HomeMy WebLinkAbout013b_2501 BSF HQ - L601 - Irrigation PlanLO
T
4BOMONT
CEN
T
ER
SUB
.
TR
AC
T
5A
INDUS
TR
IA
L
PROPER
T
IES
SUB
.ToiletCompartment108ToiletCompartment109Restroom107MechanicalRoom110ShowerCompartment111EntryLobby101BreakoutRm102ConferenceRm103Work Rm105Gear Rm104LockerHallway106WWBTVBTVWWWWWWWWWNORHAR8'8'8'8'8'CPWD DDDDDDDDD DDDDD
DDDDD
DDDDD ZONE 6S1.0"7.81D DDDD DDDDD DDDDD
BFCP2418182424DD D DDDDDDDDDDDDDD
DDDDDDDDDDDDDDDDDD DDDDDDDDDDDDDDDDDDDD 242424 24241212121212122424 SSSRSRSSSRSRSRSRSRSRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR
ZONE 2S1.0"10.18ZONE 4D1.0".35IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRZONE 1TS1.0"3.20IRRIRRIRRIRR
IRR
IR
RDDDDDD DDDDDDDDDDDDDDDDDDDDDDDDDZONE 7D1.0"0.28IRR MAIN IRR MAIN
IRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR
IRR IRR IRR
IRRIRRIRRIRRIRRIRR IRR IRR IRR
IRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR
IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDIRRDDDDD ZONE 3DT1.0"0.33ZONE 9DT1.0"0.2718IRRIRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRR IRRIRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR IRR IRRIRRIRRIRRIRRIRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR
IRR IRRIRRIRRIRRIRRIRRZONE 5D1.0"0.17ZONE 8D1.0".29IRR IRR IRR IRRIRRIRR1818MAIN LINE ISOLATION VALVE,& QUICK COUPLER FOR BLOWOUT USEWEATHER STATIONVERIFY LOCATIONIN FIELDWALL MOUNTEDOUTDOOR CONTROLLERVERIFY LOCATION IN FIELD, ELECTRICAL AND ARCH. TOPROVIDE & COORDINATEPOWER OUTLETIRRIGATION SLEEVE, TYP.CMEP TO PROVIDE 1.5" STUB ANDBACKFLOW PREVENTER FORIRRIGATION IN HOUSEMECHANICAL ROOM PLACEBACKFLOW PREVENTION NEARFLOOR DRAINS.ALL SPRINKLER HEADS MUST BE SPACEDA MINIMUM OF 2" FROM HARDSCAPE EDGES, TYP.182424
IRR IRR IRR IRR
IRRIRRIRRIRRIRR IRR IRR IRR IRR
IRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR
NOTES:1.PRS 40 AND PRS 30 SPRAY BODIES DESIGNED TO REGULATE PRESSURESAT 40PSI AND 30PSI PER HEAD, HEADS TO BE ADJUSTED TO ACHIEVEPROPER ARC RADIUS.2.***PVC 1" LATERAL LINES CREATE SLIGHTLY MORE PSI LOSS THAN 1"PE LATERAL LINES, PVC OR POLY ARE ACCEPTABLE. SEE PRESSURE LOTCHARTS3.ALL BUILDING LANDSCAPE IRRIGATION TO BE COORDINATED WITHLANDSCAPE CONTRACTOR, G.C., MEP, ARCH., AND PLUMBER.4.CONNECTION POINT TO BE DETERMINED BY OTHERS, GRAPHICALLYSHOWN FOR INTENT ONLY5.PROVIDE BACKFLOW PREVENTION IN WET MECH ROOM ABOVE FLOORDRAIN AND STUB OUT OF THE BUILDING DURING CONSTRUCTION OFHOME.6.FINAL IRRIGATION AND PLUMBING EQUIPMENT SUBJECT TO CHANGE.7.IRRIGATION SLEEVING TO BE PROVIDED BY CIVIL CONTRACTOR/GC; SETSLEEVES UNDER ROADS PER PLAN COORDINATE WITHLANDSCAPE/IRRIGATION INSTALLER PRIOR TO POURING ROADS ORCONCRETE AND SETTING BOULDER RETAINING WALLS8.ALL SPRINKLER HEADS MUST BE SPACED A MINIMUM OF 2" FROMHARDSCAPE EDGES, TYP.9.ALL DRIP IRRIGATION ZONES MUST BE INSTALLED WITH THE ABILITY TOEASILY FLUSH THE SYSTEM.10.OVERHEAD IRRIGATION MUST USE A 6" MINIMUM RISER, PER CITY OFBOZEMAN LANDSCAPE & IRRIGATION STANDARDS.11.SEE IRRIGATION PLANS FOR MORE INFORMATION SHEETS L6.00-L7.01SYMBOLSIZEDETAILDESCRIPTIONIRRIGATION LEGENDIRRIGATION CONTROLLERHUNTER ICC2 OR EQUIVALENTWEATHER STATIONHUNTER MWS-FR OR SIMILARCONNECTION POINTDRIP CONTROL VALVEHUNTER PCZ, ICZ DRIP CONTROL ORSIMILAR1.5" PVC MAINLINE, SCH 40 PVC1.0" LATERAL LINE, SCH 40 PVC or PE***DRIP LINE, SOFT WALL DRIP TUBINGIRRIGATION SLEEVE, 4" MIN. SCH 40 PVCVALVE SCHEDULEIRRDDQTY11117SEE PLANSEE PLANSEE PLANSEE PLANSEE PLAN21QUICK COUPLER FOR BLOW OUT USERAINBIRD HQ44-RC OR SIMILARISOLATION VALVE/GATE VALVE DRAINNIBCO T-113 BRONZE GATE VALVE ORSIMILARHUNTER PRS40 POPUP SPRAYBODYWITH MPR 2000 NOZZLE (90-360 DEG)24CONTROL VALVE(SPRAY ZONES)HUNTER PGV, ICV OR SIMILAR7TREE DRIP LINE, SOFT WALL DRIPTUBINGSEE PLANDDDZONE #/TYPESIZEGPMC12WZONE TYPESS= MP ROTATOR OR SPRAY NOZZLE (SEE IRRIGATION LEGEND)R= ROTARY IRRIGATION HEADSD= DRIP IRRIGATIONDT = DRIP TREE IRRIGATIONBFCP1, L7.002, L7.003, L7.0010, L7.008, L7.004, L7.001, L7.015, L7.005, L7.002-5, L7.016, L7.002-3, L7019, 11,12L7.00BACKFLOW PREVENTER- see MEPWATTS 009 RPZ OR EQUIVALENT1.5"1.0"1.0"IRR MAIN2418SRHUNTER SS-530 STRIP PATTERNNOZZLE101, L7.01105020N1L6011"=10'-0"Irrigation PlanIrrigation PlanL 601design5la.com406.587.4873dateissue06/25/25Site Plan Reviewdrawn by:checked by:filename:z:\bsf hq\autocad\01_sheets\bsfhq_irrigation.dwg
Bridger Ski Foundation
Headquarters
Bozeman, Montana
KHM/HU TMS