Loading...
HomeMy WebLinkAbout002 A0.2 NOTESA7.1 1 A5.1 1 1 A3.1 1 1-1 1-A 1 A4.1 1 A4.1 1 A4.1 DOOR TAG WE-1 F1 R1 12 12 WINDOW TAG WALL TAG FLOOR TAG ROOF TAG ELEVATION MARK REVISION NORTH ARROW BREAK LINE ROOF SLOPE BUILDING SECTION EXTERIOR ELEVATION INTERIOR ELEVATION PARTIAL BUILDING SECTION SECTION DETAIL NOT FOR CONSTRUCTION SHEET NAME SHEET NUMBER PROJECT CODE 111 South Grand Studio 221 Bozeman, MT 59715 406.951.1133 PROJECT NAME PROJECT ADDRESS DATE PROJECT REVISIONS NOTES A0.2 STR South Tracy Residence 1017 South Tracy Avenue Bozeman, MT 59715 12-05-2025 GENERAL NOTES 1. DRAWINGS ARE THE PROPERTY OF THIS ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED AND CONSTRUCTED OR NOT. THESE DOCUMENTS ARE NOT TO BE REPRODUCED IN ANY FORM AND THEY ARE NOT TO BE USED BY THE PROJECT OWNER OR ANY OTHER ENTITY ON ANY OTHER PROJECTS OR FOR ANY EXTENSIOINS, ADDITIONS OR ALTERATIONS TO THE ORIGINAL PROJECT EXCEPT BY WRITTEN AUTHORIZATION AND PERMISSION FROM AND AGREEMENT WITH THIS ARCHITECT. 2. THE ARCHITECT IS NOT RESPONSIBLE FOR ANY UNAUTHORIZED CHANGES MADE TO DRAWINGS. THE PARTY RESPONSIBLE FOR ANY CHANGES TO THE DRAWINGS WILL BE HELD LIABLE FOR ANY CONSEQUENCES ASSCIATED WITH THE CHANGES, 3. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE PROJECT IN ACCORDANCE WITH THE TERMS AND CONDITIONS OF THE OWNER/CONTRACTOR AGREEMENT AND IN CONFORMANCE WITH THE GOVERNING CODES AND ORDINANCES HAVING JURISDICTION OVER THE PROJECT. 4. CONTRACTOR MUST COMPLY WITH THE RULES AND REGULATIONS OF AGENCIES HAVING JURISDICTION AND SHALL CONFORM TO ALL CITY, COUNTY, STATE, AND FEDERAL CONSTRUCTION, SAFTEY, AND SANITARY LAWS, CODES, STATUES AND ORDINANCES. 5. ALL FEES, TAXES, PERMITS, APPLICATIONS, CERTIFICATES OF INSPECTION, AND THE FILING OF ALL WORK WITH GOVERNMENTAL AGIENCIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 6. ANY AMBIGUITIES, DISCREPANCIES, OR CONFLICTS DISCOVERED THROUGH THE USE OF THESE DRAWINGS SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT. FAILURE TO PROVIDE NOTICE TO THE ARCHITECT PRIOR TO ANY SUBSWQUENT CONSTRUCTION ACTIVITY SHALL RELIEVE THE ARCHITECT OF ALL LIABILITIES AND/OR ANY OTHER CONSEQUENCES. 7. DO NOT SCALE THE DRAWINGS, USE DIMENSIONS. LARGER SCALE DRAWINGS SHALL GOVERN SMALLER SCALE. SHOULD DIMENSIONAL ERRORS OCCUR, CONTRACTOR SHALL NOTIFY ARCHITECT PRIOR TO COMMENCEMENT OF THAT PORTION OF THE WORK. 8. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, OMISSIONS, AND/OR CONFLICTS BEFORE PROCEEDING WITH THE WORK. 9. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE, TRUE, AND IN PROPER ALIGNMENT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTIONS OF WORK, FOR WORK INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS, AT NO EXPENSE TO THE ARCHITECT. 11. THE DESIGN, ADEQUACY, AND SAFTEY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ARCHITECT OR ENGINEER. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE THROUGHOUT CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY SIZE AND LOCATIONS OF DUCT AND PLUMBING RUNS WITH MECHANICAL CONTRACTOR PRIOR TO FRAMING WALLS AND CEILINGS. IF DISCREPANCIES OCCUR WITH ARCHITECTURAL DRAWINGS, CONTACT THE ARCHITECT. 13. THERE SHALL BE NO SUBSTITUTIONS OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED UNLESS THE TERMS "EQUAL TO", "EQUIVALENT", OR "APPROVED EQUAL" ARE USED. 14. "TYPICAL" OR "TYP." MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERISTICS TO THE ELEVATION OR DETAIL NOTED, UNLESS NOTED OTHERWISE. VERIFY DIMENSIONS AND ORIENTATIONS OF PLAN. 15. PRIOR TO ORDERING CASEWORK, PLUMBING FIXTURES, LIGHTING FIXTURES, AND CUSTOM METAL WORK, THE CONTRACTOR SHALL FIELD VERIFY DIMENSIONS. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF CONTRACT DOCUMENTS (DRAWINGS, SPECIFICATIONS, ETC.) TO THE TRADES UNDER THEIR JURISDICTION. WHEN EDITS ARE MADE TO DRAWINGS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND THEIR SUBCONTRACTORS TO WORK FROM THE MOST RECENT DOCUMENTS. ANY WORK DONE BASED ON OUTDATED DRAWINGS SHALL BE FIXED BY THE CONTRACTOR AT NO EXPENSE TO THE ARCHITECT. 17. ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN IN ACCORDANCE WITH THE BEST PRACTICES OF THOSE TRADES INVOLVED, AND IN COMPLIANCE WITH BUILDING REGULATIONS AND/OR GOVERNMENTAL LAWS, STATUTES, OR ORDINANCES CONCERNING THE USE OF UNION LABOR. 18. CONSULTANT WORK THAT IS NOT A PART OF THESE CONTRACT DOCUMENTS HAS NOT BEEN COORDINATED BY THE ARCHITECT. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES THAT PREVENT EXECUTION OF WORK COVERED BY THESE DOCUMENTS. GENERAL FRAMING NOTES IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD-FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: 1.1. VERTICALLY AT THE CEILING AND FLOOR LEVELS. 1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM). 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS. 5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19. 6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE SECTIONS R402.4.1 THROUGH R402.4.4 @ AT A.B. ANCHOR BOLT ADJ ADJACENT A.F.F. ABOVE FINISHED FLOOR APPROX APPROXIMATE ARCH ARCHITECT BLDG BUILDING BLKG BLOCKING B.O. BOTTOM OF BOT BOTTOM BTW BETWEEN BTM/BOTT BOTTOM BTWN BETWEEN CAB CABINET C.F. CEMENT FIBER (SIDING AND TRIM)/CUBIC FEET CL CENTERLINE C.B. CATCH BASIN C.C. CENTER TO CENTER CDX EXTERIOR GRADE PLYWOOD C.T. CERAMIC TILE CG CEILING GRILL/CORNER GUARD CH CHANNEL CI CAST IRON/CUBIC INCHESE CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR COL/COLS COLUMN/COLUMNS CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR DBL DOUBLE DIA DIAMETER DN DOWN ABBREVIATIONS OWNERARCHITECT CONTRACTOR VICINITY MAP STEWART ARCHITECTS 111 SOUTH GRAND STUDIO 221 BOZEMAN, MT 59715 PH. (406) 951-1133 SECRET CREEK CUSTOMS BOZEMAN, MONTANA PH. (406) 600-5701 SALE RHODES AND JEREMY NADISON 1514 SOUTH TRACY AVE. BOZEMAN, MT 59715 STRUCTURAL TBD PROJECT TEAM PROJECT ADDRESS: 1017 SOUTH TRACY AVENUE BOZEMAN, MT 59715 LEGAL DESCRIPTION: LANGOHR 1ST ADD, S18, T02 S, R06 E, BLOCK A, Lot 4, ACRES 0.207, PLAT E-31 PROJECT DESCRIPTION: DEMOLITION OF EXISTING SINGLE FAMILY RESIDENCE AND CONSTRUCTION OF A NEW SINGLE FAMILY RESIDENCE ON EXISTING LOT ZONING: R-1, RESIDENTIAL LOW DENSITY DISTRICT DRAWING SYMBOLS DR DOOR DWR DRAWER DTL/DET DETAIL DWG DRAWING EA EACH ELEC ELECTRICAL EQ EQUAL EXT EXTERIOR FDN FOUNDATION FF FINISHED FLOOR FLR/FL FLOOR FLUOR FLUORESCENT FT FOOT OR FEET FTG FOOTING GA GAUGE G.C. GENERAL CONTRACTOR GEN GENERAL G.F.I. GROUND FAULT INTERRUPTOR GLB GLUE LAMINATED BEAM GWB GYPSUM WALL BOARD HB HOSE BIB IN INCH INCL INCLUDE (D) (ING) INFO INFORMATION INSUL INSULATION (ED) (ING) MFR MANUFACTURER MAX MAXIMUM MECH MECHANICAL MDF MEDIUM DENSITY FIBER BOARD MIN MINIMUM MISC MISCELLANEOUS MTL METAL NTS NOT TO SCALE O.C. ON CENTER PL PLATE PLAM PLASTIC LAMINATE PLWD PLYWOOD PSL PARALLEL STRAND LUMBER P.T. PRESSURE TREATED QTY QUANTITY REQD REQUIRED RM ROOM RO ROUGH OPENING R&S ROD AND SHELF SF SQUARE FEET SHTG SHEATHING SHWR SHOWER SIM. SIMILAR SPEC SPECIFICATIONS STRUCT STRUCTURAL SSD SEE STRUCTURAL DRAWINGS TEL TELEPHONE TEMP TEMPERATURE T&G TONGUE AND GROOVE THRU THROUGH TV TELEVISION TYP TYPICAL UG UNDERGROUND UNO UNLESS NOTED OTHERWISE VAR VARIES VB VAPOR BARRIER VERT VERTICAL VG VERTICAL GRAIN W/ WITH W/O WITH OUT WD WOOD W/D WASHER/DRYER WH WATER HEATER WP WATERPROOF BUILDING USE: RESIDENTIAL CONSTRUCTION TYPE: V-B NON-RATED FIRE SUPPRESSION: N/A PROJECT DATA PROJECT TEAM INSULATION REQUIREMENTS CODE SUMMARY AREA PRELIMINARY FIXTURES AND FINISHES GROSS SQUARE FOOTAGE FIRST FLOOR 1718 SF GUEST SUITE 261 SF SECOND FLOOR 1001 SF TOTAL 2980 SF GARAGE 624 SF 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL BUILDING CODE 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL FUEL GAS CODE 2021 UNIFORM PLUMBING CODE 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE 2020 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE (IFC) ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES BOZEMAN UNIFIED DEVELOPMENT CODE ARM MODIFICATIONS TO THE ADOPTED BUILDING CODES Number Date PROJECT LOCATION