Loading...
HomeMy WebLinkAbout026 C 4.10 STORM DETAILS1SCALE: N.T.S.2SCALE: N.T.S.CIRCULAR STORM DRAIN INLET24" x 36" RECTANGULAR STORM DRAIN INLETO.D.AS REQUIRED INLETCASTINGOPENING24" SQUARE OPENING48" R.C.P. ASTM C-76 CLASS 2BLOCK OUT FORINLET/OUTLETPIPES9" SUMP6" PRECAST BASE6"FLAT TOPAS REQUIRED INLETCASTINGOPENING24"BLOCK OUT FORINLET PIPE9" SUMP6" PRECAST BASE6"FLAT TOPI.D.PLAN VIEWPLAN VIEWSECTION VIEWSECTION VIEWO.D.I.D.4" WALLTBC ELEV.TOP OF CONC.ELEV.TBC ELEV.TOP OF CONC.ELEV.PARTMANUFACTURERFRAMEEAST JORDANIRON WORKSMATERIALRATINGIRONTRAFFIC RATEDCOVEREAST JORDANIRON WORKSIRONTRAFFIC RATEDPRODUCT #3772-Z13771-C1NOTES:1.COVER TO BE STAMPED "STORM DRAIN" WITH CITY OF BOZEMAN LOGO2.ASSURE THAT ALL COVERS HAVE TWO PICK HOLES, 1”MINIMUM, 1 ¼ ” MAXIMUMDIAMETERPARTMANUFACTURERFRAMEEAST JORDANIRON WORKSMATERIALRATINGIRONTRAFFIC RATEDGRATEEAST JORDANIRON WORKSIRONTRAFFIC RATEDBACKEAST JORDANIRON WORKSIRONTRAFFIC RATEDPRODUCT #007030-Z1007030-M6 ORM7 FOR SAG007030-T1SAFL BAFFLESTORM MANHOLE NOTESSCALE: N.T.S.SCALE: N.T.S.RIM ELEV. = FLOWLINERIM ELEV. = FLOWLINENOTES:1.INLET CASTINGS SHALL HAVE A LOGO CAST INTO THE CURB PIECE STATING“DUMP NO WASTE, DRAINS TO WATERWAYS”STORM MANHOLESSTORM DRAIN INLETSSCALE: N.T.S.CONTRACTOR TOGROUT ANNULARSPACES OR USESUPPLIED GASKETSCONTRACTOR TOGROUT ANNULARSPACES OR USESUPPLIED GASKETS9"SUMP6" BASEGRADERINGS ASNEEDEDPLAN VIEWSECTION VIEW24"Ø OPENINGSTORMSEWEREJIW-IFCOMADEINUSACAST IRON 4" OR 7"FRAME AND COVERCONTRACTOR TOGROUT ANNULARSPACES OR USESUPPLIED GASKETS3TYPICAL STORM MANHOLESCALE: N.T.S.DIAMETER VARIESSEE SCHEDULERIM ELEV.STORMWATER STRUCTURE SCHEDULES 4Ө (DEG.)ӨRev C (07-24-2019)#8663466B2 - US #8715507B2 - US #9506237B2 - CA #27422075BASIN A STORMWATER STRUCTURE SCHEDULENAMEMH-11 AREA DRAINMH 1 OUTLET STRUCTUREMH 2 WITH SAFL BAFFLEMH 4 WITH SAFL BAFFLEMH 9SDI 1SDI 2SDI 3SDI 4SDI 7SDI 12SDI 13SDI 14SDI 15SDI 16TYPE48" MANHOLE48" MANHOLE60" MANHOLE60" MANHOLE60" MANHOLETYPE 2TYPE 2TYPE 2TYPE 2TYPE 2TYPE 2TYPE 2TYPE 2TYPE 2TYPE 2GRATEMH LIDMH LIDMH LIDMH LIDMH LIDTYPE LTYPE LTYPE LTYPE LTYPE LTYPE LTYPE LTYPE LTYPE LTYPE LRIM ELEV4711.504710.644710.464708.164712.124710.134711.004711.734710.174706.954710.174710.954711.444711.634709.70PIPES INE 18"Ø INV IN =4707.40E 18"Ø INV IN =4707.19NW 15"Ø INV IN =4704.05W 18"Ø INV IN =4707.50E 18"Ø INV IN =4707.50E 18"Ø INV IN =4707.50E 18"Ø INV IN =4707.50N 18"Ø INV IN =4707.50S 18"Ø INV IN =4707.50E 18"Ø INV IN =4707.50E 18"Ø INV IN =4707.50W 12"Ø INV IN =4707.50E 18"Ø INV IN =4707.50PIPES OUTS 18"Ø INV OUT =4707.56W 18"Ø INV OUT =4707.40W 18"Ø INV OUT =4707.19N 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50SE 15"Ø INV OUT =4704.58W 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50W 18"Ø INV OUT =4707.50E 18"Ø INV OUT =4707.50E 12"Ø INV OUT =4707.80BASIN B STORMWATER STRUCTURE SCHEDULENAMEMH 3 WITH SAFL BAFFLESDI 5SDI 6TYPE48" MANHOLETYPE 2TYPE 2GRATEMH LIDTYPE LTYPE LRIM ELEV4707.894707.804708.03PIPES INS 15"Ø INV IN =4704.05E 15"Ø INV IN =4704.15PIPES OUTW 15"Ø INV OUT =4705.08N 15"Ø INV OUT =4704.15BASIN C STORMWATER STRUCTURE SCHEDULENAMEMH-5SDI 8SDI 9SDI 10SDI 11 WITH SAFL BAFFLETYPE48" MANHOLETYPE 2TYPE 2TYPE 2TYPE 2GRATEMH LIDTYPE LTYPE LTYPE LTYPE LRIM ELEV4707.694705.374704.774704.224703.77PIPES INE 15"Ø INV IN =4701.91E 15"Ø INV IN =4701.28S 15"Ø INV IN =4701.61E 15"Ø INV IN =4700.53PIPES OUTN 15"Ø INV OUT =4704.05W 15"Ø INV OUT =4702.54W 15"Ø INV OUT =4701.91W 15"Ø INV OUT =4701.28S 15"Ø INV OUT =4700.50C4.10AS NOTEDHEC Dec 04, 2024 - 5:02pmCAD FILE: M:\213601\Drawings\Construction Drawings\4.10-STRM DETAILS.dwg REVISIONSDATEPROJECT NUMBERHYALITE Engineers, PLLC161 W. HALEY SPRINGSBozeman, MT 59715Tel: (406) 587.2781w w w . hyaliteeng. comFax: (406) 522.92252018DAVIS LANE BOZEMAN MT12/4/2024213601COB SITE PLAN - 22x34 ORIGINALSSCALESHEET TITLEDESIGN BY6590 DAVIS LANEBOZEMAN, MT, 59718PROPERTYROAD STE. 101STORM DETAILSBV