Loading...
HomeMy WebLinkAbout069-B-A2.12-BUILDING B -THIRD LEVEL FLOOR PLAN - AREA BSTOR. B316 (TYPE B) 3/2-B1 B307 (TYPE B) 3/2-B1 MIRR B308 (ACC) 2/1-ACC-MIRR B309 (TYPE B) 4/2-B1 MIRR B310 (TYPE B) 3/2-B1 B312 (TYPE B) 1/1-B1 B313 (TYPE B) 4/2-B2 B315 (TYPE B) 4/2-B2 MIRR B314 STAIR 1 S302 ELEV. E301 CORRIDOR 1 C301 ELEV. LOBBY B318 CORRIDOR 2 C302 JAN. B317 (TYPE B) 3/2-B1 B311 DATA B319 1L LMOOQQRRTTVVWWNNPPSSUU13 18121517 19 20141611 M2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2036'-0"8'-0"11'-0"25'-0"25'-0"5'-0"158'-0" 46'-0"67'-0"7'-0"30'-0"89'-0" 11'-0"25'-0"10'-0"43'-0"37'-0"23'-0"21'-0"25'-0"43'-0"12'-0"AREA A AREA B AREA A AREA B 1A4.41A4.61A4.51A4.324'-0"19'-0"13'-0"37'-0"5'-0"5'-0"34'-0"24'-0"24'-0"8'-0"13'-0"24'-0"31'-0"6'-0"55'-0"6'-0"31'-0"34'-0"24'-0"8'-0" 10'-0"10'-0"23'-0"24'-0"10'-0"6'-0"DNUP3'-512"6'-1"12'-612"7'-612"5'-512"17'-6"4'-1" 7'-534"4'-914"8'-512"24'-0"7'-534"7'-312"6'-6"HSSSCALE :1 Building Type 2 - Third Level Floor Plan - Area B 1/8" = 1'-0"N C301-1 B316-1 C319-1 B317-1 S302-1 A6.6 3 A6.7 3 A A A A B A A A A A A A A B A A A A B B A A B B A A A A A A A B A A A H # # ALT SEE COVER SHEET FOR INFORMATION ON ALTERNATEROOM NAME ROOM NUMBER DOOR TAG - SEE SCHEDULE ON A0.5 WINDOW TAG - SEE SCHEDULE ON A0.5 INTERIOR WALL TYPES - SEE A0.2 FOR WALL ASSEMBLY GRID LINE EXTERIOR WALL - SEE A0.2 FOR WALL ASSEMBLY, SEE ELEVATIONS FOR SIDING TYPE FD FLOOR DRAIN, SEE PLUMB. DOWN SPOUT, SEE ROOF PLAN DS HOSE BIB, SEE PLUMB.HB 1 # A#.# XXX XXX LEGEND - FLOOR PLANS I-# X ROOM2 ROOM1 RM# N XXX S W E ###-# E-# INTERIOR ELEVATION NUMBER SHEET NUMBER DETAIL REFERENCE LOCATION DETAIL DRAWING NUMBER DETAIL SHEET NUMBER ACCESSIBLE UNIT, SEE UNIT PLANS & A5'S FOR ADDITIONAL INFO # XXX EXTERIOR ELEVATION SHEET NUMBER EXTERIOR ELEVATION DRAWING # SECTION DRAWING # EXTERIOR ELEVATION SHEET NUMBER STANDPIPE, SEE FIRE SUPPR. NON-RATED WALL 1/2 HR FIRE RESISTANT RATED CONSTRUCTION, SEE ASSEMBLIES FOR MORE INFO 1 HR FIRE RESISTANT RATED CONSTRUCTION, SEE ASSEMBLIES FOR MORE INFO 2 HR FIRE RESISTANT RATED NON-COMBUSTIBLE CONSTRUCTION, SEE ASSEMBLIES FOR MORE INFO FIRE RATED CONSTRUCTION DESIGNATION SYMBOL DESIGNATION FIRE EXTINGUISHER, SEE CODE PLANS APPLIANCE TAG - SEE SCHEDULE ON A0.5 GENERAL NOTES - FLOOR PLANS A.SEE A0.0a FOR ALTERNATES LIST. B.SEE CODE SHEETS FOR FURTHER REQUIREMENTS. C.SEE PROJECT MANUAL FOR PRODUCT SPECIFICATIONS. D.USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. E.DIMENSIONS ARE FROM FACE OF STUD AT NEW WALLS. SEE WALL TYPES FOR ADDITIONAL WALL ASSEMBLY INFORMATION. F.SET DOOR ROUGH OPENINGS 3" FROM F.O.S., TYP. U.N.O. CENTER CLOSET DOOR ALONG LENGTH OF CLOSET. G.SEE UNIT PLANS FOR ADDITIONAL DIMENSIONS. H.SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING & SHEAR WALLS. I.COORDINATE ALL COLUMN LOCATIONS AND SIZES WITH STRUCTURAL DRAWINGS. J.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE RODS, ETC. BACKING TO BE INCLUDED IN ALL UNITS ON ALL FLOORS TO COMPLY WITH "ADA" ADAPTABILITY. REFER TO INTERIOR ELEVATIONS FOR FURTHER INFORMATION REGARDING TOILET & TUB/SHOWER BLOCKING, TYPICAL. K.SEE RCP, ELECTRICAL & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS & LIGHTING. L.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS. M.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR FLOOR SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS. N.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE ADDITIONAL LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH, UNIFORM FINISHED SURFACE FOR ENTIRE LENGTH OF WALL. O.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ OWNER. P.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP. Q.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER HEATER ROOMS, ETC). USE ADDITIONAL LAYERS OF GWB AS REQ'D TO NOT INTERRUPT RATINGS OF WALLS. R.SEE A5.1 & A5.2 FOR ALL ACCESSIBLE DETAILS & TYPICAL CASEWORK DIMENSIONS FOR THIS FLOOR. S.SHELF MOUNTING HEIGHTS TO BE MAX 48" A.F.F. IN THE CODE REQUIRED ACCESSIBLE UNITS AND 64" A.F.F. IN ALL OTHER UNITS. SEE ACCESSIBLE MOUNTING HEIGHTS ON A5's. T.SEE A5's FOR BATHROOM AND KITCHEN INTERIOR ELEVATIONS. U.SEE A7's FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS. V.SEE A7's FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS. W.SEE A8's FOR DOOR AND WINDOW DETAILS. X.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES. Y.PROVIDE P.T. PLATES AT ALL WALLS ADJACENT TO CEMENTIOUS MATERIAL. Z.CARBON MONOXIDE DETECTORS REQUIRED IN EACH UNIT, COORDINATE WITH ELECTRICAL. SEE SPECS. AA.PORTABLE FIRE EXTINGUISHERS REQUIRED IN ALL UNITS & COMMUNITY ROOM. G.C. TO VERIFY TYPE & SIZE W/ CITY AHJ & FINAL LOCATION WITH ARCHITECT. 1.FUR WALL FOR ELECT. METERS & FEEDER LINES, SEE ELECTRICAL DWGS. EXTERIOR SIDE OF WALL TO BE FINISHED W/ EXTERIOR MATERIALS. SEE EXT. ELEV. 2.OPEN FACED DOWNSPOUT. ALL RAIN LEADERS TO BE EXPOSED ON EXTERIOR OF WALL. SEE EXT. ELEV. AND ROOF PLAN FOR MORE INFORMATION. 3.PROPOSED FDC, VERIFY EXACT LOCATIONS WITH LOCAL AHJ. 4.MOP SINK (SEE PLUMBING DRAWINGS) W/ FRP LOCATED BEHIND SINK ON BOTH WALL (4' HEIGHT & FULL LENGTH OF WALL. PROVIDE AND INSTALL (1) MOP/BROOM HOLDER - WITH SHELF AT EACH MOP SINK LOCATION. COLOR TO BE WHITE. SEE SPECS AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 5.HOSE BIB LOCATION, COORDINATE WITH PLUMBING DRAWINGS. REPORT ANY DISCREPANCIES TO THE ARCHITECT. 6.PROVIDE FURROUT WALL FOR PLUMBING ADJACENT TO FIRE RESISTANT RATED WALLS, BARRIERS OR PARTITIONS. 7.FIRE PUMP, FIRE RISER & WATER SERVICES LOCATION. SEE PLUMB, FIRE AND CIVIL. 8.FLOOR DRAIN. SEE ENLARGED FLOOR PLANS AND PLUMBING PLANS FOR LOCATIONS. 9.4'-0" REQUIRED LANDING @ DOOR ENTRY - MAX 2% SLOPE. PAST THE LANDING, SLOPE PER CIVIL - MAX 5% SLOPE. COMPACT SUBGRADE PER SOILS REPORT. 10.ELEVATOR. SEE ELEVATOR DETAILS AND SPECIFICATIONS. 11.STRUCTURAL COLUMN, SEE STRUCTURAL. 12.CANOPY OR ROOF BELOW. SEE ROOF PLAN. 13.COLUMNS SUPPORTING RATED WALLS ABOVE TO BE 2 HR FIRE RATED SEPARATE FROM WALL. AT COMMUNITY ROOM, TRIM AROUND COLUMN W/ WOOD TRIM. MATCH TRIM AT WALL TO ALIGN WITH COLUMNS. 14.WALL OPENING FOR ACCESS TO ELECTRICAL GEAR ALCOVE. FINISH JAMBS W/ EXTERIOR TRIM PER EXT. ELEV. 15.SURFACE MOUNTED FIRE EXTINGUISHER CABINET. SEE CODE PLANS AND SPECS FOR ADD'L INFORMATION. 16.ELECTRICAL METER STACKS, BREAKERS, HOUSE EQUIPMENT, ETC.. SEE ELECTRICAL. T.O. EQUIPMENT TO BE BELOW WINDOW SILL. 17.2 HR FIRE RESISTANT RATED BARRIER FROM FLOOR SLAB TO ROOF DECK W/ HORIZONTAL EXIT ON HOLD OPENS TIED TO FIRE ALARM SYSTEM. SEE CODE SHEETS. 18.SOLID SURFACE COUNTERTOP. 34" A.F.F. MAX HEIGHT. 19.RECEPTION DESK W/ SOLID SURFACE COUNTERTOP. SERVICE COUNTERTOP TO BE AT 34" A.F.F. DESK BEHIND SERVICE COUNTERTOP TO BE AT 30" A.F.F. PROVIDE W/ COILING, LOCKING OVERHEAD DOOR 20.KITCHEN ISLAND W/ 2x6 WALL UNDER TO SUPPORT. PROVIDE MICROWAVE SHELF W/ CASEWORK AT END OF ISLAND. 21.2x CEDAR WOOD SCREEN WALL. SEE EXT. ELEV. KEYED NOTES - FLOOR PLANS# UNIT NOMENCLATURE KEY 2/1-B1-A/V # OF BEDROOMS # OF BATHROOMS ACCESSIBILITY TYPE: ACC = FULLY ACCESSIBLE (ICC A117.1) + MEETING UFAS REQUIREMENTS A = TYPE A ACCESSIBLE (ICC A117.1) B = TYPE B ADAPTABLE (ICC A117.1) S = STANDARD (NO ACCESSIBILITY REQ'D) TYPE OF LAYOUT DENOTES AUDIO / VISUAL COMMUNICATIONS REQ'D3'-0"3'-8"6'-0"6'-0"12'-6"5'-6"4'-0"15'-0"6'-9"6'-3"6'-1"11'-0"16'-2"3'-9"6'-0"6'-0"12'-6"5'-6"4'-0"19'-0"18'-0" 5'-6"12'-6"6'-0"6'-0"13'-8"6'-0"6'-0"10'-6"10'-9"3'-9"3'-9"16'-10"13'-10"16'-10"3'-9"3'-9"6'-0" 12'-0"6'-0"12'-6"5'-6"4'-0"4'-0" 6'-6"6'-6"6'-0"12'-0"6'-0"6'-0"10'-6"10'-9"3'-9"12'-0"12'-3"6'-0" ℄ ℄ ℄ ℄ ℄ ℄ ℄ ℄ ℄℄℄℄ ℄℄ ℄℄℄℄℄℄ ℄ ℄ ℄ ℄ ℄℄℄℄℄℄℄ ℄ ℄ ℄ ℄ 6'-0" ℄℄ 6'-6"7'-6"4'-0"℄℄ 8'-4"℄ 17I-7 E-2 I-7 I-7I-717 I-7 4 I-2 I-3 I-3 I-2 I-2 E-2 10 12 12 2 2 I-3 E301-1BUILDING TYPE 2 - THIRD LEVEL FLOOR PLAN - AREA B B-A2.12 24.115edinc Job #: 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design + architecture inc THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. SITE PLAN REVIEW: 05/29/2025 REV. 01: SP RESUBMITTAL #1 2025 ENCOMPASS DESIGN INC.C AN AFFORDABLE HOUSING DEVELOPMENT:ROCKY MOUNTAIN FLATSBOZEMAN, MONTANAB AREA PLAN KEY - BLDG TYPE 2 STATEOF M O N T ANA D ARCHT EBRYAN O. TOPP 16058LICENSE TCI MISSOULA, MT ''''''''''''''''''''''' ' ' ''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''' •••••••••••••• • • ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••