Loading...
HomeMy WebLinkAboutWater and Sewer Demands DESIGN REPORT WATER AND SANITARY SEWER DEMAND CALCULATIONS TRACT 2A [PLAT F-1-D] Prepared for: Crater Mountain Investments, LLC 1906 Blanca Ct. Loveland CO, 80538-5022 Prepared By: 1091 Stoneridge Drive • Bozeman, Montana • Phone (406) 587-1115 • www.chengineers.com • E-Mail: info@chengineers.com IMEG Project Number: 22003609 C&H Project Number: 210528 February 2023 Design Report - Page 2 of 3 INTRODUCTION The Pines, Phase 2 Site Plan is a proposed apartment development located on Tract 2A of [Plat F- 1-D]. The proposed layout consists of one 12-unit apartment building, a drive access, a parking area, and related stormwater and landscaping areas. The property is located within the City of Bozeman limits and is currently zoned R-4. The property is fronted on one side by South 19th Ave, water and sanitary sewer mains are located within South 19th Ave. and water/sewer services are proposed to serve the development as shown on civil sheet C2.1. Water Distribution System Demands The design parameters used herein are according to the City of Bozeman Design Standards and Specifications Policy (DSSP) dated May 2017. Average Daily Residential Usage = 170 gallons per capita per day Average Population Density = 2.11 persons/dwelling unit Average Day Demand (Peaking Factor = 1.0) Maximum Day Demand (Peaking Factor = 2.3) Peak Hour Demand (Peaking Factor = 3.0) Water Demands (12 dwelling units) Average Day Demand = 12 d.u. x 2.11 persons/d.u. x 170 gpcpd = 4,304 gpd = 2.99 gpm Maximum Day Demand = 2.99 gpm x 2.3 = 6.88 gpm Peak Hour Demand = 2.99 gpm x 3.0 = 8.97 gpm Design Report - Page 3 of 3 Sanitary Sewer Design Load The population estimates of 2.11 people per dwelling unit, and residential flow rate of 89 gpcd used herein are according to the City of Bozeman Design Standards and Specifications. The peaking factor for the design area is determined using the formula provided in the City of Bozeman Design Standards and Specifications. Using the city average of 2.11 persons per household the equivalent population is calculated. Connection: Equivalent Population = (2.11 persons/dwelling unit)(12 units) = 25.32 persons Harmon Formula: Peaking Factor = (18 + P0.5)/(4 + P0.5) where: P = Population in thousands Peaking Factor = (18 + 0.025320.5)/(4 + 0.025320.5) Peaking Factor = 4.366 Assumed infiltration rate = 150 gallons/acre/day = 150 (0.440 acres) = 66 gal/day The peak flow rate is calculated by multiplying the City's design generation rate of 89 gallons per capita per day by the population, multiplying by the peaking factor, and adding the infiltration rate: Peak Flow Rate = 89 gpcpd (25.32 persons) (4.366) + 66 gpd = 9,905 gpd = 6.88 gpm = 0.015 cfs \\Files\Corporate\Offices\Bozeman\Candh\Officedata\CH\21\210528\Design Reports\Sewer\Individual Parts\210528 - Water And Sewer Demands.Docx