Loading...
HomeMy WebLinkAbout055-A-A2.18-BUILDING A -ROOF PLAN -AREA A1 2 3 4 8 14 17 206 14 17 20BEFA10121113 13 15 15 16 16 18 18 19 19CDHJIG NNK7 12 5 9 332'-0" 46'-0"36'-0"36'-0"44'-0"44'-0"25'-0"30'-0"40'-0"198'-0" 15'-0" 36'-0"44'-0" AREA A AREA C AREA A AREA C AREA AAREA BAREA AAREA BMM2 A4.3 2A4.11/4":12"1/4":12"1/4":12"1":12"V A L L E Y VALLEY VALLEYVALLEY SCALE :1 Building Type 1 - Roof Plan - Area A 1/16" = 1'-0"N BUILDING #A, BUILDING #C # ALT SEE COVER SHEET FOR INFORMATION ON ALTERNATE GRID LINE1 # A#.# XXX XXX LEGEND - ROOF PLANS DETAIL REFERENCE LOCATION DETAIL DRAWING NUMBER DETAIL SHEET NUMBER # XXX EXTERIOR ELEVATION SHEET NUMBER EXTERIOR ELEVATION DRAWING # SECTION DRAWING # EXTERIOR ELEVATION SHEET NUMBER D-100 ROOF SLOPE R#ROOF ASSEMBLY TYPE, SEE A0.2 FOR ASSEMBLY INFO. OPEN FACED DOWNSPOUT THRU-WALL SCUPPER STANDING SEAM METAL ROOF, SEE SPECS MEMBRANE ROOF, SEE SPECS 2 HR FIRE RESISTANT RATED CEILING / ROOF ASSEMBLY. WALLS TO TERMINATE AT CEILING MEMBRANE ROOF FINISH KEY CONDUCTOR HEAD 1.MECHANICALLY FASTENED TPO ROOFING MEMBRANE, INSTALL IN STRICT CONFORMANCE TO MFR INSTRUCTIONS, SEE SPECIFICATIONS. VERIFY ALL CONDITIONS. 2.2 HR FIRE RESISTANCE RATED BARRIERS BELOW TO EXTEND FULL HEIGHT TO UNDERSIDE OF 2 HR FIRE RESISTANCE RATED CEILING MEMBRANE. 3.MECHANICAL EQUIPMENT, VERIFY WITH MECHANICAL DRAWINGS. PROVIDE EQUIPMENT PAD, STEEL ANGLES, PIPING, ROOF PENETRATIONS, FLASHING AS REQ'D. BY MECHANICAL. COORDINATE WITH MECH. & STRUCT. DWGS. 4.CRICKETS AS REQUIRED, VERIFY ALL CONDITIONS. MIN SLOPE 1/4" / FOOT. 5.THRU WALL SCUPPER, COORDINATE LOCATIONS W/ PLUMBING & STRUCTURAL DRAWINGS. SEE DETAILS A8s. HEIGHT TO INCORPORATE OVERFLOW. 6.PARAPET W/ METAL CAP. TPO TO WRAP UP & OVER PARAPET WALLS, TYPICAL. 7.RADON PIPE, SEE MECHANICAL PLANS. 8.GUTTERS AND DOWNSPOUTS ON ALL LOWER ROOFS. SEE DETAIL ON A8s. 9.METAL ROOFING, SEE DETAILS A8s. 10.TPO TO WRAP UP SIDES OF ELEVATOR AND/OR STAIR PENTHOUSE SHAFT, TYP ALL SIDES. 11.CLASS I STANDPIPE LOCATION (VERIFY EXACT CLASS, LOCATION, SIZE AND ALL REQUIREMENTS WITH LOCAL AHJ). SEE FIRE SUPPRESSION. 12.CONDUCTOR HEAD TO OPEN FACED METAL DOWNSPOUT, SEE EXT. ELEV. DETAILS ON A8s & PLUMBING. 13.ROOF-TO-WALL FLASHING & COUNTER FLASHING. SEE DETAILS OF A8's 14.SIDE WALL STEPPED FLASHING. SEE DETAILS ON A8's 15.CANOPY WITH TIE RODS. SEE DETAILS ON A8's & STRUCTURAL. 16.TPO WALKING PAD. INSTALL PER MFR. 17.METAL SNOW GUARD PAINTED TO MATCH ROOF. PROVIDE TWO SNOW GUARDS PER LOCATION. 18.PLUMBING / MECHANICAL / ELECTRICAL PENETRATION. SEE MEP DRAWINGS. PROVIDE BOOT AND OR FLASHING PER DETAILS ON A8's KEYED NOTES - ROOF PLANS# GENERAL NOTES - ROOF PLANS A.GENERAL CONTRACTOR TO COORDINATE WITH STRUCTURAL DRAWINGS & NOTIFY ARCHITECT OF DISCREPANCIES. B.SEE A8. SHEETS FOR ROOF DETAILS. C.SEE MECHANICAL DRAWINGS FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS. D.ROOFS WITH A SLOPE OF 3:12 OF LESS TO BE COVERED WITH ICE & WATER SHIELD IN IT'S ENTIRETY. E.ROOF CRICKET SLOPE TO BE MINIMUM OF 1:12. F.PROVIDE CONCRETE SPLASH BLOCK AT EACH DOWNSPOUT, U.N.O. VERIFY COLOR WITH ARCHITECT. G.PLUMB & MECH VENTS TO BE GROUPED ORDERLY & NEATLY ON ROOF, SPACED PER CODE REQUIREMENTS & PAINTED. VERFIY COLOR W/ OWNER / ARCHITECT. H.CONCEALED SPACES INCLUDING ROOF & FLOOR TRUSSES TO BE FILLED WITH BLOWN-IN INSULATION OR BE PROVIDED WITH FIRE SPRINKLER HEADS WITHIN CONCEALED SPACES PER NFPA 13. 1 TYP. R-1 3 TYP. 12 13 1414 8 5 R-2 125 6 TYP. 4 4 4 4 4 4 16 TYP. 16 TYP. 6TYP. 6TYP. 1 TYP. R-1 R-3 *4'-0"1'-0"17 18 18 18 18 7 7 18 18 18 18 18 A-A2.18 BUILDING TYPE 1 - ROOF PLAN - AREA A 24.115edinc Job #: 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design + architecture inc THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. SITE PLAN REVIEW: 05/29/2025 REV. 01: SP RESUBMITTAL #1 2025 ENCOMPASS DESIGN INC.C AN AFFORDABLE HOUSING DEVELOPMENT:ROCKY MOUNTAIN FLATSBOZEMAN, MONTANAA AREA PLAN KEY - BLDG TYPE 1 STATEOF M O N T ANA D ARCHT EBRYAN O. TOPP 16058LICENSE TCI MISSOULA, MT ''''''''''''''''''''''' ' ' ''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''' •••••••••••••• • • ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••