Loading...
HomeMy WebLinkAbout035_I2.1_IRRIGATION_DETAILSI2.2 I2.1 IRRIGATION DETAILS.DGNIRRIGATION DETAILSAA 2 TYPICAL THRUST BLOCKS 18" 36" 36" B 30" 24" 21" 32" 45" 61" 87" A 24" 33" 40" 50" 61" A 12" 18" 24" 30" 36" B 9" 12" 16" 20" 28" A 12" 18" 24" 30" 30" B 24" 12" 40" 56" 30" A 30" 30" 24" 18" 17" B 3-4" 6" 8" 10" 12" ELBOWS PLUGS TEES & SIZE PIPE SECTION A-A FINISH GRADE CONCRETE THRUST BLOCK A18" MIN. B 22-1/2°45°90° NOT TO SCALE NOTES: 3. THRUST BLOCKS NOT REQUIRED ON 2-1/2" & SMALLER PIPE. ADEQUATE THRUST BLOCKS IN ALL PIPING INSTALLATION. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTING 1. ALL PIPES TO BE CENTERED ON THRUST BLOCKS. A A NOT TO SCALE CAMLOCK ASSEMBLY3 NOTES: 2. EDGE OF VALVE BOX TO BE 12" OFF OF PAVEMENT EDGE. COORDINATE VALVE BOX ELEVATION WITH PAVEMENT ELEVATION. 1. COORDINATE CAMLOCK ASSEMBLY WITH FITTINGS ON TRAVELING SPRINKLER TO ENSURE COMPATIBILITY. COUPLER CAM & GROOVE 2" BRASS FEMALE LENGTH AS REQUIRED (2) 2" STEEL RISERS, AS SPECIFIED VALVE BOX OVER MAINLINE 1" MIN. SPACE BLOCK PER SCHEDULE CONCRETE THRUST CAMLOCK ASSEMBLY RESTRAINT ON PIPE TO LEEMCO DI TEE W/ LH SERIES TEE & ELBOW NO JOINTS BETWEEN ONE EACH SIDE MIN. 4 CONC.BLOCKS, AGGREGATE BASE 6" WASHED 3/4" ASPHALT PAVING EXTENSION BOX AS SPECIFIED 2" GATE VALVE AS SPECIFIED LEEMCO 3X2 TAPPED PLUG LEEMCO DI ELBOW W/ LH SERIES RESTRAINTS SIZE AS REQUIRED TO WORK WITH PAVEMENT THRUST BLOCK PER SCHEUDLE. ADJUST C SECTION PLAN VIEW WITHIN THE SPHERE OF INFLUENCE DO NOT INSTALL ANY OTHER WIRES OR CABLE 5 CONTROLLER GROUNDING (4" x 96" x .0625) COPPER GROUND PLATE CONTROLLER WIRES BARE COPPER #6 AWG SOLID CONNECTION CADWELD MATERIAL EARTH CONTACT TYP. (5/8" x 8') GROUND ROD BOUNDARIES OF INFLUENCE ELECTRODE SPHERE NOT TO SCALE 8-12'10' DEPTH OR BELOW FROST DEPTH: 30" MIN. GROUND PLATE NOTES: 1. INSTALL 10" ROUND VALVE BOX OVER GROUND ROD.12"LEGEND: NOTES: 6. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. LAST DECODER ON ALL WIRE PATHS TO BE GROUNDED. 4. GROUND PLATES TO BE A MINIMUM OF 8' PERPENDICULAR FROM 2-WIRE PATH. CADWELD OR U-BOLT CONNECTORS. RESISTANCE TO BE 10 OHMS OR LESS. 3. DECODER GROUND WIRE TO BE CONNECTED TO GROUND PLATE WITH 2. INSTALL GROUND PLATES EVERY 1000' OR 12TH DECODER ALONG 2-WIRE PATH. ARCHITECT OF ANY DISCREPANCIES. INDICATED ON PLANS MEET GUIDELINES SHOWN ABOVE. NOTIFY LANDSCAPE 1. CONTRACTOR SHALL VERIFY THAT LOCATIONS OF GROUND PLATES 2-WIRE PATH DECODER DECODER GROUND PLATE CONTROLLER 6 DECODER GROUNDING SCHEMATIC MAX. 25' MAX. 1000' NOT TO SCALE DECODER OR 12TH 12TH DECODER 1000' MAX. OR 12TH DECODER 1000' MAX. OR 500'KEY FOR CONNECTIONS: 14/12 AWG RED 14/12 AWG BLUE REDBLUETYPCIAL DECODER GROUND 3M MODEL DBY-6 3M MODEL DBR-6 DECODER W/ GROUND WIRE IDSWIRE TWISTED CABLE FROM GROUND PLATE BARE COPPER WIRE WITH DECODER IN VALVE BOX ALL WIRE SPLICES OR BELOW FROST) MIN. 30" BELOW GRADE 8' FROM TWISTED CABLE, IRRIGATED AREA, PLATE (INSTALL IN 4" X 36" GROUND 7 CADWELD OR U-BOLT NOT TO SCALE RECEIVER & GUARD WIRELESS SOLAR SYNC 4 30"18"6" TYP.TYP. 6" TYP. 6" WITH 6/6/6 WWM TROWEL FINISH, CONCRETE FOOTING- CADWELD CONNECTION SET TO GRADE SPECIFIED - VALVE BOX AS CONDUIT FOR GROUND GRADE FINISH POWER SOURCE CONDUIT FOR 120 V. TO OUTLET J-BOX, CORD PIGTAIL CONTROLLER TO POWER LEADS FROM SURGE ARRESTOR W/ INTERMATIC #AG2401 GFCI DUPLEX OUTLET RECOMMENDATIONS MOUNT PER MFGR'S SATELLITE CONTROLLERS GROUND PLATE AND ON TO GROUNDING ROD 5/8" X 8' COPPER 2-WIRE PATH CONDUIT FOR CAD WELD TO GROUNDING ROD #6 BARE COPPER GROUND WIRE SATELLITE CONTROLLERS NEEDS PRIOR TO ORDERING ANTENNA. 5. PROVIDE MANUFACTURER (HUNTER) CELLULAR SIGNAL TEST TO CONFIRM ANTENNA 4. SEE CONTROLLER GROUNDING DETAIL FOR ADDITIONAL INFORMATION. 3. PROVIDE ONE 2" 2-WIRE CONDUIT. 2. MIN. CONDUIT SIZE TO BE 1". FOR CONTROLLER PADS WITH ONE CONTROLLER 6/6/6 WWM IS OPTIONAL. 1. FOR CONTROLLER PADS WITH MORE THAN ONE CONTROLLER 6/6/6 WWM IS REQUIRED. DRAIN SLOPE TO 6" NOTES: 1" CONDUIT (EXTRA) NOT TO SCALE MOUNT ANTENNA HUNTER EXTERNAL TRENCHING DETAILS - 2-WIRE PLANS LATERAL SECTIONS FINISH GRADEFINISH GRADE LATERAL MAINLINE TRENCH PIPE IN LATERAL SNAKE ALL 18"12"18"12" (IN CONDUIT) 2-WIRE PATH CONTINOUS TAPE MARKING CONTINOUS TAPE MARKING LOCATED ON AS-BUILT PLANS. BE MADE IN VALVE BOXES AND MAINLINE. ALL SPLICES SHALL ABOVE ALL 120 V. WIRING AND USE 6" WIDE MARKING TAPE 6" AFTER MAKING CONNECTIONS. GREATER THAN 30°. UNTIE ALL LOOPS CABLE AT ALL CHANGES IN DIRECTION TIE A LOOSE 20" LOOP IN 2-WIRE COMM 1 NOT TO SCALE AS SHOWN. . 2-WIRE COMM CABLE TO BE INSTALLED ON THE SIDE OF THE MAINLINE2 AS SHOWN ON THE PLANS. 1. 120 V. WIRE TO BE INSTALLED ON THE SIDE OF THE MAINLINE IN CONDUIT NOTES: SECTION CONDUIT PLAN CONDUIT FINISH GRADE MIN. 30" MARKING TAPE 12"(IN CONDUIT) 2-WIRE PATH BEDDING. CABLE 2-WIRE COMM 120 V. WIRE IN CONDUIT ARCHITECT. CONSENT OF THE LANDSCAPE OR OWNER WITHOUT WRITTEN OTHER PURPOSE, LOCATION, IS NOT TO BE USED FOR ANY SPECIFICALLY FOR THIS SITE AND IT HAS BEEN PREPARED OF THE LANDSCAPE ARCHITECT. THIS DRAWING IS THE PROPERTY STEINER THUESEN PLLC 2025 COPYRIGHT SHEET CITY OF BOZEMANBOZEMAN SPORTS PARK PHASE 2FILE: REV: REV: DATE: CHECKED BY: DATE: DRAWN BY:GSG 6/27/25 NGS 6/27/25 - - P L L C GOLF COURSE ARCHITECTURE IRRIGATION DESIGN LANDSCAPE ARCHITECTURE 1925 GRAND AVE. SUITE 105 P.O. BOX 22943 BILLINGS, MT 59104 406/252-5545 FAX 245-9855 THUESEN STEINER NATHAN STEINER 143 G CNLADS APE ARCHITECTOMNTANA R EG ISTERED