Loading...
HomeMy WebLinkAboutSDP-05 - CIVIL INFRASTRUCTURE PLANT 4" 4" LAMME ST PROPERTY LINE FIRE HYDRANT TO BE RELOCATED PROPERTY LINE PROPERTY LINE PROPERTY LINE L = 30.34' R = 20.00' Δ = 86°55'29" PROPERTY LINE PROPOSED 8" SDR35 SEWER SERVICE @ 1.0% PROPOSED CONNECTION TO 8" SANITARY SEWER MAIN AT PROPOSED MANHOLE PROPOSED BUILDING 621 W. MENDENHALL STREET BOZEMAN, MT 59715N00°04'35"E120.04'W. MENDENHALL STREET (50' ROW) ALLEY (20' ROW)S00°04'52"E140.13'N89°38'30"E 144.94' S89°39'46"W 126.32' PROPOSED FIRE HYDRANT LOCATION ON EXISTING LATERAL W/ 6" GATE VALVE PROPOSED 8" SDR35 SANITARY SEWER MAIN EXISTING SEWER SERVICE TO BE ABANDONED AND/OR REMOVED EXISTING SEWER SERVICE TO BE ABANDONED AND/OR REMOVED EXISTING SEWER SERVICE TO BE ABANDONED AND/OR REMOVED PROPOSED SANITARY SEWER MANHOLE N. 7TH AVENUEPROPOSED SANITARY SEWER MANHOLE CONNECT NEW SANITARY SEWER MAIN TO EXISTING SANITARY SEWER MANHOLE EXISTING SANITARY SEWER MANHOLE TO BE REPLACED EXISTING 6" SANITARY SEWER MAIN TO BE REPLACED EXISTING 6" SANITARY SEWER MAIN TO BE REPLACED EXISTING SANITARY SEWER SERVICE TO BE RECONNECTED TO PROPOSED SEWER MAIN (TYP.)N. 5TH AVENUEW. LAMME STREET (50' ROW) PROPOSED PEDESTRIAN LIGHT PER COB STANDARD DETAILS FUTURE PEDESTRIAN LIGHT PER COB STANDARD DETAILS TO BE INSTALLED BY OTHERS FUTURE PEDESTRIAN LIGHT PER COB STANDARD DETAILS TO BE INSTALLED BY OTHERS FUTURE PEDESTRIAN LIGHT PER COB STANDARD DETAILS TO BE INSTALLED BY OTHERS FUTURE PEDESTRIAN LIGHT PER COB STANDARD DETAILS TO BE INSTALLED BY OTHERS PROPOSED BIKE RACKS RE: LANDSCAPE PLANS FOR DETAILS RELOCATED BUS STOP SIGN PROPOSED BIKE RACKS RE: LANDSCAPE PLANS FOR DETAILS SITE DEVELOPMENT PLAN THE NORTHERN REMAINDER PORTION LOT 20, LOTS 19-16, & WEST 9' OF LOT 15 OF TRACY'S SECOND ADD. CITY OF BOZEMAN, GALLATIN COUNTY MONTANA LOCATED AT 621 W MENDENHALL ST 101 E. Loucks Street, #300 Sheridan, WY 82801 PHONE: 970-227-0714 NOTES: 1.PLEASE REFER TO THE GEOTECHNICAL REPORT FOR EXCAVATION, GRADING, COMPACTION, AND PAVING RECOMMENDATIONS AND REQUIREMENTS FOR THE PROJECT SITE. 2.BUILDING INFORMATION - DIMENSIONS, LOCATION, UTILITY CONNECTIONS AND SIZES, ETC. WERE PROVIDED BY OTHERS. REFER TO THE APPROPRIATE ARCHITECTURAL AND MEP DRAWINGS FOR DETAILS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE MOST CURRENT APPROVED ARCHITECTURAL/MEP DRAWINGS AND COORDINATE BUILDING LOCATIONS AND UTILITY CONNECTIONS WITH THESE CIVIL DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 3.NOTIFY ENGINEER IF FIELD CONDITIONS DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 4.THE CONTRACTOR SHALL NOTIFY THE CITY OF BOZEMAN TO INITIATE THE PROCESS OF UTILITY WORK. 5.CONTRACTOR RESPONSIBLE FOR LOCATING AND VERIFYING DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 6.CONTRACTOR SHALL ENSURE THAT MINIMUM CLEARANCE AT ALL UTILITY CROSSINGS IS PROVIDED PER CITY OF BOZEMAN STANDARDS. 7.ALL UTILITIES AND APPURTENANCES SHALL BE INSTALLED PER MANUFACTURER, MDT, OR CITY OF BOZEMAN STANDARDS, DETAILS, AND SPECIFICATIONS. PROPOSED SANITARY SEWER LINE PROPOSED WATER SERVICE PROPOSED WATER VALVE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING POWER POLE EXISTING GUY WIRE EXISTING WATER METER EXISTING LIGHT POLE EXISTING FIBER OPTIC LINE EXISTING GAS LINE EXISTING WATER LINE EXISTING OVERHEAD POWER LINE EXISTING SANITARY SEWER LINE EXISTING UNDERGROUND POWER LINE EXISTING UNDERGROUND TELEPHONE LINE PROPOSED CURB BOX PROPOSED CORP STOP PROPOSED BACKFLOW PREVENTER EX RIGHT-OF-WAY/ PROPERTY BOUNDARY LEGEND: CONTROL POINT 0'30'60' SCALE: 1" = 30' N FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE CENTER OF MONTANA CALL UTILITY NOTIFICATION 1-800-424-5555 MEMBER UTILITIES. BENCHMARK: ELEVATION DATUM IS NAVD 88 BASIS OF BEARING: BOBCAT LDP COORDINATE SYSTEM POINT NORTHING EASTING ELEVATION DESCRIPTION 30 120391.19 380214.59 4821.11 MDT Cu Plug LS59853 96 120340.70 380215.51 4822.33 CH MAG DISK 97 120549.24 380217.82 4819.94 MAG NAIL 98 120536.01 380339.37 4820.54 MAG NAIL 99 120440.54 380329.09 4821.26 MAG NAIL CONTROL POINT TABLE: SDP-05 CIVIL INFRASTRUCTURE PLAN 5 OF 28 PROPOSED SANITARY SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED SEWER CLEANOUT PROPOSED ELECTRIC SERVICE PROPOSED TELEPHONE SERVICE PROPOSED GAS SERVICE PROPOSED FIRE DEPARTMENT CONNECTION 11/7/25 5 OF 27