Loading...
HomeMy WebLinkAbout019_2501 BSF HQ - Sheet - A300 - Elevations136452PNT -1PNT -24" / 1'-0"60' - 0"10' - 0"(E) T.O. Slab0' -0"(E) T.O. Plate16' -0"(E) T.O. Roof24' -1"ACT.O. SF -2nd Level8' -8 7/8"BPNT -1PNT -2Existing Framed Opening12' - 0"(N) MTL Awning,Painted Black(E) Roof Finish to Remain,Repair as Needed(E) Metal Siding to Remain, Repair as Needed, Painted per Legend(N) WDW & Doors, Utilizing Existing Openings, TYP(N) Wall Sconce, See Elec.4" 1'-0"4" 1'-0"(E) Opening/Framing Behind Siding(Prepped for Opening, Never Installed)ADD ALT: Transom Window Above102D3'-0" x 4'-0"40' - 0"10' - 0"Existing Framed Opening14' - 0"4' - 0"1' - 0"9' - 0"G111136452(E) Asphalt Shingle Roof,to Remain, Repair as Needed(E) Metal Siding to Remain, Repair as Needed,Painted per Legend(N) Exterior Sconces,5 Total, See ElecPNT -1PNT -2FC-14" / 1'-0"(N) WDW & Doors,Utilizing Existing Openings, TYP(E) For All Utility Meters on South Wall, See Civil.See Landscape for ScreeningBABC4'-0" x 5'-0"4'-0" x 4'-0"4'-0" x 5'-0"3'-0" x 2'-0"60' - 0"1' - 0"5' - 0"To Verify (E) Opening HGT10' - 0"FC-1FC-1FExisting Opening14' - 0"2' - 6"1' - 6"10' - 0"20' - 0"40' - 0"Existing Opening12' - 0"3'-6" Entry Awning3' Min Awning Req.COB "Other" Block FrontageE12511' - 2"10"Finish to Match ExistingFC-11(E) T.O. Slab0' -0"(E) T.O. Plate16' -0"(E) T.O. Roof24' -1"ACT.O. SF -2nd Level8' -8 7/8"B(N) MTL Awning,Painted BlackExisting Opening14' - 0"(N) Wall Sconce, See Elec.4" 1'-0"4" 1'-0"(E) Roof Finish to Remain,Repair as Needed(E) Metal Siding to Remain, Repair as Needed, Painted per LegendPNT -1PNT -2C105AB4'-0" x 5'-0"40' - 0"(N) Ridge Vent,Existing Ventilation to be Accessed & Addressed As-Necesasry3'-0" x 2'-0"10' - 0"FC-1G1045' - 0"9' - 0"Existing Opening12' - 0"111PNT -1PNT -2LEGEND -EXTERIOR ELEVATIONFC -1Existing Metal Siding PaintedFC -1 Fiber Cement Panel -BlackLEGEND -EXTERIOR ELEVATION -REALISTIC(Window & Door Frames) - Black AluminumPNT -1PNT -211GENERAL NOTES1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION; NOTIFY ARCHITECT OF ALL DISCREPANCIES.2. CONTRACTOR TO VERIFY EXISTING UTILITY LOCATIONS PRIOR TO CONSTRUCTION.3. DIMENSIONS ARE TO FACE OF FRAMING, FACE OF CONCRETE, GRIDLINE, OR CENTERLINE OF OBJECT, U.N.O.4. DETAIL DRAWINGS OR LARGER SCALE DRAWINGS TAKE PRECEDENT OVER SMALLER SCALE DRAWINGS.5. REFERENCE STRUCTURAL FOR SHEAR WALL LOCATIONS6. INTERIOR PARTITION WALLS TO BE TYPE I-1, TYP, U.N.O. REFERENCE A0.1 FOR HORIZONTAL AND VERTICAL ASSEMBLIES7. VERIFY ALL CLEARANCES/ROUGH OPENIGNS FOR APPLIANCES PLUMBING AND EQUIPMENT8. PROVIDE BACKING OR STRAPPING FOR ALL WALL MOUNTED ACCESSORIES, FURNISHINGS, AND EQUIPMENT, VERIFY WEIGHTS AND LOCATIONS.9. INDICATED INT. WOOD CLADDING10. SEE A002 FOR NEW VS EXISTING WALL ASSEMBLIESA. EXISTINGB. NEWPROJECT #SHEET NUMBERREVISION:DATE618 N Wallace | Bozeman, MT 59715DRAFTNOT FOR CONSTRUCTIONThis drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above.Consultant:971−319−6249 | www.minarikarch.comProject Status:© 2024 MINARIK Architecture, IncALL RIGHTS RESERVEDThese Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.6/25/2025 11:56:44 AM12501A300BSF HeadquartersBridger Ski Foundation1606 Gold AvenueBozeman, Montana6/25/2025ElevationsSite Plan Review1/4" = 1'-0"EXTERIOR ELEVATION - NORTH11/4" = 1'-0"EXTERIOR ELEVATION - EAST21/4" = 1'-0"EXTERIOR ELEVATION - SOUTH31/4" = 1'-0"EXTERIOR ELEVATION - WEST4REVISION DATE REASON FOR ISSUE1 6/25/2025 SP Review ResubmittalWindow ScheduleType Mark Count Height Width Material Finish CommentsA 1 4' - 0" 4' - 0"B 3 5' - 0" 4' - 0"C 2 2' - 0" 3' - 0"D 1 4' - 0" 3' - 0"E 1 7' - 6" 19' - 6"