Loading...
HomeMy WebLinkAbout046_E1.6_ElectricalDetails FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION915 HIGHLAND BOULEVARDELECTRICAL DETAILSBOZEMAN HEALTH CAMPUSPHASE 1 DESIGNBOZEMAN, MTE1.6 BE/KP17095_13_ELEC_PROD.DWGDE/AM03/11/2025SITE PLAN SUBMITTAL05/23/202506/02/202507/07/2025---SITE PLAN SUBMITTALBID SETSITE PLAN SUBMITTAL-----17095.131 2 3 4 5 6 7 8 9 10 11 12 13 14 15 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 4 4 4 4 4 10 10 10 10 10 10 10 10 IDENTITY NO. DESCRIPTIVE SYMBOL & WIRE SIZES 10 10 10 17 18 19 20 16 10 10 NON-FUSED BREAKAWAY FUSED BREAKAWAY FUSED BREAKAWAY NON-FUSED BREAKAWAY NON-FUSED NON-BREAKAWAY PROVIDE A PLUG AND RECEPTACLE HOUSED IN WATER- RESISTANT, SYNTHETIC RUBBER CAPABLE OF BURIAL IN THE GROUND OR INSTALLATION IN SUNLIGHT. THE HOUSING, CONSISTING OF 2 SECTIONS, PROVIDES A WATERTIGHT SEAL AROUND THE CABLE AND A WATERTIGHT SEAL BETWEEN THE TWO SECTIONS AT THE POINT OF DISCONNECTION. SUPPLY EACH KIT WITH SUFFICIENT SILICONE COMPOUND TO LUBRICATE METAL PARTS AND THE RUBBER HOUSINGS FOR EASY ASSEMBLY. WHERE INDICATED, CRIMP A COPPER PIN AND A COPPER RECEPTACLE TO THE CABLE. THE RECEPTACLE IS TO ESTABLISH CONTACT PRESSURE WITH THE PIN THROUGH THE USE OF A COPPER BERYLLIUM SPRING AND BE EQUIPPED WITH A DISPOSABLE MOUNTING PIN. THE PIN IS TO BE CONSTRUCTED OF AT LEAST HALF-HARD MATERIAL. THE CRIMPING PORTION IS TO BE FULLY ANNEALED WHILE THE REST OF THE PIN IS MAINTAINED IN ITS ORIGINAL STATE OF HARDNESS. THE RECEPTACLE IS TO BE FULLY ANNEALED. THE PIN AND RECEPTACLE ARE TO LOCK TOGETHER SO THE CONNECTION IS MAINTAINED WHEN A MINIMUM FORCE OF 20 POUNDS TENSION IS APPLIED TO THE ATTACHED CABLES. PROVIDE FUSED CONNECTOR KITS CONTAINING A PAIR OF SPRING LOADED 90% CONDUCTIVITY CONTACTS FOR GRIPPING A STANDARD MIDGET FERRULE TYPE FUSE. THE CONTACTS MUST BE FULLY ANNEALED AND ADAPTED TO BE CRIMPED TO THE CABLE. 21 TYPE 21 VARIES VARIES VARIES COPPER SPLIT BOLT - MAKE WATERTIGHT USING SELF ADHERING MASTIC 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 NO SCALE TYPES 1, 6, 11 & 16 TYPES 2, 7, 12 & 17 TYPES 3, 8, 13 & 18 TYPES 4, 9, 14 & 19 TYPES 5, 10, 15 & 20 WATERTIGHT CONNECTORS WATERTIGHT CONNECTORS AWG NO.2 SERVICE 120/240 VOLT GROUND ROD BARE AWG NO.6 SERVICE RATED 200 AMP METER MAIN CIRCUIT BREAKER 20 AMP,2 POLE, SINGLE THROW MAIN DISCONNECT 200 AMP CIRCUIT BREAKER 20 AMP,2 POLE, SINGLE THROW AWG NO.14 AWG NO.6 TO LUMINAIRES AWG NO.10 (120 V) (120 V) (120 V) N.E.M.A.TYPE 3R CABINET AUTO-OFF-MANUAL SWITCH PHOTO-ELECTRIC CONTROL TO LED SIGN AWG NO.8 LUM SERVICE WIRING DIAGRAM 40 AMP CONTACTOR 4 POLE,SINGLE THROW LIGHTNING ARRESTOR TO GROUND LUG OF EACH POLE (120 V)P:\17095_13_Bozeman_Health_Phase_1_Design_CA\CADD_C3D\PRODUCTION_DWG\17095_13_ELEC_PROD.dwg, E1.6, 7/7/2025 4:40:55 PM, kketterling, 1:1