Loading...
HomeMy WebLinkAboutFIrst Security Bank Fire Service0 10 SCALE: 1" = 10' 20510 NORTH C5.1FIRE SERVICE LINE PLAN AND PROFILEissue date dateprojectownersheet phase revision project #P:\20078_01_First_Security_Bank_Cattail_Bozeman\CADD_C3D\PRODUCTION_DWG\20078.01_FIRE LINE PnP PROD.dwg Jun 15, 2022 - 11:51am20042 02.02.2022FIRST SECURITY BANKGLACIER BANCORPCITY REVIEW 06/15/22 CONSTRUCTION DOCUMENTS GENERAL NOTES: 1.ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011, WITH ADDENDUM. 2.EXISTING UNDERGROUND INSTALLATIONS AND PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS. 3.UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE WHERE IS PROJECT IS LOCATED AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED. 4.ANY EXISTING OR NEW VALVES WHICH CONTROL THE C.O.B.'S WATER SUPPLY SHALL BE OPERATED BY C.O.B. PERSONNEL ONLY. 5.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO COMMENCING ANY WORK. 6.THE CONTRACTOR SHALL FIELD VERIFY LINE AND GRADE OF EXISTING CONNECTIONS. SANITARY SEWER: 7.UNLESS OTHERWISE NOTED, ALL SANITARY SEWER SERVICES ARE TO BE 4" SDR 26 PVC INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02730-2. 8.UTILITY TRENCHES PER C.O.B. STANDARD DRAWING NUMBER 02221-1. WATER: 9.USE MECHANICAL JOINT RESTRAINT AT ALL FITTINGS AND VALVES UTILIZING THE APPROVED RESTRAINTS PER CITY OF BOZEMAN STANDARD MODIFICATIONS TO MONTANA PUBLIC WORKS SPECIFICATIONS SECTION 26660. FIRELINE SHALL ALSO INCLUDE CONCRETE THRUST BLOCKS AND ALL THREAD RESTRAINTS PER STANDARD DETAILS PROVIDED IN CITY OF BOZEMAN STANDARD MODIFICATIONS TO MONTANA PUBLIC WORKS SPECIFICATIONS. 10.UNLESS OTHERWISE SPECIFIED, ALL WATER SERVICES ARE ARE TO BE 2" TYPE K COPPER PIPE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02660-6. 11.INSTALL IN TRENCH PER C.O.B. STANDARD DRAWING NUMBER 02221-1. STORM SEWER: 12.STORM SEWER MANHOLES SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-3 WHEN THE DISTANCE FROM THE RIM TO THE LOWEST INVERT IS GREATER THAN OR EQUAL TO SIX FEET. INSTALL PER C.O.B. STANDARD DRAWING NUMBER 02720-4, WHEN THIS DISTANCE IS LESS THAN SIX FEET. 13.24"x36" INLETS SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-1A FIBER OPTIC GAS PIPELINE SANITARY SEWER STORM DRAIN TELEVISION/CABLE WATER CURB AND GUTTER EDGE OF ASPHALT EDGE OF GRAVEL EXISTING WATER VALVE FIRE HYDRANT LEGEND SANITARY SEWER MANHOLE FOUND CORNER MONUMENT AS NOTED EASEMENT LOT LINE SIGN PROPOSED UNDERGROUND POWER ASPHALT CONCRETE LIGHT POLE