HomeMy WebLinkAbout14-A-6 - Surgery Floor PlanA4.00B4A4.00B1A4.00B2A4.00B31A5.00B1A5.00B1A5.10B2A5.11B3A5.11B1A5.11B1A7.00B3A5.10B2A5.10BSGSGS8S8S2S2S4S4SASAS6S6SBSBSFSFS7S7S1S1S3S3SCSHSDSDS9S9S5S5SE2A8.01B2A7.00B1A8.00B3A8.00B7A8.00B6A8.01B7A8.01B9A8.01B5A8.01B8A8.00B5A8.00B6A8.00B8A8.01B2A8.00B4A8.01B1A8.01B3A8.01B9A1.50B16A8.00B14A8.00B15A8.00B13A8.00B4A8.00BMEDICAL GASS11I.T.S04A6.00B4A6.00B3A6.00B2S13AA6.00B1PROCEDURE ROOMS15OPERATING ROOMS16SURGICAL LOBBYS01PUBLIC TOILETS02DECONTAMINATIONS21CLEAN WORK ROOM/STERILESTORAGES20STAFF LOUNGES18STAFF TOILETS17FIRE RISERS22ENVIRONMENTAL SERVICESS23PRE/POST-OPS07PRE/POST-OPS06STAFF/PATIENT TOILETS08CORRIDORS05CORRIDORS14RECEPTION/NURSE STATIONS03MECHANICAL/PUMPS12ELECTRICALS10EQUIPMENT STORAGES19VESTIBULES13
VESTIBULES09S21S20S01AS09BS09AS08S23S01BS02S17S18S15BS16BS22S10S12S01CS13BS11S04S19S09CCJAAAEJJMMJJCACEBBBAACACAACAADDDDACAEJCAAUVMJUUMBACW-3W-2W-3CAUS16AJJS15APHARMACY133MEDICAL GAS139SOILED LINEN HOLDING138BODY HOLD137BULK STORAGE143ELECTRICAL146EMERG. ELEC.147MECHANICAL/RISER1487"REFERENCE HOSPITAL DRAWINGS FOR INFORMATION IN THIS AREAEYEWASH STATIONSTERILIZEREYEWASH STATION3-COMPARTMENT SINKPASS-THRUCLINICAL SERVICE SINKA6.00B2SIM.O.H.A6.00B5REFER TO KEYED PLAN NOTES WITH SYMBOL1. PROVIDE LEAD LINED EXTERIOR WALL IN ROOM -REFER TO PHYSICIST REPORT FOR THICKNESS AND HEIGHT2. FIRE DEPARTMENT CONNECTION -REFER TO MEP DRAWINGS3. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION4. ROOF LADDER TO ROOF HATCH -30"x36" BILCOTYPE S-50TB OR EQUIVALENT5. PROVIDE 9'-6" TALL ACCORDION PARTITION SYSTEM -BASIS OF DESGN -MODERNFOLD - SOUNDMASTER SM-8 DIRECTIONAL PERPENDICULAR -NO POCKET -FINISH TO BE SELECTED BY ARCH. FROM MANUF. STANDARDS KEYED PLAN NOTES:WALL TYPE LEGENDALL INTERIOR WALLS ARE TYPE , U.N.O.3 5/8" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE TO ROOF DECK.3 5/8" METAL STUD WALL, 1-HOUR RATED (U.L.-465 - REFER TO SHEET G2.04)), W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK.6" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND(1) LAYER 5/8" GYP. BOARD ON EACH SIDE TO ROOF DECK.3 5/8" METAL STUD FURRING WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON ONESIDE TO 6" ABOVE CEILING.3 5/8" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE TO 6" ABOVE CEILING.3 5/8" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE. PARTIAL HEIGHT -REFERENCE ELEVATIONS FOR EXTENT.6" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND(1) LAYER 5/8" GYP. BOARD ON EACH SIDE . PARTIAL HEIGHT - REFERENCE ELEVATIONS FOR EXTENT.6" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND(1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE TO 6" ABOVE CEILING.3 5/8" METAL STUD FURRING WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON ONESIDE TO ROOF DECK.3 5/8" METAL STUD WALL SMOKE BARRIER, 1-HOUR RATED (U.L.-465 - REFER TO SHEET G2.04)), W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK.6" METAL STUD WALL SMOKE BARRIER, 1-HOUR RATED (U.L.-465 - REFER TO SHEET G2.04)), W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK.6" METAL STUD WALL, 1-HOUR RATED (U.L.-465 - REFER TO SHEET G2.04)), W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK. SMOKE PARTITION TO MEET ALL REQUIREMENTS PER SECTION 710 OF 2018 IBC -3 5/8" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE TO ROOF DECK.SMOKE PARTITION TO MEET ALL REQUIREMENTS PER SECTION 710 OF 2018 IBC -6" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND(1) LAYER 5/8" GYP. BOARD ON EACH SIDE TO ROOF DECK.SMOKE PARTITION TO MEET ALL REQUIREMENTS PER SECTION 710 OF 2018 IBC -3 5/8" METAL STUD FURRING WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON ONESIDE TO ROOF DECK.3 5/8" METAL STUD WALL, W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" GYP. BOARD ON EACH SIDE TO ROOF DECK.PROVIDE LEAD SHIELDING - REFER TO PHYSICIST REPORT FOR THICKNESS AND HEIGHT3 5/8" METAL STUD WALL, 1-HOUR RATED (U.L.-465 - REFER TO SHEET G2.04)), W/ FULL THICKNESS ATTENUATION INSULATION AND (1) LAYER OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECKPROVIDE LEAD SHIELDING - REFER TO PHYSICIST REPORT FOR THICKNESS AND HEIGHT3 5/8" METAL STUD WALL, 2-HOUR RATED (U.L.-419 - REFER TO SHEET G2.03)), W/ FULL THICKNESS ATTENUATION INSULATION AND (2) LAYERS OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK.6" METAL STUD WALL, 2-HOUR RATED (U.L.-419 - REFER TO SHEET G2.03)), W/ FULL THICKNESS ATTENUATION INSULATION AND (2) LAYERS OF 5/8" TYPE X GYP. BOARD ON EACH SIDE. SEAL WALL AT UNDERSIDE OF ROOF DECK.AABCDEFGHJKLMXNPRSTUVPRELIMINARYNOT FOR CONSTRUCTIONNot for permits, pricing or other official purposes.This document has not been completed or checked and is for general information or comment only.ISSUE DATES:3514 CEDAR SPRINGS ROAD DALLAS, TEXAS 75219 | PHONE: 469-607-0006SAEED MAHBOUBI AIASAEED MAHBOUBI ARCHITECTURE2/14/2025 2:02:56 PMJOB NO. 2025-01A NEW PROJECT FOR: EXCEPTIONAL HEALTHCARE02/14/2025NOTATION FLOORPLAN - SURGICALBUILDINGSurgical Building -Bozeman, Montana200 NELSON ROADA-602/14/2025NO. DESCRIPTION DATE1/4" = 1'-0"1GROUND FLOOR NOTATION PLAN