HomeMy WebLinkAboutFIrst Security Bank Fire Service0 10
SCALE: 1" = 10'
20510
NORTH
C5.1FIRE SERVICE LINE PLAN AND PROFILEissue date
dateprojectownersheet
phase
revision
project #P:\20078_01_First_Security_Bank_Cattail_Bozeman\CADD_C3D\PRODUCTION_DWG\20078.01_FIRE LINE PnP PROD.dwg Jun 15, 2022 - 11:51am20042
02.02.2022FIRST SECURITY BANKGLACIER BANCORPCITY REVIEW 06/15/22
CONSTRUCTION
DOCUMENTS
GENERAL NOTES:
1.ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH
EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011, WITH ADDENDUM.
2.EXISTING UNDERGROUND INSTALLATIONS AND PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST
INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION.
SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS
INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR
EXACT LOCATIONS.
3.UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE
CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE WHERE IS PROJECT IS LOCATED AND BY A PARTY CHIEF OR
ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE
SPECIFIC TYPE OF WORK BEING PERFORMED.
4.ANY EXISTING OR NEW VALVES WHICH CONTROL THE C.O.B.'S WATER SUPPLY SHALL BE OPERATED BY C.O.B. PERSONNEL ONLY.
5.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO COMMENCING ANY WORK.
6.THE CONTRACTOR SHALL FIELD VERIFY LINE AND GRADE OF EXISTING CONNECTIONS.
SANITARY SEWER:
7.UNLESS OTHERWISE NOTED, ALL SANITARY SEWER SERVICES ARE TO BE 4" SDR 26 PVC INSTALLED PER C.O.B. STANDARD
DRAWING NUMBER 02730-2.
8.UTILITY TRENCHES PER C.O.B. STANDARD DRAWING NUMBER 02221-1.
WATER:
9.USE MECHANICAL JOINT RESTRAINT AT ALL FITTINGS AND VALVES UTILIZING THE APPROVED RESTRAINTS PER CITY OF
BOZEMAN STANDARD MODIFICATIONS TO MONTANA PUBLIC WORKS SPECIFICATIONS SECTION 26660. FIRELINE SHALL ALSO
INCLUDE CONCRETE THRUST BLOCKS AND ALL THREAD RESTRAINTS PER STANDARD DETAILS PROVIDED IN CITY OF BOZEMAN
STANDARD MODIFICATIONS TO MONTANA PUBLIC WORKS SPECIFICATIONS.
10.UNLESS OTHERWISE SPECIFIED, ALL WATER SERVICES ARE ARE TO BE 2" TYPE K COPPER PIPE INSTALLED PER C.O.B. STANDARD
DRAWING NUMBER 02660-6.
11.INSTALL IN TRENCH PER C.O.B. STANDARD DRAWING NUMBER 02221-1.
STORM SEWER:
12.STORM SEWER MANHOLES SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-3 WHEN THE DISTANCE FROM
THE RIM TO THE LOWEST INVERT IS GREATER THAN OR EQUAL TO SIX FEET. INSTALL PER C.O.B. STANDARD DRAWING NUMBER
02720-4, WHEN THIS DISTANCE IS LESS THAN SIX FEET.
13.24"x36" INLETS SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-1A
FIBER OPTIC
GAS PIPELINE
SANITARY SEWER
STORM DRAIN
TELEVISION/CABLE
WATER
CURB AND GUTTER
EDGE OF ASPHALT
EDGE OF GRAVEL
EXISTING
WATER VALVE
FIRE HYDRANT
LEGEND
SANITARY SEWER MANHOLE
FOUND CORNER MONUMENT AS NOTED
EASEMENT
LOT LINE
SIGN
PROPOSED
UNDERGROUND POWER
ASPHALT
CONCRETE
LIGHT POLE