HomeMy WebLinkAbout036_I2.1_IRRIGATION_DETAILSARCHITECT.
CONSENT OF THE LANDSCAPE
OR OWNER WITHOUT WRITTEN
OTHER PURPOSE, LOCATION,
IS NOT TO BE USED FOR ANY
SPECIFICALLY FOR THIS SITE AND
IT HAS BEEN PREPARED
OF THE LANDSCAPE ARCHITECT.
THIS DRAWING IS THE PROPERTY
STEINER THUESEN PLLC
2025
COPYRIGHT
SHEET CITY OF BOZEMANBOZEMAN SPORTS PARK PHASE 2FILE:
REV:
REV:
DATE:
CHECKED BY:
DATE:
DRAWN BY:GSG
6/27/25
NGS
6/27/25
-
-
P L L C
GOLF COURSE ARCHITECTURE
IRRIGATION DESIGN
LANDSCAPE ARCHITECTURE
1925 GRAND AVE. SUITE 105
P.O. BOX 22943
BILLINGS, MT 59104
406/252-5545 FAX 245-9855
THUESEN
STEINER
NATHAN
STEINER
143
G
CNLADS
APE ARCHITECTOMNTANA
R
EG
ISTERED
D
S
S
S
D DD
DD
D
D
D
D
D D
SSSS
D
D
D
D
5
5
6
4
4
IRRIGATION CONTROLLER SOLAR POWER EQUIPMENT SCHEMATIC6
NOT TO SCALE
NOTES:
3. ALL CONDUIT TO BE PAINTED TO MATCH BUILDING. SECURE CONDUIT TO BUILDING.
YEARS, AND (4) INDICATE HOW PROPOSED EQUIPMENT IS EQUAL TO OR BETTER THAN THE SPECIFIED EQUIPMENT.
INFORMATION CALLED FOR ON NOTE #1 ABOVE. (3) PROVIDE INFORMATION ON SIMILAR INSTALLATIONS WITHIN THE PREVIOUS 3
(3-24VAC IRRIGATION VALVES, 1-24 VAC MASTER VALVE, 10 HRS/DAY, 4 DAYS/WEEK, APRIL-OCTOBER), (2) INCLUDE ALL SUBMITTAL
SUBSTITUTION REQUESTS SHALL; (1) INDICATE THE ABILITY TO OPERATE (1) HUNTER ACC2 CONTROLLER AND 38 DECODERS
2. SOLAR EQUIPMENT TO BE BY CONTROL TECH USA, MODEL #SPS-RSG344213133-1B3, OR EQUAL APPROVED IN ADVANCE.
SIZES, GROUNDING, ELECTRICAL ONE DRAWING, ETC.
INCLUDE DRAWINGS INDICATING MOUNTING ON RESTROOM TILT ANGLE & DECLINATION, ENCLOSURE, SPECIFIC WIRE TYPE &
1. DETAIL IS SCHEMATIC, PROVIDE SUBMITTALS INDICATING ALL EQUIPMENT, WIRE, ETC. FOR INSTALLATION. SUBMITTAL TO
LEGEND:
IRRIGATION CONTROLLER AS SPECIFIED.
4
5
6
7
8
9
10
11
2
3
12
1
CONTROLLER GROUNDING AS SPECIFIED.
2-WIRE CONTROL CABLE IN CONDUIT.
THE MANUFACTURER.
SOLAR PANELS/SOLAR ARRAY.TILT ANGLE AND DECLINATION PER
WEDGE ANCHOR OR SIMILAR.
SOLAR PANEL MOUNT FEET (4) TO BE ANCHORED W/ 3/8" DIA. MIN.
CONDUIT: 1/2" LIQUID TIGHT METALLIC FLEX
GREEN 10 AWG TYPE THWN-2
BLACK 10 AWG TYPE THWN-2
RED 10 AWG TYPE THWN-2
SOLAR ARRAY WIRES:
TO MOUNT ENCLOSURE TO THE WALL.
TO HOLD THE WEIGHT. USE SUPPLIER PROVIDED BRACKETS OR UNISTRUT
APPROXIMATELY 250 POUNDS. ANCHOR MOUNTING BRACKETS SUFFICIENTLY
BATTERIES AND INVERTER. FULLY LOADED ENCLOSURE WILL WEIGH
WALL MOUNT ALUMINUM ENCLOSURE HOUSES SOLAR ELECTRONICS,
6 AWG SOLID COPPER WIRE IN CONDUIT TO GROUNDING SYSTEM.
COVER W/ 10" ROUND VALVE BOX.
COPPER PLATE. CONNECT TO GROUND ROD WITH CADWELD.
GROUNDING SYSTEM - 5/8"X 8' COPPER CLAD ROD AND 3"X 10'
SOLAR GROUND WITH IRRIGATION EQUIPMENT GROUND.
DIRECT BURY 6 AWG SOLID COPPER WIRE MINIMUM TO BOND
PRE-CAST CONCRETE RESTROOM BY OTHERS.
MAXIMUM WIRE LENGTH: 50'
TO IRRIGATION CONTROLLER)
CONDUIT: 3/4' GREY PVC (FROM WALL MOUNT ENCLOSURE
GREEN 10 AWG TYPE THWN-2
BLACK 12 AWG TYPE THWN-2
RED 12 AWG TYPE GHWN-2
120VAC WIRES:
1
2
3
6
8
9
10
7
11
5
12
I2.3
I2.3 IRRIGATION DETAILS.DGNIRRIGATION DETAILS2-WIRE ROUTING PLAN4
2-WIRE SPLICE BOX FOR
SATELLITE CONTROLLER
LEGEND:
2 TYPICAL ELECTRIC CONTROL VALVE
NOT TO SCALE18"12"20
7 8
12
13
4
3
2
1
15
19
ACCESS FOR SERVICING.
3. KEEP CONDUIT BACK FROM ELECTRIC VALVE TO ALLOW
2. REMOVE ANY WATER IN CONDUIT PRIOR TO SEALING ENDS.
ELECTRIC VALVE SIZE CALLED FOR ON PLANS.
1. ADJUST SIZE OF LATERAL 90°, AND PVC FITTINGS TO MATCH
NOTES:
LEGEND:
20. 1" MIN. SPACE BETWEEN LATERAL AND VALVE BOX.
19. MIN. 4 CONC. BLOCKS, ONE EACH CORNER.
SEAL ENDS WITH DUCT SEALANT.
18. 2-WIRE CONTROL CABLE IN CONDUIT, 1" MIN.
LEG COILED UP NEATLY IN VALVE BOX.
17. PROVIDE 3' MINIMUM OF 2-WIRE CABLE ON EACH
16. DECODER, AS SPECIFIED.
15. VALVE ID TAG, AS SPECIFIED.
SPLICES IN VALVE BOX.
14. DBY WIRE CONNECTORS AS SPECIFIED, MAKE ALL
13. PROVIDE 20 EXPANSION COILS EACH WIRE.
12. FINISH GRADE.
11. VALVE BOX AS SPECIFIED, RISER AS REQUIRED.
2" CLEARANCE BELOW VALVE.
10. 6" OF WASHED 3/4" AGGREGATE BASE, MAINTAIN
9. SOLVENT WELD PIPE TO LATERALS.
8. 3" X 2" SCH 80 1 PIECE REDUCER COUPLING.
7. 2" X 4" SCH. 80 T.O.E. NIPPLE.
6. 2" - T X T SCH. 80 UNION.
5. 2" X 2" T.B.E. SCH 80 NIPPLE.
4. ELECTRIC VALVE AS SPECIFIED.
3. 2" HARCO LATERAL 90° SWIVEL.
2. HARCO D.I. SWIVEL TEE.
1. MAINLINE.
9
11
6
5
18
17
10
1614
MASTER VALVE & FLOW SENSOR 3
NOT TO SCALE
FLOW
...
SEE NOTE #1.
NOTES:
DI TAPPED CAP W/ RESTRAINT.
PIPE W/ SCH 80 PVC MALE ADAPTER, SIZE TO MATCH FLOW SENSOR.
PIPE SIZE TO MATCH SIZE OF FLOW SENSOR.
SCH 80 PVC REDUCER, AS REQUIRED.
PVC PIPE, SAME SIZE AS MASTER VALVE.
SCH 80 TOE NIPPLE.
SCH 80 PVC UNION. USE BRASS UNION ON 2" AND LARGER.
DI NIPPLE, SIZE TO MATCH MASTER VALVE.
DI TAPPED CAP W/ RESTRAINT.
MAINLINE.
FLOW SENSOR, ANGLE PER MANUFACTURER'S RECOMMENDATIONS.
MASTER VALVE.
GATE VALVE, SAME SIZE AS MASTER VALVE.
3. SECURE DECODER TO VALVE BOX WITH ZIP-TIE.
2. REFER TO LEGEND ON PLAN SHEETS FOR ADDITIONAL INFORMATION FOR MASTER VALVE AND FLOW SENSOR.
5X PIPE DIA. OF STRAIGHT CLEAN RUN OF PIPE, NO FITTINGS OR TURNS.
1. INLET PIPE LENGTH OF FLOW SENSOR MUST BE MIN. 10X PIPE DIA. STRAIGHT, CLEAN RUN OF PIPE, NO FITTINGS OR TURNS. OUTLET PIPE LENGTH OF FLOW SENSOR MUST BE MIN.
4
5
6
7
8
9
10
11
15
16
18
19
20
21
22
17
MAINLINE, SEE PLAN FOR SIZE
6" 3/4" WASHED AGGREGATE
MIN. 4 CONCRETE BLOCKS, TWO EACH SIDE.
1" MINIMUM SPACE BETWEEN LATERAL AND VALVE BOX.
FINISH GRADE.
VALVE BOX AND EXTENSION, AS SPECIFIED.
MARKER TAPE OVER 2-WIRE PATH IN CONDUIT.
2-WIRE PATH TO CONTROLLER/DECODERS IN CONDUIT, 1" MIN.
WIRE CONNECTORS, AS SPECIFIED.
SLACK DECODER PATH WIRE, AS SPECIFIED.
FLOW SENSOR DECODER (ICD-SEN) WITH WIRES TO FLOW SENSOR AND 2-WIRE PATH.
MASTER VALVE DECODER (ICD-100) WITH WIRES TO MASTER VALVE AND 2-WIRE PATH.
SUBMAINLINE PIPE TO CONTROL VALVES. SEE PLAN FOR SIZE.
23
LEGEND:
1
2
3
13
24
12 25
14 18" MINIMUMCOVER8
6
6
23
23
1
14
13 3
10
9
7 7
2
24
25
19
18
11
17
22
18
21
20
17
12
16
15
POSSIBLE
60-90° IF
INSTALL AT
.
6
5
19
26
26
5
NOTES:
WIRELESS SOLAR SYNC
LEGEND:
4. FINISH GRADE.
3. CONCRETE FOOTING - 18" DIA. x 24" DEEP MIN., SLOPE TO DRAIN.
CUT AT 45° ANGLE AS SHOWN. WELD PLATE ON TOP AS COVER.
2. 6"x6" SQ. TUBE STEEL, PRIME AND POWDER COAT BLACK. TOP TO BE
SENSOR GUARD.
1. SOLAR SYNC AS SPECIFIED. MOUNT TO SQ. TUBE. INSTALL WIRELESS
IS 800' FIELD VERIFY.
2. MAX. DISTANCE FROM CONTROLLER
1. TUBE STEEL TO BE WATER TIGHT.
1
2
4
3
24"10'NOT TO SCALE NOT TO SCALE
FUTURE CONNECTION
WIRE PATH #2 (GRAY)
WIRE PATH #1 (BLUE)
NOTES:
2. INSTALL PULL BOXES AS NOTED ON DETAIL.
INSTALL MARKER TAPE OVER 2-WIRE PATH.
1. ALL WIRE SHALL BE INSTALLED IN CONDUIT, 1" MIN. ALONG MAILINE. 18" MIN. 1 2-WIRE CONTROL PULL / SPLICE BOX
DRAWINGS.
2. INCLUDE PULL/SPLICE BOXES ON AS-BUILT
CONDUIT WITH DUCT SEALANT.
TO WITHIN 6" OF CARSON BOX COVER AND CLOSE
1. AT PULL/SPLICE LOCATIONS EXTEND CONDUIT
DIRECTIONAL CHANGES
& AT ALL JUNCTIONS &
PULL BOXES 300' O.C. MAX.
4
3
10
76" MIN. NOTES:
LEGEND:
6
5
9
8
2
1
10. CONC. SUPPORT BLOCK EACH CORNER.
PERMITTED ONLY AT DECODERS.
9. SPLICES MADE WITH DBY SPLICE KITS. FIELD SPLICES
8. MIN. 60" LOOP OF CONDUCTORS IN PULL BOX.
7. 90° SWEEP ELL.
6. PVC SCHED 40 CONDUIT SIZE AS REQUIRED, 1" MIN.
5. MIN. 4" DEPTH CRUSHED AGGREGATE.
AND DECODERS.
4. 2-WIRE COMM CABLE TO SATELLITE CONTROLLERS
3. PANDUIT HTDU 3R-E MARKER TAPE CONTINUOUS.
ELECTRICAL MARKING.
2. CARSON 1419-12 BOX & 1419-3B GREY COVER,
1. FINISH GRADE
NOT TO SCALE
NIC - FUTURE PHASE
D