Loading...
HomeMy WebLinkAboutLight Fixture_OCL - Vega Sconcep: 314.863.1895 | f: 314.863.3278 | www.ocl.com Designed and Fabricated in St. Louis, Missouri › USA PROJECT NAME: ___________________________________________________________ TYPE: _______________________ QTY: _______________________ Vega ™ SCONCE / OUTDOOR CATALOG CODES SPECIFY CATALOG CODE A B C D E SERIES HANGING SYSTEM SIZE REFLECTOR FINISH VA1 UP OR DOWN ILLUMINATION VA2 UP AND DOWN ILLUMINATION S1SA INDOOR ADA COMPLIANT SCONCE O1OA OUTDOOR ADA COMPLIANT SCONCE 08 NF NARROW FLOOD [24 DEGREE] WF WIDE FLOOD [50 DEGREE] NOTE: CLEAR ACRYLIC DIFFUSER IS STANDARD POWDER COAT FINISHES BKP BLACK BMP BRASS METALLIC BNP BRONZE BTP BLACK TEXTURED GRP GRAPHITE GLP GOLDTASTIC MWP MATTE WHITE SGP STEEL GRAY SMP SILVER METALLIC SWP SKY WHITE WTP WHITE TEXTURED --------F SERIES HANGING SYSTEM SIZE REFLECTOR FINISH LIGHT SOURCE / VOLTAGE CONTROL OPTIONS A B C D E UNV I J • EXCELLENT THERMAL MANAGEMENT IS ACHIEVED THROUGH A DIE-CAST ALUMINUM FIXTURE BODY • INJECTION MOLDED DIFFUSER SEAMLESSLY THREADS INTO FIXTURE BODY; ACRYLIC IS UV STABLE, F1 RATED AND UL-94 HB FLAME RATED • VARYING BEAM SPREAD OPTIONS ARE AVAILABLE: NARROW FLOOD [24 DEGREE] OR WIDE FLOOD [50 DEGREE] • FIELD REPLACEMENT FOR LED ARRAY AND DRIVER • IP66 PROTECTION RATING AND ETL LISTED FOR WET LOCATION (O1OA ONLY) • 3 STEP COLOR BINNING 08 8” WT. 6 LBS 5”4” DM1 MODS, NOTES, & COMMENTS F G H I LIGHT SOURCE VOLTAGE CONTROL OPTIONS LED OUTPUT LED1 LED2 LED3 LED1 LED2 COLOR TEMP (80+ CRI) 27K 30K 35K 40K 27K 30K 35K 40K COLOR TEMP (90+ CRI) 927K 930K 935K 940K 927K 930K 935K 940K UNV 120-277 DM1 0-10V DIMMING 1% NOTE: FIXTURE IS PROVIDED WITH 0-10V DIMMING 1% ULD DAMP LABEL (S1SA ONLY) MOD MODIFIED LUMINAIRE (CONTACT LOCAL REP) SAMPLE CODE: VA1-S1SA-08-NF-WTP–LED1/30K–UNV-DM1 VA1 VA2 This chart was created for a 35K color temp. Multiply by 0.95 for 27k color temp, 0.97 for 30k color temp, and 1.03 for 40k color temp. Values shown for 80+ CRI. For 90+ CRI lumens use 0.85 multiplier. UP TO 90 LM/W This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863 LUMENS AND WATTAGE CHART VA1 VA2 LED1 LUMENS DELIVERED 900 1800 SYSTEM WATTAGE 10 20 LED2 LUMENS DELIVERED 1350 2700 SYSTEM WATTAGE 15 30 LED3 LUMENS DELIVERED 2000 - SYSTEM WATTAGE 25 - 2 of 4 Designed and Fabricated in St. Louis, Missouri › USA p: 314.863.1895 | f: 314.863.3278 | www.ocl.com DIMMING COLOR TEMP LIGHT UP QUANTITY:ORDER #:TYPE: CATEGORY: MOD DESCRIPTION: HIPOTTEST:INITIAL:DATE: GROUND PASS/FAIL: STANDARD -- BACK PLATE SCREWS ANCHOR BODY(BY OTHERS) ANCHOR BODY SCREW(BY OTHERS) 8" 5" VA2 8" 5" VA1 MOUNTING INFORMATION CHART SERIES LUMINAIRESIZE LUMINAIREWEIGHTVA18"6 LBSVA28"6 LBS 4 3 2 1 A B C D E F 3 2 4 1 A B FEDC 31 DEC 20 VEGA OUTDOOR 1 .031 1:3 VA1_VA2-O1OA-SPEC SHEET DESIGNED BY: 1 OF 1 V The drawings and specifications and ideas, designs and arrangements represented on these drawings are and shall remain the property of The Original Cast Lighting (OCL) and no part thereof shall be copied, disclosed, to others or used in conjunction with any work or project other than the specified project for which they have been prepared and developed, without written consent of OCL. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. The Original Cast Lighting - 11902 Lackland Road - St.Louis, Mo 63146 - ph 314-863-1895 - fx 314-863-3278 - www.OCL.com ASSEMBLY NUMBER: DATE: SCALE: FILE NAME: ASSEMBLY DESCRIPTION: VA1_VA2-O1OA-SPEC SHEET DIM ANGLE UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN INCHESTOLERANCE VALUES REV.REV BY:DATE:DESCRIPTION: SCALE IS FOR REFERENCE ONLYDO NOT SCALE DRAWING DRAWING SIZE:B VINITIAL RELEASE 31 DEC 20 DIMMING COLOR TEMP LIGHT UP QUANTITY:ORDER #:TYPE: CATEGORY: MOD DESCRIPTION: HIPOTTEST:INITIAL:DATE: GROUND PASS/FAIL: STANDARD -- 8" 5" VA1 8" 5" VA2 SCREWS BACK PLATE SCREW (BY OTHERS) J-BOX(BY OTHERS) MOUNTING INFORMATION CHARTSERIESLUMINAIRESIZELUMINAIREWEIGHTVA18"5.5 LBSVA28"5.5 LBS 4 3 2 1 A B C D E F 3 2 4 1 A B FEDC 31 DEC 20 VEGA SCONCE 1 .031 1:3 VA1_VA2-S1SA-SPEC SHEET DESIGNED BY: 1 OF 1 V The drawings and specifications and ideas, designs and arrangements represented on these drawings are and shall remain the property of The Original Cast Lighting (OCL) and no part thereof shall be copied, disclosed, to others or used in conjunction with any work or project other than the specified project for which they have been prepared and developed, without written consent of OCL. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. The Original Cast Lighting - 11902 Lackland Road - St.Louis, Mo 63146 - ph 314-863-1895 - fx 314-863-3278 - www.OCL.com ASSEMBLY NUMBER: DATE: SCALE: FILE NAME: ASSEMBLY DESCRIPTION: VA1_VA2-S1SA-SPEC SHEET DIM ANGLE UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN INCHESTOLERANCE VALUES REV.REV BY:DATE:DESCRIPTION: SCALE IS FOR REFERENCE ONLYDO NOT SCALE DRAWING DRAWING SIZE:B V-INITIAL RELEASE 31 DEC 20 S1SA INDOOR ADA COMPLIANT SCONCE O1OA OUTDOOR ADA COMPLIANT SCONCE MOUNTING INFORMATION CHART LUMINAIRE HEIGHT LUMINAIRE WEIGHT MOUNTING POINTS 8”6 LBS 1 MOUNTING INFORMATION CHART LUMINAIRE HEIGHT LUMINAIRE WEIGHT MOUNTING POINTS 8”6 LBS 1 SCREW (BY OTHERS) HANGING SYSTEM BACK PLATE J-BOX (BY OTHERS) SCREW (X2) SCREW (X2) SCREW (BY OTHERS) BACK PLATE ANCHOR BODY (BY OTHERS) 3 of 4 Designed and Fabricated in St. Louis, Missouri › USA p: 314.863.1895 | f: 314.863.3278 | www.ocl.com VA1 NARROW FLOOD VA1 WIDE FLOOD VA2NARROW FLOOD VA2WIDE FLOOD ZONE LUMENS % OF LUMINAIRE LUMENS % OF LUMINAIRE LUMENS % OF LUMINAIRE LUMENS % OF LUMINAIRE 0-30 1275 70.5%1440 74%1000 30%1066 38% 0-60 1795 99.5%1955 99.5%1400 53%1460 53% 0-90 1810 100%1965 100%1415 54%1480 53% 90-180 0 0%0-0%1220 46%1300 47% 0-180 1810 100%1965 100%2630 100%2780 100% PHOTOMETRY: FIXTURE: VAX-0101A-08-NF-BTP COLOR TEMP #: 3500K EFFICACY: 80 LM/W TEST REPORT: TEST NO. 17814.0 For all available IES files, please visit our website at ocl.com. 90˚90˚ 0˚ 180˚ 733 733 1467 1467 2200 2200 2933 2933 3667 3667 4400 440 90˚90˚ 0˚ 180˚ 467 467 933 933 1400 1400 1867 1867 2333 2333 2800 2800 90˚90˚ 0˚ 180˚ 350 350 700 700 1050 1050 1400 1400 1750 1750 2100 2100 This chart was created for a 35K color temp. Multiply by 0.95 for 27k color temp, 0.97 for 30k color temp, and 1.03 for 40k color temp. Values shown for 80+ CRI. For 90+ CRI lumens use 0.85 multiplier. LIGHT SOURCE VA1NARROW FLOOD VA1WIDE FLOOD VA2NARROW FLOOD UP & DOWN VA2WIDE FLOOD UP & DOWN 90˚90˚ 0˚ 180˚ 617 617 1233 1850 1850 2467 2467 3083 3083 3700 3700 1233 FINISH SOLID POWDER COAT FINISHES: METALLIC POWDER COAT FINISHES: TEXTURED POWDER COAT FINISHES: SWP SKY WHITE BKP BLACK MWP MATTE WHITE SMP SILVER BMP BRASS GLP GOLD TASTIC SGP STEEL GRAY BNP BRONZE BTP BLACK TEXTURED WTP WHITE TEXTURED GRP GRAPHITE RAL®, Pantone®, or custom finishes are also available. These colors are for reference only. Please be aware that colors may vary per monitor. Contact your local rep for finish samples or with any questions. LUMENS AND WATTAGE CHART VA1 VA2 LED1 LUMENS DELIVERED 900 1800 SYSTEM WATTAGE 10 20 LED2 LUMENS DELIVERED 1350 2700 SYSTEM WATTAGE 15 30 LED3 LUMENS DELIVERED 2000 - SYSTEM WATTAGE 25 - STANDARD COLOR TEMPERATURE OPTIONS CRI (RA) 2700K 80+90+ 3000K 80+90+ 3500K 80+90+ 4000K 80+90+ 4 of 4 Designed and Fabricated in St. Louis, Missouri › USA p: 314.863.1895 | f: 314.863.3278 | www.ocl.com The drawings and specifications and ideas, designs and arrangements represented on these drawings are and shall remain the property of The Original Cast Lighting (OCL Architectural Lighting) and no part thereof shall be copied, disclosed, to others or used in conjunction with any work or project other than the specified project for which they have been prepared and developed, without written consent of OCL. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. All specifications and information subject to change without notice. CONTROL DM1 0-10V DIMMING DOWN TO 1% • 0-10V DIMMING • 1% MINIMUM DIMMING LEVEL • ELECTRONIC DRIVER • POWER FACTOR >0.9 • THD <20% • MIN AMBIENT OPERATING TEMPERATURE = -31˚F • FIELD REPLACEABLE OPTIONS SPECIFICATIONS CONSTRUCTION • FIXTURE IS CAST AND MACHINED ALUMINUM • HARDWARE IS ZINC PLATED OR STAINLESS STEEL LENSING • CLEAR ACRYLIC LENS STANDARD ELECTRICAL • DIMMING ELECTRONIC DRIVER(S), COMES STANDARD WITH 0-10V DOWN TO 10% • 0-10V DOWN TO 0.1% AND LUTRON ECOSYSTEM (LDE1) 1% ALSO AVAILABLE AS MODIFICATION • BRIDGELUX COB • LUMINAIRE CONNECTS TO BUILDING SUPPLY (120V-277V 50/60HZ) UNLESS DRIVERS ARE REMOTE LISTING • ETL LISTED TO UL 1598 FOR DRY LOCATIONS; DAMP LOCATION LISTED IS OPTION WARRANTY • 5 YEAR; ALL ELECTRICAL COMPONENTS RETAIN THE MANUFACTURER’S WARRANTY ULD DAMP LABEL LUMINAIRE • MAY BE USED IN AN OUTDOOR AREA THAT IS PROTECTED FROM DIRECT CONTACT WITH WIND, RAIN, SNOW OR EXCESSIVE MOISTURE MOD MODIFIED LUMINAIRE • LUMINAIRE IS MODIFIED FROM STANDARD OPTIONS; CONTACT LOCAL REP FOR MORE INFORMATION