Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
014 - Lighting Cut Sheets
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100982670 Date: November 29, 2012 REPORT NO. 100982670CRT-002 TEST OF ONE LED WALL CYLINDER FIXTURE MODEL NO. 11250/CP133536 RENDERED TO KICHLER LIGHTING 7711 E. PLEASANT VALLEY ROAD PO BOX 318010 CLEVELAND, OH 44131 TEST: Electrical and Photometric tests as required to the IESNA test standard. LABORATORY NOTE: The laboratory that conducted the testing detailed in this report has been Qualified, Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US DOE's CALiPER program. STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. AUTHORIZATION: The testing performed was authorized by signed quote number 500418289. STANDARDS USED: The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79: 2008 Approved Method for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI ANSLG C38.377: 2012 Specifications of the Chromaticity of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one sample of model number 11250/CP133536. The sample was received by Intertek on November 14, 2012, in undamaged condition, and one sample was tested as received. The sample designation was 258377-2. DATES OF TESTS: November 28, 2012 through November 29, 2012. Report No. 100982670CRT-002 page 2 of 7 Date: November 29, 2012 SUMMARY Model No.: 11250/CP133536 Description: LED Wall Cylinder – Down Light Only Criteria Result Total Lumen Output 374.1 Lumens Total Power 11.23 W Luminaire Efficacy 33.31 Power Factor 0.925 Current ATHD 32.40% Correlated Color Temperature (CCT) 3075 K Color Rendering Index (CRI) - Ra 85.82 Color Rendering Index (CRI) - R9 31.20 Duv 0.003 Chromaticity Coordinate (x) 0.427 Chromaticity Coordinate (y) 0.393 Chromaticity Coordinate (u’) 0.249 Chromaticity Coordinate (v’) 0.515 EQUIPMENT LIST Equipment Used Model Number Control Number Last Calibration Date Calibration Due Date Leeds & Northup Standard Resistor Manganin Y089 02/24/12 02/24/13 Data Precision Digital Voltmeter 3600 V124 02/24/12 02/24/13 Fluke Multimeter 45 M133 02/24/12 02/24/13 Kikusui DC Power Supply 35-10L E160 --- --- NIST Spectral Flux Standard Source RF1024 --- 09/18/10 100 hours of use Sorenson DC Power Supply DLM150-20E --- --- --- LSI High Speed Mirror Goniometer 6440 --- 11/12/12 12/12/12 Elgar Power Supply CW1251 --- VBU VBU Yokogawa Power Analyzer WT210 E464 04/19/12 04/19/13 Extech Hygro Thermometer 445703 T1359 11/08/12 11/08/13 Labsphere ITS 2 Meter Sphere (2M5) w/ CDS 600 --- 11/26/12 12/03/12 Yokogawa Power Analyzer WT1600 E473 04/20/12 04/20/13 Fluke Thermometer 53 II D588 03/23/12 03/23/13 Extech Hygro-Thermometer 445703 T1357 11/08/12 11/08/13 Report No. 100982670CRT-002 page 3 of 7 Date: November 29, 2012 TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Report No. 100982670CRT-002 page 4 of 7 Date: November 29, 2012 RESULTS OF TESTS Spectral Distribution over Visible Wavelengths nm mW/nm nm mW/nm nm mW/nm nm mW/nm 350 0.042 460 3.668 570 4.581 680 2.300 355 0.039 465 2.975 575 4.820 685 2.067 360 0.027 470 2.431 580 5.041 690 1.828 365 0.016 475 2.050 585 5.218 695 1.627 370 0.030 480 1.722 590 5.338 700 1.437 375 0.034 485 1.535 595 5.489 705 1.262 380 0.053 490 1.524 600 5.585 710 1.112 385 0.009 495 1.602 605 5.637 715 0.986 390 0.015 500 1.767 610 5.616 720 0.866 395 0.020 505 1.963 615 5.571 725 0.741 400 0.032 510 2.197 620 5.453 730 0.644 405 0.023 515 2.403 625 5.321 735 0.577 410 0.035 520 2.620 630 5.118 740 0.490 415 0.053 525 2.801 635 4.882 745 0.423 420 0.094 530 2.984 640 4.638 750 0.377 425 0.176 535 3.148 645 4.336 755 0.329 430 0.319 540 3.324 650 4.034 760 0.268 435 0.585 545 3.530 655 3.750 765 0.000 440 0.981 550 3.725 660 3.438 770 0.204 445 1.597 555 3.946 665 3.136 775 0.180 450 2.574 560 4.159 670 2.832 780 0.165 455 3.551 565 4.378 675 2.565 Sample No. 258377-2 Spectral Data Over Visible Wavelengths Report No. 100982670CRT-002 page 5 of 7 Date: November 29, 2012 RESULTS OF TESTS (cont’d) Photometric and Electrical Measurements at 25°C – I ntegrating Sphere Method Intertek Sample No. Base Orientation Input Voltage (Vac) Input Current (mA) Input Power (Watts) Input Power Factor Current ATHD (%) 258377-2 UP 120.0 100.5 11.20 0.930 32.40 Intertek Sample No. Correlated Color Temperature (K) CRI -Ra CRI -R9 DUV CIE 31’ Chromaticity Coordinate (x) CIE 31’ Chromaticity Coordinate (y) CIE 76’ Chromaticity Coordinate (u’) CIE 76’ Chromaticity Coordinate (v’) 258377-2 3075 85.82 31.20 0.003 0.427 0.393 0.249 0.515 Photometric and Electrical Measurements – Distribution Method Intertek Sample No. Base Orientation Input Voltage (Vac) Input Current (mA) Input Power (Watts) Input Power Factor Absolute Luminous Flux (Lumens) Lumen Efficacy (Lumens Per Watt) 258377-2 UP 120.0 101.2 11.23 0.925 374.1 33.31 Intensity (Candlepower) Summary at 25°C - Candelas Angle 0 22.5 45 67.5 90 0 204 204 204 204 204 5 202 202 201 201 201 10 201 199 198 197 200 15 195 194 194 195 196 20 192 191 189 190 191 25 186 184 181 181 184 30 179 176 174 174 179 35 168 166 164 166 168 40 153 152 152 153 153 45 100 110 134 124 110 50 58 56 66 61 63 55 6 13 43 31 6 60 2 2 2 2 2 65 2 2 2 2 2 70 1 1 1 2 2 75 1 1 1 1 1 80 0 0 0 0 0 85 0 0 0 0 0 90 0 0 0 0 0 Report No. 100982670CRT-002 page 6 of 7 Date: November 29, 2012 RESULTS OF TESTS (cont’d) Illumination Plots Mounting Height: 10 ft. Illuminance - Cone of Light Isoillumination Plot Zonal Lumen Summary and Percentages at 25°C Zone Lumens % Luminaire 0-30 158.6 42.4 0-40 262.2 70.1 0-60 371.4 99.3 60-90 2.7 0.7 0-90 374.1 100.0 90-180 0.0 0.0 0-180 374.1 100.0 Zonal Lumens and Percentages at 25°C Zone Lumens % Luminaire 0-10 19.1 5.1 10-20 55.0 14.7 20-30 84.5 22.6 30-40 103.6 27.7 40-50 86.8 23.2 50-60 22.4 6.0 60-70 1.8 0.5 70-80 0.9 0.2 80-90 0.1 0.0 Report No. 100982670CRT-002 page 7 of 7 Date: November 29, 2012 Picture (not to scale) CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Vladimir Kozak Jeffrey Davis Associate Engineer Senior Associate Engineer Lighting Division Lighting Division Attachment: None Project: Fixture Type: Location: Contact/Phone: 1 of 4 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed Printed in U.S.A. ©2015 - 2017 Acuity Brands Lighting, Inc. Rev. Rev. 05/22/17 G1.10.4G2 2” IC 600 AND 1000 LUMENS LED ROUND DOWNLIGHT CONE 2LEDTRIM G2 DC PRODUCT DESCRIPTION 2 inch aperture recessed downlight is IC rated for insulated or non-insulated applications • Luminaire produces up to 1000 lumens and is available with optical distributions approximating that of 75W MR16 halogen lamps • Low profile form factor allows luminaire to fit in 2 x 6 construction • Designed to provide 50,000 hours of life • 5 year limited warranty on LED Components. ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT • No harmful ultraviolet or infrared wavelengths • No lead or mercury, RoHS compliant • Comparable light output up to a 75W MR16 halogen lamp PRODUCT SPECIFICATIONS LED Light Engine Exceptional fixture to fixture color consistency within a 3-step MacAdam ellipse • 2700K, 3000K, 3500K, and 4000K color temperatures are available with 80 CRI or 90 CRI minimum. Modular Optics Available with field interchangeable optics in 18° Spot, 24° Narrow Flood, or 40° Flood distributions. Aesthetic Trim Trim features die cast beveled knife edge trim ring for clean ceiling interface available in white, black, satin nickel, or brushed bronze • Spun aluminum reflectors are available in clear, haze, wheat haze, black and white finishes. LED Driver Choice of dedicated 120 volt (120) driver or universal voltage (MVOLT) driver that accommodates input voltages from 120-277 volts AC at 50/60Hz • Power factor > 0.9 • Dedicated 120 volt driver (120) is dimmable with the use of most incandescent, magnetic low voltage and electronic low voltage dimmers • Universal voltage driver (MVOLT) is dimmable with the use of most 0-10V protocol dimmers • For a list of compatible dimmers, see JUNO2ING2-DIM. Life Rated for 50,000 hours at 70% lumen maintenance. Labels ENERGY STAR® Certified • 90CRI fixtures are certified to the high efficacy requirements of California T24 JA8-2016 • Meets energy code Air Leakage requirements per ASTM E283 • UL and cUL listed for wet locations. Junction Box Includes (2) ½” knock-outs equipped with pryout slots • Push-in electrical connectors for field connections. Mounting Remodel style plaster frame installs from below the ceiling and accommodates ceiling thicknesses from ½” to 1” • For thicker ceilings up to 1 ½”, order 2JCTA150 • New Construction mounting frame, 2NCMF, is also available with Patented (US Patent D552,969) Real Nail 3® telescoping bar hangers to position fixture and locate wiring prior to ceiling installation • Recommend a minimum of 5.5” cavity depth to install properly • Flexible supply is recommended and non-flexible supply requires top access. Specifications subject to change without notice. Dedicated 120V (120)Universal Voltage (MVOLT) Voltage 120 120 277 Input Power 7.5 (±5%) 7.2 7.5 (±5%) Input Current .06 .06 .03 Frequency 50/60Hz 50/60Hz Power Factor >0.9 >0.9 >0.9 ENGINEERING DATA (600L) Dedicated 120V (120)Universal Voltage (MVOLT) Voltage 120 120 277 Input Power 11.5 (±5%) 10.9 11.4 (±5%) Input Current .10 .09 .04 Frequency 50/60Hz 50/60Hz Power Factor >0.9 >0.9 >0.9 ENGINEERING DATA (1000L) Downlight Cone Finishes DIMENSIONS 11 9/16” 4 1/8” 3 1/8” 2 5/8” CEILING CUTOUT 2” APERTURE HZSN BWH CWH WWH WHZBZ HZWH BBL 7” 2 of 4 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed Printed in U.S.A. ©2015 - 2017 Acuity Brands Lighting, Inc. Rev. Rev. 05/22/17 Example: 2LEDDRIVER G2 06LM 120 FRPC Series Generation Lumens Voltage Driver 2LEDDRIVER Juno Recessed 2” Driver G2 Generation 2 06LM 600 Nominal Lumens 120 120V FRPC Forward/Reverse Phase Cut 10LM 1000 Nominal Lumens MVOLT Multi-Volt (120- 277V) ZT 0-10V Dimming Note: 120V must be ordered with FRPC. MVOLT must be ordered with ZT ORDERING INFORMATION DRIVER AND TRIM EACH ORDERED SEPARATELY. DRIVER: TRIM: ACCESSORIES Catalog No.Description 2NCMF New Construction Mounting Frame with Real Nail® 3 bar hangers 2JCTA150 Thick Ceiling adapter for 1” - 1½” thick ceiling LEDOPTIC2 SP 18° Spot Optic LEDOPTIC2 NFL 24° Narrow Flood Optic LEDOPTIC2 FL 40° Flood Optic TRIM/LED ASSEMBLY MOUNTING FRAME/DRIVER ASSEMBLY Note: Driver assembly only intended for use with Gen2 LED trim modules. Not backward compatible with previous generation. Example: 2LEDTRIM G2 DC 27K 80CRI FL BBL Series Generation Trim Designation Color Temperature CRI Distribution Trim Finish 2LEDTRIM Juno Recessed 2” LED Trim G2 Generation 2 DC Downlight Cone 27K 2700K 80CRI 80+ CRI FL Flood BBL Black Baffle, Black Trim Ring 30K 3000K 90CRI 90+ CRI NFL Narrow Flood BWH Black Baffle, White Trim Ring 35K 3500K SP Spot CWH Clear Alzak Baffle, White Trim Ring 40K 4000K HZWH Haze Baffle, White Trim Ring WWH White Baffle, White Trim Ring 12 5/8” 15 15/16” 10 13/64” 13 1/2” will expand to 25” (Reduces to 9 1/8” with breakaway feature) 2NCMF 2JCTA150 G1.10.4G2 2” IC 600 AND 1000 LUMENS LED ROUND DOWNLIGHT CONE 2LEDTRIM G2 DC 3 of 4 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed Printed in U.S.A. ©2015 - 2017 Acuity Brands Lighting, Inc. Rev. Rev. 05/22/17 PHOTOMETRICS AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'55 50 465'35 32 29 6'24 22 207'20 18 178'16 14 13 9'12 11 1010'9 8 7 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°718 N/A 92.80-40°762 N/A 98.50-60°774 N/A 100.0 0-90°774 N/A 100.0 LUMINANCE (Average cd/m2) Degrees Average Luminance 45°6383 55°145565°075°0 85°0 INITIAL FOOTCANDLES(One Unit, 7.5W, 19.6° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'248.3 1.46'110.3 2.18'62.1 2.810'39.7 3.512'27.6 4.1 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 3972 5 3449 15 1007 25 318 35 53 45 12 55 2 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162131Catalog No: 2LEDTRIM G2 DC 35K 80CRI SP CWH (600L), Clear Cone with Spot Optic Luminaire Spacing Criteria: 0.34 Luminaire LPW: 103 800 1600 2400 3200 4000 0°15° 30° 45° 60° 75° 90° LUMINANCE (Average cd/m2) Degrees Average Luminance 45°5900 55°178565°075°0 85°0 AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'53 48 435'34 30 286'23 21 197'19 17 168'15 14 129'11 10 910'8 8 7 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°686 N/A 91.80-40°735 N/A 98.30-60°747 N/A 100.0 0-90°747 N/A 100.0 INITIAL FOOTCANDLES(One Unit, 7.5W, 24.3° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'185.2 1.7 6'82.3 2.68'46.3 3.410'29.6 4.3 12'20.6 5.2 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 2963 5 2681 15 1032 25 344 35 64 45 11 55 3 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162136Catalog No: 2LEDTRIM G2 DC 35K 80CRI NFL CWH (600L), Clear Cone with Narrow Flood Optic Luminaire Spacing Criteria: 0.42 Luminaire LPW: 100 600 1200 1800 2400 3000 0°15° 30° 45° 60° 75° 90° LUMINANCE (Average cd/m2) Degrees Average Luminance 45°1115755°1785 65°075°085°0 AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'54 48 435'35 31 286'24 21 19 7'20 17 158'15 14 129'12 10 9 10'9 8 7 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°644 N/A 83.10-40°752 N/A 97.10-60°775 N/A 100.00-90°775 N/A 100.0 INITIAL FOOTCANDLES(One Unit, 7.5W, 35.7° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'104.3 2.66'46.4 3.98'26.1 5.210'16.7 6.412'11.6 7.7 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 1669 5 1524 15 968 25 519 35 167 45 21 55 3 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162141 Catalog No: 2LEDTRIM G2 DC 35K 80CRI FL CWH (600L), Clear Cone with Flood Optic Luminaire Spacing Criteria: 0.58Luminaire LPW: 103 400 800 1200 1600 2000 0°15° 30° 45° 60° 75° 90° Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field. Multiplier:80 CRI 90 CRI 27K = .94 27K = .8330K = .97 30K = .86 35K = 1.00 35K = .8840K = 1.03 40K = .90 G1.10.4G2 2” IC 600 AND 1000 LUMENS LED ROUND DOWNLIGHT CONE 2LEDTRIM G2 DC 4 of 4 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed Printed in U.S.A. ©2015 - 2017 Acuity Brands Lighting, Inc. Rev. Rev. 05/22/17 AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'83 75 695'53 48 44 6'37 33 317'30 27 258'23 21 20 9'18 16 1510'13 12 11 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°1085 N/A 92.80-40°1151 N/A 98.50-60°1168 N/A 100.0 0-90°1169 N/A 100.0 LUMINANCE (Average cd/m2) Degrees Average Luminance 45°9638 55°219765°075°0 85°0 INITIAL FOOTCANDLES(One Unit, 11.5W, 19.6° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'374.8 1.46'166.6 2.18'93.7 2.810'60.0 3.512'41.6 4.1 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 5997 5 5209 15 1520 25 481 35 80 45 18 55 3 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162131RCatalog No: 2LEDTRIM G2 DC 35K 80CRI SP CWH (1000L), Clear Cone with Spot Optic Luminaire Spacing Criteria: 0.34 Luminaire LPW: 102 1200 2400 3600 4800 6000 0°15° 30° 45° 60° 75° 90° LUMINANCE (Average cd/m2) Degrees Average Luminance 45°9027 55°273265°075°0 85°0 AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'81 73 665'52 47 436'36 32 307'29 26 248'23 21 199'18 16 1410'13 12 11 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°1049 N/A 91.80-40°1124 N/A 98.30-60°1143 N/A 100.0 0-90°1143 N/A 100.0 INITIAL FOOTCANDLES(One Unit, 11.5W, 24.3° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'283.3 1.7 6'125.9 2.68'70.8 3.410'45.3 4.3 12'31.5 5.2 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 4533 5 4102 15 1579 25 526 35 98 45 17 55 4 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162136RCatalog No: 2LEDTRIM G2 DC 35K 80CRI NFL CWH (1000L), Clear Cone with Narrow Flood Optic Luminaire Spacing Criteria: 0.42 Luminaire LPW: 99 900 1800 2700 3600 4500 0°15° 30° 45° 60° 75° 90° LUMINANCE (Average cd/m2) Degrees Average Luminance 45°1718255°2750 65°075°085°0 AVERAGE INITIAL FOOTCANDLESMultiple Units (Square Array, 60’x60’ room) Reflectances: Ceiling 80%, Wall 50%, Floor 20% Spacing RCR1 RCR3 RCR5 4'84 74 665'53 47 426'37 33 29 7'30 27 248'24 21 199'18 16 14 10'13 12 11 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0-30°991 N/A 83.10-40°1159 N/A 97.10-60°1193 N/A 100.00-90°1193 N/A 100.0 INITIAL FOOTCANDLES(One Unit, 11.5W, 35.7° Beam) Distance to Illuminated Plane (Feet)Footcandles Beam Center Beam Diameter 4'160.7 2.66'71.4 3.98'40.2 5.210'25.7 6.412'17.9 7.7 CANDLEPOWER DISTRIBUTION(Candelas) DegreesVertical 0° 0 2571 5 2346 15 1490 25 799 35 256 45 32 55 4 65 0 75 0 85 0 90 0 PHOTOMETRIC REPORTTest Report#: PT07162141R Catalog No: 2LEDTRIM G2 DC 35K 80CRI FL CWH (1000L), Clear Cone with Flood Optic Luminaire Spacing Criteria: 0.58Luminaire LPW: 104 500 1000 1500 2000 2500 0°15° 30° 45° 60° 75° 90° Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field. Multiplier:80 CRI 90 CRI 27K = .94 27K = .8330K = .97 30K = .86 35K = 1.00 35K = .8840K = 1.03 40K = .90 G1.10.4G2 2” IC 600 AND 1000 LUMENS LED ROUND DOWNLIGHT CONE 2LEDTRIM G2 DC PHOTOMETRICS