Loading...
HomeMy WebLinkAboutSite Plan-Final-24X36 SITE a I I EX.STREET I I h h ' EX.JACK �( I I ADDRESS I I L O SETBACK LEGGED FENCE CIn3 IMITS O 5' SIDEYARD II II SIGN / S 89°23'54" Q N TRANSFORMER _________________________ ______---____ _--__ -__ a IRAo STORM PROPOSED SWR i PROPOSED 11\ 11 iELEPHo EI/ Ex.11 o"cMP I I> I r �5 �� BUILDING 1 1 BOX 7r INV.IN(N)=4749.03 I m �EX. 0000���� FOOTPRINTS 1 1 / INd-9UT(Q-4749.01 Z m m m m TELEPHONE PROPOSED (TYP) 1 11 -- l a I '� U U U U a I eox DETENTION PROPOSED FH\ - �1 1 - _ 1 I. BASIN 1 11 I --------- ' L Y4' WIDE PAVED a II PROPOSED J I 1� i> I j ,CCESS WAY w w w I STORM SWR I 1 - 24'X52' 1 II s O 24x52' ' 1 / I a I 1 SCALE w w w III 5B1 == 3563 I ' 11 " I I > I I I PROPERTY 0 15 30 60 I EX. EX.WOVEN II4 i I N J I 1 I TRANSFORMER WIRE FENCE Z 5 O 5' SIDEYARD r� Ys Oj /\!74 a I J1 PAD o U U U g Q- SETBACK IT'- P U L�L C I 1 q0' IDE PUBLIC STREET I w w w w 1 24'X52' > I & UTILIM EASEMENT a a a in PARK AREA A 24'X52• I EL \� 1 3579 1 1 J A PROJECT: ANNIE STREET COTTAGES ELECTRICAL O� I C� 3559 I N to to to ' I Box �' 27,276 Sq Et I ==I I - I s OWNER: COTTAGE PARTNERS II LP www w Ex. I� 1 I >OP ATTN: DAB DABNEY m TELEPHONE 2555 WEST COLLEGE SUITE B Box `O — I 1 1 I - 1> BOZEMAN, MT 59718 n —rt W r�D 24'X52' "��_ 24'X52' ERI T AC RDI 9 (406) 585-9808 0 P Ex.ELECTRICAL ah. 3,B I= PROPOSED 8"A•B o_ I PULL BOX I O ' I I "= " I PROPOSED 12' X 20 q SWR MAIN 3555 I ^ j ENGINEER: MADISON ENGINEERING LLC I s I 924ATT NERI G. DR. SUITSKI, PE 556-4450 Ex O CONCRETE PICNIC s O 1 I 1 924 STONERIDGE DR. SUITE 1 WAT 1 N PATIO WITH BENCH, os. 24' PROPOSED S h I I I BOZEMAN, MT 59718 SON Tq A,q MAIN I TABLE AND GRILL I I % (40 ® -_ -7.5-_---- -� 23585 -J-_ ,. - "_ 8" WATER 235512 _I 11 I LOCATION: CON660 STREET AND ® f l J -I I AN MEAGHER Ex O ® MAIN A N I -� csa 'J ve MAI R Z 1 u I I 1 n ----- ---------------J 5' 15' FRONTYAR 1 ZONING R2 1.0' SETBACK g //� g 11 1I ° GO > I EXT'G CURB g SITE AREA: 217,800 SF 24 PR F 8"OPOSEWTR MAIN DRAWN BY:CGB D ' - QE I FLOOR AREA: 39,600 SF18.2% 5.5:1 Is I w W I I j I IMPERVIOUS AREA: 65,110 SF29.9% REVIEWED BY:CGB EX.8"W/L i f I.w ANNE STREET A w VISION CLRNCE' PROPOSED w 1 4 I j 9 H 1 Is 1 LANDSCAPED AREA: 113,090 SF 51.9% PROJECT ENGINEER:CGB g 0 TRIANGLE (TYR 8" SWR MAIN I ll s s s s s s s —s s 1 1yl s s s s RON s s s s s s s s ss S s s f HOUSING PROPOSED DESIGNED BY:CGB MANHOLE NONE SEWER EXT'G ROADWAY j Ii I% 15'SETBACKS 47.0' ® EXT'G 74' WIDE—1 I L RIM=4749.12 RIGHT OF WAY Ip I 12 N 24 12' ROADWAY AND p 1 f Is III — ( P) >� A (TYpt— U In EASEMENT 1> N 11 30 - TWO BEDROOM UNITS a ' m. Po NE " DENSITY PER ACRE: 6.2 UNITS/ACRE EXT'G CURB E OF / " E 77 ° ° -r 1> 1 PROPER _ y s g D I LINE PARK AREA/OPEN SPACE REQUIREMENT: v INLET uv —uv \ v u —uv uv =1 =� I 1 PARK AREA 31 UNITS ® .03 ACRES/UNIT=40,510 SF T <a TLa4749?5_ ------------------- uv—uv u uv—uv j OPEN SPACE: 31 UNITS 150 SF/UNIT= 4,650 SF RIM=4748.88 1 O p O J O J O I 1s TOTAL 45,160 SF ___ __ (TYR_---_____- PROPOSED Ex.BA RE'FENCE °R �' I> I I EXISTING EDGE OF cn 1 FH (nP) PARK AREA/OPEN SPACES PROVIDED: 45,258 SF 28'X50' K I I E Qi 11 1 1 GRAVEL DRIVE W 9 > I I� 11 -Is 1 REQUIRED PARKING: 38 (� z W I L}I K 28'X50 24X52' ' ' 28'X52' = z I A,B,D,E -J I N I I 1 RESIDENTIAL Q Q j I I 3 3594 3588 31 - 2 BEDROOM UNITS 62 SPACES 596 a Q I L ANNIE 28 C50 I PU1 W I EX. II s 887 i ING SPACESDRIVEW YIDSTTALLS 26 SPACESL'j ~ TRANSFORMER I 28'X52' 0 ° L- 1 I ° II I I I I i> GARAGE SPACES 31 SPACES U (D PAD A,B,D,E m of (`HY) I STREET PARKING 7 SPACES Q I > - 1 TOTAL 74 SPACES (/) a W I _� II 895 1 s I `II 1 " PROPOSED EDGE Z :20Ex. r-� M " 20 (TYP) 1 W I OF PAVEMENT Q TELEPHONE I II 1 - A 28•X52• I a Its HANDICAP STALLS REQUIRED: 3 STALL (1 VAN ACCESSIBLE) LLJ HANDICAP STALLS PROVIDED: 3 STALL (1 VAN ACCESSIBLE) LLJ W Box PROPOSED A,B,D,E 1 fi W / 1 LLJ n PROPOSED I I W BUILDING 881 1 J Z NO 1- BUILDING FOOTPRINTS r-i 1 - (n / I> FOOTPRINTS 20' (nP) Z (TYR) _ ,fir i I KEY NOTES m (TYR) I= 28'X52' O >Q --J g °z II I II V) (/� A,B,D,E PUBLIC — ;� (D ° 3 W c Ex 'L 891 r-, 1 !6-I Y Y 9 I z QA 6" CONCRETE CURB & GUTTER. LLJ ELECTRICAL J11 /_gox I I s Q PARK AREA 24'X52' II J °Q I \ I B 4" THICK CONCRETE WALKS WITH BROOM FINISH. I I A,B = I EX.18 CMP O 5 A 1 3,332 Sr 869 9 11 " \� `Is INV.IN SW)=4761,36 © BARRIER FREE PARKING STALL WITH A.D.A SIGNAGE & STRIPING. z TELEPHONE Oj a W , 24+ �., I I j INV.OU(NE)=4749.33 O / Ex. 1 w I 28X52' N 4>� �I E (TY ) I 1 I I I D CONCRETE RAMP. SURFACE TEXTURE & SLOPE TO MEET A.D.A. Q ` gox o r 883 1 4' 28'X52' p `�11 " `4 O 12' oR 24' WIDE DRIVEWAY APPROACH PER C.O.B. STD DETAIL A,B,D,E I� OPEN SPACES a I �I II '0l2 4,650 Sf A'8°'E 1j, I 02529-11. 3)1 I UI 24' WIDE DRIVEWAY APPROACH PER C.O.B. STD DETAIL 02529-12. I I �I� BY RD '� 2 8 PROPOSED 12' X 20' 3 ISET.A CONCRETE PICNIC j N j " `I I © PAVEMENT STRIPPING AND MARKINGS a z 3 SWR & WTR PATIO WITH BENCH, c 1I I I ` 24' WIDE PAVED 28'X52' 0 = ,� EASEMENT TABLE AND GRILL I PROPOSED 8'• 8 I fpf> ° ACCESS WAY O ASPHALT PAVEMENT Q A,B,D,E PROPOSED FH PROPOSED 1 1 % E 12 � WATER MAIN Ex. I I C� W 15.Os IO (TA' ) I O CONCRETE PAVEMENT DRIVEWAY a 1 I 879 1 8" WTR MAIN A,B,D,' W,�Q 1 FORMER a Ex. 1 I I, r-r 1 A,B,D,E 1 - PROPOSED 8" I O 3/4-INCH COPPER WATER SERVICE & 4-INCH SANITARY SEWER — Lc) TRANSFORMER I - M D ® y PROPOSED 855 SWR MAIN SERVICE. �Ap 1 5 1 8" SAN SWR f_l_J 9 LLJ F- GO I OK "FIRE LANE - NO PARKING" SIGN. ATTACHED TO LITE POLE [n > 1 WHERE AVAILABLE. LLB n GO s I i �' Q•6 — aQ c —K — I T wEL I _ z Ln 24'x26' 1 I I L D 24' nP I I j> I PROPOSED 8" © RED PAINTED CURBING WITH "FIRE LANE - No PARKING" EX.SAN SEWER F _ R20.0' Imo- A I a 1 _L° I II( I WATER MAIN STENCILED ONTO CURB AS REQUIRED BY THE C.O.B. 2 COATS. (� (Q MANHOLE I x 873 `3' W w W W W w W w, v RIM=4751 s1 I D O 6' A 30' SWR & WTR 24 24, I I I iI I M "NO PARKING THIS SIDE OF STREET SIGNAGE z (� O I�s� s s �2. s B s s s s EASEMENT 4, I �' 16>'IPUEI " 0 MAIL BOXES - 2 16 UNIT BOXES WITH 4' X 6' CONCRETE SLAB - W < tt 4Ln I 24 F26 M .J TY J M ° I I j z C) W 'n R- N 1 i 871 y� O - 1 > I I 11 I 0) DE ELECTRICAL l J9 PROPERTY I I, I> NOTE: N Box J Iu LINE .I 01) J 28'X52' 28 X50' 0 # _ JA,B,D,' GARAGES SHALL BE SETBACK 20 FEET FROM THE Q 1 A,B,D,E q,g,p,E C 0 1 A,B4O.E 851 849 847 III 1 > RIGHT OF WAY OR ACCESS EASEMENT. _ 0 — 2 'x26 24'x26' 24'x26' 1 857 ® HANS0A EX.TELEPHONE I Fg F 859 > I I I 2. NO GROUND MOUNTED MECHANICAL EQUIPMENT, �I BOX IED 863 1 I 11 I n 11 I PROPOSED INCLUDING, BUT NOT LIMITED TO UTILITIES, AIR SHEET v x -- PRV STATION ail 1 1 EXCHANGE CONDITIONING UNITS AND METERS SHALL 20' REARY o D 15 FRONnARD > s Ex. NOT ENCROACH INTO THE REQUIRED YARD SETBACKS a Ci•0 SETBACK SETBACK 1 TELEPHONE I i �L I I gox AND WILL BE PROPERLY SCREENED WITH AN OPAQUE ANNIE STREET 14SOLID WALL AND ADEQUATE LANDSCAPE FEATURES. 4 1 N 89'23'54" W ��— 364.97- G�N�yoEX, MATCH LINE _ l SITE PLAN T LEPHONE 1 I i O WIRE FENCE - I> I 11 I __ -- PROJECT:O6-112 I I I� DATE: