HomeMy WebLinkAbout022_L2.1_PLANTING_DETAILSARCHITECT.
CONSENT OF THE LANDSCAPE
OR OWNER WITHOUT WRITTEN
OTHER PURPOSE, LOCATION,
IS NOT TO BE USED FOR ANY
SPECIFICALLY FOR THIS SITE AND
IT HAS BEEN PREPARED
OF THE LANDSCAPE ARCHITECT.
THIS DRAWING IS THE PROPERTY
STEINER THUESEN PLLC
2025
COPYRIGHT
SHEET CITY OF BOZEMANBOZEMAN SPORTS PARK PHASE 2FILE:
REV:
REV:
DATE:
CHECKED BY:
DATE:
DRAWN BY:GSG
6/27/25
NGS
6/27/25
-
-
P L L C
GOLF COURSE ARCHITECTURE
IRRIGATION DESIGN
LANDSCAPE ARCHITECTURE
1925 GRAND AVE. SUITE 105
P.O. BOX 22943
BILLINGS, MT 59104
406/252-5545 FAX 245-9855
THUESEN
STEINER
NATHAN
STEINER
143
G
CNLADS
APE ARCHITECTOMNTANA
R
EG
ISTERED
L2.1
L2.1 PLANTING DETAILS.DGNPLANTING DETAILSNOT TO SCALE
LINEAR SPACING AT JOINTS.
SPACING 3' O.C. & 1' O.C.
WEED BARRIER, TRIANGULAR
8"STAPLES TO ANCHOR
SPECIFIED. LAP 3" AT JOINTS.
WEED BARRIER FABRIC AS
SPECIFICATIONS
MANUFACTURER'S
& INSTALL ACCORDING TO
EDGING AS SPECIFIED, STAKE
GRADE
FINISH
SPECIFIED
4" MULCH AS
1 EDGING, MULCH & FABRIC 3"1/2"3 ORNAMENTAL GRASS PLANTING
NOT TO SCALE
BEFORE PLANTING.
EXCESS CONTAINER GROWTH MEDIUM
AWAY FROM STEM RADIALLY. REMOVE
ROOTS. ARRANGE ROOTS TO POINT
ROOT BALL. PRUNE OFF GIRDLING
REMOVE CONTAINER AND INSPECT 1" MIN.FINISH GRADE
BED EDGING
FINISH GRADE
BARRIER AS SPECIFIED.
4" MULCH OVER WEED
SAUCER.
AREAS SHALL HAVE EARTH
ONLY PLANTS IN NATIVE
AIR POCKETS.
INSTALLATION TO ELIMINATE
THOROUGHLY AFTER
WATER. WATER IN
IN LAYERS, SETTLE WITH
SPECIFIED AMENDMENTS
EXISTING SOIL AND ANY
SOIL. BACKFILL HOLE WITH
BALL RESTS ON UNDISTURBED
TO BREAK GLAZING. ROOT
OF BALL. ROUGHEN SIDES
DIG HOLE MIN. 2X WIDTH
AWAY FROM PLANT.
KEEP MULCH 2"-3"
FINISH GRADE
PLANT FORM.
TO RETAIN NATURAL
PRUNE AS SPECIFIED
2 SHRUB PLANTING
FINISH GRADE
ONE YEAR.
SAUCER. REMOVE AFTER
AREAS SHALL HAVE EARTH
ONLY PLANTS IN NATIVE 1" MIN.BED EDGING
BEFORE PLANTING.
EXCESS CONTAINER GROWTH MEDIUM
AWAY FROM STEM RADIALLY. REMOVE
ROOTS. ARRANGE ROOTS TO POINT
ROOT BALL. PRUNE OFF GIRDLING
REMOVE CONTAINER AND INSPECT
BARRIER AS SPECIFIED.
4" MULCH OVER WEED
AIR POCKETS.
INSTALLATION TO ELIMINATE
THOROUGHLY AFTER
WATER. WATER IN
IN LAYERS, SETTLE WITH
SPECIFIED AMENDMENTS
EXISTING SOIL AND ANY
BACKFILL HOLE WITH
ON UNDISTURBED SOIL.
GLAZING. ROOT BALL RESTS
ROUGHEN SIDES TO BREAK
PLANTED POT TO POT.
OF BALL. EXCEPT HEDGES
DIG HOLE MIN. 2X WIDTH
NOT TO SCALE
AWAY FROM PLANT.
KEEP MULCH 2"-3"
STAKES 1 YEAR AFTER PLANTING.
1. CONTRACTOR TO REMOVE
FROM BALL AS NEEDED.
ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL
ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY.
ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL
REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF
PRUNE AS SPECIFIED TO RETAIN NATURAL FORM.
FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE.3/4- 2/31/4- 1/3UNBURIEDBURIEDFINISH GRADE
MULCHPERIOD.
TREE TO SWAY. CONTRACTOR TO REMOVE TIES AT END OF WARRANTY
SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING
PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES
STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT
6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON
TRUNK. MULCH TO EXTEND BEYOND STAKES.
4" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM
WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS.
SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER.
ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING
DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING.
1
22
3
4
5
6
7
LEGEND:
NOTE:
GRAFT UNION TYP. 4-6" ABOVE ROOT FLARE.
FROM BALL AS NEEDED.
ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL
ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY.
ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL
REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF
1
25
SECURE WITH ELECTRICAL TAPE. DO NOT WRAP TIGHTLY.
ASPHALT COATED PAPER TREE WRAP TO BOTTOM OF FIRST BRANCH,
FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE.
6
4
9
8
PRUNE AS SPECIFIED TO RETAIN NATURAL FORM.
WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS.
SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER.
ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING
DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING.
TRUNK. MULCH TO EXTEND BEYOND STAKES.
4" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM
AT END OF WARRANTY PERIOD.
TREE TO SWAY. CONTRACTOR TO REMOVE TRUNK WRAP, STAKES & TIES
SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING
PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES
STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT
6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON
LEGEND:1" FLARE VISIBLENOT TO SCALE
4 CONIFEROUS TREE PLANTING 5 DECIDUOUS TREE PLANTING 1" FLARE VISIBLENOT TO SCALE
6 LANDSCAPE BOULDER PLACEMENT
NOT TO SCALE
33
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
9
'8
'
ROCK MULCH.
36" DIA. BARK MULCH RING AT BASE OF TREE, INCLUDING IN PLANTER WITH 8
ROCK MULCH.
36" DIA. BARK MULCH RING AT BASE OF TREE, INCLUDING IN PLANTER WITH 10
10
STAKES 1 YEAR AFTER PLANTING.
1. CONTRACTOR TO REMOVE
NOTE: