HomeMy WebLinkAbout019 E.1 - Electrical - Main Floor - Cottage Ac
Date:mobile #:phone #:Project No.Drawn by:Date:Scale:GENERAL CONTRACTOR:Revised by:
Drafting & Design, IncEG CONSTRUCTION, LLCEUGEN GRAFPO BOX 10906BOZEMAN, MT 59714406-579-8248B24-0328-5Blackmore Cottages - ABON TON AVE.BOZEMAN, MONTANABLACKMORE COTTAGECO. LLC-Allison Subdivision-Master Copy
D. Johnston 15 Oct 21
D. Johnston 20 Apr 24
D. Johnston 24 Aug 21
D. Johnston 25 Aug 21
D. Johnston 04 May 24IMPACTDRAFTING & DESIGN, incwww.impactdrafting.com2024 Brentwood Professional Center1195 Stoneridge Dr., Suite 3DBozeman, MT. 59718406-522-5382All rights reserved. All designs, drawings, ideas,
and written material contained or described herein
are the sole property of IMPACT Drafting & Design
Inc. and as such may not be altered, duplicated,
used or disclosed without written consent from
IMPACT Drafting & Design Inc.scale is correct ifprinted on D-Size paperby IMPACT DraftingNote: IMPACT Drafting & Design Inc. is not responsible for engineering,construction or materials. Individual contractors are responsible for meeting codes.IMPACT
D. Johnston 13 May 24
C. Johnston 15 May 24CONTACT/OWNERE.1 1/4" = 1'Electrical
Main Floor
Main Floor Electrical Second Floor Electrical
scale: 1/4" = 1'-0"scale: 1/4" = 1'-0"
= arc fault circuit interrupted outlet
= wall mounted doorbell
= garage door opener with outlet
= ceiling mounted fan fixture w/ light
= duplex outlet, 110 v.
ELECTRICAL LEGEND
= 220 outlet
= switch
= ground fault interrupting outlet (GFCI)
= ceiling mounted light fixture
= 3-way switch
= 4-way switch
= dimmer switch
= wall mounted light fixture
= waterproof outlet (GFCI)
= switched duplex outlet, 110 v.
= in floor duplex outlet, 110 v.
= phone / satellite jack (RJ11)
= thermostat
= flush, wall mounted, stair wash
= ceiling mounted fan fixture
= computer data port (RJ45)
= exhaust fan w/ light
= troffer light fixture (led/fluorescent/etc.)
= stereo / sound system jack
= television cable jack
= doorbell button
= garage door button or keypad
= track lighting
= over / under cabinet lighting
= carbon monoxide & smoke detector
= recessed, ceiling mounted light fixture
= recessed, ceiling mounted led 4"
= recessed, ceiling mounted led 6"
General Electrical Notes
- Smoke detectors to be interconnected
and have battery backup
- All Smoke Detectors outside Sleeping
Rooms and at the top and bottom of
stairs must also be a combination carbon
monoxide detector
- Smoke detectors may not:
- be within 36" of a bathroom with a
shower or tub
- be within 36" of a supply register
- be within 36" of the blade tips of a
ceiling fan
- Ionization Smoke detectors may not be
within 20' measured horizontally from
permanently installed cooking appliances
- Ionization Smoke detectors with alarm
silencing may not be within 10' measured
horizontally from permanently installed
cooking appliances
- Photoelectric Smoke detectors may not
be within 6' measured horizontally from
permanently installed cooking appliances
- Electrical outlets in kitchen, garage and
laundry to be 48" above floor level
- All outlets to be tamper resistant
- All interior recessed lights to be on
dimmer switches
- All Exterior Lights to be dark-sky
compliant
- Electrical plans may need to be
deviated from by electrician to meet
building specific needs either by design
or code, however those deviations must
be discussed with IMPACT Drafting,
Builder, or Client prior to being made.
No deviations may violate electrical
codes.
- Where the air infiltration rate of a
dwelling unit is less than 5 air changes
per hour when tested with a blower door
at a pressure of 0.2 inch w.c. (50Pa), the
dwelling unit shall be provide with
whole-house ventilation
- Bathroom circuiting shall either be: a)
a 20 amp dedicated circuit for each
bathroom or b) at least one 20 AMP
circuit supplying only bathroom outlets
- All Manufacturer's Installation
Instructions to be on site for inspector
for rough and final inspections..