HomeMy WebLinkAbout011 L2.1 SCHEMATIC IRRIGATION PLANPOINT OF CONNECTION
POC IS EXISTING 1" COPPER CITY WATER SERVICE LINE
WITH STATIC PRESSURE OF 110PSI, LOCATION
APPROXIMATE. TAP LINE AND SET WATER METER.
IMPLEMENT A PRESSURE REDUCING VALVE. THIS
SYSTEM IS DESIGNED FOR A 1" WATER METER WITH
65PSI STATIC PRESSURE, 18GPM DESIGN CAPACITY
AND MAXIMUM WORKING PRESSURE OF 45GPM.
CONNECTION POINT
FOR SYSTEM
WINTERIZATION
CONTROLLER
MOUNTED ON
EXTERIOR WALL
RAIN/FREEZE
SENSOR, GUTTER
MOUNTED
PROPOSED 12 UNIT
MULTI-FAMILY
BUILDING
(22,115 SF)
PROPERTY LINE
S88° 37'16"E 134.85'SOUTH 19TH STREETPROPERTY LINES1°25'55"1 142.07'PROPERTY LINE
N88° 39'58"W 134.86'PROPERTY LINES1°26'9"W 142.17'M M
M M M M M M M M M
MM
M
MMM
114"1"
112"
112"
112"
M
1"
1"
1"
114"
1"
RF
C
M
BF
POC
11 4"
1"
1"STATEO F MON
T
A
NALAND
SCAPE A R C H ITECTLICE N S E DLESSA R.
MILLARD
274
SHEET No:
JOB No:
DATE:REVISIONS:SUSTAINABLE
LANDSCAPE ARCHITECTURE
614 S Ferguson Ave, Ste 3
Bozeman, MT 59718
(406) 624-9111
hello@incontour.com
www.incontour.com
PREPARED FOR:inConto u r07/08/2025 625 South 19th Ave, Bozeman, MTThe Pines Phase II22260
Crater Mountain Investments, LLC
1906 BLANCA CT
LOVELAND, CO 80538-5022
(970)-227-9923
0 5 10 20'
SCALE 1" = 10'-0" @ 24" X 36"N
L2.1REV 1: 2025-07-08, PATIO ADJUSTMENTSIRRIGATION PLAN