HomeMy WebLinkAboutBOZEMAN SENIOR CENTER - ELEV UPGRADES - E1.1 LEVEL ONE FLOOR PLAN - POWER - ADDN 2 REV 1-26-26 .o..rTmgi GENERAL NOTES =*,•° Scott T. a Elders 1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INCLUDING EQUIPMENT SUPPLIERS TO COORDINATE WITH EACH OTHER AND TO VERIFY No.2902 THAT THERE ARE NO CONFLICTS IN LOCATIONS OF DUCTS, CONDUITS, SPRINKLER HEADS, SPRINKLER PIPING, DIFFUSERS, ELECTRICAL ••� � BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT, BEFORE FINAL PLACEMENT OF MATERIALS. Vk NS 2. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION: DETAILED EQUIPMENT REQUIREMENTS, INSTALLATION INSTRUCTIONS, I11 PERFORMANCE REQUIREMENTS, CONTROL SEQUENCES AND ALL OTHER PROJECT DETAILS. 3. INSTALL ALL NEW WORK TO MEET CURRENT CODES AND INSTALLATION STANDARDS. 4. ALL VOICE,VOICE/DATA AND THERMOSTAT ROUGH-INS SHALL BE PROVIDED USING A 4"SQ ELECTRICAL BOX, SINGLE GANG MUD-RING AND 3/4"CONDUIT FROM THE BOX TO THE ACCESSIBLE CEILING SPACE, UNLESS NOTED OTHERWISE. REFER TO THE LOW-VOLTAGE RACEWAY DETAIL. PROVIDE AT MOUNTING HEIGHTS SPECIFIED IN THE SPECIFICATIONS, UNLESS OTHERWISE NOTED ON THE DRAWINGS. Z O 5. PROVIDE ROUGH-INS FOR ALL MECHANICAL THERMOSTATS AND SENSORS SHOWN ON THE MECHANICAL DRAWINGS PER THE LOW-VOLTAGE /A RACEWAY DETAIL. N j it W 6. PROVIDE HEAVY DUTY RATED DISCONNECTS FOR ALL EQUIPMENT PER THE CURRENT NEC, EVEN WHEN NOT SHOWN. Of 7. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING ANY SHOP DRAWINGS OF OTHER DOCUMENTATION TO THE CITY AS REQUIRED Z TO OBTAIN A PERMIT FOR INSTALLATION OF THE FIRE ALARM SYSTEM. W 0 B. ELECTRICIAN AND ACCESS CONTROLS CONTRACTORS SHALL REVIEW DOOR HARDWARE&ACCESS CONTROL SUBMITTALS PRIOR TO ROUGH-IN. Q ANY COORDINATION CONCERNS SHALL BE ADDRESSED AT THAT TIME. 9. FIRE ALARM SYSTEM SHALL BE PROVIDED WITH VOICE EVACUATION IN ALL NEW CONSTRUCTION AND RENOVATION AREAS. W N Q 10. PROVIDE CALL BUTTONS,CLOCKS, SPEAKERS,AND ALL REQUIRED ACCESSORIES AND CABLING FORA FULLY FUNCTIONING TELECOR SYSTEM o 0 INTEGRATED INTO THE SCHOOL'S EXISTING SYSTEM. W CONSTRUCTION NOTES Oj NEW ELEVATOR FEEDER TO BE FED FROM THE TOP SPARE 200A FUSIBLE BUCKET IN THE MDP DISTRIBUTION SECTION. O REMOVE THE EXISTING FIRE ALARM CONTROL PANEL AND REPLACE WITH A NEW ADDRESSABLE FIRE ALARM CONTROL PANEL THAT TD& HP1-1 ALLOWS RETROFIT OF USING EXISTING WIRING AND FIRE ALARM DEVICES. SMOKE DETECTORS IN THE ELECTRICAL ROOM AND OUTSIDE Engineering THE ELEVATOR ARE TO BE UPGRADED. SEE PLANS FOR NEW FIRE ALARM DEVICES, INCLUDE UPGRADING AN ADDITIONAL TWENTY (20) H-1 SMOKE AND HEAT DETECTORS, NOT SHOWN ON THE PLANS,TO NEW ADDRESSABLE DETECTORS THROUGHOUT THE BUILDING. IF LESS 1 Wp THAN TWENTY(20) DEVICES ARE UPGRADED, PROVIDE A PRORATED CREDIT IN THE LAST INVOICE OF THE PROJECT. ELECTRICAL RM (E)CT CABINET (E)PANEL F (E) ELEC RANGE 100A DISC. ,` (E) PANEL H 100A DISC. , )PANEL A (E)TELECOMM. H-2.4 [ (E PA L C 1 F DE ARCATION All (E)MDP ELECTRICAL RIM PANEL FIRE ALARM CONTROL PANEL'EST iO64' " 0 (N)❑ (C-19)O ^ O 2 D fll/II ,ENGINEERING (E)METER J j DRAWN BY: NEE / DESIGNED BY: STE I QUALITY CHECK: STE DATE: 12123125 JOB NO. CDSI-2511 FIELDBOOK VA ryl I I I I I I I , SEE E .1 FOR LARGE SCALE PLA S c� w (N)EI Lu N Z in Lu L0 w V > ti Q a Lr) i w Z ; Q CL z 0 N z O Q z za z W a > E w o N W w 00 O N m O m U O d N SURFACE MOUNT CONDUIT PAINTED TO MATCH o THE EXISTING WALL PAINT TO PROVIDE A NEW N PULL STATION WITHIN 5' THE EXTERIOR rn 7 DOOR AT THE TOP OF THE STAIRS. �I vrn (N)F xo X U N} Im QI IN LEVEL ONE FLOOR PLAN - POWER N q ®SCALE: 1/8"=V-0" �N �o �N w �o w z 2511 E1.DWG u— E1.1