Loading...
HomeMy WebLinkAbout052_L2.5_LandscapeDetails FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION915 HIGHLAND BOULEVARDLANDSCAPE DETAILSBOZEMAN HEALTH CAMPUSPHASE 1 DESIGNBOZEMAN, MTL2.5 BE/KP17095_13_LS_DETAILS.DWGDE/AM03/11/2025SITE PLAN SUBMITTAL05/23/202506/02/202507/07/2025---SITE PLAN SUBMITTALBID SETSITE PLAN SUBMITTAL-----17095.13PIN & MORTAR AS NECESSARY 6"1" OVERHANG VARIES, SEE STRUCTURAL 1" AIR SPACE STONE VENEER STONE CAP NOTES: 1.DETAILS ARE FOR DESIGN INTENT ONLY. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND NECESSARY CUT SHEETS FOR ALL STONE AND VENEER ELEMENTS FOR OWNER AND LANDSCAPE ARCHITECT APPROVAL. 2.MORTAR COLOR TO BE DETERMINED, 3.STONE VENEER AND CAP STONE SHALL BE FRONTIER SANDSTONE BY QUARRY WORKS. 4.CAP STONE SHALL BE A SMOOTH TOP FINISH AND NATURAL EDGE FINISH. 5.VENEER SHALL BE ATTACHED USING EMBEDDED ANCHOR SLOTS. MASONRY TIE BACKFILL, SEE STRUCTURAL TOPSOIL ROCK MULCH DRIP CHANNEL CAST-IN-PLACE CONCRETE RETAINING WALL, SEE STRUCTURAL DAMPPROOF COATING, SEE STRUCTURAL SLOPE TO DRAIN FINISH GRADE VENEER WEEP HOLE 2"STONE VENEER AND WALL CAP N.T.S.VARIES, SEE CIVIL18" MAX.DRIP CHANNEL 2 INDIVIDUALLY MOUNTED INTERNALLY ILLUMINATED CHANNEL LETTERS PLANTING BED, SEE LANDSCAPE PLANS PLANTING BED, SEE LANDSCAPE PLANS CAST-IN-PLACE CONCRETE RETAINING WALL, SEE STRUCTURAL CONCRETE FOOTINGS, SEE STRUCTURAL BACKFILL, SEE STRUCTURAL CONCRETE FOOTINGS, SEE STRUCTURAL CONCRETE FOOTINGS, SEE STRUCTURAL BACKFILL, SEE STRUCTURAL CAST-IN-PLACE CONCRETE RETAINING WALL, SEE STRUCTURAL CAST-IN-PLACE CONCRETE RETAINING WALL, SEE STRUCTURAL RETAINING WALL SECTION N.T.S. 4 L2.1 PERENNIAL/GRASS/GROUNDCOVER PLANTING SUBDRAINS, SEE CIVIL SUBDRAINS, SEE CIVIL CONDUIT TO SIGN LETTERS NOTES: 1.DETAILS ARE FOR DESIGN INTENT ONLY. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL RETAINING WALL AND SIGNAGE ELEMENTS FOR OWNER AND LANDSCAPE ARCHITECT APPROVAL. 2.SIGNAGE SHALL BE INDIVIDUALLY MOUNTED TO CAST IN PLACE CONCRETE RETAINING WALL IN ACCORDANCE TO SIGN MANUFACTURER'S RECOMMENDATIONS. 3.SIGNAGE LETTERS SHALL BE INTERNALLY LIT. 4.SEE STRUCTURAL AND CIVIL FOR CAST IN PLACE CONCRETE RETAINING WALL DESIGN AND ENGINEERING. 2 L2.5 STONE VENEER AND WALL CAP 2 L2.5 STONE VENEER AND WALL CAP 2 L2.5 STONE VENEER AND WALL CAP 1 L2.4 BOZEMAN HEALTH SIGNAGE 3 L2.1 SHRUB PLANTING 3 ELEVATION VIEW SECTION 26.00'6.00'13.00'6" CLR.OPENING COUNTER BALANCE POSTS CANTILEVER GATE N.T.S. KNOX BOX SHALL BE INSTALLED FOR EMERGENCY ACCESS NOTES: 1.CONTRACTOR SHALL SUBMIT SHOP DRAWING OR CUT SHEETS FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 2.DETAIL IS FOR DESIGN INTENT ONLY. 3.GATE SHALL BE STANDARD 2" X 2" GALVANIZED CHAINLINK. 4.ALL CHAINLINK SHALL HAVE VINYL PRIVACY SLATS IN THE COLOR BLACK. GATE LATCH 2"x2" GALVANIZED CHAINLINK WITH VINYL PRIVACY SLATS 4" OD SCHEDULE 40 POSTS GATE ROLLERS, TYP. GATE ROLLERS, TYP. LATCH POST CANTILEVER ROLLER ASSEMBLY GATE POST CONCRETE FOOTING 4.00' OC 6"GATE STOP 7 L2.2 CHAINLINK FENCE - 6' HEIGHT CONCRETE FOOTING 1 P:\17095_13_Bozeman_Health_Phase_1_Design_CA\CADD_C3D\PRODUCTION_DWG\17095_13_LS_DETAILS.dwg, L2.5, 7/7/2025 12:08:02 PM, amartoncik, 1:1