Loading...
HomeMy WebLinkAbout053_S.01_RetainingWallGeneralNotesM BENJAMIN D. WARDELL O N T A NA PROF ESSIONAL E NGINEERLICE N S E DNO. 13302 PEREVISIONSREVDATEDESCRIPTIONBY 406-656-6399222 N. 32nd Street #700Billings, Montana 59101WWW.DOWL.COMPROJECT DATE SHEET DOWL 2025cPLOT DATE:USER:A05/22/202590% PROGRESSBW\\dowl.com\j\Projects\91\12669-01\65CAD\MR24-ST-12669-01.rvt5/20/2025 10:50:43 AMS0.1 RETAINING WALL GENERAL NOTESMAY 2025 4691.12669.01PHASE 1 DESIGN, 915 HIGHLAND BLVD, BOZEMAN, MTBOZEMAN HEALTH CAMPUSPRELIMINARY -FOR REVIEWMGOLDBERGRETAINING WALL GENERAL NOTES: STRUCTURAL ABBREVIATIONS ALT -ALTERNATE ANC -ANCHOR BB -BACK TO BACK BLDG -BUILDING BOT -BOTTOM BTWN -BETWEEN CIP -CAST IN PLACE CL -CENTERLINE CLR -CLEAR CLSM -CONTROLLED LOW STRENGTH MATERIAL CONC -CONCRETE CONT -CONTINUOUS COORD -COORDINATE CNJT -CONTRACTION JOINT CSJT -CONSTRUCTION JOINT CY -CUBIC YARD DBA -DEFORMED BAR ANCHOR DIA OR ⌀-DIAMETER DIAG -DIAGONAL DIM -DIMENSION DIST -DISTANCE DWG -DRAWING DWL -DOWEL E -EAST EA -EACH EF -EACH FACE EL -ELEVATION EQL -EQUAL EXST -EXISTING EXP -EXPANSION EXT -EXTERIOR FDN -FOUNDATION FF -FRONT FACE FT -FOOT FTG -FOOTING GALV -GALVANIZED GB -GRADE BEAM GVW -GROSS VEHICLE WEIGHT HAS -HEADED ANCHOR STUD HORZ -HORIZONTAL HT -HEIGHT IN -INCH INFO -INFORMATION INT -INTERIOR ISJT -ISOLATION JOINT JT -JOINT KIP -1,000 LBS KSF -KIP PER SQUARE FOOT KSI -KIP PER SQUARE INCH LAT -LATERAL LBS -POUND(S) LOC -LOCATION LONG -LONGITUDINAL LP -LOW POINT MATL -MATERIAL MAX -MAXIMUM MFR -MANUFACTURER MIN -MINIMUM MISC -MISCELLANEOUS N -NORTH NO. OR # -NUMBER NOM -NOMINAL NTS -NOT TO SCALE OC -ON CENTER OPNG -OPENING OPP -OPPOSITE PL -PLATE PROJ -PROJECTION PSF -POUNDS PER SQUARE FOOT PSI -POUNDS PER SQUARE INCH QTY -QUANTITY R -RADIUS REF -REFERENCE (REFER TO) REINF -REINFORCEMENT REQD -REQUIRED RF -REAR FACE S -SOUTH SHT -SHEET SIM -SIMILAR SPA -SPACE OR SPACES SPEC -SPECIFICATIONS SQ -SQUARE STD -STANDARD STRUCT -STRUCTURAL SYM -SYMMETRICAL T & B -TOP AND BOTTOM THK -THICKNESS TOC -TOP OF CONCRETE TOF -TOP OF FOOTING TOL -TOP OF LEDGER TRANS -TRANSVERSE TOW -TOP OF WALL TYP -TYPICAL UNO -UNLESS NOTED OTHERWISE VERT -VERTICAL W -WEST W/ -WITH W/O -WITHOUT WP -WORK POINT WT -WEIGHT WWR -WELDED WIRE FABRIC 1. GENERAL REQUIREMENTS DESIGN AND ALL MATERIALS, FABRICATION, INSPECTIONS, TESTING AND CONSTRUCTION SHALL COMPLY WITH THESE GENERAL NOTES AND PROJECT SPECIFICATIONS AND STANDARDS. 2. GOVERNING CODES AND SPECIFICATIONS INTERNATIONAL BUILDING CODE (IBC), 2024 EDITION MINIMUM DESIGN LOADS AND OTHER ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES, ASCE 7-22 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 318-19(22) 3. SPECIAL INSPECTIONS a. SEE SCHEDULE SHEET S2.1. 4. DESIGN LOADS a. DEAD LOAD i. SELF WEIGHT INCLUDING STONE VENEER b. LIVE LOAD i. VEHICLE SURFACE SURCHARGE: 250 PSF c. SEISMIC LOAD CRITERIA i. MAPPED SPECTRAL RESPONSE SS: 0.65 ii. MAPPED SPECTRAL RESPONSE S1: 0.18 iii. PROJECT SITE CLASS: D iv. SPECTRAL RESPONSE COEFFICIENT SDS: 0.58 v. SPECTRAL RESPONSE COEFFICIENT SD1: 0.32 vi. PEAK GROUND ACCELERATION PGAm: 0.34 vii. SEISMIC DESIGN CATEGORY: D viii. IMPORTANCE FACTOR: 1.00 5. BURIED WALL DESIGN CRITERIA a. GEOTECHNICAL REPORT ORIGINATED FOR THE PROJECT SITE BY DOWL 'BOZEMAN HEALTH - PHASE I NE PARKING LOT, DATED MAY, 2025. FOUNDATION DESIGN CRITERIA: i. FROST DEPTH: 36 IN ii. NET ALLOWABLE SOIL BEARING PRESSURE: 2,500 PSF ON STRUCTURAL FILL, ALLOW ONE-THIRD INCREASE FOR SEISMIC iii. SUBGRADE MODULUS, k: 150 PCI iv. LATERAL SOIL PRESSURE (EQUIV FLUID FOR LEVEL GRADE CONDITION): ACTIVE: 40 PCF AT-REST: 60 PCF PASSIVE: 360 PCF (FOR LEVEL GRADE CONDITION) v. DESIGN WATER TABLE SURFACE ELEVATION BELOW FOOTINGS vi. COEFFICIENT OF FRICTION: 0.50 ON STRUCTURAL FILL vii. LATERAL LIVE LOAD SURCHARGE COEFF, ACTIVE: 0.33 viii. SEISMIC EARTH PRESSURE COEFFICIENT Kh: 0.17 c. EXCAVATION i. LOCATE UNDERGROUND UTILITIES BY SURFACE SCANNING OR CAREFUL EXPLORATION BEFORE STRUCTURE EXCAVATION. ii. EXCAVATION METHODS, SLOPES AND SHORING ARE THE CONSTRUCTOR'S RESPONSIBILITY TO DESIGN AND INSTALL AND MUST BE IN COMPLIANCE WITH OSHA 29 CFR 1926 BASED ON SITE SPECIFIC SOIL TYPE "C". iii. EXCAVATION SURFACE BARRIERS FOR PERSONS, EQUIPMENT AND SURFACE WATER ARE THE CONSTRUCTOR'S RESPONSIBILITY. iv. EXCAVATION PERMITS MAY BE REQUIRED. d. SUBGRADE i. SCARIFY, MOISTURE CONDITION AND RECOMPACT 12 INCHES OF NATIVE SOIL SUBGRADE BELOW EXCAVATED LIMITS IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND AS DIRECTED BY THE GEOTECHNICAL REPRESENTATIVE. ii. FOOTINGS SHALL BEAR ON COMPACTED STRUCTURAL FILL ON A GEOTEXTILE STABILIZATION FABRIC OVER SUBGRADE SOILS APPROVED BY THE GEOTECHNICAL REPRESENTATIVE. iii. STRUCTURAL FILL IS 1 1/2" MINUS GRANULAR SUCH AS MDT CRUSHED BASE TYPE 'B' GRADE 1 EXCEPT UP TO 12% PASSING THE #200 SIEVE. MOISTURE CONDITION AND COMPACT STRUCTURAL FILL TO 97% DENSITY IN ACCORDANCE WITH ASTM D698. iv. GEOTEXTILE STABILIZATION FABRIC SUCH PER MDT SPEC TABLES 716-1 AND 716-3e. e. BACKFILL i. WALL BACKFILL MATERIAL IS GRANULAR OR COARSE GAINED SUCH AS USCS CLASSIFICATION GP, GM, GW, GC, SP OR SM WITH NO PARTICLES LARGER THAN 2 INCH, AT LEAST 30% RETAINED ON A #4 SIEVE AND NO MORE THAN 15% PASSING A #200 SIEVE. (DESIGN PHI VALUE ≥ 30 DEGREES, DRY UNIT WEIGHT 120 PCF) ii. MOISTURE CONDITION, PLACE AND COMPACT APPROVED BACKFILL MATERIALS IN ACCORDANCE WITH PROJECT SPECIFICATIONS AFTER CONCRETE HAS GAINED THE MINIMUM STRENGTH SPECIFIED. iii. PLACE AND COMPACT BACKFILL ON WALLS BURIED BOTH SIDES IN EQUAL LIFTS ON EACH SIDE OF WALL. UNBALANCED LIFT SURFACES MUST NOT EXCEED 1.5 FEET. 6. CONCRETE a. MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE SPECIFICATIONS FOR STRUCTURAL CONCRETE (AC1 301), BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318) AND SPECIFICATION FOR CURING CONCRETE (ACI 308.1). b. DETAILING, FABRICATION AND PLACEMENT OF REINFORCEMENT SHALL CONFORM TO DETAILS AND DETAILING OF CONCRETE REINFORCEMENT (ACI 315) c. MATERIALS i. PORTLAND CEMENT - - - - - - - - - - - - - - - - - - - - - - - - - ASTM C150 OR C595 ii. FLY ASH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASTM C618 TYPE C OR F iii. NORMAL WEIGHT AGGREGATES - - - - - - - - - - - - - - - ASTM C33 CLASS 4S iv. AIR-ENTRAINING ADMIXTURE - - - - - - - - - - - - - - - - - - ASTM C260 v. WATER-REDUCING ADMIXTURE - - - - - - - - - - - - - - - - ASTM C494 vi. WATER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - POTABLE vii. REINFORCING BARS - - - - - - - - - - -- - - - - - - - - - - - - - - ASTM A615, GRADE 60 viii. POST-INSTALLED ANCHOR OR REBAR DOWEL ADHESIVE HILTI HIT-HY-200 V3 OR HIT-RE 500 V3 d. ALL BENT REINFORCING BARS SHALL BE SHOP FABRICATED. REBENDING OR WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS AUTHORIZED BY ENGINEER. END HOOKS IN REINFORCING BARS, SHOWN ON THE DRAWINGS BUT NOT DIMENSIONED, SHALL CONFORM TO ACI 318 STANDARDS. e. CONCRETE MIX DESIGN, KEY PARAMETERS: SEE SCHEDULE THIS SHEET f. LAP REINFORCING BARS PER SCHEDULE THIS SHEET. g. STAGGER ADJACENT LAPS 24 INCHES MINIMUM. h. ADJUST REBAR SPACING OR POSITION NOMINALLY AS REQUIRED TO CLEAR EMBEDDED ITEMS SUCH AS ANCHORAGES. i. PROVIDE REBAR SUPPORTS TO PROPERLY SECURE AND SUPPORT REINFORCING IN ACCORDANCE WITH CRSI UNLESS SHOWN/INDICATED OTHERWISE. PROVIDE #4 STANDEES AT 4 FT MAX TO SUPPORT TOP REINFORCEMENT MATS IN FOOTINGS. j. DOWELS, SLEEVES AND OTHER INSTALLED MATERIALS AND ACCESSORIES SHALL BE HELD SECURELY IN POSITION DURING CONCRETE PLACEMENT. k. REINFORCING BARS AND ACCESSORIES SHALL NOT BE IN CONTACT WITH ANY SLEEVE OR METAL PART EMBEDDED IN CONCRETE. PROVIDE 2" CLEARANCE IN ALL CASES UNLESS OTHERWISE INDICATED. NO EMBEDDED ITEM SHALL BE SUSPENDED FROM, SUPPORTED BY, OR BRACED IN PLACE FROM REINFORCEMENT. l. THOROUGHLY CLEAN HORIZONTAL CONSTRUCTION JOINT SURFACES BY WET JET OR SANDBLAST BEFORE SECOND CONCRETE PLACEMENT. m. CHAMFER ALL EXPOSED CONCRETE EDGES 3/4" UNLESS OTHERWISE INDICATED. 7. WATER STOP& JOINT SEALANT a. PVC WATERSTOPS MANUFACTURED FROM VIRGIN MATERIALS AND IN COMPLIANCE WITH CORPS OF ENGINEERS STANDARD CRD-C 572-74 RIBBED CENTER BULB UNLESS INDICATED OTHERWISE. HEAT WELD WATERSTOP JOINTS AND INTERSECTIONS. USE OF HOG RINGS AND TIE WIRE TO MAINTAIN POSITION AND TAUT CONDITION DURING CONCRETE PLACEMENT IS REQUIRED. b. HYDROPHILIC WATERSTOPS COMPRISED OF BENTONITE CLAY AND BUTYL RUBBER IN COMPLIANCE WITH ASTM D6. SIZE IS 3/4 INCH x 1 INCH UNLESS INDICATED OTHERWISE. APPLICATION OF A PRIMER ADHESIVE WITH INSTALLATION IS REQUIRED. c. URETHANE BASED JOINT SEALANT IN ACCORDANCE WITH ASTM C920 TYPE M, CLASS 50. 8. STONE VENEER a. COORDINATE STONE VENEER TIES OR ANCHORAGES WITH CONCRETE WORK. b. ALIGN VENEER CONTRACTION AND EXPANSION JOINTS WITH THOSE IN THE CONCRETE WALL. ADDITIONAL JOINT LOCATIONS MAY BE REQUIRED BY THE STONE VENEER SPECIFICATIONS OR AT THE DISCRETION OF THE MASON. REDI-MIXED CONCRETE SCHEDULE WITH KEY MIX DESIGN PARAMETERS MIX CLASS USE ACI 318 EXPOSURE CATEGORIES PORTLAND CEMENT TYPE C150 OR C595 w/cm RATIO LIMIT DESIGN COMPRESSIVE STRENGTH f'c COARSE AGGREGATE SIZE, MAX TOTAL AIR CONTENT SLUMP RANGE CLASS A WALLS F2 / S0 / W1 / C1 TYPE I/II, IL 0.45 4,500 PSI 1" (#57) 6.0%; -1.0% +2.0%4"+/-1" CLASS B FOOTINGS F1 / S0 / W1 / C1 TYPE I/II, IL 0.48 4,000 PSI 1" (#57) 4.5%; -1.0% +2.0%4"+/-1" REINFORCING BAR LAP SCHEDULE REBAR SIZE GENERAL LAP TOP BAR LAP HOOKED TENSION DEVELOPMENT #4 1'-9" 2'-3" 0'-8" #5 2'-0" 2'-9" 0'-10" #6 2'-6" 3'-3" 1'-0" #7 3'-6" 4'-9" 1'-2" CONCRETE MIX SCHEDULE NOTES: 1. REFERENCE PROJECT SPECIFICATION SECTION 033000 FOR COMPLETE MATERIALS REQUIREMENTS. DURABILITY OF CONCRETE MIXES SHALL BE IN ACCORDANCE WITH ACI 318 CHAPTER 19. 2. USE OF A POZZOLAN, SUCH AS FLY ASH, IS PREFERRED WITH ASTM C150 CEMENT. MINIMUM CEMENTITIOUS CONTENT IS 588 LB/CY. 3. DESIGN COMPRESSIVE STRENGTH INDICATED AT 28 DAYS. EARLY STRENGTH REQUIREMENTS PER CONSTRUCTOR'S PROJECT SCHEDULE. 4. CLASS B CONCRETE FOR BURIED FOOTINGS WITH REDUCED FREEZE/THAW EXPOSURE, CLASS A MAY BE USED AT CONSTRUCTOR'S OPTION. 5. SLUMP INDICATED IS A TARGET ONLY AND MAY BE MODIFIED IN THE MIX DESIGN TO SUIT CONCRETE PLACEMENT METHODS. REINFORCING BAR LAP SCHEDULE NOTES: 1. TENSION LAP LENGTHS SHOWN ARE CLASS B, CONTACT SPLICES, FOR CAST-IN-PLACE CONCRETE FOR CRITERIA INDICATED. 2. LENGTHS BASED ON GRADE 60 UN-COATED DEFORMED BARS WITH CONCRETE COMPRESSIVE STRENGTH f'c 4,000 PSI MINIMUM; 2" CONCRETE COVER. 3. TOP BAR LAPS ARE HORIZONTAL LAPS WHERE MORE THAN 12" OF FRESH CONCRETE IS PLACED BELOW THE BAR. 4. BAR HOOK GEOMETRY IN ACCORDANCE WITH ACI 318 CHAPTER 25.