HomeMy WebLinkAbout088.1-EPS1.0-ELECTRICAL PHOTOMETRIC PLAN -STREETW V W V W VW V W V
W VW V W V
SS
SS
W VHY DHY D
H YDHY DW VW VW V
SS SS
ST
W V
W V
W V
W V
W VW V
ST
WBO HY D
ELEC W VW VW V
HY DW V
W VW VW VW VW VHY DH
YDHYD
T P
T P
T P
T P
T P
T P
T P
COCOCO
0.5 0.8 1.1 1.0
0.6 0.9 1.0 0.9 0.5
0.7 1.0 1.1 1.1 0.9
0.8 1.1 1.3 1.4 1.4
0.9 1.1 1.2 1.4 1.6
1.0 1.1 0.9 0.8
0.6
0.7
0.8
0.9
0.9
0.8
0.8
0.8
0.9
0.9
0.9
0.9
0.9
0.8
0.7
0.6
0.6
0.5
0.5
0.4
0.4
0.4
0.4
0.3
0.3
0.4
0.5
0.7
1.0
1.2
1.4
1.6
1.7
1.7
1.6
0.7
0.8
0.8
0.9
0.9
0.8
0.8
0.7
0.8
0.8
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.5
0.5
0.4
0.4
0.5
0.7
0.8
0.9
1.1
1.3
1.4
1.20.8
0.8
0.8
0.8
0.8
0.7
0.6
0.6
0.5
0.5
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.7
0.6
0.5
0.5
0.4
0.4
0.4
0.4
0.4
0.3
0.2
1.1
1.1
1.0
1.0
0.9
0.8
0.7
0.6
0.6
0.6
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.8
0.8
0.7
0.6
0.6
0.5
0.5
0.6
0.7
0.6
0.6
0.5
0.4
BUILDING "A"
BUILDING "B"
BUILDING "C"
EF
E30
E30
E30
E30
E30
E31
EXISTING LIGHT
(E)
EF
EF
EDGERTON AVENUEGABRIEL AVENUEMEAH LANE
MEAH LANE
MEAH LANE
FOWLER LANEFOWLER LANENOTE: FOWLER LANE IS A MINOR
ARTERIAL, PER CITY OF BOZEMAN
PUBLISHED STANDARDS. CALCULATIONS
ARE DESIGNED AS SUCH.
NOTE: FOWLER LANE IS A MINOR
ARTERIAL, PER CITY OF BOZEMAN
PUBLISHED STANDARDS. CALCULATIONS
ARE DESIGNED AS SUCH.
E30
E30
edinc Job #:24.115AN AFFORDABLE HOUSING DEVELOPMENT:172 Timberwolf PkwyKalispell, MT 59901(406) 752-22162025 ENCOMPASS DESIGN INC.C
BUILDING PERMIT REVIEW SET:
08/13/2025
EPS1.0
ELECTRICAL
PHOTOMETRIC
PLAN - STREETBOZEMAN, MONTANAROCKY MOUNTAIN FLATSN SCALE: 1" = 50'-0"
ELECTRICAL PHOTOMETRIC PLAN -STREET1
1.
2.
3.
4.
PRIOR SUBMITTAL NOT REQUIRED. ALL ALTERNATE FIXTURE SHOP DRAWINGS WILL BE REVIEWED AFTER
THE
PROJECT IS AWARDED.
PRIOR SUBMITTAL IS REQUIRED.
ALTERNATE FIXTURE IS NOT ACCEPTED FOR SUBSTITUTIONS.
VERIFY FINISH WITH ARCHITECT PRIOR TO ORDERING, -PROVIDE FINISH PER CITY OF BOZEMAN
REQUIREMENTS.
A.
B.
ALL LUMINAIRES SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) SUCH AS UL OR ETL.
ALL LUMINAIRES SHALL HAVE DESIGN LIGHTS CONSORTIUM (DLC) CERTIFICATION AND/OR ENERGY STAR RATING.
THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALL MOUNTING, FIRE-RATED, AND IC-RATED ACCESSORIES AS
NOTES: GENERAL NOTES:
STREET LUMINAIRE SCHEDULE
TYPE LAMPS
LOAD
(W)
OUTPUT
(LM, NOMINAL)EFFICACY
CCT
(K)DESCRIPTION MFR CATALOG NO. OR SERIES FINISH MOUNTING VOLTAGE NOTES
(E) LED 0 W NA NA NA EXISTING LIGHT NA NA NA NA 208 V NA
E30 LED 30 W 3,238 112 2,700 SINGLE HEAD LED POLE MOUNTED STREET LIGHT ON A 25' POLE WITH 6' ARM.
PROVIDE CONCRETE BASE PER CITY OF BOZEMAN DESIGN STANDARDS.
LUMEC RFS-30W16LED2-7K-G2-R2M TBD POLE/ 25' 208 V 2,4
E31 LED 40 W 4,138 109 2,700 SINGLE HEAD LED POLE MOUNTED STREET LIGHT ON A 30' POLE WITH 10' ARM.
ARM. PROVIDE CONCRETE BASE PER CITY OF BOZEMAN DESIGN STANDARDS.
LUMEC RFS-35W16LED2-7K-G2-R2M TBD POLE/ 30' 208 V 2,4
EF LED 0 W TBD TBD TBD FUTURE LIGHT TBD TBD TBD TBD 208 V TBD