Loading...
HomeMy WebLinkAbout019-C6.3-DETAILSXref ..\..\..\..\..\Standards\Civil 3D\Base Maps\City of Bozeman\Bozeman Vicinity Map 2024.dwg 749-01Alpine Job #: THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. 2025 ENCOMPASS DESIGN INC.C AN AFFORDABLE HOUSING DEVELOPMENT:ROCKY MOUNTAIN FLATSBOZEMAN, MONTANA1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 24.115edinc Job #: SITE PLAN REVIEW: 05/29/2025 REV. 02: SP RESUBMITTAL #2 C6.3 DETAILS ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 12.50' OF ADSPLUS625 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS NOTES •THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. •NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE. STORMTECH SC-160 LP SYSTEM 2-22SCALE: NTS CONCEPTUAL ELEVATIONS MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67 MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67 TOP OF STONE:2.00 TOP OF SC-160LP CHAMBER:1.50 8" x 8" BOTTOM MANIFOLD INVERT:0.58 8" x 8" BOTTOM MANIFOLD INVERT:0.58 8" ISOLATOR ROW PLUS INVERT:0.58 8" ISOLATOR ROW PLUS INVERT:0.58 BOTTOM OF SC-160LP CHAMBER:0.50 BOTTOM OF STONE:0.00 PROPOSED LAYOUT STORMTECH SC-160LP CHAMBERS STORMTECH SC-160LP END CAPS STONE ABOVE (in) STONE BELOW (in) STONE VOID INSTALLED SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED) (COVER STONE INCLUDED) (BASE STONE INCLUDED) SYSTEM AREA (SF) SYSTEM PERIMETER (ft) MAX FLOWINVERT*DESCRIPTIONITEM ON LAYOUTPART TYPE 0.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGSAMANIFOLD 0.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGSBMANIFOLD 1.5 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)CCONCRETE STRUCTURE W/WEIR 1.5 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)DCONCRETE STRUCTURE W/WEIR *INVERT ABOVE BASE OF CHAMBER 94.96'16.58'85.87'14.58'B A D C CONCEPTUAL ELEVATIONS MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67 MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67 TOP OF STONE:2.00 TOP OF SC-160LP CHAMBER:1.50 8" ISOLATOR ROW PLUS INVERT:0.58 8" ISOLATOR ROW PLUS INVERT:0.58 12" x 8" BOTTOM MANIFOLD INVERT (8" PIPE):0.58 12" x 8" BOTTOM MANIFOLD INVERT (8" PIPE):0.58 BOTTOM OF SC-160LP CHAMBER:0.50 12" x 8" BOTTOM MANIFOLD INVERT (12" PIPE):0.40 12" x 8" BOTTOM MANIFOLD INVERT (12" PIPE):0.40 BOTTOM OF STONE:0.00 PROPOSED LAYOUT 168 STORMTECH SC-160LP CHAMBERS 24 STORMTECH SC-160LP END CAPS STONE ABOVE (in) STONE BELOW (in) 40 STONE VOID 3044 INSTALLED SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED) (COVER STONE INCLUDED) (BASE STONE INCLUDED) 2942 SYSTEM AREA (SF) 301.7 SYSTEM PERIMETER (ft) MAX FLOWINVERT*DESCRIPTIONITEM ON LAYOUTPART TYPE -1.17" 0.96" 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (12" PIPE) 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (8" PIPE)AMANIFOLD -1.17" 0.96" 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (12" PIPE) 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (8" PIPE)BMANIFOLD 3.0 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)CCONCRETE STRUCTURE W/WEIR 3.0 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)DCONCRETE STRUCTURE W/WEIR ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 12.50' OF ADSPLUS625 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS 123.87'27.00'114.33'25.00'NOTES •THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. •NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE. *INVERT ABOVE BASE OF CHAMBER AB D C STORMTECH SC-160 LP SYSTEM 34SCALE: NTS ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 12.50' OF ADSPLUS625 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS NOTES •THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. •NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE. 70.06'24.92'64.52'22.92'A C B CONCEPTUAL ELEVATIONS MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67 MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67 TOP OF STONE:2.00 TOP OF SC-160LP CHAMBER:1.50 8" x 8" BOTTOM MANIFOLD INVERT:0.58 8" ISOLATOR ROW PLUS INVERT:0.58 8" ISOLATOR ROW PLUS INVERT:0.58 BOTTOM OF SC-160LP CHAMBER:0.50 BOTTOM OF STONE:0.00 PROPOSED LAYOUT 95 STORMTECH SC-160LP CHAMBERS 26 STORMTECH SC-160LP END CAPS 6 STONE ABOVE (in) 6 STONE BELOW (in) 40 STONE VOID 1761 INSTALLED SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED) (COVER STONE INCLUDED) (BASE STONE INCLUDED) 1713 SYSTEM AREA (SF) 190.0 SYSTEM PERIMETER (ft) MAX FLOWINVERT*DESCRIPTIONITEM ON LAYOUTPART TYPE 0.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGSAMANIFOLD (DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTURE W/WEIR 2.2 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)CCONCRETE STRUCTURE W/WEIR *INVERT ABOVE BASE OF CHAMBER STORMTECH SC-160 LP SYSTEM 2-11SCALE: NTS 40-YARD CONSTRUCTION DUMPSTER DETAILS5SCALE: NTS 82 14 6 6 40 1544 1508 223.1 CONCEPTUAL ELEVATIONS MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67 MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67 TOP OF STONE:2.00 TOP OF SC-160LP CHAMBER:1.50 8" ISOLATOR ROW PLUS INVERT:0.58 12" x 8" BOTTOM MANIFOLD INVERT (8" PIPE):0.58 BOTTOM OF SC-160LP CHAMBER:0.50 12" x 8" BOTTOM MANIFOLD INVERT (12" PIPE):0.40 BOTTOM OF STONE:0.00 PROPOSED LAYOUT 28 STORMTECH SC-160LP CHAMBERS 8 STORMTECH SC-160LP END CAPS 6 STONE ABOVE (in) 6 STONE BELOW (in) 40 STONE VOID 579 INSTALLED SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED) (COVER STONE INCLUDED) (BASE STONE INCLUDED) 579 SYSTEM AREA (SF) 132.8 SYSTEM PERIMETER (ft) MAX FLOWINVERT*DESCRIPTIONITEM ON LAYOUTPART TYPE -1.17" 0.96" 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (12" PIPE) 12" x 8" REDUCING CONCENTRIC MOLDED FITTINGS (8" PIPE)AMANIFOLD 1.5 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTURE W/WEIR ISOLATOR ROW PLUS (SEE DETAIL) PLACE MINIMUM 12.50' OF ADSPLUS625 WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS BED LIMITS 56.05'10.33'50.28'8.33'NOTES •THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. •NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE. *INVERT ABOVE BASE OF CHAMBER B A STORMTECH SC-160 LP SYSTEM 2-33SCALE: NTS