Loading...
HomeMy WebLinkAbout008-C4.0-UTILITY PLAN -WEST8''W 8''W 8''W8''W8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W6''W8''SS8''SSXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXW VW VW V HYDGASGASUGPUGPUGPUGPUGPUGPUGPUGPELECELECELECELECELECELECELECELECELECELECGASGASGASGASGASGASGASGASGASGASELECELECELECELEC ELEC ELEC STSTSTSTSTST STSTSTCO CO ST ST DS DSDS DS DS DS DS DS DS DS DS DS DS D S ST ST ST ST ST STSTST ST ST ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC ELEC 8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''WW V W VW V SSHYDHYD HY DW VW VW V SS ST ST ST ST ST STSTST ST STS T ST STS T STSTSTSTSTSTSTSTSTSTST8''SS 8''SS W V FW V FW VW V8''SS ELEC ELEC ELEC ELECINSTALL 8" DIA. SDR-35 DEEP SANITARY SEWER SERVICES TO PROPOSED BUILDINGS. SERVICES TO CONNECT TO 8" MAIN AT MANHOLE. REFER TO INFRASTRUCTURE PLANS FOR SERVICE DETAILS. STORMWATER INLET PER COB STD DWG NO. 02720-1A (TYP.) INSTALL 6" DIP FIRE SERVICE PER FIRE LINE PLAN INSTALL 4" DIP WATER SERVICE PER WATER SERVICE PLAN 3-PHASE TRANSFORMER WITH 7'X7' CONCRETE PAD SC160-LP UNDERGROUND RETENTION CHAMBER SEWER CLEANOUT IN CONCRETE LANDING (TYP.) SC160-LP UNDERGROUND RETENTION CHAMBER SC160-LP UNDERGROUND RETENTION CHAMBER SC160-LP UNDERGROUND RETENTION CHAMBER INSTALL 6" DIP FIRE SERVICE PER FIRE SERVICE PLAN 3-PHASE TRANSFORMER WITH 7'X7' CONCRETE PAD PROPOSED 8" WATER MAIN REFER TO APPROVED INFRASTRUCTURE PLANS PROPOSED 8" WATER MAIN REFER TO APPROVED INFRASTRUCTURE PLANS PROPOSED 8" SANITARY SEWER MAIN REFER TO APPROVED INFRASTRUCTURE PLANS SC160-LP UNDERGROUND RETENTION CHAMBER SC160-LP UNDERGROUND RETENTION CHAMBEREDGERTON BLVD23.5' x 12.5' ALCOVE FOR ELECTRICAL METERS REFER TO ARCH PLANS FIRE AND WATER RISER ROOM REFER TO APPROVED FIRE SERVICE PLAN & WATER SERVICE PLAN FOR DETAILS 29.5' 11.1' VALVES ON RIGHT-OF-WAY LINE (TYP.) 45° INV @ BUILDING:5006.77 INV @ BUILDING:5007.37 BLDG B F.F.E.:5013.40 BLDG A F.F.E.: 5012.80 10' UTILITY EASEMENT (TYP.) PATH FROM HYDRANT TO RISER ROOM (~85') 10' SETBACK EXTEND UNDERGROUND ELECTRIC FROM STUB TO NORTH 3 PHASE ELECTRIC ELECTRIC SERVICE FROM TRANSFORMER TO BUILDING. INSTALL 12" UTILITY CULVERT ACROSS RIGHT-OF-WAY FOR SERVICE. REFER TO INFRASTRUCTURE PLANS (3) 12" DIA UTILITY CULVERTS TO BE INSTALLED ACROSS RIGHT-OF-WAY WITH INFRASTRUCTURE IMPROVEMENTS 16' x 5' PAD FOR ELECTRICAL EQUIPMENT 16' x 5' PAD FOR ELECTRICAL EQUIPMENT 13.5' x 11' ALCOVE FOR ELECTRICAL METERS REFER TO ARCH PLANS FIRE AND WATER RISER ROOM REFER TO FIRE SERVICE PLAN & WATER SERVICE PLAN FOR DETAILS 29.5' 8.0' INSTALL 4" DIP WATER SERVICE PER WATER SERVICE PLAN VALVES ON RIGHT-OF-WAY LINE (TYP.) PATH FROM HYDRANT TO RISER ROOM (~94')10' SETBACK ELECTRIC SERVICE FROM TRANSFORMER TO BUILDING. PRO. HYDRANT (TYP.) MEAH LANE 10' UTILITY EASEMENT (TYP.) 749-01Alpine Job #: THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. 2025 ENCOMPASS DESIGN INC.C AN AFFORDABLE HOUSING DEVELOPMENT:ROCKY MOUNTAIN FLATSBOZEMAN, MONTANA1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 24.115edinc Job #: SITE PLAN REVIEW: 05/29/2025 REV. 02: SP RESUBMITTAL #2 C4.0 UTILITY PLAN - WEST 20'0 40' SCALE 1" = 20' N REV 2 REV 2