Loading...
HomeMy WebLinkAbout088.1-EPS1.0-ELECTRICAL PHOTOMETRIC PLAN -STREETW V W V W VW V W V W VW V W V SS SS W VHY DHY D H YDHY DW VW VW V SS SS ST W V W V W V W V W VW V ST WBO HY D ELEC W VW VW V HY DW V W VW VW VW VW VHY DH YDHYD T P T P T P T P T P T P T P COCOCO 0.5 0.8 1.1 1.0 0.6 0.9 1.0 0.9 0.5 0.7 1.0 1.1 1.1 0.9 0.8 1.1 1.3 1.4 1.4 0.9 1.1 1.2 1.4 1.6 1.0 1.1 0.9 0.8 0.6 0.7 0.8 0.9 0.9 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.8 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.5 0.7 1.0 1.2 1.4 1.6 1.7 1.7 1.6 0.7 0.8 0.8 0.9 0.9 0.8 0.8 0.7 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.5 0.7 0.8 0.9 1.1 1.3 1.4 1.20.8 0.8 0.8 0.8 0.8 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.3 0.2 1.1 1.1 1.0 1.0 0.9 0.8 0.7 0.6 0.6 0.6 0.5 0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.8 0.8 0.7 0.6 0.6 0.5 0.5 0.6 0.7 0.6 0.6 0.5 0.4 BUILDING "A" BUILDING "B" BUILDING "C" EF E30 E30 E30 E30 E30 E31 EXISTING LIGHT (E) EF EF EDGERTON AVENUEGABRIEL AVENUEMEAH LANE MEAH LANE MEAH LANE FOWLER LANEFOWLER LANENOTE: FOWLER LANE IS A MINOR ARTERIAL, PER CITY OF BOZEMAN PUBLISHED STANDARDS. CALCULATIONS ARE DESIGNED AS SUCH. NOTE: FOWLER LANE IS A MINOR ARTERIAL, PER CITY OF BOZEMAN PUBLISHED STANDARDS. CALCULATIONS ARE DESIGNED AS SUCH. E30 E30 edinc Job #:24.115AN AFFORDABLE HOUSING DEVELOPMENT:172 Timberwolf PkwyKalispell, MT 59901(406) 752-22162025 ENCOMPASS DESIGN INC.C BUILDING PERMIT REVIEW SET: 08/13/2025 EPS1.0 ELECTRICAL PHOTOMETRIC PLAN - STREETBOZEMAN, MONTANAROCKY MOUNTAIN FLATSN SCALE: 1" = 50'-0" ELECTRICAL PHOTOMETRIC PLAN -STREET1 1. 2. 3. 4. PRIOR SUBMITTAL NOT REQUIRED. ALL ALTERNATE FIXTURE SHOP DRAWINGS WILL BE REVIEWED AFTER THE PROJECT IS AWARDED. PRIOR SUBMITTAL IS REQUIRED. ALTERNATE FIXTURE IS NOT ACCEPTED FOR SUBSTITUTIONS. VERIFY FINISH WITH ARCHITECT PRIOR TO ORDERING, -PROVIDE FINISH PER CITY OF BOZEMAN REQUIREMENTS. A. B. ALL LUMINAIRES SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) SUCH AS UL OR ETL. ALL LUMINAIRES SHALL HAVE DESIGN LIGHTS CONSORTIUM (DLC) CERTIFICATION AND/OR ENERGY STAR RATING. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALL MOUNTING, FIRE-RATED, AND IC-RATED ACCESSORIES AS NOTES: GENERAL NOTES: STREET LUMINAIRE SCHEDULE TYPE LAMPS LOAD (W) OUTPUT (LM, NOMINAL)EFFICACY CCT (K)DESCRIPTION MFR CATALOG NO. OR SERIES FINISH MOUNTING VOLTAGE NOTES (E) LED 0 W NA NA NA EXISTING LIGHT NA NA NA NA 208 V NA E30 LED 30 W 3,238 112 2,700 SINGLE HEAD LED POLE MOUNTED STREET LIGHT ON A 25' POLE WITH 6' ARM. PROVIDE CONCRETE BASE PER CITY OF BOZEMAN DESIGN STANDARDS. LUMEC RFS-30W16LED2-7K-G2-R2M TBD POLE/ 25' 208 V 2,4 E31 LED 40 W 4,138 109 2,700 SINGLE HEAD LED POLE MOUNTED STREET LIGHT ON A 30' POLE WITH 10' ARM. ARM. PROVIDE CONCRETE BASE PER CITY OF BOZEMAN DESIGN STANDARDS. LUMEC RFS-35W16LED2-7K-G2-R2M TBD POLE/ 30' 208 V 2,4 EF LED 0 W TBD TBD TBD FUTURE LIGHT TBD TBD TBD TBD 208 V TBD