Loading...
HomeMy WebLinkAboutWater-Sewer Flow Memo 1 of 2 Technical Memo To: City of Bozeman From: Daniel Stewart Date: April 9, 2025 Re: Water and Sewer Flows - Nelson Meadows Lots 21 and 22, Block 1 – Exception Health Job: 10875 Exceptional Healthcare will be developed on Lots 21 and 22, Block 1 of the Nelson Meadows Subdivision. The purpose of this memo is to demonstrate the water and wastewater flows for the site. Wastewater Flows The sanitary sewer flows for the Nelson Meadows subdivision were calculated in the “Nelson Meadows Subdivision Water and Wastewater Report” dated February 2018 by Morrison- Majerle. The total wastewater generated for the M-1 zoned subdivision is 960 gallons per day per acre. A peaking factor of 3.87 was in the report resulting in a peak hour flow of 3,715 gallon per day per acre. The Exceptional Healthcare site is 3.78 acres. Using the Nelson Meadows design criteria of 960 gallons per acres, the sewer design capacity for the site is 3,629 gallons per day with a peak hour flow of 14,044 gallons per day. The development is a medical facility with 19 beds and 40 employees. Utilizing Table 3.1-1 in Circular DEQ 4 classified as medical hospital, the typical wastewater flow is 165 gpd/bed and 10 gpd/employee. The calculated wastewater flow for the Exceptional Healthcare site is: Average Sewer Demand = 165 gpd/bed x 19 beds plus 10 gpd/employee x 28 employees = 3,135 gpd plus 280 gpd = 3,415 gpd Peak hour flow rate = 3,415 gpd x 3.87 = 13,216 gpd 2 of 2 The estimated wastewater flow from the Exceptional Healthcare site is less than the than the design capacity of the site. Water Usage The water design report for Nelson Meadows computed the average daily flow rate be 170 gallons per day for the equivalent population. The equivalent population from the report is 749. The proposed development is 3.78 acres and 5.44% of the Nelson Meadows subdivision. The population equivalent for the site is 40 with an average daily flow rate of 6,800 gallons per day. Water Demand Average Daily Flow Rate = 165 gpd/bed x 19 beds plus 10 gpd/employee x 28 employees = 3,135 gpd plus 280 gpd = 3,415 gpd Maximum Daily Flow Rate = 3,415 x 2.3 = 7,855 gpd Maximum Hour Flow Rate = 3,415 x 3.0 = 10,245 gpd The estimated water demand for the Exceptional Healthcare site is less than the than the design water demand for the site. Fire flow demand will be a maximum of 1,500 gallons per minute per IFC regulations. The water design report for Nelson Meadows also anticipated and modeled fire flows of 1,600 gpm at a minimum pressure of 20 psi for the development in addition to maximum day demands. The proposed facility includes a building with a sprinkler system and aligns with the assumptions and design of the existing system. M O N TANA LICENS E DPROF E SSIONAL E N G INEERDANIEL B. STEWART No. 90803 PE 04/09/25 niel, 1:1