HomeMy WebLinkAbout13- OVERALL SITE PLANOHPOHPOHPOHPOHPOHPOHPOHPOHPSSWAT
WAT
WAT
WAT
WAT
WAT
WAT
WAT
WAT
WAT
WAT WAT WAT WAT WAT WAT
SEW
SEW
SEW
SEW
SEW
SEW
SEW
SEW
SEW
SEW
SEW SEW
SEW SEW SEWSEW SEWSEWSEWSEWSEWSEWSEWSEWSEW
HYD6''WSOUTH CHURCH STREETBOZEMAN CREEKWATWATWATWATS2''FM2''FM2''FM2''FM2''FM2''FM2''FM2''FM2''FM2''FM2''FM
2''W
2''W2''W2''W2''W6''WHYD1''W>>>>>>>>>S4840
4840
48454845
48500'20'40'60'C1.0AS NOTEDOVERALL SITE PLANBMHEC Aug 07, 2025 - 3:43pmCAD FILE: M:\213596\Drawings\_Subdivision Review\C 1.0.dwg
REVISIONSDATEPROJECT NUMBERHYALITE Engineers, PLLC161 W. Haley Springs RoadBozeman, MT 59715Tel: (406) 587.2781w w w . hyaliteeng. comFax: (406) 522.92252021705 SOUTH BOZEMAN, MT8.7.202521359622x34 ORIGINALS CHURCH AVENUESCALESHEET TITLEDESIGN BYSte. 101MONTANABRETT C.No. 29106 PEMEGAARDPEFORSOILNASRENI
G
ENE PROPERTY LINEEXISTING OVERHEAD POWEREXISTING 8" SEWER MAINPROPOSED 4" SDR 26 PVC SEWER SERVICEPROPOSED 1.5" DR 9 FORCE MAINEXISTING 6" CAST IRON WATER MAINEXISTING WATER SERVICE LINEPROPOSED 2" COPPER WATER SERVICEEXISTING SIDEWALKPROPOSED SIDEWALK/WALKWAYFINISHED GROUND ELEVATIONEXISTING HYDRANTEXISTING SANITARY SEWER MANHOLEEXISTING VALVEEXISTING POWER POLEMASTER LINE & SYMBOL LEGEND1000OHP8''S6''WWATSHYD2''WSEW2''FMEXISTINGSEWERMAINEXISTINGWATERMAINPROPOSED 2" WATER SERVICEEXISTINGFIREHYDRANT-TO BERELOCATED705 S CHURCHLEGAL DESCRIPTIONBEING BOOK 156 OF FILMS, PAGE 4066, LOCATED IN PORTIONS OF THE SW 14 OF THE SE 14SECTION 7, TOWNSHIP 2 SOUTH, RANGE 6 EAST, P.M.M. CITY OF BOZEMAN, GALLATINCOUNTY, MONTANA.ABANDONEXISTINGWATERSERVICEPROPOSED DRIVEWAYPROPOSED STORM PONDAPPROX. 951 CF STORAGE(GRADE DITCH/PIPING TODRAIN TO LOCATION)EXISTING DELINEATEDFLOODPLAINEXISTING WATERWAYEXISTING FLOODPLAINEXISTING FLOODWAYSTORMWATER DITCH OR 6 IN. DIA. PIPE TOCONVEY PARKING SURFACE RUNOFF ANDROOF DRAINAGE STORMWATER (SLOPE AT0.50% TO ENSURE ADEQUATE DRAINAGE)COORDINATEWITH NWEON DEMO& NEW UTIL.PROPOSED 1.5" FORCE MAINTO BE PRIVATELYMAINTAINEDPROPOSED BORE AND SLEEVEUNDER BOZEMAN CREEKPROPOSEDGRINDER PUMPBASINPROPOSEDCLEANOUT (TYP.)PROPOSED4-BEDROOMTOWNHOMEPROPOSED5-BEDROOMTOWNHOMEPROPOSED 8"X4" SEWERSERVICE INSERTA TEEAPPROX. PROPERTYBOUNDARY (TYP.)PROPOSED STORM PONDAPPROX. 887 CF STORAGE(GRADE DOWNSPOUTS TODRAIN TO LOCATION VIA SWALES)PROPOSED SIDEWALKTIE INTO EXISTINGSIDEWALKPROPOSED30'SEWEREASEMENTPROPOSED 213' BORE AND SLEEVE UNDER BOZEMAN CREEKPROPOSED 4" SEWERSERVICE TO BEMAINTAINED BY THECITY OF BOZEMANCONTROL PANELTO BE MOUNTEDTO TOWNHOMENOTES:THE SEPTIC TANK, GRINDER PUMPBASIN AND FORCE MAINS WILL BEPRIVATELY MAINTAINEDLOT: 126436 SQFT0.61 ACLOT 2:34298 SQFT0.79 ACPROPOSED 1"WATER SERVICEEXISTING GEO-REFERENCEDFLOODPLAIN75' WATERCOURSESETBACK FROM HIGHWATER MARK75' WATERCOURSESETBACK FROM HIGHWATER MARK