Loading...
HomeMy WebLinkAboutADMC040EN - GLAZING SPECkawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 1 ADMC040EN APRIL, 2024 FEATURES Features • Trifab® VersaGlaze® 451/451T is 4-1/2" (114.3) deep with a 2" (50.8) sightline • Front, Center, Back or Multi-Plane glass applications • Flush glazed from either the inside or outside • Screw Spline, Shear Block, Stick or Continuous Head and Sill fabrication • Screw Spline Pre-Glazed option • SSG / Weatherseal option • IsoLock® lanced and debridged thermal break option with Trifab® VersaGlaze® 451T • Infill options up to 1-1/8" (28.6) thickness • Permanodic® anodized finishes option • Painted finishes in standard and custom choices Optional Features • Acoustical rating per AAMA 1801 and ASTM E 1425 • Project specific U-factors (See Thermal Charts) • Integrates with Versoleil® SunShade Outrigger System and Horizontal Single Blade System • Profit$Maker® Plus die sets available Product Applications • Storefront, Ribbon Window, Punched Openings or Pre-Glazed • Single-span • Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be incorporated • Kawneer windows or GLASSvent® Windows for Storefront Framing are easily incorporated For specific product applications, consult your Kawneer representative. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System2 ADMC040EN APRIL, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 3 ADMC040EN APRIL, 2024 PICTORIAL VIEWS ........................................................................5-10 CENTER ......................................................................................11-27 CENTER (LARGE MISSLE IMPACT) ..........................................28-30 FRONT .......................................................................................31-45 BACK ...........................................................................................47-53 MULTI-PLANE .............................................................................55-61 AIR/VAPOR BARRIER TIE-IN OPTION ............................................62 CHARTS (WIND LOAD, DEADLOAD, END REACTION & THERMAL) ...63-117 INDEX Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System4 ADMC040EN APRIL, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 5 ADMC040EN APRIL, 2024 The split vertical in the Screw Spline system allows a frame to be installed from unitized assemblies. Screws are driven through the back of the verticals into splines extruded in the horizontal framing members.The Individual units are then snapped together to form a complete frame. The Shear Block system of fabrication allows a frame to be pre-assembled as a single unit. Horizontals are attached to the verticals with shear blocks. SCREW SPLINE ASSEMBLY SHEAR BLOCK ASSEMBLY The Stick system allows on-site construction. Head and sill receptors are fastened to the surround. Vertical mullions are then installed in these receptors and are held in place by snap-in inserts. Intermediate horizontal members are attached to the verticals with shear blocks. Flashing is not required. NOTE:If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 18) STICK ASSEMBLY MULLION SNAP-IN FILLER SPLINE SCREWS HEAD GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL SILLFLASHING MULLION SHEAR BLOCK SHEAR BLOCK HEAD GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL SILLFLASHING SHEAR BLOCK MULLION SHEAR BLOCK HEAD RECEPTOR GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL RECEPTOR HEAD INSERT SILL INSERT PICTORIAL VIEW (CENTER) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System6 ADMC040EN APRIL, 2024 The split vertical in the Screw Spline system allows a frame to be installed from unitized assemblies. Screws are driven through the back of the verticals into splines extruded in the horizontal framing members.The Individual units are then snapped together to form a complete frame. The Shear Block system of fabrication allows a frame to be pre-assembled as a single unit. Horizontals are attached to the verticals with shear blocks. The Stick system allows on-site construction. Head and sill receptors are fastened to the surround. Vertical mullions are then installed in these receptors and are held in place by snap-in inserts. Intermediate horizontal members are attached to the verticals with shear blocks. Flashing is not required. NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 40) SCREW SPLINEASSEMBLY SHEAR BLOCKASSEMBLY STICK ASSEMBLY MULLION SNAP-IN FILLER SPLINE SCREWS HEAD GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL SILLFLASHING SHEAR BLOCK SHEAR BLOCK HEAD GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL SILLFLASHINGSHEAR BLOCK MULLION SHEAR BLOCK HEAD RECEPTOR GLASS STOP INTERMEDIATEHORIZONTAL GLASS STOP SILL INSERT FLAT FILLER FLAT FILLER HEAD INSERT SILL RECEPTOR PICTORIAL VIEW (FRONT) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 7 ADMC040EN APRIL, 2024 STICKASSEMBLY(WEATHERSEAL) STICK ASSEMBLY (SSG) The Stick system allows on-site construction. Head and sill receptors are fastened to the surround. Vertical mullions are then installed in these receptors and are held in place by snap-in inserts. Intermediate horizontal members are attached to the verticals with shear blocks. Flashing is not required. NOTE:If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 40) SSGMULLION SHEAR BLOCK HEADRECEPTOR INTERMEDIATEHORIZONTAL GLASS STOP SILL INSERT WEATHERSEAL SHEAR BLOCK HEADRECEPTOR SSG MULLION INTERMEDIATEHORIZONTAL GLASS STOP SILL INSERT COVER HEAD INSERT SILLRECEPTOR HEAD INSERT COVER SILL RECEPTOR PICTORIAL VIEW (FRONT) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System8 ADMC040EN APRIL, 2024 CONTINUOUS HEAD AND SILL ASSEMBLY PUNCHED OPENING (WEATHERSEAL) The CONTINUOUS HEAD AND SILL punched opening fabrication allows a frame to be pre-assembled and installed as a single unit. Screws are driven through the back of the head and sill members into splines extruded in the vertical framing members. Intermediate horizontals are attached to the verticals with shear blocks. CONTINUOUS HEAD AND SILL ASSEMBLY PUNCHED OPENING (CAPTURED) CONTINUOUS HEAD AND SILL ASSEMBLY PUNCHED OPENING (SSG) MULLION SHEAR BLOCK HEAD INTERMEDIATEHORIZONTAL GLASS STOP SILL HEAD COPE GLASS STOP SSG MULLION SHEAR BLOCK HEAD INTERMEDIATEHORIZONTAL GLASS STOP SILL GLASS STOP SSG COVER SSG MULLION SHEAR BLOCK HEAD INTERMEDIATEHORIZONTAL GLASS STOP SILL GLASS STOP SSG COVER WEATHERSEAL PICTORIAL VIEW (FRONT) The Punched Opening fabrication allows a frameto be pre-punched and installed as a singleunit. screws are driven through the back of thehead and sill members into splines extruded inthe vertical framing members.Intermediate horizontals are attached to theverticals with shear blocks. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 9 ADMC040EN APRIL, 2024 The split vertical in the Screw Spline system allows a frame to be installed from unitized assemblies. Screws are driven through the back of the verticals into splines extruded in the horizontal framing members.The Individual units are then snapped together to form a complete frame. The Shear Block system of fabrication allows a frame to be pre-assembled as a single unit. Horizontals are attached to the verticals with shear blocks. SCREW SPLINE ASSEMBLY SHEAR BLOCK ASSEMBLY The Stick system allows on-site construction. Head and sill receptors are fastened to the surround. Vertical mullions are then installed in these receptors and are held in place by snap-in inserts. Intermediate horizontal members are attached to the verticals with shear blocks. Flashing is not required. NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 51) STICK ASSEMBLY SPLINE SCREWS HEAD INTERMEDIATEHORIZONTAL GLASS STOP SILL GLASS STOP FLAT FILLER SILLFLASHING FLAT FILLER MULLION SHEAR BLOCK HEAD INTERMEDIATEHORIZONTAL GLASS STOP SILL GLASS STOP FLAT FILLER SILLFLASHING MULLION SHEAR BLOCK SHEAR BLOCK HEAD RECEPTOR INTERMEDIATEHORIZONTAL GLASS STOP SILL RECEPTOR GLASS STOP SHEAR BLOCK MULLION HEAD INSERT SILL INSERT PICTORIAL VIEW (BACK) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System10 ADMC040EN APRIL, 2024 SCREW SPLINE ASSEMBLY GLASS STOP SILL FLASHING MULLION SILL FLASHING MULLION FILLER SILL FLASHING CLIP MULLION USED AS SILL MULLION FILLER WIDE SIDELIGHT BASE FILLER SILL FLASHING CLIP MULLION FILLER REGLET SILL FLASHING CLIP 4-1/2" x 4-1/2" SILL BRAKE METAL ADAPTER MULLION USED AS SILL REGLET SILL FLASHING CLIP GLASS STOP SILL FLASHING MULLION FILLER SILL FLASHING CLIP MULLION USED AS SILL WIDE SIDELIGHT BASE FILLER SILL FLASHING CLIP SHEAR BLOCK SILL FLASHING REGLET SILL FLASHING CLIP 4-1/2" x 4-1/2" SILL BRAKE METAL ADAPTER MULLION USED AS SILL REGLET SILL FLASHING CLIP SHEAR BLOCK SHEAR BLOCK ASSEMBLY PICTORIAL VIEW (OPTIONAL 451 / 451T SILL ASSEMBLIES USING FILLER AND REGLET SILL FLASHING CLIPS) MULLION The split vertical in the Screw Spline system allows a frame to be installed from unitized assemblies. Screws are driven through the back of the verticals into splines extruded in the horizontal framing members. The Individual units are then snapped together to form a complete frame. The Shear Block system of fabrication allows a frame to be pre-assembled as a single unit. Horizontals are attached to the verticals with shear blocks. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 11 ADMC040EN APRIL, 2024 BASIC FRAMING DETAILS (CENTER - Outside Glazed - Stops Up) .....................................12 (CENTER - Inside Glazed - Stops Down) ...................................13 (CENTER - Outside Glazed - Stops Down) ................................14 PRE-GLAZED FRAMING DETAILS (CENTER - Outside Glazed - Stops Up) .....................................15 (CENTER - Inside Glazed - Stops Down) ...................................16 (CENTER - Outside Glazed - Stops Down) ................................17 MISCELLANEOUS FRAMING .....................................................18-19 CORNERS ..........................................................................................20 CURVING & TRIM DETAILS .............................................................21 ENTRANCE FRAMING .....................................................................22 ENTRANCE FRAMING (OPEN BACK) .............................................23 250T/350T/500T INSULPOUR® THERMAL ENTRANCES .........24-25 GLASSvent® WINDOW for STOREFRONT FRAMING ....................26 8225TL THERMAL WINDOW DETAILS ............................................27 LARGE MISSLE IMPACT ..........................................................28-30 INDEX (CENTER) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 451CG001 [451TCG001] 451CG001 [451TCG001]451CG002[451TCG002]*4-1/2"(114.3) 451CG001[451TCG001](50.8)2"451CG014[451TCG014] 451VG037[451TVG037]* 451CG011[451TCG011]451CG004 (50.8)2"451CG001[451TCG001] 451CG005[451TCG005]4-1/2"(114.3)2"(50.8) 4-1/2"(114.3) 451CG001[451TCG001](50.8)2"451CG011[451TCG011]451CG004 (50.8)2"451CG014[451TCG014] 451VG037[451TVG037]* 451CG001[451TCG001][451TCG005] 451CG005 [451TCG007]2-1/4"(57.15)451CG007[451TCG106]451VG106 5"(127.0) 451CG004 451CG002 451CG003A (50.8)2"451VG006451CG008451CG004[451TCG008][451TVG006]Trifab® VersaGlaze® 451/451T Framing System12 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL TYPICAL TYPICAL BASIC FRAMING DETAILS (CENTER - Outside Glazed - Stops Up) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 451CG001 [451TCG001] 451CG001 [451TCG001]451CG002[451TCG002]*4-1/2"(114.3)2"(50.8)451CG003[451TCG003]451CG004 451CG011[451TCG011]451CG004 451CG001[451TCG001] 451CG005[451TCG005]4-1/2"(114.3)2"(50.8) 451CG003[451TCG003]451CG004 451CG011[451TCG011]451CG004 451CG001[451TCG001][451TCG005] 451CG005 451VG006451CG008 451CG0042-1/4"(57.15)[451TCG008][451TVG006]5"(127.0) 451CG004451CG066 [451TCG065]451CG065 [451TCG066] [451TCG007]2-1/4"(57.15)451CG007[451TCG106]451VG106451CG001[451TCG001] 451VG037[451TVG037]* 451CG365[451TCG365] 451CG014[451TCG014] 451VG037[451TVG037]* Trifab® VersaGlaze® 451/451T Framing System 13 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL TYPICAL TYPICAL BASIC FRAMING DETAILS (CENTER - Inside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG014[451TCG014] 451VG037[451TVG037]* 451CG001[451TCG001]4-1/2"(114.3).2"(50.8) 451CG005[451TCG005] 451CG004 451CG003[451TCG003] 451CG014[451TCG014] 451VG037[451TVG037]* 451CG004 451CG011[451TCG011] 1 4 2 3 5 451CG001[451TCG001]451CG001[451TCG001]451CG002[451TCG002]*4-1/2"(114.3)2"(50.8)451CG003[451TCG003]451CG004 451CG011[451TCG011]451CG004 451VG006451CG008451CG0042-1/4"(57.15)[451TCG008][451TVG006]5"(127.0) 451CG004 451CG066 [451TCG065]451CG065 [451TCG066] [451TCG007]2-1/4"(57.15)451CG007 [451TVG106]451VG106 451CG001[451TCG001][451TCG005]451CG005 Trifab® VersaGlaze® 451/451T Framing System14 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL4JAMB5VERTICAL 1HEAD 2HORIZONTAL 3SILL TYPICAL TYPICAL BASIC FRAMING DETAILS (CENTER - Outside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4 2 5 451CG163[451TCG163] 451CG001[451TCG001](50.8)2"(114.3) 4-1/2"(114.3)4-1/2"(57.2) 2-1/4" 451CG080[451TCG080] (57.2) 2-1/4" 451CG584[451TCG584] 451CG083[451TCG083] 451CG082[451TCG082]451CG581[451TCG581] 2-1/4" (57.2) 451CG011[451TCG011]451CG004 (50.8)2"451CG014[451TCG014]451CG004 451VG037[451TVG037] (114.3) 4-1/2"1/2"2"(12.7)(50.8)6 451VG316[451TVG316] 451VG037[451TVG037]* 451CG365[451TCG365]1/2"2"(12.7)(50.8)(50.8)2"(114.3) 4-1/2" 451CG001[451TCG001] 451VG572 451VG570[451TVG570] 11A 33A Trifab® VersaGlaze® 451/451T Framing System 15 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE PRE-GLAZED FRAMING DETAILS (CENTER - Outside Glazed - Stops Up) Additional information and CAD details are available at www.kawneer.com 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 6JAMB NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3ASILL 1ASTANDARDHEADCOMPENSATING RECEPTOR (EXTERIOR INSTALLED) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 11A 4 2 33A 5 (50.8)2"(114.3) 4-1/2" 451CG163[451TCG163] 451CG004451CG003[451TCG003](50.8)2"451CG011[451TCG011] 451CG004 6 (114.3)4-1/2"(57.2) 2-1/4" 451CG080[451TCG080] (57.2) 2-1/4" 451CG584[451TCG584] 451CG083[451TCG083] 451CG082[451TCG082]451CG581[451TCG581] 2-1/4" (57.2) 451CG001[451TCG001] 451VG037[451TVG037]* 451CG365[451TCG365]1/2"2"(12.7)(50.8)(50.8)2"(114.3) 4-1/2" 451CG004451CG003[451TCG003] 451VG572 451VG570[451TVG570] 451VG316[451TVG316] 451VG037[451TVG037]* 451CG365[451TCG365]1/2"2"(12.7)(50.8)Trifab® VersaGlaze® 451/451T Framing System16 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE PRE-GLAZED FRAMING DETAILS (CENTER - Inside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 6JAMB NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS * HP Sill Flashing shown with optional gasket. 3ASILL 1ASTANDARDHEADCOMPENSATING RECEPTOR (EXTERIOR INSTALLED) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4 2 5 (114.3)4-1/2"(57.2) 2-1/4" 451CG080[451TCG080] (57.2) 2-1/4" 451CG584[451TCG584] 451CG083[451TCG083] 451CG082[451TCG082]451CG581[451TCG581] 2-1/4" (57.2) 6 (50.8)2"(114.3) 4-1/2" 451CG163[451TCG163] 451CG004 451CG003[451TCG003] 451CG011[451TCG011]451CG004(50.8)2"451CG014[451TCG014]451CG004 451VG037[451TVG037] (114.3) 4-1/2"1/2"2"(12.7)(50.8)(50.8)2"(114.3) 4-1/2" 451CG004 451CG003[451TCG003] 451VG572 451VG570[451TVG570] 451CG001[451TCG001] 451VG037[451TVG037]* 451CG365[451TCG365]1/2"2"(12.7)(50.8)11A 33A Trifab® VersaGlaze® 451/451T Framing System 17 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE PRE-GLAZED FRAMING DETAILS (CENTER - Outside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 6JAMB NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3ASILL 1ASTANDARDHEADCOMPENSATING RECEPTOR (EXTERIOR INSTALLED) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG010[451TCG010]451CG540[451TCG540] 451VG029 451VG030 451087 451520450026 451CG005A 451TCG002 451TCG028 450VG006 450VG106 451CG002[451TCG002] 451CG112[451TCG112] 2-1/4"(57.2) 451CG362 451T026 451VG006 451VG106 451CG082[451TCG082]451CG581[451TCG581] 2-1/4" (57.2) 451CG082451CG581 2-3/8" (60.3) 451TCG082451TCG581 2-1/2" (63.5) Trifab® VersaGlaze® 451/451T Framing System18 ADMC040EN APRIL, 2024 EXPANSIONMULLION 1/4" (6.4) INFILLSNAP-IN ADAPTOR 5/8" (15.9) INFILLSNAP-IN ADAPTOR SNAP-IN FLAT POCKET FILLER SNAP-INDOOR STOP SPLIT MULLIONW/ STEEL SNAP-IN FLAT FILLER TUBULARMULLION THERMAL POCKET FILLERS NOTE:If the end reaction of the mullion (mullion spacing (ft.) times height (ft) times specified wind load (psf), divided by two) ismore than 500 LBS., the optional mullion anchor must beused. Consult Application Engineering.OPTIONAL LIGHTWEIGHTCAN RECEPTORS SHALLOW POCKET DEEP POCKET MULLION ANCHOR NOTE:Mullion Anchor not used with Lightweight Receptor. THERMALFLAT FILLER OPTIONAL UNEQUAL LEGCAN RECEPTORS 450110 STEEL REINFORCING MISCELLANEOUS FRAMING (CENTER) Additional information and CAD details are available at www.kawneer.com 451/451T 451W/ STEEL 451TW/ STEEL 400110 STEEL REINFORCING PRE-GLAZED EXPANSION MULLIONS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG570[451TVG570] 451VG573 451VG571[451TVG571] 451VG570[451TVG570] 451VG572 4-1/2"(114.3)4-11/16"(119.0)451CG004 451CG004 450027 451VG037451CG365 2"(50.8) 451027 450028 450031 451027 450029 450031 451VG570[451TVG570] 451VG5722"(50.8)5-1/2"(139.7) 451CG004451CG115 [451TCG035]451CG035 [451TCG115]4-1/2"(114.3)5-3/4" MAX. - 4-1/2" MIN.(146.1) (114.3)8-3/8" MAX. - 7-1/8" MIN.(212.7) (181.0)Trifab® VersaGlaze® 451/451T Framing System 19 ADMC040EN APRIL, 2024 STANDARD HEADCOMPENSATING RECEPTOR(EXTERIOR INSTALLED) HEAVY WEIGHT HEADCOMPENSATING RECEPTOR(EXTERIOR INSTALLED) ONE PIECE HEADCOMPENSATING RECEPTOR JAMBCOMPENSATING RECEPTOR(EXTERIOR INSTALLED) SIDELITE BASE*NARROWSIDELITE BASE *NARROWSIDELITE BASE *NARROW SIDELITE BASES REQUIRE THE USE OF NON-THERMAL 2-PIECE VERTICALS ONLY. NOTE: SIDELITE BASES SHOWN ARE FOR USE WITH SCREW SPLINE AND SHEAR BLOCK SYSTEMS ONLY. SIDELITE BASES ARE NON-THERMAL APPLICATIONS 4-1/2" (114.3) x 4-1/2" (114.3)HORIZONTAL 451VG374 CLIP TYPICALTYPICAL MISCELLANEOUS FRAMING (CENTER) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG015[451TCG015] 451CG015[451TCG015]451CG035[451TCG035] 451CG016[451TCG016] 451CG016[451TCG016] 451CG016[451TCG016] 451CG034 451CG028 451CG028 4-1/2"(114.3)TYP.4-1/2"(114.3)TYP.060119 451CG071[451TCG071] 451CG541[451TCG541]451CG541[451TCG541] 451CG010[451TCG010]451CG010[451TCG010] 451CG071[451TCG071] 451CG541[451TCG541]451CG541[451TCG541] 450017 450017 451CG015 451CG035[451TCG035] [451TCG015] 451CG015[451TCG015] 450017 452CG034[452TCG034] 452CG028[452TCG028]452CG028[452TCG028] 451TCG034 451TCG028 451TCG028 Trifab® VersaGlaze® 451/451T Framing System20 ADMC040EN APRIL, 2024 135o CORNER(NON-THERMAL)135o CORNER(THERMAL) 155o TO 180o PIVOT MULLION(OUTSIDE CORNER)VARIABLE DEGREEBRAKE METAL CORNER 155o TO 180o PIVOT MULLION(INSIDE CORNER) 4-1/2" X 4-1/2" TUBE TWO PIECENO POCKET CORNER ONE POCKETCORNER FOUR POCKET90o CORNER TWO POCKET90o CORNER TWO POCKETCORNER POST THREE POCKET90o CORNER CORNERS (CENTER) 135o CORNER Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 175186 175188 175190 175191 175190 175187 175186 4-1/2"(114.3)2"(50.8)069271 1 2 3 1 2 3 [451TVG150]451VG150 [451TVG150]451VG150 069271 Trifab® VersaGlaze® 451/451T Framing System 21 ADMC040EN APRIL, 2024 STOOL TRIM CLIPWITH HIGH PERFORMANCEFLASHING CURVING DETAILS (Center Plane Only) BRAKE METALADAPTOR AT VERTICAL BRAKE METALADAPTOR AT HORIZONTAL STOOL TRIM BRAKE METAL FILLERS BRAKE METAL FILLERS TYPICALTYPICAL STOOL TRIM CLIPFOR STICK ASSEMBLY CURVING & TRIM DETAILS Seal over Stool Trim fasteners to prevent water infiltration. Additional information and CAD details are available at www.kawneer.com Seal over Stool Trim fasteners to prevent water infiltration. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3) 451CG001[451TCG001](50.8)2"451CG001 069139 451502 451081 450500 069143 451502 451081 450500 4-1/2"(114.3)2"(50.8) 451501 451501 451019 451019 1 3 2 1 3 2 8 9 4 5 10 10 6 7 6 2 10 1 84 3 5 9 3 7 Trifab® VersaGlaze® 451/451T Framing System22 ADMC040EN APRIL, 2024 Trifab® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER® “190” DOORS. NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. SINGLE ACTING DOUBLE ACTING DOUBLE ACTINGDOOR JAMBS SINGLE ACTINGDOOR JAMBS DOUBLE ACTINGHEADERSINGLE ACTINGHEADER Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing. DOOR FRAMING NON-THERMAL ONLY ELEVATIONS ARE NUMBER KEYED TO DETAILS Optional Bottom Rail Sweep TRANSOM HEAD TRANSOM BAR TRANSOM JAMBS 451501 or 451019MULLION 451501 or 451019MULLION 451026INSERT 451026INSERT 450110STEEL(AS REQUIRED) TYPICALTYPICAL 450022STOPS 450022STOPS ENTRANCE FRAMING (CENTER) BOTTOM RAIL Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3) 451CG001[451TCG001](50.8)2"451CG001 451502 451081 450500 451502 451081 450500 10 101 2 1 2 451CG028[451TCG028]451599 451CG002[451TCG002]451599 451064 450126 6 7 4 5 8 9 6 2 10 1 84 3 5 9 3 7 451064 450126 069139 069143 Trifab® VersaGlaze® 451/451T Framing System 23 ADMC040EN APRIL, 2024 Trifab® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER® “190” DOORS. NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. NOTE: Sidelite mullions must be oriented to provide at least one (1) deep vertical pocket per lite to facilitate glazing. DOOR FRAMING NON-THERMAL ONLY Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing.ELEVATIONS ARE NUMBER KEYED TO DETAILS 3 3 OptionalBottom Rail Sweep BOTTOM RAIL SINGLE ACTING DOUBLE ACTING DOUBLE ACTINGDOOR JAMBS SINGLE ACTINGDOOR JAMBS DOUBLE ACTING HEADER SINGLE ACTING HEADER TRANSOM HEAD TRANSOM BAR TRANSOM JAMBS 451599 or 451064MULLION 451599 or 451064MULLION 451026INSERT 451026INSERT 450110STEEL(AS REQUIRED) 451CG028[451TCG028]POCKET INSERT 451CG002[451TCG002]POCKET INSERT TYPICALTYPICAL 450022STOPS 450022STOPS ENTRANCE FRAMING (CENTER - Open Back) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 32 4 5 6 7 8 15, 15A 1 2 3 11 1 3 15, 15A 11 10, 10A 1 2 4 11 9 1 3 10, 10A 11 9 7 866 5 12 14 13 Trifab® VersaGlaze® 451/451T Framing System24 ADMC040EN APRIL, 2024 250T/350T/500T INSULPOUR® THERMAL ENTRANCES NOTE:1. SERIES 250T NARROW STILE DOORS ARE DETAILED, MEDIUM STILE 350T DOORS AND WIDE STILE 500T DOORS ALSO MAY BE USED. 2. TRIFAB® VERSAGLAZE® 451T CENTER, 2" x 4-1/2" (50.8 x 114.3) FRAMING IS DETAILED WITH THE DOORS FOR REFERENCE. OTHER KAWNEER FRAMING SERIES OR CURTAIN WALL SYSTEMS MAY BE USED. 534007TRANSOM GLASS STOP SINGLE ACTING DOORS Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 9 11 10A 14 13 15 12 11 15A 10 2-1/4"(57.2)2-1/4"(57.2)Trifab® VersaGlaze® 451/451T Framing System 25 ADMC040EN APRIL, 2024 OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING 450022GLASS STOPS 450022GLASS STOPS SINGLE ACTING DOORS COC WITH SINGLE ACTING OFFSET ARM SURFACE OVERHEAD CLOSER CONSEALED OVERHEAD CLOSER Additional information and CAD details are available at www.kawneer.com 250T/350T/500T INSULPOUR® THERMAL ENTRANCES kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 2 3 5 7 6 4 8 451CG001 469407 [451TCG001] 451CG011[451TCG011] 469407 451CG004 [451TCG001]451CG001 469407451CG001 469407[451TCG001]451CG002[451TCG002]451CG001 469407 [451TCG001] 451CG002[451TCG002] 451CG001 469407[451TCG001]451CG002[451TCG002]469407 451CG004 451CG014[451TCG014]451VG037[451TVG037]* [451TCG001]451CG001 450026 1 2 3 4 5 76 8 Trifab® VersaGlaze® 451/451T Framing System26 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS OUTSWING CASEMENT VERTICAL SECTION OUTSWING CASEMENT HORIZONTAL SECTION PROJECT-OUT HORIZONTAL SECTION PROJECT-OUT VERTICAL SECTION NOTE: Black spacer is recommended when 1" (25.4) insulating glass is used. GLASSvent ® WINDOW for STOREFRONT FRAMING (CENTER) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant (by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 3 2 4 451T026 451TCG001 469407 451TCG011451CG004 469407 451TCG001 451TCG002 469407 451TCG001 451TCG002 1 2 3 4 Trifab® VersaGlaze® 451/451T Framing System 27 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS PROJECT-OUTVERTICAL SECTION PROJECT-OUTHORIZONTAL SECTION 8225TL THERMAL WINDOWS SHOWNNOTE: OTHER VENT TYPES CAN BEACCOMMODATED, CONSULT YOUR KAWNEER REPRESENTATIVE FOR OTHER OPTIONS 8225TL THERMAL WINDOWS (CENTER) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 451CG015[451TCG015] 451CG015[451TCG015] 451CG540[451TCG540]451CG010A[451TCG010A] 451CG003[451TCG003]451CG004 451CG363 451CG011[451TCG011]451CG004 451CG001[451TCG001]451CG363451CG001[451TCG001] 451HP037[451THP037]* 451HP127 451CG001A[451TCG001A] 451CG002[451TCG002]* 451CG013[451TCG013] 451CG002[451TCG002]* 451CG113[451TCG113] 451CG002[451TCG002]* 451CG001[451TCG001] 451CG002[451TCG002]* 451CG015 451CG035[451TCG035] [451TCG015]451CG015 451CG035[451TCG035] [451TCG015] 452CG034[452TCG034] 452CG028[452TCG028]452CG028[452TCG028] Trifab® VersaGlaze® 451/451T Framing System28 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS SCREW SPLINE OPTIONAL FRAMING (CENTER) 5VERTICAL 5VERTICAL4JAMB5VERTICAL 1HEAD 2HORIZONTAL 3SILL BASIC FRAMING DETAILS (CENTER - Outside Glazed - Stops Down) LEVEL D - LARGE MISSILE IMPACT 5VERTICAL TWO POCKET CORNER POST TUBULAR EXPANSION MULLION TWO POCKET OUTSIDE CORNER POST TWO POCKET INSIDE CORNER POST Hurricane Resistant Product 135o CORNER Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 3 2 451CG001[451CG001] 451CG363 451079 041049 451502 041045 451079 451502 2A 6 2 2A 1 4 3 5 9 3 7 8 2 11 3 8 1 7 10 5A 2A 11 3 8 9 Trifab® VersaGlaze® 451/451T Framing System 29 ADMC040EN APRIL, 2024 SINGLE ACTING HEADER ELEVATIONS ARE NUMBER KEYED TO DETAILS Optional Bottom Rail Sweep TRANSOM HEAD TRANSOM BAR 450022STOPS 450022STOPS ENTRANCE FRAMING (CENTER) LEVEL D - LARGE MISSILE IMPACT SINGLE ACTING BOTTOM RAIL CONCEALED OVERHEAD CLOSERS 450022STOPS 450022STOPS Hurricane Resistant Product Trifab® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER® “350/500 IR” DOORS (DRY GLAZED). NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. DOOR FRAMING NON-THERMAL ONLY Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 10 5A 8 9 4 5 6 7 11 Trifab® VersaGlaze® 451/451T Framing System30 ADMC040EN APRIL, 2024 SINGLE ACTINGDOOR JAMBS ENTRANCE FRAMING (CENTER) LEVEL D - LARGE MISSILE IMPACT SINGLE ACTINGDOOR JAMBS MEETING STILES Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing. TRANSOM JAMBS 575054DOOR JAMB 575054DOOR JAMB 451026INSERT 451026INSERT 575300 & 575301STEEL(AS REQUIRED) 450126POCKET INSERT 451CG002POCKET INSERT 575054DOOR JAMB 450126POCKET INSERT 575054DOOR JAMB 450126POCKET INSERT 575054DOOR JAMB 451026INSERT 451CG002POCKET INSERT 575054DOOR JAMB 451026INSERT451CG002POCKET INSERT 575054DOOR JAMB 451CG002POCKET INSERT 575054DOOR JAMB 451CG002POCKET INSERT 575300 & 575301STEEL(AS REQUIRED) Hurricane Resistant Product Trifab® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER® “350/500 IR” DOORS (DRY GLAZED). NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. DOOR FRAMING NON-THERMAL ONLY Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 31 ADMC040EN APRIL, 2024 BASIC FRAMING DETAILS (FRONT - Inside Glazed - Stops Down) .....................................32 (FRONT - Outside Glazed - Stops Down) ..................................33 STICK ...........................................................................................34-36 PUNCHED OPENING ..................................................................37-38 MISCELLANEOUS FRAMING .....................................................39-40 CORNERS ....................................................................................41-42 ENTRANCE FRAMING ......................................................................43 GLASSvent® WINDOW for STOREFRONT FRAMING ....................44 8225TL THERMAL WINDOW DETAILS ............................................45 INDEX (FRONT) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 451VG001[451TVG001]451VG0264-1/2"(114.3)2"(50.8) 451VG012[451TVG012] 4-1/2"(114.3)2"(50.8)451VG104 451VG103[451TVG103] 451FG014[451TFG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 451VG001[451TVG001]451VG005[451TVG005] 451VG104 [451TVG103]451VG103 451FG014[451TFG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG104 451VG108[451TVG108] 451VG006[451TVG006] 451VG111[451TVG111] 451VG104 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)451VG001[451TVG001]451VG005[451TVG005] Trifab® VersaGlaze® 451/451T Framing System32 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL4JAMB5VERTICAL 1HEAD 2HORIZONTAL 3SILL SCREW SPLINE SHEAR BLOCK STICK TYPICALTYPICALBASIC FRAMING DETAILS (FRONT - Inside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG001[451TVG001]451VG0264-1/2"(114.3)2"(50.8) 451VG012[451TVG012] 4-1/2"(114.3)2"(50.8)451VG004 451VG003[451TVG003] 451FG014[451TFG014] 451VG037[451TVG037]* 451VG011[451TVG011] 451VG004 451VG026 451VG001[451TVG001]451VG005[451TVG005] 451VG003[451TVG003]451VG004 451FG014[451TFG014] 451VG037[451TVG037]* 451VG011[451TVG011] 451VG004 451VG026 1 4 2 3 5 451VG001[451TVG001]451VG005[451TVG005] 4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG004 451VG008[451TVG008] 451VG006[451TVG006] 451VG011[451TVG011] 451VG004 451VG026 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)Trifab® VersaGlaze® 451/451T Framing System 33 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL4JAMB5VERTICAL 1HEAD 2HORIZONTAL 3SILL TYPICALTYPICAL BASIC FRAMING DETAILS (FRONT - Outside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 2"(50.8)4-1/2"(114.3)451VG132 451VG134 451VG104 451VG108 451VG006 451SSG111 451VG104 [451TVG007] 451VG106 451VG131 [451TVG132][451TVG134] [451TVG006] [451TVG108] 451VG130 [451TSSG111]451SSG004 451VG007 [451TVG106] 451VG130 451VG131 451SSG005 451VG104 451VG108 451VG006 451SSG111 451VG104 [451TVG007] 451VG106 451SSG250 451SSG005 451SSG005 451SSG129[451TSSG129] [451TVG006] [451TVG108] 451SSG328[451TSSG328] [451TSSG111]451SSG004 451VG007 [451TVG106] 451SSG328[451TSSG328] 451VG130 451VG130 1A 4 2 3 5 5A 5B 4A 1 2A 3A Trifab® VersaGlaze® 451/451T Framing System34 ADMC040EN APRIL, 2024 1HEAD 2HORIZONTAL 3SILL 1AHEAD 2AHORIZONTAL 3ASILL 4JAMB 5VERTICAL 5ASSGVERTICAL 5BWEATHERSEALVERTICAL 4ASSGJAMB STICK (INSIDE GLAZED) TWO COLOR OPTION STANDARD RECEPTOR with SSG ADAPTOR ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS TYPICAL TYPICALBASIC FRAMING DETAILS (FRONT) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant(by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 2" (50.8)4-1/2"(114.3)451SSG005 451SSG104 451SSG008 451SSG006 451SSG111 451VG104 451SSG007 [451TSSG106] [451TSSG129] 451SSG005 451SSG250 451SSG005 451SSG129 [451TSSG006] [451TSSG111] 451SSG004 451SSG106 451SSG425 2"(50.8)4-1/2"(114.3)451SSG005 451SSG005 451SSG007 451SSG106 451SSG111 451VG104 451SSG007 451SSG106 451SSG129[451TSSG129] [451TSSG106] [451TSSG111]451SSG004 [451TSSG106]451SSG425 1 4 2 3 5 Trifab® VersaGlaze® 451/451T Framing System 35 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS STICK (INSIDE GLAZED) SSG RECEPTOR STICK (OUTSIDE GLAZED) SSG RECEPTOR 4JAMB 5SSGVERTICAL 5WEATHERSEALVERTICAL 4JAMB 5SSGVERTICAL 1HEAD 2HORIZONTAL 3SILL 1HEAD 2HORIZONTAL 3SILL TYPICAL TYPICALTYPICAL TYPICALBASIC FRAMING DETAILS (FRONT) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant(by Others)*Structural Silicone Sealant(by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 2"(50.8)4-1/2"(114.3)451SSG129 451SSG005 451SSG104 451SSG008 451SSG006 451SSG007 451SSG005 451SSG005 [451TSSG129] 451SSG250 [451TSSG006] 451VG130 [451TSSG106]451SSG106451VG130 451SSG425 451SSG111 451VG104 [451TSSG111]451SSG004 Trifab® VersaGlaze® 451/451T Framing System36 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS 4JAMB 5SSGVERTICAL 1HEAD 2HORIZONTAL 3SILL STICK (INSIDE GLAZED) TWO COLOR OPTION SSG RECEPTOR 5WEATHERSEALVERTICAL TYPICAL TYPICALBASIC FRAMING DETAILS (FRONT) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant(by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 [451TVG101]451VG101 4-1/2"(114.3)2"(50.8) 451VG005[451TVG005] 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 451VG111[451TVG111] 451VG104 [451TVG101]451VG101 451SSG425 451VG104 451VG327 [451TVG103]451VG103 1 4 2 3 5 Trifab® VersaGlaze® 451/451T Framing System 37 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1AHEAD CONTINUOUS HEAD AND SILL (INSIDE GLAZED) PUNCHED OPENING TYPICAL TYPICALBASIC FRAMING DETAILS (FRONT) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 [451TVG101]451VG101 451SSG425 451SSG111[451TSSG111] 451VG104451SSG004 451VG104 451VG327 [451TVG103]451VG103 [451TVG101]451VG101 2"(50.8) 451SSG005 451SSG005 451SSG250 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 1 4 2 3 5 Trifab® VersaGlaze® 451/451T Framing System38 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS CONTINUOUS HEAD AND SILL (INSIDE GLAZED) SSG \ WEATHERSEAL PUNCHED OPENING 2HORIZONTAL 3SILL 4JAMB 5SSGVERTICAL 1HEAD 5WEATHERSEAL VERTICAL 1AHEAD TYPICALTYPICALBASIC FRAMING DETAILS (FRONT) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant(by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG010[451TVG010]451VG540[451TVG540] 451VG029 451VG030 451087 452145 451VG010A[451TVG010A]451VG540[451TVG540]451VG010A[451TVG010A]451VG540[451TVG540] 451T026 451VG570[451TVG570] 451VG572 451VG570[451TVG570] 451VG573 451VG570[451TVG570] 451VG572 451VG571 [451TVG571] Trifab® VersaGlaze® 451/451T Framing System 39 ADMC040EN APRIL, 2024 EXPANSION MULLION 1/4" (6.4) INFILLSNAP-IN ADAPTOR 5/8" (15.9) INFILLSNAP-IN ADAPTOR PVC FLAT FILLER(NON STRUCTURAL)SNAP-IN FLAT FILLER HEAVY WEIGHT - HEAD COMPENSATING RECEPTOR TUBULAREXPANSION MULLION TUBULAREXPANSION MULLIONWITH STEEL THERMALFLAT FILLER JAMB COMPENSATING RECEPTOR(EXTERIOR INSTALLED) STANDARD - HEADCOMPENSATING RECEPTOR(EXTERIOR INSTALLED) ONE PIECE - HEADCOMPENSATING RECEPTOR 451VG374 CLIP MISCELLANEOUS FRAMING (FRONT) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 [451TVG150]451VG150 069271 450VG006 450VG106 451VG362 451SSG362 069271 451VG006 451VG106 451VG150 451VG150 451CG366 Trifab® VersaGlaze® 451/451T Framing System40 ADMC040EN APRIL, 2024 BRAKE METALADAPTOR STOOL TRIM CLIPwith HP FLASHING SSG MULLION ANCHOR OPTIONAL LIGHTWEIGHTCAN RECEPTORS MULLION ANCHOR NOTE:If the end reaction of the mullion (mullion spacing (ft.)times height (ft) times specified wind load (psf), divided by two) is more than 500 LBS., the optional MullionAnchor must be used. Consult Application Engineering. NOTE: Mullion Anchor not used with Lightweight Receptor. STOOL TRIM CLIPFOR STICK ASSEMBLY OPTIONAL UNEQUAL LEGCAN RECEPTORS MISCELLANEOUS FRAMING (FRONT) Seal over Stool Trim fasteners to prevent water infiltration. Additional information and CAD details are available at www.kawneer.com Seal over Stool Trim fasteners to prevent water infiltration. BRAKE METALFILLERS BRAKE METALFILLERS BRAKE METAL ADAPTORAT HORIZONTAL kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG010[451TVG010]451VG010[451TVG010]451VG010[451TVG010]451VG010[451TVG010] 451SSG035 451SSG016 451SSG015 3-3/16"(80.9) 451SSG115451SSG116 451SSG135 450017 451VG015[451TVG015] 451VG015[451TVG015] 451VG035[451TVG035] 4-1/2"(114.3)TYP.4-1/2"(114.3)TYP.060119 451VG010[451TVG010]451VG010[451TVG010] 450017 450017 Trifab® VersaGlaze® 451/451T Framing System 41 ADMC040EN APRIL, 2024 135o CORNER VARIABLE DEGREEBRAKE METALOUTSIDE CORNER 4-1/2" X 4-1/2" TUBE TWO PIECE NO POCKET CORNER ONE POCKET CORNER 90o CORNER TWO POCKET90o CORNER TWO POCKETCORNER POST VARIABLE DEGREE BRAKE METALINSIDE CORNER BRAKE METAL FILLERS BRAKE METAL FILLERS BRAKE METAL FILLERS CORNERS (FRONT) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451SSG016451SSG015451SSG005 451SSG005 451SSG116 451SSG115 451SSG 0 0 5 451S S G 0 0 5 451SSG016451SSG015451SSG005 451SSG005 451SSG116 451SSG115 451SSG 0 0 5 451S S G 0 0 5 Trifab® VersaGlaze® 451/451T Framing System42 ADMC040EN APRIL, 2024 90o INSIDE CORNER90o OUTSIDE CORNER 135o INSIDE CORNER135o OUTSIDE CORNER CORNERS (FRONT - SSG) INSIDE GLAZED OUTSIDE GLAZED 90o INSIDE CORNER90o OUTSIDE CORNER 135o INSIDE CORNER135o OUTSIDE CORNER Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant (by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 6 2 10 1 84 3 5 9 3 7 4-1/2"(114.3)2"(50.8)451VG001 451VG001 451502451VG004450022 451VG022 451081 450500451VG004450022 451VG022 451502 451081 450500 4-1/2"(114.3)2"(50.8) 451VG019 069177 451VG019 069177 451VG019 451VG019 1 3 2 1 3 2 8 9 4 5 10 10 6 7 451VG019 451VG033 451VG019 069139 069143 Trifab® VersaGlaze® 451/451T Framing System 43 ADMC040EN APRIL, 2024 NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. ELEVATIONS ARE NUMBER KEYED TO DETAILS Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert. DOOR FRAMING NON-THERMAL ONLY BOTTOM RAIL SINGLE ACTING DOUBLE ACTING DOUBLE ACTINGDOOR JAMBS SINGLE ACTINGDOOR JAMBS DOUBLE ACTINGHEADERSINGLE ACTINGHEADER TRANSOM HEAD TRANSOM BAR TRANSOM JAMBS Optional Bottom Rail Sweep TYPICAL TYPICALENTRANCE FRAMING (FRONT) Additional information and CAD details are available at www.kawneer.com Trifab® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER “190” DOORS. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG011[451TVG011] 451VG026 451VG004 469407 451VG003[451TVG003] 451VG004 469407 451VG005[451TG005] 469407 451VG005[451TVG005] 469407 469407451FG014[451TFG014]451VG037[451TVG037]* 451VG011[451TVG011] 451VG026451VG004469407 451VG005[451TG005] 469407 451VG005[451TVG005] 469407 1 2 3 5 7 6 4 8 Trifab® VersaGlaze® 451/451T Framing System44 ADMC040EN APRIL, 2024 5 76 8 1 2 3 4 OUTSWING CASEMENTHORIZONTAL SECTION PROJECT-OUTHORIZONTAL SECTION ELEVATION IS NUMBER KEYED TO DETAILS OUTSWING CASEMENT VERTICAL SECTION PROJECT-OUTVERTICAL SECTION NOTE: Black spacer is recommended when 1" insulating glass is used. GLASSvent ® WINDOW for STOREFRONT FRAMING (FRONT) Additional information and CAD details are available at www.kawneer.com Structural Silicone Sealant(by Others)* * INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulating Glass Unit Manufacturer. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TVG001 451T026 469407 451TVG011 451VG004 451VG026 451TVG012 451VG026 469407 451TVG012 451VG026 469407 1 2 3 4 1 3 2 4 Trifab® VersaGlaze® 451/451T Framing System 45 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS 8225TL THERMAL WINDOWS (FRONT) PROJECT-OUT VERTICAL SECTION PROJECT-OUTHORIZONTAL SECTION 8225TL THERMAL WINDOWS SHOWNNOTE: OTHER VENT TYPES CAN BE ACCOMMODATED, CONSULT YOUR KAWNEERREPRESENTATIVE FOR OTHER OPTIONS Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System46 ADMC040EN APRIL, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 47 ADMC040EN APRIL, 2024 BASIC FRAMING DETAILS (BACK - Inside Glazed - Stops Down) .......................................48 (BACK - Outside Glazed - Stops Down) ....................................49 MISCELLANEOUS FRAMING .....................................................50-51 CORNERS ..........................................................................................52 ENTRANCE FRAMING ......................................................................53 INDEX (BACK) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 4 2 3 5 451VG0264-1/2"(114.3)2"(50.8) 451VG012[451TVG012] 4-1/2"(114.3)2"(50.8)451VG004451VG003[451TVG003 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG011[451TVG011]451VG004451VG026 451VG001[451TVG001]451VG005[451TVG005]451VG004451VG003[451TVG003] 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG011[451TVG011]451VG004451VG026 451VG001[451TVG001] 4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG004451VG008[451TVG008] 451VG006[451TVG006] 451VG011[451TVG011] 451VG004451VG026 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)451VG001[451TVG001] 451VG005[451TVG005] Trifab® VersaGlaze® 451/451T Framing System48 ADMC040EN APRIL, 2024 ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL TYPICALTYPICALBASIC FRAMING DETAILS (BACK - Inside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG001[451TVG001]451VG0264-1/2"(114.3)2"(50.8) 451VG012[451TVG012] 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 451VG001[451TVG001]451VG005[451TVG005] 451VG104 [451TVG103]451VG103 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 1 4 2 3 5 4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG104 451VG108[451TVG108]451VG006[451TVG006]451VG111[451TVG111] 451VG104 451VG001[451TVG001]451VG005[451TVG005] 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)Trifab® VersaGlaze® 451/451T Framing System 49 ADMC040EN APRIL, 2024 1HEAD 2HORIZONTAL 4JAMB 5VERTICAL 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL ELEVATION IS NUMBER KEYED TO DETAILS NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL SCREW SPLINE SHEAR BLOCK STICK 1HEAD 2HORIZONTAL 3SILL 4JAMB 5VERTICAL TYPICALTYPICAL BASIC FRAMING DETAILS (BACK - Outside Glazed - Stops Down) Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG010[451TVG010]451VG540[451TVG540] 451VG029 451VG030 451087 452145 451VG570[451TVG570] 451VG572 451VG010A[451TVG010A]451VG540[451TVG540]451VG010A[451TVG010A]451VG540[451TVG540] 451T026 451VG570[451TVG570] 451VG573 451VG571 [451TVG571] 451VG570[451TVG570] 451VG572 Trifab® VersaGlaze® 451/451T Framing System50 ADMC040EN APRIL, 2024 EXPANSION MULLION 1/4" (6.4) INFILL SNAP-IN ADAPTOR 5/8" (15.9) INFILLSNAP-IN ADAPTOR PVC FLAT FILLER (NON STRUCTURAL) SNAP-IN FLAT FILLER TUBULAREXPANSION MULLION TUBULAREXPANSION MULLIONWITH STEEL THERMALFLAT FILLER HEAVY WEIGHT - HEADCOMPENSATING RECEPTOR (EXTERIOR INSTALLED) JAMBCOMPENSATING RECEPTOR (EXTERIOR INSTALLED) STANDARD - HEADCOMPENSATING RECEPTOR STANDARD - HEADCOMPENSATING RECEPTOR 451VG374 CLIP MISCELLANEOUS FRAMING (BACK) Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 [451TVG150]451VG150 451VG640 069271 451VG326 450VG006 450VG106 451VG006 451VG106 069271 451VG150 451VG150 451CG366 Trifab® VersaGlaze® 451/451T Framing System 51 ADMC040EN APRIL, 2024 OPTIONAL LIGHTWEIGHTCAN RECEPTORS BRAKE METALADAPTOR STOOL TRIM CLIPwith HP FLASHING MULLION ANCHOR NOTE:If the end reaction of the mullion (mullion spacing (ft.)times height (ft) times specified wind load (psf), divided by two) is more than 500 LBS., the optional MullionAnchor must be used. Consult Application Engineering. NOTE: Mullion Anchor not used with Lightweight Receptor. OPTIONAL UNEQUAL LEG CAN RECEPTORS MISCELLANEOUS FRAMING (BACK) STOOL TRIM CLIPFOR STICK ASSEMBLY Seal over Stool Trim fastenersto prevent water infiltration.Seal over Stool Trim fasteners to prevent water infiltration. Additional information and CAD details are available at www.kawneer.com BRAKE METALFILLERS BRAKE METALFILLERS BRAKE METAL ADAPTORAT HORIZONTAL STOOL TRIM kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG010[451TVG010]451VG010[451TVG010] 451VG010[451TVG010]451VG010[451TVG010] 451VG010[451TVG010]451VG010[451TVG010] 450017 451VG015[451TVG015] 451VG010[451TVG010] 451VG010[451TVG010] 4-1/2"(114.3)TYP.4-1/2"(114.3)TYP.060119 451VG010[451TVG010] 451VG010[451TVG010] 450017 450017 Trifab® VersaGlaze® 451/451T Framing System52 ADMC040EN APRIL, 2024 135o INSIDECORNER135o OUTSIDE CORNER INSIDE90o CORNER 4-1/2" X 4-1/2" TUBE TWO PIECENO POCKET CORNER ONE POCKETCORNER OUTSIDE 90o CORNER TWO POCKET CORNER POST BRAKE METAL FILLERS BRAKE METAL FILLERS BRAKE METAL FILLERS BRAKE METAL FILLERS BRAKE METAL FILLERS CORNERS (BACK) Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 2"(50.8)4-1/2"(114.3) 451VG001 451VG001 069139 451502 451VG004 450022 451VG022 451081 450500 451VG004 450022 451VG022 069143 451502 451081 450500 4-1/2"(114.3)2"(50.8) 451VG019 069177 451VG019 069177 451VG019 451VG019 451VG033 451VG019 451VG019 1 3 2 1 3 2 8 9 4 5 10 10 6 7 6 2 10 1 84 3 5 9 3 7 Trifab® VersaGlaze® 451/451T Framing System 53 ADMC040EN APRIL, 2024 NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert. DOOR FRAMING NON-THERMAL ONLY ELEVATIONS ARE NUMBER KEYED TO DETAILS BOTTOM RAIL SINGLE ACTING DOUBLE ACTING DOUBLE ACTINGDOOR JAMBS SINGLE ACTING DOOR JAMBS DOUBLE ACTINGHEADER SINGLE ACTING HEADER TRANSOM HEAD TRANSOM BAR TRANSOM JAMBS OptionalBottom Rail Sweep TYPICAL TYPICALENTRANCE FRAMING (BACK) Additional information and CAD details are available at www.kawneer.com TRIFAB® VersaGlaze® 451 FRAMING INCORPORATING KAWNEER “190” DOORS. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System54 ADMC040EN APRIL, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 55 ADMC040EN APRIL, 2024 INDEX (MULTI-PLANE) BASIC FRAMING DETAILS SCREW SPLINE SYSTEM (MULTI-PLANE - Inside Glazed - Stops Down) ..........................56 (MULTI-PLANE - Outside Glazed - Stops Down) .......................57 SHEAR BLOCK SYSTEM (MULTI-PLANE - Inside Glazed - Stops Down) ..........................58 (MULTI-PLANE - Outside Glazed - Stops Down) .......................59 STICK SYSTEM (MULTI-PLANE - Inside Glazed - Stops Down) ..........................60 (MULTI-PLANE - Outside Glazed - Stops Down) .......................61 (See appropriate Center, Front or Back Section for Miscellaneous Details.) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3)2"(50.8)451VG104 451VG103[451TVG103] 451FG014[451TFG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 4-1/2"(114.3)2"(50.8)451VG004451VG003[451TVG003 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG011[451TVG011]451VG004451VG026 4-1/2"(114.3)2"(50.8)451CG003[451TCG003]451CG004 451CG011[451TCG011]451CG004 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001451VG069[451TVG069] 451VG001[451TVG001]451VG052 451CG028451TVG052 451TCG028451TCG002451TVG001 451CG014[451TCG014] 451VG037[451TVG037]* Trifab® VersaGlaze® 451/451T Framing System56 ADMC040EN APRIL, 2024 SCREW SPLINE ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BACKFRONT CENTER BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed - Stops Down) FRONT BACK CENTER Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. FRONT kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3)2"(50.8)451VG004 451VG003[451TVG003] 451FG014[451TFG014] 451VG037[451TVG037]* 451VG011[451TVG011] 451VG004 451VG026 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 4-1/2"(114.3)2"(50.8)451CG003[451TCG003] 451CG004 451CG014[451TCG014] 451VG037[451TVG037]* 451CG011[451TCG011]451CG004 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001451VG069[451TVG069]451VG001[451TVG001]451VG052 451CG028451TVG052 451TCG028451TCG002451TVG001 Trifab® VersaGlaze® 451/451T Framing System 57 ADMC040EN APRIL, 2024 SCREW SPLINE ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARE THERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) BACK CENTERFRONT See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed - Stops Down) FRONT BACK FRONTCENTER Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 451FG014[451TFG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 4-1/2"(114.3)2"(50.8)451VG004451VG003[451TVG003] 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG011[451TVG011]451VG004451VG026 2"(50.8)451CG004451CG003[451TCG003] 4-1/2"(114.3) 451CG011[451TCG011]451CG004 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001 451VG069[451TVG069]451VG001[451TVG001]451TVG052 451TCG028451VG052 451CG028451TVG001 451TCG002451CG014[451TCG014] 451VG037[451TVG037]* Trifab® VersaGlaze® 451/451T Framing System58 ADMC040EN APRIL, 2024 SHEAR BLOCK ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) FRONT BACK CENTER See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed - Stops Down) FRONT BACK CENTER FRONT Note: Transition verticals are required to be two piece Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 4-1/2"(114.3)2"(50.8)451VG003[451TVG003]451VG004 451FG014[451TFG014] 451VG037[451TVG037]* 451VG011[451TVG011] 451VG004 451VG026 4-1/2"(114.3)2"(50.8)451VG104 [451TVG103]451VG103 451BG014 451BG004 [451TBG014] 451VG037[451TVG037]* 451VG111[451TVG111] 451VG104 451CG004 4-1/2"(114.3)2"(50.8)451CG003[451TCG003] 451CG014[451TCG014] 451VG037[451TVG037]* 451CG004 451CG011[451TCG011] 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001 451VG069[451TVG069] 451VG001[451TVG001]451TVG052 451TCG028451VG052 451CG028451TVG001 451TCG002Trifab® VersaGlaze® 451/451T Framing System 59 ADMC040EN APRIL, 2024 SHEAR BLOCK ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) FRONT BACK CENTER See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed - Stops Down) FRONT BACK CENTER FRONT Note: Transition verticals are required to be two piece. Additional information and CAD details are available at www.kawneer.com * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001 451VG069[451TVG069]451VG001[451TVG001]451TVG052 451TCG028451VG052 451CG028451TVG001 451TCG0024-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG104 451VG108[451TVG108] 451VG006[451TVG006] 451VG111[451TVG111] 451VG104 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG004451VG008[451TVG008] 451VG006[451TVG006] 451VG011[451TVG011] 451VG004451VG026 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)451VG006451CG008 451CG0042-1/4"(57.15)[451TCG008][451TVG006]5"(127.0) 451CG004451CG066 [451TCG065]451CG065 [451TCG066] [451TCG007]2-1/4"(57.15)451CG007[451TCG106]451VG106 Trifab® VersaGlaze® 451/451T Framing System60 ADMC040EN APRIL, 2024 STICK ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) FRONT BACK CENTER See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed - Stops Down) FRONT BACK CENTER FRONT Note: Transition verticals are required to be two piece Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 11 13 141210 1 2 3 7 8 9 4 5 6 451VG001[451TVG001]4-1/2"(114.3)2"(50.8)451CG002451VG001451VG069[451TVG069] 451VG001[451TVG001]451TVG052 451TCG028451VG052 451CG028451TVG001 451TCG0024-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG004 451VG008[451TVG008] 451VG006[451TVG006] 451VG011[451TVG011] 451VG004 451VG026 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)4-1/2"(114.3)2-1/4"(57.2)5"(127) 451VG104 451VG108[451TVG108]451VG006[451TVG006]451VG111[451TVG111] 451VG104 451VG007[451TVG007] 451VG106[451TVG106]2-1/4"(57.2)451VG006451CG008451CG0042-1/4"(57.15)[451TCG008][451TVG006]5"(127.0) 451CG004 451CG066 [451TCG065]451CG065 [451TCG066] [451TCG007]2-1/4"(57.15)451CG007 [451TVG106]451VG106 Trifab® VersaGlaze® 451/451T Framing System 61 ADMC040EN APRIL, 2024 STICK ASSEMBLY 1HEAD 2HORIZONTAL 4HEAD 5HORIZONTAL 6SILL 7HEAD 8HORIZONTAL 9SILL NUMBERS IN BRACKETS ARETHERMALLY BROKEN MEMBERS 3SILL ELEVATION IS NUMBER KEYED TO DETAILS 10JAMB 12VERTICAL11VERTICAL 14JAMB13VERTICAL13VERTICAL (THERMAL) 12VERTICAL (THERMAL) FRONT BACK CENTER See Pages 12 thru 30 for all CENTER details.See Pages 48 thru 53 for all BACK details.See Pages 32 thru 45 for all FRONT details. BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed - Stops Down) FRONT BACK CENTER FRONT Note: Transition verticals are required to be two piece. Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 450026[451T026] 451CG001[451TCG001]451CG001[451TCG001]451CG002[451TCG002]450026[451T026] 451CG001[451TCG001]451CG001[451TCG001]451CG002[451TCG002]451CG001[451TCG001]451CG001[451TCG001]451CG002[451TCG002]451CG003[451TCG003]451CG004 451CG003[451TCG003]451CG004 451CG003[451TCG003]451CG004 450026[451T026] 451CG004 451CG014[451TCG014] 451VG037[451TVG037]* 451CG004 451CG014[451TCG014] 451VG037[451TVG037]* 451CG004 451CG014[451TCG014] 451VG037[451TVG037]*451VG570[451TVG570]451VG572451VG570[451TVG570]451VG572451VG570[451TVG570] 451VG572 4-1/2" (114.3)2"(50.8)5-1/2" (139.7)3"(76.2)4-1/2"(114.3)2" (50.8) Trifab® VersaGlaze® 451/451T Framing System62 ADMC040EN APRIL, 2024 CONTINUOUS HEAD AND JAMB MULLION FILLERS HEAD RECEPTOR WITH CONTINUOUS JAMB FILLERS(EXTERIOR INSTALLED) HEAD AND JAMB RECEPTORS (EXTERIOR INSTALLED) 1HEAD 3SILL 4JAMB 5VERTICAL 1HEAD 3SILL 4JAMB 5VERTICAL4JAMB5VERTICAL 1HEAD 3SILL TYPICAL TYPICAL AIR/VAPOR BARRIER TIE-IN OPTION * HP Sill Flashing shown with optional gasket.* HP Sill Flashing shown with optional gasket. The following applications utilize Tremco Proglaze® ETA Connections as the transition assembly from the wall air/vapor barrier membrane to the storefront framing perimeter. Corners are sealed with either Proglaze® ETA 3D molded silicone corners or lapped Proglaze® ETA silicone sheet material. Transition assembly components are set in Tremco Spectrem® 1 silicone sealant. For complete installation instructions of Tremco Proglaze® ETA products, contact your local Tremco representative or visit www.tremcosealants.com. For integration of a silicone engineered transition assembly, the Trifab® storefront system must use continuous head and jamb mullion fillers, a head receptor with continuous jamb fillers or a head receptor with jamb receptors. Reference air/vapor barrier installation instructions 451VG977EN. All storefront framing to be installed according to applicable Kawneer storefront system installation instructions, project specific plans, specifications and shop details. Storefront installations require the sill to be structurally supported directly under the glass setting blocks and mullion locations, as well as where the sill is anchored to the substrate. Any projecting or cantilevered sill applications that are not supported must be reviewed by Kawneer application engineering. Installer to independently confirm sealant compatibility and adhesion with all job specific storefront framing materials, silicone ETA sheet material and wall AVB material. (451 center plane details shown, 451T and front/back/multi-plane similar. * HP Sill Flashing shown with optional gasket. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System 63 ADMC040EN APRIL, 2024 INDEX (CHARTS) WIND LOAD CHARTS (CENTER) TF VG 451 (Non-Thermal) ........................................................65-69 TF VG 451T (Thermal) ..............................................................70-74 WIND LOAD CHARTS (FRONT or BACK) TF VG 451 (Non-Thermal) ........................................................75-78 TF VG 451T (Thermal) ..............................................................79-81 WIND LOAD CHARTS (FRONT or BACK) TF VG 451/451T (SSG Mullions) ...................................................82 WIND LOAD CHARTS (MULTI PLANE) TF VG 451 (Non-Thermal) ..............................................................83 TF VG 451T (Thermal) ....................................................................84 WIND LOAD CHARTS (ENTRANCE FRAMING) TF VG 451/451T .......................................................................85-86 DEADLOAD CHARTS TF VG 451/451T ........................................................................87-88 END REACTION CHARTS ................................................................89 THERMAL CHARTS EXAMPLE CALCULATION .............................................................90 TF VG 451 (CENTER – Non-Thermal) .....................................91-93 TF VG 451 Pre-Glazed (CENTER - Non-Thermal) ..................94-96 TF VG 451T (CENTER – Thermal) ...........................................97-99 TF VG 451T Pre-Glazed (CENTER – Thermal) ...................100-102 TF VG 451T (FRONT – Thermal) .........................................103-105 TF VG 451T (BACK – Thermal) ...........................................106-108 TF VG 451T with Steel (CENTER) ........................................109-111 kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 Trifab® VersaGlaze® 451/451T Framing System64 ADMC040EN APRIL, 2024 WIND LOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13' 6" and L/240 +1/4" above 13' 6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104 MPa), STEEL 30,000 psi (207 MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. If the end reaction of the mullion [mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two] is more than 500 lbs., the optional Heavyweight Compensating Receptor Face/Reinforcing Clip (Screw Spline/Shear Block systems) or Mullion Anchors (Stick system) must be used. Consult Application Engineering. (Mullion Anchor not used with Standard Receptor.) DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. NOTE: Charts are for THERMAL and NON-THERMAL members. WIND LOAD / DEADLOAD CHARTS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG001 451CG002 451CG012451CG002 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 1 2 4 3 2 4.5 3.5 2.5 1.5 0.5 1.5 ABCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 65 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (CENTER) Non-Thermal CHARTS Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 3.237 (134.73 x 104)S = 1.431 (23.45 x 103) I = 3.137 (130.57 x 104)S = 1.384 (22.68 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG112451CG002 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 66 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451CG013451CG002 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451CG112451CG002with 450110 STEEL WIND LOAD CHARTS (CENTER) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 5.907 (245.86 x 104)S = 2.615 (42.85 x 103) I = 3.346 (139.27 x 104) S = 1.474 (24.15 x 103) IA = 3.346 (139.27 x 104)SA = 1.474 (24.15 x 103) IS = 1.935 (80.54 x 104)SS = 0.938 (15.37 x 103) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG005A 451CG005 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 AB CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 67 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 451CG005Awith 450110 STEEL WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (CENTER) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 3.016 (125.53 x 104) S = 1.340 (21.96 x 103) IA = 3.016 (125.53 x 104)SA = 1.340 (21.96 x 103)IS = 1.935 (80.54 x 104) SS = 0.938 (15.37 x 103) I = 2.907 (120.99 x 104)S = 1.292 (21.17 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG001A451CG002 451CG010451CG540 451CG010A 451CG540 A BC DE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 68 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 HEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (CENTER) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 4.301 (179.02 x 104)S = 1.886 (30.91 x 103) I = 4.507 (187.59 x 104)S = 1.993 (32.66 x 103) I = 5.083 (211.57 x 104) S = 2.259 (37.02 x 103) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451CG081 / 451CG082 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 B C DE 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 BCD E 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 BC DE 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 BCDE 1.0 2.0 4.0 3.0 2.0 69 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 HEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (CENTER) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 4.829 (201.00 x 104)S = 2.146 (35.17 x 103) 451CG081 / 451CG082with 400110 STEEL WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TCG001 451TCG012 451TCG013 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 ABC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 70 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS (CENTER) Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TCG112 451TCG005 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 71 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 WIND LOAD CHARTS (CENTER) Thermal WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 451TCG112 with 450110 STEEL WITHOUT HORIZONTALSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WITHOUT HORIZONTALS WITHOUT HORIZONTALS Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TCG113 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 72 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 WIND LOAD CHARTS (CENTER) Thermal WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WITHOUT HORIZONTALSAllowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TCG001A 451TCG540451TCG010 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 73 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 WITHOUT HORIZONTALS 451TCG540 451TCG010A WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WIND LOAD CHARTS (CENTER) Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TCG081 / 451TCG082 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 B C D E 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 B CD E 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 B CD E 1.0 2.0 4.0 3.0 2.0 87654321 A 4 5 6 7 8 9 10 11 12 13 14 15 B CD E 1.0 2.0 4.0 3.0 2.0 74 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 HEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSAllowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) 451TCG081 / 451TCG082with 400110 STEEL WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS (CENTER) Thermal WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG012451VG026 451VG005 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 AB CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 75 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 WIND LOAD CHARTS (FRONT/BACK) Non-Thermal WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEET WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEET WITHOUT HORIZONTALS WIDTH IN METERSHEIGHT IN FEETHEIGHT IN METERSHEIGHT IN FEETHEIGHT IN METERSWIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451VG012451VG026with 1" x 2-1/4" STEEL BAR Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 3.346 (139.27 x 104)S = 1.447 (23.71 x 103) IA = 3.346 (139.27 x 104)SA = 1.447 (23.71 x 103) IS = 0.949 (39.50 x 104)SS = 0.844 (13.83 x 103) I = 3.001 (124.91 x 104)S = 1.323 (21.68 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG014 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C DE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 76 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 WIND LOAD CHARTS (FRONT/BACK) Non-Thermal WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSIA = 3.001 (124.91 x 104) SA = 1.323 (21.68 x 103) IS = 0.949 (39.50 x 104) SS = 0.844 (13.83 x 103) 451VG005with 1" x 2-1/4" STEEL BAR I = 5.604 (233.25 x 104)S = 2.397 (39.28 x 103) 451VG014with 1" x 2" STEEL BAR Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 5.604 (233.25 x 104)S = 2.397 (39.28 x 103) IS = 0.667 (27.26 x 104)SS = 0.667 (10.93 x 103) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG134 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C DE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C DE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 77 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 451VG134with 1" x 2-1/4" STEEL BAR 451VG010451VG540 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSI = 4.418 (183.89 x 104)S = 1.798 (29.46 x 103) I = 2.930 (121.96 x 104) S = 1.290 (21.13 x 103) WITHOUT HORIZONTALSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (FRONT/BACK) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) IA = 2.930 (121.96 x 104) SA = 1.290 (21.13 x 103) IS = 0.949 (39.50 x 104) SS = 0.844 (13.83 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG010A451VG009 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 78 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 WIND LOAD CHARTS (FRONT/BACK) Non-Thermal WITHOUT HORIZONTALSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSI = 5.076 (211.27 x 104)S = 2.066 (33.86 x 103) Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 ABCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 79 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 451TVG005 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451TVG012 451VG026 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 451TVG012451VG026with 1" x 2-1/4" STEEL BAR WIND LOAD CHARTS (FRONT/BACK) Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TVG134 451TVG014 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 ABCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 80 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 WIND LOAD CHARTS (FRONT/BACK) Thermal WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 451TVG134 with 1" x 2-1/4" STEEL BAR Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TVG540451TVG010 451TVG540 451TVG010A A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BC D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 81 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS (FRONT/BACK) Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451SSG005 A B CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 AB CDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 Trifab® VersaGlaze® 451/451T Framing System82 ADMC040EN APRIL, 2024 451SSG005with 1" x 2" STEEL BAR WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (FRONT/BACK) SSG Mullions Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) IA = 1.527 (63.55 x 104)SA = 1.057 (17.32 x 103) IS = 0.667 (27.76 x 104)SS = 0.667 (10.93 x 103) I = 1.527 (63.55 x 104) S = 1.057 (17.32 x 103) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451VG069451VG069 451VG052451CG028 451VG001451CG002 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B C D E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 83 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (MULTI-PLANE) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 3.470 (144.43 x 104)S = 1.431 (23.45 x 103) I = 3.362 (139.94 x 104)S = 1.181 (19.35 x 103) I = 3.485 (145.05 x 104)S = 1.468 (24.06 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 451TVG001 451TVG052 451TVG069451TVG069 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 ABCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCDE 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A B CD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 A BCD E 876543214 5 6 7 8 9 10 11 12 13 14 15 4 3 2 4.5 3.5 2.5 1.5 1 20.5 1.5 84 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITHOUT HORIZONTALS WITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-A8 AND AAMA 505 WIND LOAD CHARTS (MULTI-PLANE) Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 EDC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 ED CB A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E D C B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DCB A 451599451CG002 451064451CG002 451501 451019 451501 451019 Trifab® VersaGlaze® 451/451T Framing System 85 ADMC040EN APRIL, 2024 with 450110 STEEL WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIND LOAD CHARTS (ENTRANCES) Non-Thermal Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) IA = 3.116 (129.70 x 104)SA = 1.385 (22.70 x 103) IS = 1.935 (80.54 x 104)SS = 0.938 (15.37 x 103) I = 3.116 (129.7 x 104)S = 1.385 (22.7 x 103) I = 3.586 (149.26 x 104)S = 1.594 (26.12 x 103) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 ED C B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 E DC B A 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 345678 ED C B A 451064451CG002 451599451CG002 451VG019 Trifab® VersaGlaze® 451/451T Framing System86 ADMC040EN APRIL, 2024 WIND LOAD CHARTS (ENTRANCES) Non-Thermal WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451VG019with 1" x 2-1/4" STEEL BAR WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSwith 450110 STEEL Allowable Stress Design Load LRFD Ultimate Design Load A =15 PSF (720)25 PSF (1200) B =20 PSF (960)33 PSF (1580) C =25 PSF (1200)42 PSF (2000) D =30 PSF (1440)50 PSF (2400)E =40 PSF (1920)67 PSF (3200) I = 3.124 (130.03 x 104) S = 1.333 (21.84 x 103) I = 3.565 (148.39 x 104)S = 1.622 (26.58 x 103) IS = 1.935 (80.54 x 104)SS = 0.938 (15.37 x 103) IA = 3.124 (130.03 x 104) SA = 1.333 (21.84 x 103) IS = 0.949 (39.50 x 104) SS = 0.844 (13.83 x 103) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 CBA 0 1 1 2 3 .5 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 CBA0 1 1 2 3 .5 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 C B A 0 1 1 2 3 .5 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 C B A 0 1 1 2 3 .5 451TVG011 451VG111451VG011 451TVG111 451CG011A 451CG003451CG002451CG011 451TCG011 451TCG003451CG002 451CG003A451CG002 Trifab® VersaGlaze® 451/451T Framing System 87 ADMC040EN APRIL, 2024 A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSHorizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass supported on two setting blocks at the loading points shown. NOTE: Charts are for THERMAL and NON-THERMAL members. DEADLOAD CHARTS kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 CBA0 1 1 2 3 .5 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 C BA 0 1 1 2 3 .5 1 21.5 1.5 2.5 2 3 4 5 6 7 8 9 10 11 1 2 345678 CBA 0 1 1 2 3 .5 451TSSG111 451SSG111 Trifab® VersaGlaze® 451/451T Framing System88 ADMC040EN APRIL, 2024 DEADLOAD CHARTS A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass supported on two setting blocks at the loading points shown. NOTE: Charts are for THERMAL and NON-THERMAL members. Height limitations for transom glass over a doorway are based upon a 1/16" (1.6) maximum allowable deflection at the center of a transom bar.The accompanying charts are calculated for 1" (25.4) thick insulating glass supported on two setting blocks placed at the loading points shown. A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERS451081DOUBLE ACTING T-BAR 451502SINGLE ACTING T-BAR 450500TRAY kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 34567 8 E D C B A .5 0 1 2 3 .5 1 1 21.5 1.5 2 2.5 3 3.5 4 4 5 6 7 8 9 10 11 12 13 14 15 1 2 34567 8 E D C B A .5 0 1 2 3 .5 1 451VG006 451SSG006 451SSG106 451VG106 451TVG106 451TVG006 451TSSG006 451TSSG106 Trifab® VersaGlaze® 451/451T Framing System 89 ADMC040EN APRIL, 2024 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa)WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSWIDTH IN METERS WIDTH IN FEETHEIGHT IN FEETHEIGHT IN METERSFor each application, end reactions MUST be checked. These charts are used to verify that the end reactions at the head and sill receptors are500 lbs. (2224N) or less and will meet the specified wind load. 500lbs. Max. End Reaction END REACTION CHARTS kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 7' 0"9' 6"15' 8" 5' 0"2' 0"0.49 91%0.48 (2.73)0.46 (2.61)0.44 (2.50)0.42 (2.39)0.40 (2.27)0.38 (2.16)0.36 (2.05)0.34 (1.93)0.32 (1.82)0.30 (1.71)0.28 (1.59)0.26 (1.48)0.24 (1.37)0.22 (1.25)0.20 (1.14)7570858095900.80 (4.55) 0.75 (4.26) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.45 (2.56) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) Trifab® VersaGlaze® 451/451T Framing System90 ADMC040EN APRIL, 2024 Example Glass U-factor = 0.42 Btu/hr·ft2·oF Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15' 8" x 9' 6" = 148.83ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area Percent of Glass Based on 91% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.49 Btu/hr x ft2 x oF COG U-factor THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)System U-Factor (Btu/h·ft2·°F)(W/m²•°C)EXAMPLE (NOT FOR DESIGN) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.48 (2.73)0.46 (2.61)0.44 (2.50)0.42 (2.39)0.40 (2.27)0.38 (2.16)0.36 (2.05)0.34 (1.93)0.32 (1.82)0.30 (1.71)0.28 (1.59)0.26 (1.48)0.24 (1.37)0.22 (1.25)0.20 (1.14)7570858095900.80 (4.55) 0.75 (4.26) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.45 (2.56) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.90 (5.11) 0.85 (4.83) 91 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451 (CENTER – Non-Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507.System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Aluminum Glazing Spacer Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 750.90 0.85 70858095900.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 750.90 0.85 70858095900.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 92 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 THERMAL CHARTS Trifab® VersaGlaze® 451 (CENTER – Non-Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 93 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451 (CENTER – Non-Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.63 0.46 0.61 0.44 0.60 0.42 0.58 0.40 0.57 0.38 0.55 0.36 0.53 0.34 0.52 0.32 0.50 0.30 0.49 0.28 0.47 0.26 0.45 0.24 0.44 0.22 0.42 0.20 0.41 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.90 0.80 0.85 0.76 0.80 0.71 0.75 0.67 0.70 0.63 0.65 0.58 0.60 0.64 0.55 0.49 0.50 0.45 0.45 0.41 0.40 0.36 0.35 0.32 0.30 0.27 0.25 0.23 0.20 0.18 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.90 0.79 0.85 0.75 0.80 0.71 0.75 0.66 0.70 0.62 0.65 0.57 0.60 0.53 0.55 0.49 0.50 0.44 0.45 0.40 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.18 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 707580859095 0.20 (1.14) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.80 (4.55) 0.75 (4.26) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.85 (4.83) 0.90 (5.11) 0.95 (5.40) 94 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 Trifab® VersaGlaze® 451 Pre-Glazed (CENTER – Non-Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 95 ADMC040EN Trifab® VersaGlaze® 451 Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451 Pre-Glazed (CENTER – Non-Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 96 ADMC040EN Trifab® VersaGlaze® 451 Framing System APRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451 Pre-Glazed (CENTER – Non-Thermal) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.63 0.46 0.62 0.44 0.60 0.42 0.59 0.40 0.57 0.38 0.56 0.36 0.54 0.34 0.52 0.32 0.51 0.30 0.49 0.28 0.48 0.26 0.46 0.24 0.45 0.22 0.43 0.20 0.41 0.18 0.40 0.16 0.38 0.14 0.36 0.12 0.35 0.10 0.33 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.67 0.70 0.63 0.65 0.58 0.60 0.54 0.55 0.49 0.50 0.45 0.45 0.41 0.40 0.36 0.35 0.32 0.30 0.28 0.25 0.23 0.20 0.19 0.15 0.15 0.10 0.10 0.05 0.06 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.65 0.70 0.61 0.65 0.57 0.60 0.52 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.17 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.38 (2.16) 0.40 (2.27) 0.42 (2.39) 0.44 (2.50) 0.46 (2.61) 0.48 (2.73) 0.10 (0.57) 0.15 (0.85) 0.20 (1.14) 0.25 (1.42) 0.30 (1.70) 0.35 (1.99) 0.40 (2.27) 0.45 (2.56) 0.50 (2.84) 0.55 (3.12) 0.60 (3.41) 0.65 (3.69) 0.70 (3.97) 707580859095 97 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T (CENTER – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. Warm-Edge Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 98 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T (CENTER – Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Warm-Edge Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 99 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T (CENTER – Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.53 0.46 0.51 0.44 0.50 0.42 0.48 0.40 0.46 0.38 0.45 0.36 0.43 0.34 0.41 0.32 0.40 0.30 0.38 0.28 0.36 0.26 0.35 0.24 0.33 0.22 0.31 0.20 0.30 0.18 0.28 0.16 0.26 0.14 0.25 0.12 0.23 0.10 0.21 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.67 0.70 0.62 0.65 0.58 0.60 0.53 0.55 0.49 0.50 0.45 0.45 0.40 0.40 0.36 0.35 0.31 0.30 0.27 0.25 0.23 0.20 0.18 0.15 0.14 0.10 0.10 0.05 0.05 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.66 0.70 0.61 0.65 0.57 0.60 0.53 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.18 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Warm-Edge Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 707580859095 0.20 (1.14) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.15 (0.85) 100 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T (CENTER – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Aluminum Glazing Spacer Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 101 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T (CENTER – Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 102 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T (CENTER – Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.54 0.46 0.52 0.44 0.51 0.42 0.49 0.40 0.48 0.38 0.46 0.36 0.44 0.34 0.43 0.32 0.41 0.30 0.40 0.28 0.38 0.26 0.36 0.24 0.35 0.22 0.33 0.20 0.32 0.18 0.29 0.16 0.28 0.14 0.26 0.12 0.25 0.10 0.23 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.67 0.70 0.62 0.65 0.58 0.60 0.53 0.55 0.49 0.50 0.45 0.45 0.40 0.40 0.36 0.35 0.32 0.30 0.27 0.25 0.23 0.20 0.18 0.15 0.14 0.10 0.10 0.05 0.05 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.66 0.70 0.61 0.65 0.57 0.60 0.53 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.18 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 707580859095 0.20 (1.14) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.15 (0.85) 103 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T Pre-Glazed (CENTER – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Aluminum Glazing Spacer Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 104 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T Pre-Glazed (CENTER – Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 105 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T Pre-Glazed (CENTER – Thermal) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.55 0.46 0.53 0.44 0.51 0.42 0.50 0.40 0.48 0.38 0.47 0.36 0.45 0.34 0.43 0.32 0.42 0.30 0.40 0.28 0.39 0.26 0.37 0.24 0.35 0.22 0.34 0.20 0.32 0.18 0.30 0.16 0.28 0.14 0.27 0.12 0.25 0.10 0.24 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.66 0.70 0.62 0.65 0.58 0.60 0.53 0.55 0.49 0.50 0.45 0.45 0.40 0.40 0.36 0.35 0.31 0.30 0.27 0.25 0.23 0.20 0.18 0.15 0.14 0.10 0.10 0.05 0.05 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.65 0.70 0.61 0.65 0.57 0.60 0.52 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.17 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0. 48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.3 (1.93)4 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57)0.15 (0.85) 0.20 (1.14) 0.25 (1.42) 0.30 (1.70) 0.35 (1.99) 0.40 (2.27) 0.45 (2.56) 0.50 (2.84) 0.55 (3.12) 0.60 (3.41) 0.65 (3.69) 0.70 (3.97) 707580859095 106 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T (FRONT – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Warm-Edge Glazing Spacer Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 107 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Trifab® VersaGlaze® 451T (FRONT – Thermal) Warm-Edge Glazing Spacer Charts are generated per AAMA 507. Charts are generated per AAMA 507. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 108 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T (FRONT – Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.54 0.46 0.52 0.44 0.50 0.42 0.49 0.40 0.47 0.38 0.46 0.36 0.44 0.34 0.42 0.32 0.41 0.30 0.39 0.28 0.37 0.26 0.36 0.24 0.34 0.22 0.32 0.20 0.31 0.18 0.29 0.16 0.27 0.14 0.26 0.12 0.24 0.10 0.22 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.68 0.70 0.63 0.65 0.59 0.60 0.54 0.55 0.50 0.50 0.46 0.45 0.41 0.40 0.37 0.35 0.32 0.30 0.28 0.25 0.23 0.20 0.19 0.15 0.15 0.10 0.10 0.05 0.06 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.66 0.70 0.62 0.65 0.58 0.60 0.53 0.55 0.49 0.50 0.44 0.45 0.40 0.40 0.35 0.35 0.31 0.30 0.27 0.25 0.22 0.20 0.18 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Warm-Edge Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 707580859095 109 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T (FRONT – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)0.20 (1.14) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.15 (0.85) Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Aluminum Glazing Spacer 0.75 (4.27) Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 110 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 THERMAL CHARTS Trifab® VersaGlaze® 451T (FRONT – Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 111 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T (FRONT – Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.46 0.34 0.44 0.32 0.43 0.30 0.41 0.28 0.40 0.26 0.38 0.24 0.36 0.22 0.35 0.20 0.33 0.18 0.31 0.16 0.29 0.14 0.28 0.12 0.26 0.10 0.24 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.67 0.70 0.63 0.65 0.59 0.60 0.54 0.55 0.50 0.50 0.45 0.45 0.41 0.40 0.37 0.35 0.32 0.30 0.28 0.25 0.23 0.20 0.19 0.15 0.15 0.10 0.10 0.05 0.06 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.66 0.70 0.61 0.65 0.57 0.60 0.53 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.18 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 707580859095 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.15 (0.85) 0.20 (1.14) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 112 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T (BACK – Thermal) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS Aluminum Glazing Spacer System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 707580859095 113 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T (BACK – Thermal) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COG VT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 114 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T (BACK – Thermal)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.54 0.46 0.53 0.44 0.51 0.42 0.50 0.40 0.48 0.38 0.46 0.36 0.45 0.34 0.43 0.32 0.42 0.30 0.40 0.28 0.38 0.26 0.37 0.24 0.35 0.22 0.34 0.20 0.32 0.18 0.30 0.16 0.28 0.14 0.26 0.12 0.25 0.10 0.23 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.67 0.70 0.62 0.65 0.58 0.60 0.54 0.55 0.49 0.50 0.45 0.45 0.41 0.40 0.36 0.35 0.32 0.30 0.27 0.25 0.23 0.20 0.19 0.15 0.14 0.10 0.10 0.05 0.05 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.66 0.70 0.61 0.65 0.57 0.60 0.53 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.18 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.80 (4.55) 0.75 (4.26) 0.70 (3.97) 0.65 (3.69) 0.60 (3.41) 0.55 (3.12) 0.50 (2.84) 0.40 (2.27) 0.35 (1.99) 0.30 (1.70) 0.25 (1.42) 0.20 (1.14) 0.45 (2.56) 0.85 (4.83) 0.90 (5.11) 115 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 Trifab® VersaGlaze® 451T with Steel (CENTER) System U-factor vs Percent of Glass Area Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor THERMAL CHARTS System U-Factor (Btu/h·ft2·°F)(W/m²•°C)Aluminum Glazing Spacer Notes for System U-factor, SHGC, and VT charts: For glass values not listed, linear interpolation is permitted.Glass Properties are based on center of glass values and are obtained from your glass supplier. Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 116 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 Trifab® VersaGlaze® 451T with Steel (CENTER) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT THERMAL CHARTS Charts are generated per AAMA 507. Charts are generated per AAMA 507. Aluminum Glazing Spacer kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 117 ADMC040EN Trifab® VersaGlaze® 451T Framing SystemAPRIL, 2024 THERMAL PERFORMANCE MATRIX Trifab® VersaGlaze® 451T with Steel (CENTER)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.59 0.46 0.57 0.44 0.55 0.42 0.54 0.40 0.52 0.38 0.51 0.36 0.49 0.34 0.48 0.32 0.46 0.30 0.44 0.28 0.43 0.26 0.41 0.24 0.40 0.22 0.38 0.20 0.37 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.66 0.70 0.62 0.65 0.58 0.60 0.53 0.55 0.49 0.50 0.45 0.45 0.40 0.40 0.36 0.35 0.32 0.30 0.27 0.25 0.23 0.20 0.19 0.15 0.14 0.10 0.10 0.05 0.05 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.65 0.70 0.61 0.65 0.57 0.60 0.52 0.55 0.48 0.50 0.44 0.45 0.39 0.40 0.35 0.35 0.31 0.30 0.26 0.25 0.22 0.20 0.17 0.15 0.13 0.10 0.09 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4"). Aluminum Glazing Spacer kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.EC 97911-316 118 ADMC040EN Trifab® VersaGlaze® 451T Framing System APRIL, 2024 BLANK PAGE