HomeMy WebLinkAboutSDP-16 - IRRIGATION DETAILS - STREET LEVELSITE DEVELOPMENT PLAN - THE NORTHERN - 2025-PROJMSTR-0000XXX - 2025-SDP-0000XXXSITE DEVELOPMENT PLANREMAINDER PORTION LOT 20, LOTS 19-16, & WEST 9' OF LOT 15 OF TRACY'S SECOND ADD.CITY OF BOZEMAN, GALLATIN COUNTY MONTANALOCATED AT 621 W MENDENHALL STTHE NORTHERN2'' TYPE ''L'' RIGID COPPER TUBINGSECURE BACKFLOW PREVENTER ASSEMBLYFASTEN TUBING TO FINISH FLOOR @ 18'' 0.C.AND COPPER TUBING TO WALL VIA UNI-STRUT CHANNEL AND COPPER FASTENERS AT 6 FT. O.C.VENT BACKFLOW PREVENTER DRAIN INTO POINT OF CONNECTIONFINISH FLOORFLOOR DRAINFEBCO 860U REDUCED PRESSURE BACKFLOW PRESSURE REDUCING VALVE (AS REQUIRED, RE:PLAN)PREVENTER WITH INTEGRAL UNIONSFLOWFEBCO 601 AIR GAP DRAINCxM ADAPTER - LINE DIA. (FOUR REQ'D.)12'' MIN. CxCxF TEEFLOW SENSOR (TO OPERATE AS SUBMETERFOR IRRIGATION USAGE)3/4'' I.P. MALE BRASS BOILER DRAINW/ WHEEL HANDLEBALL VALVE FOR SHUT-OFFTYPE K HARD COPPER TO PENETRATION LOCATIONSWIRE CONDUIT FROM CONTROLLERLINE SIZE MASTER VALVETYPE ''K'' RIGID COPPER - CONNECT TO BUILDINGCOLD WATER SERVICE LINE DOWNSTREAM OFWATER METER, UPSTREAM OF ANY PRESSUREREDUCING VALVES OR OTHER BUILDING SERVICEEQUIPMENT4-6" BODIES: 18"12" BODIES: 24"CONTROL WIRE BUNDLE OR TWOWIRE COMMUNICATION CABLE (PERSPECIFICATIONS)24"SPRAY HEAD LATERALPIPING OR DRIP LINEHEADER.FINISHGRADEROTOR LATERALPIPINGBACKFILL MATERIAL (TYP.)4-6" BODIES: 14"12" BODIES: 18"MAINLINENOTE: REFER TO TECHNICALSPECIFICATIONS FOR MINIMUMTRENCH WIDTHS.324" MAINLINETRENCHBAROUGH GRADECNOTE:·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ONPLAN.·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLESLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DONOT STACK SLEEVES VERTICALLY.·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A"V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING.·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, PONDLINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVILWORK AT APPROXIMATE LOCATIONS SHOWN.·AN INDIVIDUAL SLEEVE SHALL CONTAIN NO MORE THAN ONE PIPE OR WIREBUNDLE.PAVED SURFACECURB AND GUTTER(IF APPLICABLE)2" PVC PIPE SLEEVE MARKER -INSTALL AT BOTH ENDS OF EACHSLEEVE LOCATION AND EXTEND ATLEAST 3' ABOVE GRADE. SPRAYEXPOSED PORTION OF MARKER WITHGREEN FLUORESCENT PAINT. REMOVEAT FINAL INSTALL.SEAL ENDS OF SLEEVE WITHCLOTH DUCT TAPE (TYPICAL)PVC OR HDPE SLEEVING (TYPICAL)24" MIN.12" MIN.36" MIN.IRRIGATION SLEEVING4TYPICALFINISH GRADEAPPLY TEFLON TAPE TO ALL MALE THREADEDPVC FITTINGS AND ALL NIPPLES34" CRUSHED GRAVEL SUMP 1 CU. FT.2" VALVE MARKER10" ROUND VALVE BOX - BRAND THELETTER "D' IN LID. REFER TOTECHNICAL SPECIFICATIONS.2" CL 200 PVC ACCESS SLEEVE -LENGTH AS REQUIRED1" FxF BRASS 90 ELL (2) 1"xCLBRASS NIPPLE (2)1"x6" BRASS NIPPLE1" BRASS 1/4 TURN CURB STOP1" MxF SCH. 40 PVC 90 ELLSOIL BLANKET COVERING SUMP1"x4" PVC NIPPLE SCH. 8034" CRUSHED GRAVEL SUMP. SEETECHNICAL SPECIFICATIONS FORSUMP SIZEPVC PRESSURE MAINLINE. REFERTO TRENCH DETAIL.MANUAL DRAIN VALVE5TYPICALFINISH GRADE2"3"10" ROUND VALVE BOX. BRAND "GV"ON LID OF VALVE BOX. REFER TOTECHNICAL SPECIFICATIONS.GATE VALVE W/ CROSS HANDLE ANDSOLID WEDGE DISC.34" CRUSHED GRAVEL SUMP - FILLBOX TO WITHIN 2" OF TOP OF 6"PVC ACCESS SLEEVE∅6" CLASS 200 PVC SLEEVE BOTTOM TOBE NOTCHED AND CONTACT TOP OFPRESSURE MAINLINEPVC PRESSURE MAINLINESCH. 40 PVC MALE ADAPTER (2) - SIZETO EQUAL GATE VALVE DIAMETERUNDISTURBED SOIL6GATE VALVE2.5" & SMALLER - X-HANDLEDIRECTORYIRRIGATION SCHEDULE & NOTES -STREET LEVEL SDP-15IRRIGATION PLAN - STREET LEVEL SDP-16IRRIGATION DETAILS - STREET LEVEL SDP-17 - SDP-18IRRIGATION PLAN & SCHEDULE- ROOFTOP SDP-19IRRIGATION DETAILS &NOTES - ROOFTOP SDP-20 - SDP-21FINISH GRADEAPPLY TEFLON TAPE TO ALL THREADED NIPPLES3"2"10" ROUND VALVE BOX BRAND"QC" INTO VALVE BOX LID.REFER TO TECHNICALSPECIFICATIONS.34" CRUSHED GRAVEL SUMP -FILL BOX TO WITHIN 2" OFBOTTOM OF QCV LID1" BRASS NIPPLE LENGTH AS REQUIREDLINE SIZE BRASS COUPLING12"x12" REBAR STABILIZING STAKETYPICAL TWO SIDES PER QUICKCOUPLING VALVE LOCATIONLASCO #G 13S-212 UNITIZED SWINGJOINT W/ BRASS INSERT STABILIZERELBOW. PROVIDE WITH 1" MIPT INLETPRESSURE MAINLINEx1" PVC SERVICE TEE -SOLVENT WELD OR GASKETED FITTING REFERTO SPECIFICAIONSQUICK COUPLING VALVEQUICK COUPLING VALVE7LASCOSWING - TYPICALNOTE:INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVEBOX EXTENSIONS WILL BE ACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROLVALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISHGRADE. VALVE BOX SHALL NOT REST ON DRIP TUBING.3" MIN.PVC SCH. 40 TEE OR ELL3" MIN DEPTH OF 34" WASHED GRAVELPVC MAINLINEPVC SCH. 80 NIPPLE, CLOSEPVC SCH. 80 UNION FORSERVICING ASSEMBLYDRIP VALVE ASSEMBLY WITH BASKETFILTER (SEE SCHEDULE)FINISH GRADEJUMBO VALVE BOX - BRAND BOX LID W/CONTROLLER AND STATION NUMBER - REFERTO TECHNICAL SPECIFICATIONS.WATER PROOF SPLICE24" COILED WIREPVC SCH. 80 NIPPLEPVC SCH. 40 ELLVALVE SIZE MIPTxINS. PVC ADAPTERSTAINLESS STEEL WORM GEAR ORPINCH CLAMPVALVE SIZE POLY PIPING -SWEEP TO SPECIFIED DEPTHINSERT TEE WITH CLAMPS12" POP-UP SPRAY HEAD WITH CHECK VALVE,CLOSED NOZZLE, PURPLE CAP & SWING PIPE(ZONE OPERATIONAL INDICATOR)DRIP VALVE824V - LARGE WITH POLY LATERAL1PVC CONDUIT W/ SWEEP ELL(TYP. UNDEGROUND LOCATIONS)FINISH FLOOREMT MALE ADAPTER & PVC FEMALE ADAPTERSECURE CONDUIT TO WALL 18" O.C.EMT CONDUIT - SIZE TO ACCOMMODATECONTROL WIRE QUANTITYEMT MALE APAPTER W/ WASHER & LOCK RINGELECTRIC CONTROLLERSECURE CONTROLLER TOWALL WITH ANCHOR BOLTS18''54" MIN.60" MAX.FINISH GRADENOTE: COORDINATE INSTALLATION OF CONDUIT WITHCONSTRUCTION OF FOUNDATION AND FLOOR.ELECTRIC CONTROLLER2INTERIOR WALL MOUNT - FLOOR PENETRATINGSDP-1717 OF 2813949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401o: 303.980.5327 www.hydrosystemskdi.comIrrigation Consulting & Water ManagementCALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.RKnow what's below. Call before you dig.COP x MIP ADAPTER & PVC SLIPMIP ADAPTER (2) INTO FLOW SENSORIRRIGATION DETAILS - STREET LEVEL16 OF 2716