Loading...
HomeMy WebLinkAboutTechnical Specs SIDINGHardie® Plank Lap Siding FEBRUARY 2024 P1 Submittal Form 01 The JHInsite® Team James Hardie Building Products www.jhinsite.com HARDIE® PLANK LAP SIDING Submitted to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Project Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Submitted by: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HZ5® Product Zone HZ10® Product Zone Product Width: 5-1/4in 6-1/4in 7-1/4in 8in 8-1/4in 9-1/4in 12in Product Finish: Primed ColorPlus® Technology Product Texture: Smooth Select Cedarmill® Colonial Roughsawn® Colonial Smooth® Rustic Cedar Hardie® Plank Lap Siding Specification Sheet 01 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products, Inc. The products are manufactured at the following locations, with quality control inspections by ICC-ES: • Cleburne, Texas • Peru, Illinois • Plant City, Florida • Pulaski, Virginia • Reno, Nevada • Tacoma, Washington • Waxahachie, Texas • Fontana, California • Prattville, Alabama • Summerville, South Carolina Compliance with the following codes • 2006 thru 2021 International Building Code (IBC) • 2006 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to ICC-ES ESR-2290 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resists damage from pests • Sustainable Use Hardie® fiber- cement lap siding is used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III and IV construction (IBC) Description Hardie® Plank lap siding is a single- faced, cellulose fiber- reinforced cement (fiber- cement) product. Hardie® Plank lap siding complies with ASTM C1186, as Grade II, Type A; has a flame- spread index of 0 and a smoke- developed index of 5 when tested in accordance with ASTM E84; and is classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (in)Length Thickness (in) Hardie® Plank lap siding*5- 1/4, 6- 1/4, 7- 1/4, 8, 8- 1/4, 9- 1/4, 12 12 feet 5/16 * HZ5: 9-1/4, 12 only available primed HZ10: 5-1/4, 9-1/4, 12 only available primed. Weight2.31 lbs. per square foot Texture & Finish Hardie® Plank lap siding comes in a variety of textures and finishes. The product is available in smooth or wood grain texture. Additional textures are available on a regional basis. Finish options are primed for field paint, or factory finished with ColorPlus® Technology. Color availability varies by region. Engineered for Climate® Hardie® Plank lap siding is engineered for performance to specific weather conditions by climate zones as identified by the following map. SPECIFICATION SHEET 01 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.04 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported 83 Water Absorption, % by mass ASTM C1185 As reported 36 Water Tightness ASTM C1185 Physical Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass THERMALThermal Conductivity Actual Thermal Conductivity Thermal Resistance Actual Thermal Resistance ASTM C177 (BTU/(hr·ft°F))/inch (Keff) R=1/ Keff (R) As reported 2.07 6.62 0.48 0.15 DURABILITYWarm Water Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Physical Observations Mass Loss, % Freeze/Thaw, % strength retention No visible cracks or structural alteration <_ 3.0% >_ 80% Pass UV Accelerated Weathering Test ASTM G23 Physical Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Noncombustibility ASTM E136 Noncombustible Pass/fail Pass Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1 Note 1: listed on Warnock Hersey and ESR 2290 Installation Install Hardie® Plank lap siding in accordance with: • Hardie® Plank lap siding installation instructions • ICC-ES ESR 2290 • Requirements of authorities having jursidiction Warranty Hardie® Plank lap siding: 30-year, Non-Prorated, Limited Warranty ColorPlus® Technology: 15-year Limited Finish Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Compliance Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800)426-4051 SS2001 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Panel vertical siding P1 Submittal Form 02 The JHInsite® Team James Hardie Building Products www.jhinsite.com HARDIE® PANEL VERTICAL SIDING Submitted to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Project Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Submitted by: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HZ5® Product Zone HZ10® Product Zone Product Width: 4x8ft 4x9ft 4x10ft 16inx12ft Product Finish: Primed ColorPlus® Technology Product Texture: Smooth Select Cedarmill© Sierra 8 Stucco Hardie® Panel vertical siding Specification Sheet 02 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by ICC-ES: • Cleburne, Texas • Peru, Illinois • Plant City, Florida • Pulaski, Virginia • Reno, Nevada • Tacoma, Washington • Waxahachie, Texas • Fontana, California • Prattville, Alabama • Summerville, South Carolina Compliance with the following codes • 2006 thru 2021 International Building Code (IBC) • 2006 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to the ESR-1844 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage • Sustainable caused by pests Use James Hardie fiber- cement panels are used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III and IV construction (IBC). Description Hardie® Panel vertical siding is a single- faced, cellulose fiber- reinforced cement (fiber- cement) product. Hardie® Panel vertical siding complies with ASTM C1186, as Grade II, Type A; has a flame- spread index of 0 and a smoke- developed index of 5 when tested in accordance with ASTM E84; and is classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (inches)Length (feet)Thickness (inches) Hardie® Panel vertical siding 48 8, 9*, 10 5/16 * Size not available in ColorPlus® Technology, primed only. Weight: 2.40 lbs. per square foot Texture & Finish Hardie® Panel vertical siding comes in a variety of textures and finishes. The product is available in smooth, wood grain, Sierra 8, or stucco. Finish options are primed for field paint, or factory finished with ColorPlus® Technology. Color availability varies by region. Engineered for Climate® Hardie® Panel vertical siding is engineered for performance to specific weather conditions by climate zones as identified by the following map. FEBRUARY 2024 SPECIFICATION SHEET 02 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.04 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported 83 Water Absorption, % by mass ASTM C1185 As reported 36 Water Tightness ASTM C1185 Physical Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass THERMALThermal Conductivity Actual Thermal Conductivity Thermal Resistance Actual Thermal Resistance ASTM C177 (BTU/(hr·ft°F))/inch (Keff) R=1/ Keff (R) As reported 2.07 6.62 0.48 0.15 DURABILITYWarm Water Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Physical Observations Mass Loss, % Freeze/Thaw, % strength retention No visible cracks or structural alteration <_ 3.0% >_ 80% Pass UV Accelerated Weathering Test ASTM G23 Physical Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Noncombustibility ASTM E136 Noncombustible Pass/fail Pass Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1 Note 1: listed on Warnock Hersey and ESR 1844 Installation Install Hardie® Panel vertical siding in accordance with: • Hardie® Panel vertical siding installation instructions • ICC-ES ESR-1844 • Requirements of authorities having jurisdiction Warranty Hardie® Panel vertical siding: 30-year, Non-Prorated, Limited Warranty ColorPlus® Technology: 15-year Limited Finish Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Compliance Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800)426-4051 SS2002 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Shingle Siding P1 Submittal Form 03 The JHInsite® Team James Hardie Building Products www.jhinsite.com HARDIE® SHINGLE SIDING Submitted to: ........................................ Project Name: ....................................... Submitted by:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HZ5® Product Zone HZ10® Product Zone Product : Straight Edge Panel Staggered Edge Panel Half Round Panel Individual Product Finish: Primed ColorPlus® Technology Product Texture: Select Cedarmill® Hardie® Shingle Siding Specification Sheet 03 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by ICC-ES: • Cleburne, Texas • Peru, Illinois • Plant City, Florida • Pulaski, Virginia • Reno, Nevada • Tacoma, Washington • Waxahachie, Texas • Fontana, California • Prattville, Alabama • Summerville, South Carolina Compliance with the following codes • 2006 thru 2021 International Building Code (IBC) • 2006 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to ICC-ES ESR-2290 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage • Sustainable caused by pests Use James Hardie fiber- cement cladding shingles are used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III and IV construction (IBC). Description Hardie® Shingle siding is a single- faced, cellulose fiber- reinforced cement (fiber- cement) product. Hardie® Shingle siding complies with ASTM C1186, as Grade II, Type A; has a flame- spread index of 0 and a smoke- developed index of 5 when tested in accordance with ASTM E84; and is classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (in)Height (in)Thickness (in) Shingle Panel 5 inch exposure (Straight edge)48 14 1/4 Shingle Panel 6 inch Exposure (Staggered Edge)48 15-1/4 1/4 Shingle Panel 7 inch exposure (Straight Edge & Half Round)48 15-1/4 1/4 Individual shingles 5 inch exposure 3-1/2, 4-1/2, 5-1/2, 7, 8-3/4 14 1/4 Individual shingles 7 inch exposure 4-3/16, 5-1/2, 6-3/4, 7-1/4, 10 15-1/4 1/4 Weight: 2.12 lbs. per square foot Texture & Finish Hardie® Shingle siding is available in wood grain texture. Finish options are primed for field paint, or factory finished with ColorPlus® Technology. Color and exposure availability varies by region. Engineered for Climate® Hardie® Shingle siding is engineered for performance to specific weather conditions by climate zones as identified by the following map. FEBRUARY 2024 SS2003 02/24 PAGE 1 OF 2 SPECIFICATION SHEET 03 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4in ± 0.5% or ± 1/4 in ± 0.04 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported 83 Water Absorption, % by mass ASTM C1185 As reported 36 Water Tightness ASTM C1185 Physical Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass THERMALThermal Conductivity Actual Thermal Conductivity Thermal Resistance Actual Thermal Resistance ASTM C177 (BTU/(hr·ft°F))/inch (Keff) R=1/ Keff (R) As reported 2.07 6.62 0.48 0.15 DURABILITYWarm Water Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Physical Observations Mass Loss, % Freeze/Thaw, % strength retention No visible cracks or structural alteration <_ 3.0% >_ 80% Pass UV Accelerated Weathering Test ASTM G23 Physical Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Noncombustibility ASTM E136 Noncombustible Pass/fail Pass Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1 Note 1: listed on Warnock Hersey Installation Install Hardie® Shingle siding in accordance with: • Hardie® Shingle siding installation instructions • ICC-ES ESR 2290 • Requirements of authorities having jursidiction Warranty Hardie® Shingle siding: 30-year, Non-Prorated, Limited Warranty ColorPlus® Technology: 15-year Limited Finish Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Compliance Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800)426-4051 SS2003 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Artisan Siding with Lock Joint System FEBRUARY 2024 SUBMITTAL FORM 05 The JHInsite® Team James Hardie Building Products www.jameshardiepros.com Submitted to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Project Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Submitted by: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATION SHEET 05 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by Intertek: • Reno, Nevada • Prattville, Alabama Compliance with the following codes • 2024, 2021, 2015, 2012, 2009 and 2006 International Building Code® (IBC) • 2024, 2021, 2015, 2012, 2009 and 2006 International Residential Code® (IRC) Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage caused by pests Use Hardie® Artisan Siding with Lock Joint System is used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III and IV construction (IBC). Description Hardie® Artisan Siding with Lock Joint System is a single-faced, cellulose fiber- reinforced cement (fiber-cement) product. Hardie® Artisan Siding complies with ASTM C1186, as Grade II, Type A; has a flame-spread index of 0 and a smoke-developed index of 5 when tested in accordance with ASTM E84; and is classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (inches)Exposure (inches)Length (feet)Thickness (inches) V-Groove 8-¼7 12 5/8 Shiplap 10-¼9 12 5/8 Square Channel 10-¼9 12 5/8 Panel Texture & Finish Hardie® Artisan Siding with Lock Joint System comes in a smooth finish. Finish comes primed for field paint. Engineered for Climate® Hardie® Artisan Siding with Lock Joint System is engineered for performance to specific weather conditions by climate zones as identified by the following map. HZ10® Product Zone HZ5® Product Zone SS2005 PAGE 1 OF 2 Joint Style: V- Groove Square Channel Shiplap SPECIFICATION SHEET 05 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.05 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported <75 Water Tightness ASTM C1185 Visual Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass DURABILITYWarm Water Resistance, Observations ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Visual Observations Freeze/Thaw, % strength retention No visible cracks or structural alteration >_ 80%Pass UV Accelerated Weathering Test ASTM G23 Visual Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Non-combustibility ASTM E136 Non-combustible Pass/fail Pass Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1 Installation Install Hardie® Artisan Siding with Lock Joint System in accordance with: • Hardie® Artisan Siding with Lock Joint System Installation Instructions • Hardie® Artisan Siding with Lock Joint System Technical Data Sheet • Requirements of authorities having jurisdiction Warranty Hardie® Artisan Siding with Lock Joint System: 30-year, Non-Prorated, Limited Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Materials Compliant Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800) 426-4051 SS2005 2/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Soffit Panels FEBRUARY 2024 P1 Submittal Form 06 The JHInsite® Team James Hardie Building Products www.jhinsite.com Submitted to: ........................................ Project Name: ....................................... Submitted by:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HZ5® Product Zone HZ10® Product Zone Hardie® Soffit Panels Specification Sheet 06 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by ICC-ES: • Tacoma, Washington • Pulaski, Virginia • Waxahachie, Texas • Peru, Illinois • Plant City, Florida Compliance with the following codes • 2009 thru 2021 International Building Code (IBC) • 2009 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to the ESR-2273 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage • Sustainable caused by pests Use Hardie® Soffit panels are used as exterior soffit covering of buildings. Description Hardie® Soffit panels are single-faced, cellulose fiber-reinforced cement (fiber- cement) sheets manufactured by the Hatschek process and cured by high- pressure steam autoclaving. The exterior soffit panels are identified as Hardie® Soffit panels and my be vented or unvented. Available Sizes Product Width (inches)Length (inches)Thickness (inches) Hardie® Soffit Panels 12, 16, 24, 48 96, 144 1/4 Weight: 2.12 lbs. per square foot Texture & Finish Soffit panels are available with either a woodgrain texture or a smooth unsanded surface. The exterior soffit products may be supplied primed for field paint or factory finished with Colorplus® Technology. (color varies by region) Features Hardie® vented Hardie® Soffit Panels achieve a net free ventilation (NFV) of 5 sq in per linear ft. Hardie® Soffit VentedPlus® panels provide 12.6 square inches of net free ventilation per lineal foot. (availability is limited) Engineered for Climate® Hardie® Soffit Panels are engineered for performance to specific weather conditions by climate zones as identified by the following map. Product Width (inches)Length (inches)Texture Finish Hardie® Soffit Panels - Vented 12 144 Smooth Cedamill ColorPlus® Technology Primed 16 144 24 96 Hardie® Soffit Panels - Non-Vented 12 144 Smooth Cedamill ColorPlus® Technology Primed 16 144 24 96 48 96 SS2004 PAGE 1 OF 2 SPECIFICATION SHEET 06 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.04 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported <75 Water Tightness ASTM C1185 Visual Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass DURABILITYWarm Water Resistance, Observations ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Visual Observations Freeze/Thaw, % strength retention No visible cracks or structural alteration >_ 80%Pass UV Accelerated Weathering Test ASTM G23 Visual Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Non-combustibility ASTM E136 Non-combustible Pass/fail Pass Installation Install Hardie® Soffit Panels in accordance with: • Hardie® Soffit Panels Installation Iinstructions • ICC-ES ESR-2273 • Requirements of authorities having jurisdiction Warranty Hardie® Soffit Panels: 30-year, Non-Prorated, Limited Warranty ColorPlus® Technology: 15-year Limited Finish Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Compliance Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800)426-4051 SS2004 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Artisan Lap Siding FEBRUARY 2024 SUBMITTAL FORM 07 The JH Insite Team James Hardie Building Products www.jameshardiepros.com Submitted to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Project Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Submitted by: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATION SHEET 07 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by Intertek: • Reno, Nevada • Prattville, AL Compliance with the following codes • 2006 thru 2021 International Building Code (IBC) • 2006 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to ICC-ES ESR-2290 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage caused by pests Use Hardie® Artisan Lap Siding is used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III and IV construction (IBC). Description Hardie® Artisan Lap Siding is a single- faced, cellulose fiber- reinforced cement (fiber- cement) product. Hardie® Artisan Siding complies with ASTM C1186, as Grade II, Type A; has a flame- spread index of 0 and a smoke- developed index of 5 when tested in accordance with ASTM E84; and is classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (inches)Length (feet)Thickness (inches) Lap 7-¼, 8-¼12 5/8 Panel Texture & Finish Hardie® Artisan Lap Siding comes in a smooth finish. Finish comes primed for field paint. Engineered for Climate® Hardie® Artisan Lap Siding is engineered for performance to specific weather conditions by climate zones as identified by the following map. BeadedLapLap HZ10® Product Zone HZ5® Product Zone Product Width: 7-¼in 8-¼in Product Finish: Primed Product Texture: Smooth SS2007 PAGE 1 OF 2 SPECIFICATION SHEET 07 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.05 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported <75 Water Tightness ASTM C1185 Visual Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass DURABILITYWarm Water Resistance, Observations ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Visual Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Visual Observations Freeze/Thaw, % strength retention No visible cracks or structural alteration >_ 80%Pass UV Accelerated Weathering Test ASTM G23 Visual Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Non-combustibility ASTM E136 Non-combustible Pass/fail Pass Installation Install Hardie® Artisan Lap Siding products in accordance with: • Hardie® Artisan Lap Siding Installation Instructions • ICC-ES ESR-2290 • Requirements of local authorities having jurisdiction Warranty Hardie® Artisan Lap Siding: 30-year, Non-Prorated, Limited Warranty Sustainable Design Contribution • Regionally sourced content- varies by project location • Avoidance of certain chemicals or Red List Materials Compliant Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800) 426-4051 SS2007 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance. Hardie® Architectural Panel P1 Submittal Form 08 The JHInsite® Team James Hardie Building Products Inc. www.jhinsite.com HARDIE® ARCHITECTURAL PANEL Submitted to: ........................................ Project Name: ....................................... Submitted by:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product: Fine Sand Mounded Sand Fine Sand-Grooved Sea Grass Product Zone: HZ5® HZ10® Product Width: 4ftx8ft 4ftx10ft 4ftx12ft Product Finish: Primed ColorPlus® Technology finish (Limited Availability) Hardie® Architectural Panel Specification Sheet 08 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION I SECTION: 07 46 46 FIBER CEMENT SIDING Manufacturer James Hardie Building Products Inc. The products are manufactured at the following locations, with quality control inspections by Intertek: • Reno, Nevada Compliance with the following codes • 2006 thru 2021 International Building Code (IBC) • 2006 thru 2021 International Residential Code (IRC) For more information about other compliances and applicable uses, refer to the ESR-1844 Features • Noncombustible • Weather Resistant-Engineered for Climate® • Dimensionally Stable • Impact resistant • Resistant to damage • Sustainable caused by pests • Machined shiplap edges • Machined face grooves* *Hardie® Architectural Panel - Fine Sand-Grooved only Use Hardie® fiber cement panels are used as exterior wall covering. The product complies with IBC Section 1403.9 and IRC Section R703.10. The product may be used on exterior walls of buildings of Type I, II, III, IV and V construction. Description Hardie® Architectural Panel are single- faced, cellulose fiber- reinforced cement (fiber cement) product. Hardie® Architectural Panel comply with ASTM C1186, as Grade II, Type A; have a flame- spread index of 0 and a smoke- developed index of 5 when tested in accordance with ASTM E84; and are classified as noncombustible when tested in accordance with ASTM E136. Available Sizes Product Width (inches)Length (feet)Thickness (inches) Hardie® Architectural Panel Fine Sand 48 8, 10, 12 5/16 Hardie® Architectural Panel Mounded Sand 48 8, 10, 12 5/16 Hardie® Architectural Panel Fine Sand-Grooved 48 8, 10, 12 5/16 * Product not available in ColorPlus® Technology finishes, primed only. Weight: 2.49 lbs. per square foot Texture & Finish Hardie® Architectural Panel comes in two distinct textures and a variety of finishes. The product is available in Fine Sand or Mounded Sand textures, where the Fine Sand-Groove is available only in Smooth Sand texture. Finish options are primed for field paint, or factory finished with ColorPlus® Technology finishes. Color availability varies by region. Engineered for Climate® Hardie® Architectural Panel is engineered for performance in specific weather conditions by climate zones as identified by the following map. FEBRUARY 2024 SS2008 2/24 PAGE 1 OF 2 SPECIFICATION SHEET 08 FEBRUARY 2024 Performance Properties General Property Test Method Unit or Characteristic Requirement Result PHYSICAL ATTRIBUTESDimensional Tolerances ASTM C1185 Length Width Thickness Squareness Edge Straightness ± 0.5% or ± 1/4 in ± 0.5% or ± 1/4 in ± 0.04 in ∆ in diagonals ≤ 1/32 in/ft of sheet length. Opposite sheet sides shall not vary in length by more than 1/32 in/ft ≤ 1/32 in/ft of length Pass Density, lb/ft3 ASTM C1185 As reported 83 Water Absorption, % by mass ASTM C1185 As reported 36 Water Tightness ASTM C1185 Physical Observations No drop formation Pass Flexural Strength ASTM C1185 Wet conditioned, psi Equilibrium conditioned, psi >1015 psi >1450 psi Pass THERMALThermal Conductivity Actual Thermal Conductivity Thermal Resistance Actual Thermal Resistance ASTM C177 (BTU/(hr·ft°F))/inch (Keff) R=1/ Keff (R) As reported 2.07 6.62 0.48 0.15 DURABILITYWarm Water Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Heat/Rain Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Freeze/Thaw Resistance ASTM C1185 Physical Observations Mass Loss, % Freeze/Thaw, % strength retention No visible cracks or structural alteration <_ 3.0% >_ 80% Pass UV Accelerated Weathering Test ASTM G23 Physical Observations No cracking, checking, or crazing Pass FIRE CHARACTERISTICSSurface Burning Characteristics ASTM E84 Flame Spread Index (FSI) Smoke Developed Index (SDI) Fuel Contributed 0 <_ 5 0 NFPA Class Uniform Building Code Class International Building Code® class As reported A 1 A Noncombustibility ASTM E136 Noncombustible Pass/fail Pass Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1 Note 1: See Intertek Listing or ICC-ES ESR-1844 for rated assemblies Installation Install Hardie® Architectural Panel in accordance with: • Hardie® Architectural Panel installation instructions • ICC-ES ESR-1844 • Requirements of authorities having jurisdiction Warranty Hardie® Architectural Panel: 30-year, Non-Prorated, Limited Warranty ColorPlus® Technology: 15-year Limited Finish Warranty Sustainable Design Contribution • Regionally sourced content- vary by project location • LEED Avoidance of certain chemicals or LBC Red List Compliance Detailed product information for LEED projects, or other state or regional sustainability programs is available through James Hardie Technical Services. Storage and Handling Store flat and keep dry and covered prior to installation. Technical Services Contact James Hardie Technical Services online at JamesHardie.com, or by phone at (800) 426-4051 SS2008 02/24 PAGE 2 OF 2 Product warranties, safety information and additional installation information are available at jameshardiepros.com 1 866 442 7343 | www.jameshardie.com © 2024 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. The International Building Code and International Residential Code trademarks are registered trademarks of International Code Council, Inc. IMPORTANT: Failure to install and finish this product in accordance with applicable building codes and James Hardie written application instructions may affect system performance, violate local building codes, void the product-only warranty and lead to personal injury. DESIGN ADVICE: Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance.