Loading...
HomeMy WebLinkAboutADMA010EN - ENTRANCE SPECkawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.1 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 FEATURES For specific product applications, consult your Kawneer representative. Features • 190 narrow stile has 2-1/8" (54) vertical stile, 2-1/4" (57.2) top and 3-7/8" (98.4) bottom rail • 350 medium stile has 3-1/2" (88.9) vertical stile, 3-1/2" (88.9) top and 6-1/2" (165.1) bottom rail • 500 wide stile has 5" (127) vertical stile, 5" (127) top and 6-1/2" (165.1) bottom rail • Door is 1-3/4" (44.5) deep • Dual moment welded corner construction • Single or double acting • Infills range from 1/4" (6.4) to 1" (25.4) • Offset pivots, butt hinges, continuous geared hinge or center pivots • MS locks or panic hardware • Surface mounted or concealed closers • Architects Classic push/pulls • Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles • Polymeric bulb weatherstripping in door frames • Permanodic® anodized finishes option • Painted finishes in standard and custom choices Optional Features • Paneline® exit device or Paneline® MEL exit device • Wide variety of bottom rail and cross rail Product Applications • 190 narrow stile - engineered for moderate traffic in applications such as offices and stores • 350 medium stile - provides extra strength for schools, institutions and other high traffic applications • 500 wide stile - creates a monumental visual statement for banks, libraries or buildings that experience heavy traffic conditions kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.2 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.3 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 INDEX PICTORIAL VIEW ................................................................................5 DOOR TYPES/SECT. DIMENSIONS ...................................................6 CONSTRUCTION DETAILS .............................................................7,8 STANDARD ENTRANCE PACKAGES .......................................10, 11 ENTRANCE OFFERINGS ............................................................12, 13 APPLICATION CRITERIA ..................................................................13 PUSH PULL HARDWARE .................................................................14 PANELINE®/PANELINE® MEL EXIT DEVICE ..............................15, 16 AUTO SHOWROOM DOOR ........................................................17, 18 INTERMEDIATE RAILS .....................................................................19 INFILL OPTIONS ...............................................................................19 ACCESSORIES .................................................................................19 HANDICAP ACCESSIBLE ITEMS .....................................................20 BOTTOM RAILS ................................................................................21 THERMAL CHARTS ....................................................................22-40 Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.4 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 BLANK PAGE kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.5 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 PICTORIAL VIEW #1 MECHANICAL FASTENING is accomplished by attaching a 5/16" (7.9) thick extruded aluminum channel clip to the vertical stile with 1/4"-20 heat strengthened bolts and 3/16" thick steel nut plates for a high strength welding base for attachment horizontal member. #2 SIGMA* DEEP PENETRATION PLUG WELDS are made top and bottom after the horizontal is properly positioned over the channel clip to help provide the strongest door corner joint currently available. #3 SIGMA* FILLET WELDS along both top and bottom webs of the rail extrusion complete the welded corner construction. * An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG). DUAL MOMENT WELDED CORNER CONSTRUCTION kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.6 EC 97911-323 3 2 1 44-5/16"(1125.5)40-13/16"(1036.6)3 2 1 3 2 1 44-5/16"(1125.5)1686 = 40" (1016)1786 = 40" (1016)8600 = 41-11/16" (1058.9)8400 = 40-13/16" (1036.6)1690 = 40-5/8" (1031.9)1790 = 41-5/16" (1049.3)2-1/4"(57.2)17/32"(13.5)1-23/32 (43.8) 1 " 13-1/2"(88.9)15"(127.0)2 3-7/8"(98.4)2 6-1/2"(165.1)2 6-1/2"(165.1)31-3/4"(44.5)3 3 3 2-1/8"(54.0) 3 3-1/2"(88.9) 3 5"(127.0) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 DOOR TYPES/SECTION DIMENSIONS 190 NARROW STILE 350 MEDIUM STILE 500 WIDE STILE STANDARDLOCATIONS STANDARDLOCATIONS SINGLE ACTING SINGLE ACTING SINGLE ACTING DOUBLE ACTING DOUBLE ACTING DOUBLE ACTING TYPICAL TYPICALTOPATTACHMENT BOTTOMOF DOOR OF CYL. CL TOPATTACHMENT BOTTOMOF DOOR EXIT LOCKCYLINDER CL STANDARDEXIT DEVICE OF CRASH BAR FOR KAWNEER STANDARD EXIT DEVICECLTYPICALOF CRASH BAR FOR ADAMS RITECLOF CRASH BAR FOR FALCONCLAdditional information and CAD details are available at www.kawneer.com VARIES kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.7 EC 97911-323 1 3 450019 450019 2 1 3 450501 450501 2 4 5 450019 450019 4 5 450501 450501 6 7 8888 7 1144 66 225533 10 99 10 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 CONSTRUCTION DETAILS NOTE:1. SERIES 190 NARROW STILE DOORS ARE DETAILED, MEDIUM STILE 350 DOORS AND WIDE STILE 500 DOORS ALSO MAY BE USED. 2. TRIFAB® VERSAGLAZE® 450 CENTER, 1-3/4" X 4-1/2" (44.5 X 114.3) FRAMING IS DETAILED WITH THE DOORS FOR REFERENCE. OTHER KAWNEER FRAMING SERIES OR CURTAIN WALL SYSTEMS MAY BE USED. REFER TO THE CATALOG INDEX FOR THE APPROPRIATE DETAIL SECTION. 450033INSERT PAIR OF DOUBLE ACTING DOORS PAIR OF SINGLE ACTING DOORS DOUBLE ACTING DOOR SINGLE ACTING DOOR Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.8 EC 97911-323 069141069143 069143 8 10 7 9 450012 450081 450081 88 069139 069139 8 8 10 7 9 450012 450502 450502 069139 069139 8 8 10 7 9 041045041045 450079450079 450012 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 CONSTRUCTION DETAILS SINGLE ACTING DOORS DOUBLE ACTING DOORS COC WITH SINGLE ACTING OFFSET ARM OVERHEAD CLOSER FLOOR CLOSER OVERHEAD CLOSER 450022GLASS STOPS 450500TRAY 450500TRAY OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OPTIONALBOTTOM RAILWEATHERING OVERHEAD CLOSER OVERHEAD CLOSER 450022GLASS STOPS 450022GLASS STOPS OVERHEAD CLOSER OVERHEAD CLOSER Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.9 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 BLANK PAGE LEFT BLANK INTENTIONALLY kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.10 EC 97911-323 3/32"(2.4) 3/8"(9.5) 3/32" (2.4) 1/8" (3.2)1/8"(3.2)3/8"(9.5) 3/8" (9.5) 5/16" (7.9) 3/8" (9.5) 3/8"(9.5)3/8"(9.5) 1-3/4" (44.5) 1-3/4" (44.5) 3/32" (2.4)1/8"(3.2)190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 DIMENSIONS ARE NOMINAL MASONRY OPENING WIDTH (MOW) OVERALL FRAME WIDTH (OFW) DOOR OPENING WIDTH (DOW) MASONRY OPENING WIDTH (MOW) OVERALL FRAME WIDTH (OFW) DOOR OPENING WIDTH (DOW) CONTINUOUS HINGE JAMB SINGLE ACTING DOORS Additional information and CAD details are available at www.kawneer.com FRAME SIGHTLINE (FSL) MASONRY OPENING WIDTH (MOW) OVERALL FRAME WIDTH (OFW) TRANSOM JAMBS STANDARD ENTRANCE PACKAGES FRAME SIGHTLINE (FSL) STANDARD SIZES (TRIFAB® 400 & TRIFAB® VG 450 CENTER FRAMES) WITH AND WITHOUT TRANSOM Door Opening Dimension (DOW)Overall Frame Dimension (OFW)Masonry Opening Dimension (MOW) 3' 0"(914)3' 3-1/2"(1,003)3' 4-1/4"(1,022)3' 6"(1,067)3' 9-1/2"(1,156)3' 10-1/4"(1,175) 6' 0"(1,829)6' 3-3/4"(1,924)6' 4-1/4"(1,937) STANDARD SIZES (TRIFAB® VG 451 CENTER FRAMES) WITH AND WITHOUT TRANSOM Door Opening Dimension (DOW)Overall Frame Dimension (OFW)Masonry Opening Dimension (MOW) 3' 0"(914)3' 4"(1,016)3' 4-3/4"(1,035) 3' 6"(1,067)3' 10"(1,168)3' 10-3/4"(1,187)6' 0"(1,829)6' 4"(1,930)6' 4-3/4"(1,949)WITH AND WITHOUT TRANSOM OFW = DOW + 2 FSL MOW = OFW + 3/4" Note: Dimensions shown above reflect A1 Price Book standard stock door frame height with transom at 10' 3-1/2" (3,137). Trifab® VersaGlaze® 450 center door frames shown, Trifab® VersaGlaze® 451 center door frames similar. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.11 EC 97911-323 1/8"(3.2)1-3/4"(44.5)1/8"(3.2)3/8"(9.5)3/8"(9.5)1/2"(12.7)3/16"(4.3)190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 STANDARD SIZES (TRIFAB® 400 & TRIFAB® VG 450 CENTER FRAMES)WITHOUT TRANSOM Door Opening Dimension (DOH)Overall Frame Dimension (OFH)Masonry Opening Dimension (MOH) 7' 0"(2,134)7' 1-3/4"(2,178)7' 2-1/8"(2,188) 7' 0"(2,134)7' 1-3/4"(2,178)7' 2-1/8"(2,188) 7' 0"(2,134)7' 1-3/4"(2,178)7' 2-1/8"(2,188) STANDARD SIZES (TRIFAB® VG 451 CENTER FRAMES)WITHOUT TRANSOMDoor Opening Dimension (DOH)Overall Frame Dimension (OFH)Masonry Opening Dimension (MOH) 7' 0"(2,134)7' 2"(2,184)7' 2-3/8"(2,194) 7' 0"(2,134)7' 2"(2,184)7' 2-3/8"(2,194) 7' 0"(2,134)7' 2"(2,184)7' 2-3/8"(2,194) WITHOUT TRANSOM OFH = DOH + FSLMOH = OFH + 3/8"WITH TRANSOM OFH = DOH +TH MOH = OFH + 3/8" Note: Dimensions shown above reflect A1 Price Book standard stock door frame height with transom at 10' 3-1/2" (3,137). STANDARD ENTRANCE PACKAGES MASONRY OPENING HEIGHT (MOH)OVERALL FRAME HEIGHT (OFH)DOOR OPENING HEIGHT (DOH)450022GLASS STOPS Additional information and CAD details are available at www.kawneer.com MASONRY OPENING HEIGHT (MOH)OVERALL FRAME HEIGHT (OFH)DOOR OPENING HEIGHT (DOH)TRANSOM HEIGHT (TH)FRAME SIGHTLINE (FSL) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.12 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 ENTRANCE OFFERINGS STANDARD OPTIONAL Doors Narrow stile 190 doors prepared for attachment hardware.Medium stile 350 or wide stile 500. Door Sizes Std.Standard sizes shown on pages 10 and 11.Any size up to 4' 0" x 8' 0" (1,219 x 2,438). Glass Stops Beveled glass stops for 1/4" (6.4) or 3/16" (4.0) infill.Square glass stops for 3/16" (4.0) or 1/4" (6.4) infill.Also 1" (25.4) stops. Door Frames Trifab® 400 - 1-3/4" x 4" (44.5 x 101.6) for single glazing.Trifab® VG 450 Center - 1-3/4" x 4-1/2" (44.5 x 114.3) for single glazing or Trifab® VG 451 Center - 2" x 4-1/2" (50.8 x 114.3) for double glazing. Any Kawneer framing system suitable for door frames may be selected, but manufactured per order. Push-Pulls Single Acting:Architects Classic Hardware CO-9 Pull and CP-II Push Bar. Architects Classic Hardware CO-9 Pull and CP Push Bar. Single Acting:Architects Classic Hardware CO-12 and CP-II push bar. Architects Classic Hardware CO-12 and CP push bar. Architects Classic Hardware CO-9/CO-9 Pulls. Architects Classic Hardware CO-12/CO-12 Pulls. Double Acting:Architects Classic Hardware CP Push Bars.Double Acting:Architects Classic Hardware CO-9/CO-9 Pulls. Architects Classic Hardware CO-12/CO-12 Pulls. Door Closers Single Acting:Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check and with or without adjustable hold-open. Standard concealed overhead closer with single acting offset arm. Single Acting:LCN 4040 surface closer with or without adjustable hold-open. LCN 2030 or 5010 concealed overhead closers with or without hold-open. LCN 1260 adjustable surface closer. Norton 8100 surface closer with a 50% spring power adjustment (for opening forces of less than 8 pounds). Closer is available with standard back-checks and with or without the hold-open feature. International single acting concealed overhead closer. Falcon SC 60 Surface closer. Double Acting:Standard concealed overhead closer with 90 degree or 105 degree hold-open or without hold open. For heavy traffic & high wind applications, a supplemental door stop is recommended. Double Acting:International overhead concealed closer. Hinging Single Acting:Kawneer top and bottom offset pivots (or) Kawneer top and bottom 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP) (or) Kawneer continuous gear hinge. Double Acting:Kawneer bottom center pivots for use with concealed overhead closer.Double Acting:Kawneer top center (walking beam) pivot for use with floor closers. Intermediate Pivots/Butts Single Acting:Kawneer intermediate offset pivot (or) Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP). Single Acting:Rixson M-19 or IVES #7215-INT intermediate offset pivot. Power Transfers Single Acting:Kawneer EL intermediate offset pivot (or) Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with wire transfer (or) EPT (Electric Power Transfer). Power Supply SP-1000X Power Supply: For use with Paneline® EL exit devices. For use with Falcon EL 1690 and EL 1790 exit devices. SP-2000 Power Supply: For use with Paneline® MEL exit devices. NP1 Power Supply: For use with Kawneer 1686 MEL and 1786 MEL exit devices only. Locks -Active Leaf Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders.Adams-Rite #4510 latch lock.Adams-Rite #1850A-500 short throw deadlock.Adams-Rite #1850A-505 hookbolt lock.Adams-Rite #4015 two-point Lock.Adams-Rite #4085 three-point Lock.Adams-Rite #4089 exit indicator.Kawneer cylinder guard.Kawneer thumbturn (in lieu of cylinder). kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.13 EC 97911-323 3.5 3 3 4 2 2 2.5 7 8 9 10 11 5 5 1 1 1.5 A B 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 APPLICATION CRITERIA As indicated on Page 10, the standard sizes of swing doors are 3' 0" x 7' 0" (914.4 x 2,133.6) or 3' 6" x 7' 0" (1,067 x 2,134) for single doors and6' 0" x 7' 0" (1,828.8 x 2,133.6) for pairs of doors. When these sizes are exceeded the following criteria should be administered. 1. Larger doors should not be subject to heavy traffic or strong prevailing wind conditions. 2. Larger doors should use a door closer with a good back check action. 3. When a 190 door exceeds 9' 0" (2,743) or a 350/500 door exceeds 10' 0" (3048) in height, a cross rail or push bar should be used to reinforce the vertical stiles. 4. When an offset hung door exceeds 7' 6" (2,286.0) in height, an intermediate butt or offset pivot should be used. 5. Tall doors should be prevented from racking by proper utilization of hardware, including door closers, door holders and door stops. NOTE: CONTACT YOUR FACTORY REPRESENTATIVE FOR APPLICATION ASSISTANCE. ENTRANCE OFFERINGS/APPLICATION CRITERIA A = NARROW STILE 190 B = MEDIUM STILE 350 OR WIDE STILE 500 MAXIMUM DOOR HEIGHTFOR PANELINE® MEL = 8' 0" FEETFEETMETERS METERSMAXIMUM SIZE DOOR LEAFSGLAZED WITH 1/4" (6.4) GLASS STANDARD OPTIONAL Locks - Inactive Leaf One pair of Kawneer flush bolts in the inactive leaf of a pair of doors. Controller® is a 3-point locking system consisting of a two point locking device in the inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock in the active leaf. This combination provides for greater security than possible with flush bolts and complies with the life safety considerations of building codes which prohibit the use of flush bolts. Thresholds A 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold.A 1/2" x 6-3/4" (12.7 x 171.5) aluminum mill finish threshold. Weathering Single Acting:Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. (The system is complete with an optional EPDM blade gasket sweep strip applied to the bottom door rail with concealed fasteners). Bottom Door Sweep Double Acting:Pile cloth weathering in the door and frame. Exit Device Kawneer 1686 Concealed Rod Exit Device with or without a mortised type cylinder. Kawneer 1786 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Pairs of doors require a Kawneer RM-86 removable mullion. Paneline® exit device is a concealed rod exit device applicable to single or pairs of doors. It features an activating panel contained within the door cross rail. Kawneer 1686 MEL Concealed Rod Exit Device electric modification is available. Kawneer 1786 MEL Rim Exit Device electric modification is available. Kawneer 1686 CD Concealed Rod Exit Device available with cylinder dogging. Kawneer 1786 CD Rim Exit Device available with cylinder dogging. Kawneer 1686 Lever Handle is available for the Kawneer 1686 concealed rod exit device. Kawneer 1786 Lever Handle is available for the Kawneer 1786 rim type exit device. Falcon 1690 Concealed Rod Exit Device with or without a mortised type cylinder. Falcon 1790 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Falcon EL 1690 electric modification is also available. Falcon EL 1790 electric modification is also available Paneline® MEL electric modification is also available. Falcon 1990 is a concealed rod exit device with or without a rim type cylinder. Falcon 2090 is a rim type exit device with or without a rim type cylinder. Pairs of doors require a removable aluminum mullion. RM-70 with the Falcon 2090 exit device. Exit Device Pulls:Architects Classic CO-9 Pull with Kawneer 1686 and 1786 exit devices. Architects Classic CPN Pull for Paneline® and Paneline® MEL exit devices. Optional Exit Device Pulls:Architects Classic CO-12 Pull with Kawneer 1686 and 1786 exit devices. kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.14 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 EXIT DEVICES AND PULLSEXIT DEVICES KAWNEER PANELINE® / PANELINE® MEL CPN PULL ONEXTERIOR OF DOOR SEE PAGE 15 AND 16 FOR COMPLETE PANELINE® INFORMATION CONCEALED RODFalcon 1990RIM LATCHFalcon 2090CO-9 PULL CO-12 PULL CONCEALED RODFalcon 1690Falcon EL 1690 RIM LATCHFalcon 1790Falcon EL 1790 CONCEALED RODKawneer 1686Kawneer 1686 MEL Kawneer 1686 CD RIM LATCHKawneer 1786Kawneer 1786 MEL Kawneer 1786 CD PUSH-PULL HARDWARE ARCHITECTS CLASSIC (PUSH PULL SETS) SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR AS STANDARDDOUBLE ACTING DOORS USE CP PUSH BARS BACK TO BACK AS STANDARD. REFER TO HARDWARE SECTION FOR COMPLETE HARDWARE INFORMATION. * CP-II PUSH BAR IS NOT TO BE USED FOR BACK TO BACK MOUNTING ON D/A DOORS. CP-II* PUSH BAR CP PUSH BARCO-9 PULL CO-12 PULL CO-9/CP-IICO-12 /CP-IICO-9/CPCO-12/CP CP-II/CP-II* CP/CP CO-9/CO-9CO-12/CO-12 ARCHITECTS CLASSIC (COMPONENTS) EXTERIOR VIEW OF 190 DOOR (350/500 SIMILAR) CPN PULL AND OPTIONAL CYLINDER GUARD SHOWN.OVERALL W/ STOPSLEVER HANDLEKawneer 1686Kawneer 1786 kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.15 EC 97911-323 PUSH PUSH PUSH 6-1/8"(155.6) 5-7/8" (149.2) 5-7/8"(149.2)8-1/4"(209.6)36-1/8"(917.6) 17/32" (13.5)7-1/8"(181.0)1-23/32" (43.8) 1-3/8" (34.9)17/32"(13.5)PUSH PUSH 12 3* 1 2 3* 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 ACTIVE DOOR SIDELITE *VESTIBULE DOOR(Without Exit Device or Lock)CROSSRAILWITH EXIT DEVICEAND CPN PULL HANDLE SIDELITECROSSRAIL CROSSRAILWITH FIXEDPANEL TO BOTTOM OF DOOR SEENOTE SEENOTE The Paneline® concealed rod exit device for 190, 350 and 500 doors will accommodate variations in stile width and door width as shown in the following illustrations. Sidelites adjacent to Paneline® equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the Paneline® cross rail. The Optional Paneline® MEL device is designed for electrified access control and is compatible with most key pad and card reader systems. See Hardware Section for complete description of Paneline® hardware, including finish of units. Paneline® uses mortise cylinder in lieu of the normal rim-type.Dummy Paneline® units are not for use with any type of lock. INTERIOR ELEVATIONSNOTE: Sidelites must be stop glazed above and below rail. PANELINE® MEL COMPONENTS POWER TRANSFERINTERMEDIATE BUTT HINGE POWER TRANSFERINTERMEDIATE OFFSET PIVOT ELECTRIC POWER TRANSFER(EPT)SP-2000 POWER SUPPLY LOCK STILE TRIM FILLER WIDTHVARIES WITH STILE WIDTH DOGGING LOCK(TYPICAL) 190 DOOR DOOR OPENING WIDTH4' 0" (1,219.2) MAX. - 2' 9-9/32" (845.3) MIN. 3' 0" (914.6) ADA MIN. PIVOT STILE TRIM FILLER WIDTHVARIES WITH DOOR WIDTH 350 DOOR DOOR OPENING WIDTH4' 0" (1,219.2) MAX. - 2' 10-13/32" (873.9) MIN. 3' 0" (914.6) ADA MIN. 500 DOOR DOOR OPENING WIDTH4' 0" (1,219.2) MAX. - 2' 11-29/32" (912.0) MIN. 3' 0" (914.6) ADA MIN. PANELINE® / PANELINE® MEL EXIT DEVICE kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.16 EC 97911-323 21 or 3*1 or 3* PUSH PUSH PUSH PUSH PUSH PUSH PUSH PUSH 8-1/4"(209.6)36-1/8"(917.6) 17/32" (13.5)7-1/8"(181.0)1-23/32" (43.8)1-3/8" (34.9)17/32"(13.5)1 2 3* 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 PANELINE® EXIT DEVICE Sidelites adjacent to Paneline® equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the Paneline® cross rail. See Hardware Section for complete description of Paneline® hardware, including finish of units. Paneline® uses mortise cylinder in lieu of the normal rim-type.Dummy Paneline® units should not use any type of lock. INTERIOR ELEVATIONNOTE: Sidelites must be stop glazed above and below rail. * ALTERNATE CROSSRAIL FOR VESTIBULE DOORS (Without Exit Device or Lock) CROSS RAILWITH EXIT DEVICEAND PULL SIDELITECROSS RAIL CROSS RAILWITHFIXED PANEL TO BTMOF DOOR(FIXED LOCATION) SEE NOTE SEE NOTE INACTIVE DOOR ACTIVE DOOR SIDELITE EXTERIOR VIEW OF 190 DOOR (350-500 SIMILAR)WITH CPN PULL AND STANDARD CYLINDER GUARD SHOWN CPN PULL ONEXTERIOR OF DOOR LOCK STILE TRIM FILLER WIDTHVARIES WITH STILE WIDTH DOGGING LOCK(TYPICAL) 190 DOOR DOOR OPENING WIDTH8' 0" (2438.4) MAX. - 5' 7-1/4" (1,708.2) MIN. 6' 0" (1,828.8) ADA MIN. PIVOT STILE TRIM FILLER WIDTHVARIES WITH DOOR WIDTH 350 DOOR DOOR OPENING WIDTH 8' 0" (2,438.4) MAX. - 5' 9-5/16" (1,761.0) MIN. 6' 0" (1,828.8) ADA MIN. 500 DOOR DOOR OPENING WIDTH 8' 0" (2,438.4) MAX. - 6' 0" (1,828.8) MIN. 6' 0" (1,828.8) ADA MIN. kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.17 EC 97911-323 10' 3-1/2" (3,136.9)7' 0" (2,133.6)3' 6"x7' 0" 8' 0" (2,438.4)7' 0" (2,133.6)10' 3-1/2" (3,136.9)4' 6"x7' 0"3' 0"x7' 0"3' 0"x7' 0"3' 0"x7' 0" 9' 0" (2,734.2) 8' 3-1/2" (2,527.3)9' 3-1/2" (2,832.1) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 MAXIMUM ALLOWABLE SIZES• DOOR OPENING WIDTH TO 9' 0" (2,743.2) [SWING] OR 10' 0" (3,048) [BI-FOLD]• DOOR OPENING HEIGHT TO 8' 0" (2,438.4)• OVERALL FRAME HEIGHT TO 8' 1-3/4" (2,482.9) W/O TRANSOM• OVERALL FRAME HEIGHT TO 12' 0" (3,657.6) WITH TRANSOM NOTE: 1/4" GLAZING INFILL ONLY SWING TYPE BIFOLD TYPE AUTO SHOWROOM DOOR AUTO SHOWROOM PACKAGE DOORS ..........................190 NARROW STILE, 350 MEDIUM STILE AND 500 WIDE STILE DOORS. FRAME ...........................TRIFAB® VERSAGLAZE® 450 CENTER. CLOSER .........................NORTON 1601 ADJUSTABLE OR 1601 BF ADJUSTABLE SURFACE CLOSER (ACTIVE LEAF ONLY). BUTT HINGES ...............ONE PAIR 4-1/2" x 4" (114.3 x 101.6) BALL BEARING BUTTS ON ACTIVE LEAF, ONE AND ONE HALF PAIR ON INACTIVE LEAVES AT HINGE JAMB. CONTINUOUS HINGE ON INACTIVE LEAVES. LOCKS ...........................ADAMS-RITE MS1850A WITH (2) CYLINDERS ON ACTIVE LEAF. FLUSHBOLTS ................ONE PAIR EDGE MOUNTED FOR INACTIVE LEAVES (FACE MOUNTED ON #2 INACTIVE LEAF OF BIFOLD TYPE). THRESHOLD .................1/2" x 4" (12.7 x 101.6) ALUMINUM. RISER BLOCK ...............EXTRUDED ALUMINUM BLOCK APPLIED TO BOTTOM RAIL OF EACH INACTIVE LEAF. OPTIONAL CASTER .....IN LIEU OF RISER BLOCK, FACE APPLIED CASTER TO LEADING STILE OF INACTIVE LEAF. FRAME WIDTH FRAME WIDTH DOOR OPENING DOOR OPENINGDOOR OPENINGDOOR OPENINGFRAME HEIGHTFRAME HEIGHT kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.18 EC 97911-323 450501 450501 450501 450501 450501 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 AUTO SHOWROOM DOOR OVERALL FRAME DOOR OPENING SWING TYPE OVERALL FRAME DOOR OPENING BIFOLD TYPE OPTIONALCONTINUOUS HINGEJAMB Additional information and CAD details are available at www.kawneer.com kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.19 EC 97911-323 200059 200058 200057 200056 200055 1/2" (12.7)1"(25.4)1/2" (12.7)11/16"(42.9)1"(25.4) 2000531-3/8"(34.9)200054 200039 with 24923510"(254)069139 069143 039345 * 069141 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THRESHOLDS INFILL OPTIONS ACCESSORY ITEMS APPLICATION FOR SINGLE ACTING DOOR FOR CENTER HUNGCONCEALED CLOSER *SOME BUILDING CODES LIMIT THRESHOLD HEIGHT TO 1/2” (12.7) MAX. APPLIED STOP FOR SINGLE ACTING DOOR OPTIONALBOTTOM RAILWEATHERING 069177APPLIEDDOORSTOP 038365FINGERPROTECTOR 069154APPLIEDDOORSTOP HORIZONTAL / VERTICAL CROSS RAILS INTERMEDIATE RAILS, INFILL OPTIONS AND ACCESSORIES 3/16" (4.3) & 1/4" (6.4) INFILL OPTIONAL STANDARD 5/16" (7.9) & 3/8" (9.5)7/16" (11.1) & 1/2" (12.7)9/16" (14.3) & 5/8" (15.9)11/16" (17.5) & 3/4" (19.0)15/16" (23.8) & 1" (25.4) BEVEL GLASS STOPS SQUARE GLASS STOPS FOR CENTER HUNGFLOOR CLOSERS CROSS RAIL (Optional) Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.20 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 HANDICAP ACCESSIBLE ITEMS Note: The symbol of access is an adhesive backed decal applied to the surface of the optional cross rail. Letters and symbols on plastic pushshield are engraved and filled with white epoxy enamel. Description Architects Classic CO-12 Pull BF3 Push Shield with symbol Application Door with or withoutexit device Door cross rail(omit w/exit device) Length/Size 12" OC Pull attachment 15-7/8" x 7-7/8" (403.2 x 200.0)1/8" (3.2) Thick Height Location 44-5/16" from Top Mounting Holeto Btm. of Door Total Projection 3-1/4" (82.6)1/8" (3.2) See Hardware SectionMaterial / Finish Black PlasticPebble Finish PUSH-PULLS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.21 EC 97911-323 3-7/8"(98.5)6-1/2"(165.1)6-1/2"(165.1)190 350 500 10"(254.0)12"(304.8)16"(406.4)OR7 1/2"(184.2)10"(254.0)12"(304.8)190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 BOTTOM RAILS NOTE:See Page 19 for availableHorizontal Intermediate Members. OPTIONAL BOTTOM RAILS Rail heights shown may be used on 190, 350, and 500 doors. Custom heights available. STANDARD BOTTOM RAILSRail heights shown may be used on 190, 350, and 500 doors. Additional information and CAD details are available at www.kawneer.com kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.22 EC 97911-323 0.46 72%0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20 0.70 0.80 0.60 0.50 0.40 0.30 0.20 85 80 75 70 65 60 0.75 0.65 0.55 0.45 0.35 0.25 (2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14) 0.90 0.85 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F Total Daylight Opening = 31.562" x 77.062" = 16.89 ft2 Total Projected Area = 3' 3-1/2 x 7' 1-3/4" = 23.52 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (16.89 ÷ 23.52)100 = 72% System U-factor vs Percent of Glass Area EXAMPLENOT FOR DESIGNCOGU-factor Percent of Glass Area Based on 72% glass and center of glass (COG) U-factor of 0.28 System U-factor is equal to 0.46 Btu/hr • ft2 • °F Btuhr • ft2 • °FSystem U-factorGeneric Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 31.562" (801.7)(D.L.O.) 3' 3-1/2" (1,003.3)(F.W.)7' 1-3/4" (2,178.1)(F.H.)77.062" (1,957.4)(D.L.O.) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.23 EC 97911-323 0.48 (2.73)0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 190 (SINGLE DOOR) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.24 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 190 (SINGLE DOOR) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.25 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 190 (SINGLE DOOR)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.78 0.46 0.77 0.44 0.76 0.42 0.75 0.40 0.74 0.38 0.73 0.36 0.72 0.34 0.71 0.32 0.70 0.30 0.69 0.28 0.68 0.26 0.67 0.24 0.66 0.22 0.65 0.20 0.65 0.18 0.63 0.16 0.61 0.14 0.60 0.12 0.59 0.10 0.58 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.48 0.70 0.45 0.65 0.42 0.60 0.39 0.55 0.36 0.50 0.33 0.45 0.30 0.40 0.27 0.35 0.24 0.30 0.21 0.25 0.18 0.20 0.15 0.15 0.13 0.10 0.10 0.05 0.07 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.44 0.70 0.41 0.65 0.38 0.60 0.35 0.55 0.32 0.50 0.29 0.45 0.26 0.40 0.23 0.35 0.21 0.30 0.18 0.25 0.15 0.20 0.12 0.15 0.09 0.10 0.06 0.05 0.03 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960 mm wide by 2,090 mm high (37-3/4" by 82-3/8"). kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.26 EC 97911-323 0.47 (2.67)0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 190 (PAIR OF DOORS) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.27 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 190 (PAIR OF DOORS) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.28 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 190 (PAIR OF DOORS)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.47 0.73 0.46 0.72 0.44 0.71 0.42 0.70 0.40 0.69 0.38 0.68 0.36 0.67 0.34 0.66 0.32 0.64 0.30 0.63 0.28 0.62 0.26 0.61 0.24 0.60 0.22 0.59 0.20 0.58 0.18 0.56 0.16 0.55 0.14 0.54 0.12 0.53 0.10 0.52 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.50 0.70 0.47 0.65 0.44 0.60 0.41 0.55 0.38 0.50 0.35 0.45 0.31 0.40 0.28 0.35 0.25 0.30 0.22 0.25 0.19 0.20 0.16 0.15 0.13 0.10 0.09 0.05 0.06 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.47 0.70 0.44 0.65 0.41 0.60 0.38 0.55 0.35 0.50 0.31 0.45 0.28 0.40 0.25 0.35 0.22 0.30 0.19 0.25 0.16 0.20 0.13 0.15 0.09 0.10 0.06 0.05 0.03 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1,920 mm wide by 2,090 mm high (75-1/2" by 82-3/8"). kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.29 EC 97911-323 0.48 (2.73)0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 350 (SINGLE DOOR) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.30 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 350 (SINGLE DOOR) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.31 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 350 (SINGLE DOOR)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.83 0.46 0.82 0.44 0.81 0.42 0.81 0.40 0.80 0.38 0.79 0.36 0.78 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.69 0.16 0.68 0.14 0.68 0.12 0.67 0.10 0.66 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.43 0.70 0.41 0.65 0.38 0.60 0.36 0.55 0.33 0.50 0.30 0.45 0.28 0.40 0.25 0.35 0.23 0.30 0.20 0.25 0.17 0.20 0.15 0.15 0.12 0.10 0.10 0.05 0.07 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.39 0.70 0.36 0.65 0.34 0.60 0.31 0.55 0.29 0.50 0.26 0.45 0.23 0.40 0.21 0.35 0.18 0.30 0.16 0.25 0.13 0.20 0.10 0.15 0.08 0.10 0.05 0.05 0.03 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960 mm wide by 2,090 mm high (37-3/4" by 82-3/8"). kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.32 EC 97911-323 0.47 (2.67)0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 350 (PAIR OF DOORS) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.33 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 350 (PAIR OF DOORS) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.34 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 350 (PAIR OF DOORS)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.47 0.79 0.46 0.78 0.44 0.77 0.42 0.76 0.40 0.75 0.38 0.74 0.36 0.73 0.34 0.72 0.32 0.71 0.30 0.70 0.28 0.69 0.26 0.68 0.24 0.67 0.22 0.66 0.20 0.65 0.18 0.64 0.16 0.63 0.14 062 0.12 0.61 0.10 0.60 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.46 0.70 0.43 0.65 0.40 0.60 0.37 0.55 0.35 0.50 0.32 0.45 0.29 0.40 0.26 0.35 0.23 0.30 0.21 0.25 0.18 0.20 0.15 0.15 0.12 0.10 0.09 0.05 0.07 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.42 0.70 0.39 0.65 0.36 0.60 0.34 0.55 0.31 0.50 0.28 0.45 0.25 0.40 0.22 0.35 0.20 0.30 0.17 0.25 0.14 0.20 0.11 0.15 0.08 0.10 0.06 0.05 0.03 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1,920 mm wide by 2,090 mm high (75-1/2" by 82-3/8"). kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.35 EC 97911-323 0.48 (2.73) 0.46 (2.61)0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 500 (SINGLE DOOR) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.36 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 500 (SINGLE DOOR) kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.37 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 500 (SINGLE DOOR)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.48 0.87 0.46 0.86 0.44 0.85 0.42 0.84 0.40 0.84 0.38 0.83 0.36 0.82 0.34 0.81 0.32 0.81 0.30 0.80 0.28 0.79 0.26 0.78 0.24 0.77 0.22 0.77 0.20 0.76 0.18 0.75 0.16 0.74 0.14 0.73 0.12 0.73 0.10 0.72 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.38 0.70 0.36 0.65 0.34 0.60 0.32 0.55 0.29 0.50 0.27 0.45 0.25 0.40 0.23 0.35 0.21 0.30 0.18 0.25 0.16 0.20 0.14 0.15 0.12 0.10 0.09 0.05 0.07 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.33 0.70 0.31 0.65 0.29 0.60 0.27 0.55 0.25 0.50 0.22 0.45 0.20 0.40 0.18 0.35 0.16 0.30 0.13 0.25 0.11 0.20 0.09 0.15 0.07 0.10 0.04 0.05 0.02 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960 mm wide by 2,090 mm high (37-3/4" by 82-3/8"). kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.38 EC 97911-323 0.47 (2.67)0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 500 (PAIR OF DOORS) System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF)Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) COGU-factor Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. THERMAL CHARTS kawneer.comKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.39 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System SHGCVision Area / Total Area (%) COGSHGC System Visible Transmittance (VT) vs Percent of Vision Area System VTVision Area / Total Area (%) COGVT 500 (PAIR OF DOORS) kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2015, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.40 EC 97911-323 190/350/500 Standard Entrances ADMA010EN AUGUST, 2024 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 500 (PAIR OF DOORS)Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 Overall U-Factor 4 0.47 0.82 0.46 0.82 0.44 0.81 0.42 0.80 0.40 0.79 0.38 0.78 0.36 0.77 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.70 0.16 0.69 0.14 0.68 0.12 0.67 0.10 0.66 SHGC Matrix 2 Glass SHGC 3 Overall SHGC 4 0.75 0.41 0.70 0.38 0.65 0.36 0.60 0.34 0.55 0.31 0.50 0.29 0.45 0.26 0.40 0.24 0.35 0.21 0.30 0.19 0.25 0.17 0.20 0.14 0.15 0.12 0.10 0.09 0.05 0.07 Visible Transmittance 2 Glass VT 3 Overall VT 4 0.75 0.36 0.70 0.34 0.65 0.32 0.60 0.29 0.55 0.27 0.50 0.24 0.45 0.22 0.40 0.19 0.35 0.17 0.30 0.15 0.25 0.12 0.20 0.10 0.15 0.07 0.10 0.05 0.05 0.02 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1,920 mm wide by 2,090 mm high (75-1/2" by 82-3/8").