Loading...
HomeMy WebLinkAbout007 - Concurrence Tech Memo Page | 1 Technical Memorandum Subject: Highlands Apartments - Concurrence with Subdivision Traffic, Water, and Sewer Plans Date: July 23, 2025 The Highlands is a proposed affordable multifamily housing development to be located on Lots 1 and 2 of Block 2 of the Aaker Subdivision (City of Bozeman Master Site Plan Project #22381). The subdivision completed a Traffic Impact Study, a Water Engineer’s Report, and a Sewer Engineer’s Report for the entire subdivision. This memorandum is to verify the proposed design of the Highlands is in concurrence with the Subdivision reports. Aaker Subdivision assumed 250 housing units on the lots for the proposed multifamily housing. The proposed project contains 149 housing units. For traffic, water, and sewer, this reduction in units means that the designs proposed by the subdivision will be adequate. Each is discussed in detail below. Traffic The proposed design for Highlands, with a reduction to 149 units from the 250 units anticipated with subdivision approval, will generate less trips than assumed by the Traffic Impact Study. Any upgrades or changes proposed in the approved traffic study for Aaker subdivision will be adequate to accommodate the traffic from the proposed multifamily housing development. According to the City of Bozeman Design and Construction Standards, a development previously included in a Transportation Impact Study only requires a new one if the trip generation exceeds the assumed values, or if the original is more than 5 years old. The Aaker Subdivision Traffic Study was completed two years ago in 2023. Water The City of Bozeman Design and Construction Standards (COBDCS) were updated in 2024 after the Aaker Subdivision Master Site plan was approved. The revisions affect the calculation of water and sewer demand by changing the assumptions of capita per unit and the gallons per day (GPD) per capita. A comparison of the water demand for these lots by the subdivision developer under the old standards with the proposed design under the new standards is summarized in Table 1 below. Table 1 – Water Demand Comparison Calculation Source Units Capita/ unit Population GPD/Capita Residential Demand (GPD) Subdivision Calculation (Prior COBDCS) 250 2.11 527.5 89 46,948 Proposed Design (COBDCS, 2024) 149 2.17 323.3 135 43,650 Page | 2 The revised COBDCS yield a higher demand per unit, but with the reduction in units in the proposed design, the overall demand remains below the subdivision master plan assumption. All designs for the water distribution for the subdivision are adequate. Sewer The updates to the COBDCS between the subdivision approved design and the design of the proposed project include updates to the assumptions of capita per unit and gallons per day per capita, similar to the water demand updates. A sewer base infiltration rate is now added to the demand. The base infiltration rate adds an additional 150 gallons/acre/day. Lots 1 and 2 where Highlands will be built contain 4.30 acres, which will result in an additional 645 GPD. Table 2 – Sewer Demand Calculation Calculation Source Units Capita/ unit Population GPD/ Capita Base Infiltration Rate (GPD) Residential Demand (GPD) Subdivision Calculation (Prior COBDCS) 250 2.11 527.5 89 0 46,948 Proposed Design (COBDCS, 2024) 149 2.17 323.3 64.4 645 21,468 The reduction in units and the changes in calculation result in a lower residential demand for sewer, so sewer infrastructure designed by the subdivision will be adequate to serve the proposed multifamily housing development. For any additional comments or need for information please contact the undersigned. Zack Graham Graham Engineering LLC 406.624.2686 zack@grahameng.com