 4" Tall) TC Tenon (3.5" OD x 6" Tall) TR 1 Removable Tenon (2.375" x 4.25") OT Open Top (includes pole cap) B1 Cruzer, “AM” arm B3 2 bolt (2-1/2" spacing), Viper “A” arm S2 2 bolt (3-1/2" spacing), Viper “AD” arm UDP Universal Drill Pattern BLT Black Matte Textured BLS Black Gloss Smooth DBT Dark Bronze Matte Textured DBS Dark Bronze Gloss Smooth GTT Graphite Matte Textured LGT Light Grey Matte Textured LGS Light Grey Gloss Smooth PSS Platinum Silver Smooth WHT White Matte Textured WHS White Gloss Smooth VGT Verde Green Textured Color Option CC Custom Color 2 GFI 3 20 Amp GFCI Receptacle and Cover EHH 3 Extra Handhole C05 3 .5" Coupling C07 3 .75" Coupling C20 3 2" Coupling MPB 3 Mid-pole Luminaire Bracket VM1 4 Mode vibration dampener VM2 5 2nd mode vibration dampener LAB Less Anchor Bolts UL UL Certified ORDERING INFORMATION Example: SSS-B–25–40–A–2L–S2–DBT–UL 1 Removable tenon used in conjunction with side arm mounting. First specify desired arm configuration followed by the “TR” notation. Example: SSS-B-25-40-A-1-B1-TR-BBTT. 2 Custom colors available; RAL number preferable 3 Specify option location using logic found on page 3 (Option Orientation). 4 VM1 recommended on poles 20’ and taller with EPA of less than 1. 5 There will be a weld witness mark on the side of the pole with the Factory installed VM2 MOUNTING ORIENTATION Denotes handhole location 1 2 2L 3T 4 DRILL PATTERNS TOP OF POLE 3.50 MIN MAX W1 W2UDP01, UDP02UDP03, UDP04UDP05, UDP06UDP07, UDP08UDP09, UDP010UDP011, UDP012Two Bolt Mounting with Center Wireway Mounting Hardware Universal Mounting Patterns 3/8" or less UDP01 UDP03 UDP05 UDP07 UDP09 UDP011 7/16" to 1/2"UDP02 UDP04 UDP06 UDP08 UDP010 UDP012 “Min” Attachment Dimension 1.69 2.25 3.00 3.76 4.50 5.50 “Max” Attachment Dimension 2.24 2.99 3.75 4.49 5.49 6.00 W1 (Wireway min)0.85 1.00 1.00 1.00 1.00 1.00 W2 (Wireway max)1.05 1.36 1.88 2.13 2.60 3.00 UNIVERSAL DRILL PATTERN (UDP) DATE:LOCATION: TYPE:PROJECT: CATALOG #: Accessories (Order Separately) VM2S08 Field-installed 2nd mode vibration dampener - 8 ft VM2S12 Field-installed 2nd mode vibration dampener - 12 ft VM2S16 Field-installed 2nd mode vibration dampener - 16 ft VM2S20 Field-installed 2nd mode vibration dampener - 20 ft VM2S25 Field-installed 2nd mode vibration dampener - 25 ft SSS-B Series Poles SQUARE STRAIGHT STEEL Page 3 of 5 (Rev 06/19/24) BEA_SSS-B-Poles_spec_R04 currentlighting.com/beacon © 2024 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. CATALOG NUMBER HEIGHT NOMINAL SHAFT DIMENSIONS WALL THICKNESS BOLT CIRCLE(SUGGESTED)BOLT CIRCLE(RANGE)BASE PLATE SQUARE ANCHOR BOLT SIZE BOLT PROJECTION POLE WEIGHT (LBS)FEET METERS SSS-B-10-40-A-XX-XX 10 3.0 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 77 SSS-B-12-40-A-XX-XX 12 3.7 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 90 SSS-B-14-40-A-XX-XX 14 4.3 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 103 SSS-B-16-40-A-XX-XX 16 4.9 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 116 SSS-B-18-40-A-XX-XX 18 5.5 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 129 SSS-B-20-40-A-XX-XX 20 6.1 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 142 SSS-B-25-40-A-XX-XX 25 7.6 4" square 0.125"9"8" - 10"9"3/4" x 30" x 3"3.5 175 SSS-B-14-40-B-XX-XX 14 4.3 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 152 SSS-B-16-40-B-XX-XX 16 4.9 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 171 SSS-B-18-40-B-XX-XX 18 5.5 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 190 SSS-B-20-40-B-XX-XX 20 6.1 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 209 SSS-B-25-40-B-XX-XX 25 7.6 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 257 SSS-B-30-40-B-XX-XX 30 9.1 4" square .188"11"10" - 12"10.50"3/4" x 30" x 3"3.5 304 SSS-B-16-50-B-XX-XX 16 4.9 5" square .188"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 219 SSS-B-18-50-B-XX-XX 18 5.5 5" square .188"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 243 SSS-B-20-50-B-XX-XX 20 6.1 5" square .188"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 267 SSS-B-25-50-B-XX-XX 25 7.6 5" square .188"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 327 SSS-B-30-50-B-XX-XX 30 9.1 5" square .188"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 387 SSS-B-25-50-C-XX-XX 25 7.6 5" square .25"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 427 SSS-B-30-50-C-XX-XX 30 9.1 5" square .25"11"10.25" - 13.25"11.50"1" x 36" x 4"4.5 507 SSS-B-20-60-B-XX-XX 20 6.1 6" square .188"12"11.00" - 13.25"12.25"1" x 36" x 4"4.5 329 SSS-B-25-60-B-XX-XX 25 7.6 6" square .188"12"11.00" - 13.25"12.25"1" x 36" x 4"4.5 404 SSS-B-30-60-B-XX-XX 30 9.1 6" square .188"12"11.00" - 13.25"12.25"1" x 36" x 4"4.5 479 SSS-B-35-60-B-XX-XX 35 10.7 6" square .188"12"11.00" - 13.25"12.25"1" x 36" x 4"4.5 554 SSS-B-40-60-B-XX-XX 40 12.2 6" square .188"12"11.00" - 13.25"12.25"1" x 36" x 4"4.5 629 ORDERING INFORMATION (CONTINUED) EHH Extra handholeAnchor Base DetailBolt CircleBolt Slots/Holes0°-HandholeBolt Square270°Arm 1 90° Arm 2 180°As viewed from top of pole.90° Arm 2 Provision for Grounding C05 / C07 / C20 Coupling 1/2" - 14 NPSC Threads 3/4" - 14 NPSC Threads 2" -11.5 NPSC Threads VM1 1st mode vibration dampener Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. VM1 Pole Field Installed Pole Top dampener designed to reduce pole top deflection or sway. VM1 is recommended for pole systems 25' and taller with a total EPA of 1.0 or less. VM2 1 2nd mode vibration dampener Factory installed, internal dampener designed to alter pole resonance to reduce movement and material fatigue caused by 2nd mode vibration. OverallHeight 10'-30' 18" TENON Bolt Circle (Outer) Bolt Circle (Inner) Bolt Square (Outer) Bolt Square (Inner) Height of option in feet BASE COVER 270˚90˚ 180˚ 0˚ Handhole VIBRATION DAMPER2ND MODE VM2S08 – 8'VM2S12 – 12'VM2S16 – 16'VM2S20 – 20'VM2S24 – 24' VM2SXX Field-installed 2nd mode vibration dampener Field installed, internal dampener designed to alter pole resonance to reduce movement and material fatigue caused by 2nd mode vibration. GFI 20 Amp GCFI Receptacle & Cover Bolt Circle Bolt Slots/Holes °-Handhole 270°Arm 1 Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Square Steel Pole Standard hand hole frame Adapter plate Gasket 20 AMP GFCI Wet LocationsIn-use Cover MPB Mid Pole Bracket Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-HandholeBolt Square 270°Arm 1 90° Arm 2 180° As viewed from top of pole. Square Steel Pole Attachment stub, 5" long, welded to pole Arm, 3" Sq. x 13.5" long (ships separately) 2" pipe tenon, 4.25" tall OverallHeight 10'-30' 18" TENON Bolt Circle (Outer) Bolt Circle (Inner) Bolt Square (Outer) Bolt Square (Inner) Height of option in feet BASE COVER 270˚90˚ 180˚ 0˚ Handhole VIBRATION DAMPER2ND MODE Follow the logic below when ordering location specific options. For each option, include its orientation (in degrees) and its height (in feet). Example: Option C05 should be ordered as: SSS-B-20-40-A-TA-DBT-CO5-0-15 (.5" coupling on the handhole/arm side of pole, 15' up from the pole base) 1' spacing required between option. Consult factory for other configurations. Option Orientation Height of option in feet DATE:LOCATION: TYPE:PROJECT: CATALOG #: Notes: • Factory supplied template must be used when setting anchor bolts. Current will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts. • For more information about pole vibration and vibration dampeners, please consult factory. • Unwrap poles immediately upon receipt to avoid condensation build up and possible corrosion. 1 There will be a weld witness mark on the side of the pole with the Factory installed VM2. SSS-B Series Poles SQUARE STRAIGHT STEEL Page 4 of 5 (Rev 06/19/24) BEA_SSS-B-Poles_spec_R04 currentlighting.com/beacon © 2024 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. DATE:LOCATION: TYPE:PROJECT: CATALOG #: Florida Building Code 2017 EPA Load Rating - 3 second gust wind speeds(Use for Florida only) Catalog Number 115 120 130 140 150 160 170 180 SSS-B-10-40-A 25.0 25.0 25.0 25.0 21.4 18.4 15.9 13.9 SSS-B-12-40-A 25.0 25.0 23.6 19.8 16.7 14.2 12.1 10.4 SSS-B-14-40-A 25.0 23.1 19.0 15.7 13.1 10.9 9.1 7.6 SSS-B-16-40-A 20.8 18.7 15.2 12.3 10.1 8.2 6.7 5.4 SSS-B-18-40-A 16.8 15.0 11.9 9.4 7.5 5.9 4.5 3.4 SSS-B-20-40-A 13.6 11.9 9.2 7.1 5.3 3.9 2.7 1.7 SSS-B-25-40-A 7.4 6.2 4.1 2.5 1.1 NR NR NR SSS-B-14-40-B 25.0 23.6 19.4 16.1 13.4 11.2 9.4 7.8 SSS-B-16-40-B 21.4 19.2 15.6 12.7 10.4 8.5 6.9 5.6 SSS-B-18-40-B 17.2 15.4 12.2 9.7 7.7 6.1 4.7 3.6 SSS-B-20-40-B 13.9 12.3 9.5 7.3 5.5 4.1 2.9 1.9 SSS-B-25-40-B 7.7 6.4 4.3 2.6 1.3 NR NR NR SSS-B-30-40-B 3.2 2.1 NR NR NR NR NR NR SSS-B-16-50-B 25.0 25.0 25.0 25.0 25.0 21.4 18.2 15.5 SSS-B-18-50-B 25.0 25.0 25.0 24.4 20.4 17.0 14.2 11.9 SSS-B-20-50-B 25.0 25.0 24.4 19.9 1 6.3 13.4 11.0 8.9 SSS-B-25-50-B 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1 SSS-B-30-50-B 13.7 11.7 8.2 5.5 3.3 1.5 NR NR SSS-B-25-50-C 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1 SSS-B-30-50-C 13.7 11.7 8.2 5.5 3.3 1.5 NR NR SSS-B-20-60-B 25.0 25.0 25.0 21.9 17.8 14.5 11.7 9.4 SSS-B-25-60-B 23.8 20.9 16.1 12.3 9.2 6.6 4.5 2.8 SSS-B-30-60-B 14.6 12.3 8.4 5.3 2.8 0.8 NR NR SSS-B-35-60-B 7.5 5.6 2.4 NR NR NR NR NR SSS-B-40-60-B 1.8 NR NR NR NR NR NR NR ASCE 7-05 wind map EPA Load Rating - 3 second gust wind speeds(Use for all locations except Florida) Catalog Number 85 90 100 105 110 120 130 140 145 150 SSS-B-10-40-A 25.0 25.0 25.0 22.8 20.6 17.0 14.2 11.9 11.0 10.1 SSS-B-12-40-A 25.0 25.0 20.0 18.0 16.1 13.2 10.8 8.9 8.1 7.4 SSS-B-14-40-A 23.1 20.4 16.1 14.3 12.8 10.2 8.2 6.6 5.9 5.3 SSS-B-16-40-A 19.0 16.7 13.0 11.5 10.1 7.9 6.2 4.7 4.1 3.6 SSS-B-18-40-A 15.6 13.6 10.0 9.0 7.8 5.9 4.4 3.1 2.6 2.1 SSS-B-20-40-A 12.7 10.9 7.9 6.9 5.9 4.2 2.8 1.7 1.3 0.9 SSS-B-25-40-A 7.3 5.9 3.8 2.9 2.1 0.8 NR NR NR NR SSS-B-14-40-B 25.0 25.0 23.3 20.8 18.6 15.1 12.3 10.2 9.2 8.4 SSS-B-16-40-B 25.0 24.9 19.4 17.3 15.4 12.3 9.9 8.0 7.2 6.4 SSS-B-18-40-B 24.0 20.8 16.1 14.2 12.5 9.8 7.7 6.1 5.3 4.7 SSS-B-20-40-B 20.2 17.5 13.2 11.6 10.1 7.7 5.9 4.4 3.8 3.2 SSS-B-25-40-B 12.8 11.0 7.9 6.7 5.5 3.7 2.3 1.2 0.7 NR SSS-B-30-40-B 8.0 6.6 4.1 3.1 2.2 0.8 NR NR NR NR SSS-B-16-50-B 25.0 25.0 25.0 25.0 24.8 20.1 16.5 13.6 12.3 11.2 SSS-B-18-50-B 25.0 25.0 25.0 22.9 20.4 16.4 13.2 10.7 9.6 8.6 SSS-B-20-50-B 25.0 25.0 21.3 18.9 16.7 13.2 10.4 8.1 7.2 6.3 SSS-B-25-50-B 20.7 17.8 13.3 11.5 9.8 7.2 5.0 3.3 2.6 1.9 SSS-B-30-50-B 13.5 11.3 7.7 6.2 4.9 2.8 1.1 NR NR NR SSS-B-25-50-C 25.0 25.0 19.4 17.1 15.1 11.7 9.0 6.9 6.0 5.1 SSS-B-30-50-C 20.1 17.3 12.7 10.9 9.3 6.6 4.5 2.8 2.1 1.4 SSS-B-20-60-B 25.0 25.0 25.0 25.0 25.0 20.2 16.1 12.9 11.5 10.3 SSS-B-25-60-B 25.0 25.0 20.6 18.0 15.6 11.8 8.7 6.2 5.2 4.2 SSS-B-30-60-B 21.4 18.1 12.9 10.7 8.8 5.7 3.3 1.3 NR NR SSS-B-35-60-B 14.0 11.3 6.9 5.2 3.6 1.0 NR NR NR NR SSS-B-40-60-B 8.1 5.8 2.2 nr NR NR NR NR NR NR NOTES: • Values are based on 50 year mean recurrence interval 30’ above grade. • Hawaii has an 105 mph wind velocity. • Puerto Rico has a 125 mph wind velocity. • Caution must be exercised in determining wind velocities in special wind areas such as: Mountainous Regions Areas surrounding the Great Lakes or other large bodies of water or open land. Areas subject to extreme wind conditions, such as hurricanes, typhoons, cyclones, and tornadoes. Areas adjacent to airports. Any specific area with a known or suspected abnormally high intermittent wind condition caused by geography, adjacent structures, or other specific local conditions that may not be recorded in National Weather Service records. • Allowable pole EPA for jobsite wind conditions must be equal to or greater than fixture EPA. Responsibility lies with the specifier for correct pole selection based on AASHTO wind map and job location. • The Wind Map is intended only as a general guide. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application. • CAUTION: Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide. Consult AASHTO standards. • Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or Tornadoes expose poles to flying debris, wind shear, and other unpredictable aerodynamic forces not indicated by the wind velocity ratings. • Pole Strength Limited Warranty: Standard, unmodified Kim lighting Poles installed as recommended, undamaged by corrosion, or lack of maintenance, shall withstand steady wind conditions as provided on page 2 (Allowable Pole EPA). Installation of poles without luminaires, or attachment of any unauthorized accessories to poles shall void this warranty. 85 90 90100110120 130 130 140 140 140 150 150 14013012011010090 Special Wind Region(Consult Local Authorities) 90 180 180 170 170 160 160 150 150 140 140140150 140 150 130 120 115 115120130 Florida region wind map above is based upon 3-second gust winds and the 2017 Florida Building Code. HAWAII – 105 mph PUERTO RICO – 145 mph FLORIDA REGION WIND MAP 120 11010090 90 100 110 120 130 130 130 130 ALASKA REGION WIND MAP ASCE7-05 WIND MAP *Printed with permission from ASCE WIND MAPS SSS-B Series Poles SQUARE STRAIGHT STEEL Page 5 of 5 (Rev 06/19/24) BEA_SSS-B-Poles_spec_R04 currentlighting.com/beacon © 2024 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. DATE:LOCATION: TYPE:PROJECT: CATALOG #: NOTES Wind-speed Website disclaimer: Current has no connection to the linked website and makes no representations as to its accuracy. While the information presented on this third party website provides a useful starting point for analyzing wind conditions, Current has not verified any of the information on this third party website and assumes no responsibility or liability for its accuracy. The material presented in the windspeed website should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. Current does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the windspeed report provided by this website. Users of the information from this third party website assume all liability arising from such use. Use of the output of these referenced websites do not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the windspeed report. http://windspeed.atcouncil.org • Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs. • The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application • Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty • Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide; Consult local and federal standards • Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Current Lighting’s Pole Vibration Application Guide for environmental risk factors and design considerations. • Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings