HomeMy WebLinkAboutSDP-06 - CONSTRUCTION MANAGEMEN PLANT
4"
4"N00°04'35"E 120.04'W. MENDENHALL STREET
(50' ROW)
ALLEY
(20' ROW)N. 7TH AVENUES00°04'52"E 140.13'S89°39'46"W 126.32'
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
L = 30.34'
R = 20.00'
Δ = 86°55'29"
PROPERTY
LINE
20.0'10.0'10.0'6.1'30.0'
106.7'20.0'30.0'11.5'SPOILS LOCATION AREA
(TO BE REMOVED OR RELOCATED
AFTER DEMOLITION PHASE TO
FACILITATE CONSTRUCTION)
STABILIZED CONSTRUCTON
ENTRANCE
(TO BE REMOVED AFTER
DEMOLITION PHASE)
STABILIZED CONSTRUCTON
ENTRANCE
(TO BE REMOVED AFTER
DEMOLITION PHASE)
TRASH ENCLOSURE -
SEE DETAIL THIS SHEET
(TO BE RELOCATED AS NEEDED
TO FACILITATE CONSTRUCTION)
NORTHBOUND LANE CLOSURES ON N. 7TH AVENUE
WILL BE KEPT TO A MINIMUM & LIMITED
TO SHORT TERM DURATIONS AS NEEDED
FOR MISC. CONSTRUCTION TASKS -
LONG TERM LANE CLOSURES ARE NOT ANTICIPATED
LANE CLOSURES ON W. MENDENHALL STREET
WILL BE LIMITED TO THE NORTHERN TRAFFIC
LANE & ARE EXPECTED TO LAST 12-14 MONTHS
CONSTRUCTION OF THE SANITARY SEWER
MAIN WILL REQUIRE COMPLETE
CLOSURE FOR THE DURATION OF CONSTRUCTION
ALLEY TO REMAIN OPEN AT ALL TIMES
DURING BUILDING CONSTRUCTION
COMPLETE ALLEY CLOSURE WILL BE
REQUIRED DURING ALLEY RECONSTRUCTION
SIDEWALKS ADJACENT TO PROPERTY
WILL BE CLOSED DURING CONSTRUCTION
TO PROVIDE PEDESTRIAN SAFETY
& CONSTRUCTION STAGING
SIDEWALKS ADJACENT TO PROPERTY
WILL BE CLOSED DURING CONSTRUCTION
TO PROVIDE PEDESTRIAN SAFETY
& CONSTRUCTION STAGING
TOWER CRANE TO BE
LOCATED IN STAIR CORE
CONSTRUCTION
MATERIAL STAGING
AREA N89°38'30"E 144.94'
ONE-WAY TRAFFIC HEADING WEST
63.9'11.5'CONSTRUCTION
MATERIAL STAGING
& TRAILER AREA 11.5'42.8'11.5'23.1'NOTES:
1.ALL CONSTRUCTION TRAFFIC SHALL FOLLOW
ROUTES AND UTILIZE CONSTRUCTION ENTRANCE
LOCATIONS DEPICTED ON THE CONSTRUCTION
ROUTE MAP (SHEET EX-1).
2.CONTRACTOR TO MODIFY LOCATIONS SHOWN ON
THIS PLAN AS NECESSARY TO ACCOMMODATE
EACH PHASE OF CONSTRUCTION.
3.ALL SPOILS GENERATED FROM DEMOLITION
ACTIVITIES ARE TO BE STORED IN THE
DESIGNATED LOCATION OR AN ALTERNATE
LOCATION DETERMINED BY THE CONTRACTOR
AND REMOVED IN A TIMELY MANNER. SPOILS
GENERATED DURING EARTHWORK PROCESSES
SHALL BE STORED IN THE DESIGNATED LOCATION
AND MAY REMAIN ONSITE FOR UP TO 6 MONTHS
IF RESERVED FOR BACKFILL AND FINAL GRADING
PURPOSES.
4.NOTIFY ENGINEER IF FIELD CONDITIONS DIFFER
FROM WHAT IS SHOWN ON THESE PLANS.
40-YARD ROLL OFF DUMPSTER DETAIL
NTS
SITE DEVELOPMENT PLAN
THE NORTHERN
REMAINDER PORTION LOT 20, LOTS 19-16, & WEST 9' OF LOT 15 OF TRACY'S SECOND ADD.
CITY OF BOZEMAN, GALLATIN COUNTY MONTANA
LOCATED AT 621 W MENDENHALL ST
101 E. Loucks Street, #300
Sheridan, WY 82801
PHONE: 970-227-0714
SDP-06
CONSTRUCTION
MANAGEMENT
PLAN
6 OF 28
0'10'20'
SCALE: 1" = 10'
N
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2 BUSINESS DAYS IN ADVANCE
CENTER OF MONTANA
CALL UTILITY NOTIFICATION
1-800-424-5555
MEMBER UTILITIES.
BENCHMARK:
ELEVATION DATUM IS NAVD 88
BASIS OF BEARING:
BOBCAT LDP COORDINATE SYSTEM
POINT NORTHING EASTING ELEVATION DESCRIPTION
30 120391.19 380214.59 4821.11 MDT Cu Plug LS59853
96 120340.70 380215.51 4822.33 CH MAG DISK
97 120549.24 380217.82 4819.94 MAG NAIL
98 120536.01 380339.37 4820.54 MAG NAIL
99 120440.54 380329.09 4821.26 MAG NAIL
CONTROL POINT TABLE:
PROPOSED SANITARY SEWER LINE
PROPOSED WATER SERVICE
PROPOSED WATER VALVE
EXISTING FIRE HYDRANT
EXISTING WATER VALVE
EXISTING POWER POLE
EXISTING GUY WIRE
EXISTING WATER METER
EXISTING LIGHT POLE
EXISTING FIBER OPTIC LINE
EXISTING GAS LINE
EXISTING WATER LINE
EXISTING OVERHEAD POWER LINE
EXISTING SANITARY SEWER LINE
EXISTING UNDERGROUND POWER LINE
EXISTING UNDERGROUND TELEPHONE LINE
PROPOSED CURB BOX
PROPOSED CORP STOP
PROPOSED BACKFLOW PREVENTER
EX RIGHT-OF-WAY/ PROPERTY BOUNDARY
LEGEND:
CONTROL POINT
PROPOSED SANITARY SEWER MANHOLE
PROPOSED FIRE HYDRANT
PROPOSED SEWER CLEANOUT
PROPOSED ELECTRIC SERVICE
PROPOSED TELEPHONE SERVICE
PROPOSED GAS SERVICE
PROPOSED FIRE DEPARTMENT CONNECTION
11/7/25
6 OF 27