Loading...
HomeMy WebLinkAbout03-L5-IRRIGATION PLAN2''W2''WGASGASUGEUGEWWWW W W W W COMMCOMMcccccccccccccccccccccccccccccccccPPWWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXPPPPPPPPPPPPPPPPPPPPPPPPPPPPH-ZONE 2C2,193 SFH-ZONE 4C3638 SFH-ZONE 1CF2424 SFH-ZONE 2CF2036 SFH-ZONE 3CF1,418 SFH-ZONE 4CF1,649 SFH-ZONE 5CF2,186 SFH-ZONE 6CF1246 SFH-ZONE 7CF1975 SFSEEDED AREA= 3,429 SFSEEDED AREA= 857 SF incommon siteSEEDED AREA=5,297 SF incommon siteHOTEL(180 ROOMS)EJBWWWWWWWWWWW W W W XXXXXXXXXSD SD SD Δ=2°27'41"R=3169.04L=136.14 H-ZONE1C 2,398 SF. THISONLY SERVES AREAS NOTIN THE ROW.H-ZONE 1C: This zone is now thepbed areas that are in the 19th stROW. Most are in Ph1 south of theaccess drive. This small area is in Ph2H-ZONE 6C ONLY SERVEStrees NOT IN THE ROW.SEEDED AREA= 2,879 SFONLY ON-SITE.H-ZONE1RW 1179 SF. THISONLY SERVES AREAS NOTIN THE ROW.SEEDED AREA= 722 SF INROW.SEEDED AREA= 817 SF INROW.N. 19TH A V E .PERMIT11/11/2025Information contained on this drawing and in all digital filesproduced for above named project may not be reproduced inany manner without express written or verbal consent fromauthorized project representatives.CONSULTANT PROJECT #PRINTED FORDATESHEETSHEET NUMBERLP/JV/TRDRAWN BYNO.DATEDESCRIPTIONBOZEMAN, MTREVISION SCHEDULEA046651234BCDEABCDE1234FSR#CHICK-FIL-A 3204 N. 19TH STREET BOZEMAN, MT 59718 Chick-fil-A5200 Buffington RoadAtlanta, Georgia 30349-299822282BUILDING TYPE / SIZE:RELEASE:CHICK-FIL-A BOZEMANDial 811Call before you dig.Know what's below.Or 1-800-551-8344SIGNED 11/11/2025REVISED PER COMMENTS104/03/25REVISED PER COMMENTS209/02/25REVISED PER COMMENTS311/11/25IRRIGATION PLANL5IRRIGATION PLANSCALE: 1"=20'MATCHLINE - SEE RIGHT MATCHLINE - SEE LEFTACCESS DRIVE - PH 1TRASHENCLOSUREPH 1 ACCESS DRIVEMATCHLINE AND PHASE LINE - SEE SHEET L6 IN THISPLAN SET AND PHASE 2 UNDER SEPARATE SUBMITTAL.MATCHLINE - SEE PHASE 2 UNDER SEPARATE SUBMITTAL PHASE 2HOTELNOT A PARTSEE SEPARATESUBMITTALPROPERTYLINEPROPERTYLINEPROPERTYLINEPROPERTYLINE ANDRIGHT-OF-WAY LINEPHASELINEPROPOSEDCHICK-FIL-ARESTAURANTSTORAGEPH 2 SIDEWALKPLAZA10 FT. WIDE SHARED USE PATHINSTALL IRRIGATION MAINLINE ADJACENT TO PHASE 2PROPERTY / R.O.W. LINE AND CONNECT TO EXISTINGWELL WATER SUPPLY AS PART OF PHASE 1. SEESHEET L6 FOR CONTINUATION.COORDINATE SLEEVEINSTALLATION WITHINSTALLATION OFPAVEMENTS, CURBS ANDOTHER HARDSCAPE, TYP.MOUNT RAIN SENSORON WEATHEREXPOSED PORTIONOF TRASHENCLOSURE WALLMOUNT CONTROLLER ON EXTERIORWALL. INPUT: 117VAC +/-10%, 60 HZ.OUTPUT: 26.5 VAC, 1.5 A. INSTALL 1"DIAMETER PVC CONDUIT FOR 24VELECTRICAL WIRING FROM THECONTROLLER TO LANDSCAPE AREA.PAINT CONDUIT TO MATCH COLOR OFTRASH ENCLOSURE WALLNOTE:THE IRRIGATION POINT OF CONNECTION IS ATAN EXISTING IRRIGATION WELL ON THE HOTELSITE (PHASE 2). SEE SHEET L6. COORDINATEWITH OWNERS AND PHASE 2 HOTELCONTRACTOR. VERIFY LOCATION OF THECORRECT WELL PRIOR TO BEGINNING WORK.DIVISION LINEBETWEENCOMMON OPENSPACE ANDCHICK-FIL-A SITESMOUNT RAIN SENSOR FOR COMMONOPEN SPACE ON WEATHER EXPOSEDPORTION OF EXTERIOR OF STEELPEDESTAL ENCLOSURE.MOUNT CONTROLLER FOR COMMON OPENSPACE ON IN STEEL PEDESTAL. INPUT: 117VAC+/-10%, 60 Hz. OUTPUT: 26.5 VAC, 1.5 A. INSTALL1" DIAMETER PVC CONDUIT FOR 24VELECTRICAL WIRING FROM THE CONTROLLERTO LANDSCAPE AREATHIS CONTROLLER WILL SERVE THECOMMON OPEN SPACE AS WELL AS THESTREET R.O.W. IN BOTH PHASES 1 AND 2.IRRIGATION ZONES 1RW AND2RW ARE TO BE INSTALLED ASPART OF PHASE 1.CONTRACTOR SHALL INSTALLIRRIGATION WIRING FROM THECOMMON OPEN SPACECONTROLLER TO SERVEIRRIGATION ZONE IN THE 19THAVE R.O.W.. BUNDLE WIRES INA TEMPORARY VALVE BOXNEXT TO THE GATE VALVE.PHASE LINEINSTALL SLEEVES ACROSS ACCESS DRIVE,FUTURE SIDEWALK AND SHARED USEPATH / WALKS AS PART OF PHASE 1, TYP.INSTALL GATE VALVES AS PART OF PH 1. STUBOUT MAINLINE TO EAST FOR PH 1.PH 2 SIDEWALK"C" INDICATES A VALVE FOR THECOMMON OPEN SPACE, TYP."C" INDICATES A VALVE FOR THECOMMON OPEN SPACE, TYP.NO IRRIGATIONIN NON-TURFGRASS AREAS,TYP.NO IRRIGATION INNON-TURF GRASSAREAS, TYP.THESE TWO AREAS TO RECEIVE DRIPIRRIGATION IN PHASE 2 - PROVIDE STUB-OUTSAS NECESSARY FOR PHASE 2. COORDINATEWITH PHASE 2 CONSTRUCTION. IRRIGATION INTHE ROW HAS SEPARATE HYDROZONES FROMON-SITEPH 2 WALKWAYSIDEWALK - SEE PH 2 10 FT. WIDE SHARED USE PATH10 FT. WIDE SHAREDUSE PATH - PH 1STUB-OUTAND CAPLATERALFOR PHASE 2PHASE 2LANDSCAPING -SEE SEPARATESUBMITTALHYDROZONELINE, TYP.PHASE 2 19TH AVE. R.O.W.NORTH OF ACCESS DRIVENOT A PARTSEE SEPARATE SUBMITTALHYDROZONE LINE, TYP.HYDROZONE LINE, TYP.EXPANSION OF DRIP IRRIGATION ON ZONE 1RW INTOTHIS AREA IN ROW NORTH OF ACCESS DRIVE IS INPHASE 2.SIGNSEE TO THE LEFT ON THISSHEET FOR CONTINUATIONOF THIS HYDROZONE.PH 1 CURB & GUTTERPH 2 CURB & GUTTER PH 1 CURB & GUTTER.HOTEL - SEEPHASE 2PRESSURE LOSS TO FURTHESTPOINT IN IRRIGATION SYSTEM:VALVE #5C, TREE BUBBLERBEGINNING STATIC WATER PRESSURE: 70 PSI(OUTGOING PSI SET TO 70 PSI)BACKFLOW PREVENTION DEVICE:MASTER VALVE AND FLOW SENSOR:-10% OF TOTAL: -7.0 =63.0 PSI750' 2" SCH 40 MAINLINE:-0.68 RUNNING AT 10.0 GPM, -0.09 PSI/100'IRRIGATION VALVE:-1.75100' 1" SCH 40 LATERAL:-0.8 RUNNING AT 5 GPM, -0.8 PSI/100'100' 34" SCH 40 LATERAL:-2.5 RUNNING AT 5 GPM, -2.5 PSI/100'FITTINGS LOSS (10% OF PIPE):-0.4ELEVATION GAIN OR LOSS:+0.0NET PSI LOSS:-6.13ESTIMATED PSI AT FURTHEST POINT: 56.87ABOVE THE MINIMUM OPERATIONAL PSIREQ'D FOR THE LISTED EQUIPMENTEXTEND ZONE 1RWLATERAL TO THE NORTHSIDE OF THE ACCESS DRIVETO SERVE THE PHASE 2DRIP ZONE IN ROW.AN EMERGENCY ONLY VEHICULAR ACCESS CONNECTION TO THEADJACENT PROPERTY TO THE SOUTH IS BEING PROVIDED SOLELY TOMEET CITY OF BOZEMAN REQUIREMENTS. THE VEHICULAR ACCESSCONNECTION IS PROVIDED FOR EMERGENCY VEHICLES ONLY AND APHYSICAL BARRIER SHALL BE INSTALLED AND MAINTAINED INDEFINITELYTO PREVENT NON-EMERGENCY VEHICLE ACCESS FROM UTILIZING THEACCESS CONNECTION. MODIFICATIONS TO THIS EMERGENCY ONLYVEHICULAR ACCESS OR TO THE PHYSICAL BARRIER PREVENTINGNON-EMERGENCY ACCESS REQUIRE THE EXPRESS WRITTEN UNANIMOUSAPPROVAL OF ALL UNIT OWNERS OF THE 9019 CONDOMINIUMS. THE CITYOF BOZEMAN HAS DETERMINED THE EMERGENCY ONLY VEHICULARACCESS CONNECTION CONDITIONS FULLY SATISFY AND ARE COMPLIANTWITH INTER-SITE CONNECTIVITY AND INTERNAL ROADWAY DESIGNREQUIREMENTS OF BOZEMAN MUNICIPAL CODE SECTIONS 38.520.060.CAND 38.520.060.D.