HomeMy WebLinkAbout25-E0.02 ELECTRICAL SITE PLAN a--+ GENERAL ELECTRICAL SITE NOTES U ._ 0) 1. ALL INFORMATION SHOWN ON THIS SITE PLAN DRAWING IS FOR THE FINAL COMPLETE INSTALLATION.ELECTRICAL }+ CONTRACTOR TO COORDINATE WITH THE GENERAL CONTRACTOR TO INSTALL AS MUCH AS POSSIBLE UNDERGROUND M F N AND UNDER THE SLAB WHILE THE BUILDING IS BEING CONSTRUCTED AND THE SITEWORK/GRADING IS BEING DONE. • LLI E ONEW STORAGE STUB UP,CAP,AND LABEL ALL CONDUITS INSTALLED DURING THE INITIAL PHASES OF CONSTRUCTION,AND UNTIL FINAL w GARAGE LOCATION CONNECTIONS ARE MADE FOR THE COMPLETED INSTALLATIONS. LCL 2. SEE ARCHITECTURAL,MECHANICAL,FIRE PROTECTION,LANDSCAPE,AND CIVIL SITE PLANS FOR ADDITIONAL SITE � Q TYP. PROPOSED UTILITY INFORMATION AND REQUIREMENTS.COORDINATE SITE WORK WITH THE GENERAL CONTRACTOR AND OTHER TRADES. C SITE LIGHTING 11 _ _ _ _—E__ ___ ___ E_______ TRANSFORMER 2 FIXTURE(TYP.)O TB1 a LOCATION O 3. ELECTRICAL TERMINATION AT SERVICE EQUIPMENT,LIGHTING,AND ALL OTHER ELECTRICAL WORK,INCLUDING /V^I'/' t T4 T4 T4 ELECTRICAL CONDUITS FOR FEEDERS AND SPECIAL SYSTEMS,AS INDICATED ON THIS DRAWING,TO BE PERFORMED BY W r Z ] c 1 THE ELECTRICAL CONTRACTOR AS PART OF THEIR SCOPE OF WORK. t O T I „� 6 4. REPAIR LANDSCAPE AND PARKING AREAS THAT ARE DISTURBED BY THIS SCOPE OF WORK.AREAS SHALL BE RETURNED Z .o I SITE LIGHTING ----E------E- --- E -- -E- - --E---------E------- -a 4 m TO THEIR ORIGINAL FIXTURE(TYP.) CONDITION UNLESS NOTED OTHERWISE BY THIS SCOPE OF DESIGN.REFER TO OTHER DISCIPLINE d) L-E- PLANDRAWINGS.COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES. IIII 14 O E c oN7 II ' 5. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRING,CONDUIT,BOXES,METERING,DEVICES,ETC.FOR COMPLETE Q � 7 13 i AND OPERATIONAL BUILDING SERVICE INSTALLATION AND OPERATION. -c Co E� C O 5 15 _ II -- 6. PROVIDE ADEQUATELY SIZED PULLBOXES FOR POWER,LIGHTING,AND SPECIAL SYSTEMS,AS NEEDED.STUB UP N \\\\\ T2 TVP. - 5 15 CONDUIT IN PULLBOX,CAP AND LABEL,AS NEEDED.PULLBOX COVER SHALL READ"ELECTRICAL,""COMMUNICATIONS," L N E TB1 E TYp OR"LIGHTING,"AS APPROPRIATE.PROVIDE A PILLBOX AFTER(2)90-DEGREE BENDS OR AN ACCUMULATION OF Q 1D \ - -- -TS1 B1 I I 120-DEGREES OF TOTAL PATHWAY DEVIATION FROM A STRAIGHT LINE BETWEEN ACCESS POINTS.LOCATE PULLBOXES II SUCH THAT THERE IS A MAXIMUM OF 400'-0"BETWEEN EACH ACCESS POINT.DO NOT LOCATE IN TRAFFIC AREAS,UNLESS T3 T SPECIFICALLY MANUFACTURED TO HANDLE TRAFFIC. PC O 7. CONDUITS SHALL BE CONCEALED AS MUCH AS PRACTICABLE.CONDUITS ROUTED EXPOSED ON THE EXTERIOR OF THE BUILDING SHALL BE ROUTED AS INCONSPICUOUSLY AS POSSIBLE AND PAINTED TO MATCH THE SURROUNDING SURFACE. a- r 8. REFER ALSO TO ELECTRICAL ONE-LINE DIAGRAM,EO.03,FOR ADDITIONAL INFORMATION REGARDING THE SERVICE a WHICH IS A PART OF THIS SCOPE OF WORK. T4 9. RUN ALL CONDUITS UNDER PAVEMENT AND LANDSCAPED AREAS 36"MINIMUM BELOW FINISHED GRADE.COMPLY WITH ����T 1j1jttl THE NATIONAL ELECTRICAL CODE(NEC). ���O N•••••q N7j�i,' I I 6 6 I 10. CONDUIT ROUTING(S)SHOWN ON THE PLAN ARE FOR GENERAL INTENT ONLY.ALL CONDUIT ROUTING SHALL BE FIELD *' V (p II BUILDING MOUNTED COORDINATED WITH THE GENERAL CONTRACTOR,OTHER TRADES,AND THE FIELD CONDITIONS.RUN CONDUITS IN THE LIGHT FIXTURE(TYP. I SAME TRENCH AS OTHER UTILITIES,AS MUCH AS PRACTICABLE.MAINTAIN ALL REQUIRED SEPARATIONS FROM OTHER 99PE UTILITIES.STUB UP AND LABEL THE CONDUITS AT BOTH ENDS,AS REQUIRED.TYPICAL FOR ALL SITE CONDUIT RUNS. I \ G T4 10 3 2 I I T4 11. E.C.SHALL PROVIDE PULLWIRE IN ALL EMPTY SITE CONDUITS. I 12. DO NOT INSTALL CONDUITS ON THE SITE UNTIL THE ROUGH SITE GRADING HAS BEEN COMPLETED.COORDINATE WITH 19 THE GENERAL CONTRACTOR. I I I TYp. 13. COORDINATE AND LOCATE ALL UTILITIES PRIOR TO ANY EXCAVATION.CALL FOR UTILITY LOCATES AND COORDINATION �I J OF WORK PRIOR TO ALL EXCAVATIONS.E.C.RESPONSIBLE FOR COORDINATING ALL SERVICE INSTALLATION TE�� I \ LU I REQUIREMENTS WITH THE SERVING UTILITIES. SITELIGHTING II I �� SITE LIGHTING Engineering 11 0 FIXTURE MOUNTED 14. COMMUNICATIONS TERMINATION AT SERVICE ENTRANCE EQUIPMENT IN THE BUILDING,AND ALL OTHER FIXTURE(TYP.) � � IN RETAINING WALL COMMUNICATIONS WORK AS INDICATED IN THIS DRAWING TO BE PERFORMED BY THE COMMUNICATIONS CONTRACTOR T4 = T4 (TYPICAL ON EAST AS PART OF THEIR SCOPE OF WORK. LLC I \ I I SIDE OF THE LOT) 16 ELECTRICAL ENGINEERING CONSULTANTS E � J � 15. COMMUNICATIONS CONTRACTOR SHALL PROVIDE ALL CABLING,CONDUIT,RACEWAYS,ETC.FOR A COMPLETE AND Z J I I OPERATIONAL BUILDING COMMUNICATIONS SERVICE INSTALLATION. VauP.O P.O.BOX 50459487 ghn, t o I � Phoe(406)9648 523 � w 16. REFER TO LIGHT FIXTURE SCHEDULE FOR EXTERIOR FIXTURES,E5.01,FOR ADDITIONAL INFORMATION ON THE SITE 5 15 i i LIGHTING. TYP c0 I I Q 17. ALL SITE LIGHTING CIRCUITS SHALL BE(2#4,1#8 GND)1-1/2"C,UNLESS NOTED OTHERWISE.EXTERIOR BUILDING MOUNTED LIGHTING AND SIGNAGE SHALL BE(2#8,1#8 GND)3/4"C,UNLESS NOTED OTHERWISE. C I 12 = I 12 T 18. ALL LIGHTING CIRCUITS SHALL BE ROUTED VIA THE LIGHTING CONTACTOR FOR CONTROL,UNLESS NOTED OTHERWISE. _- _E___C = _ _- EJJ_ =i FLAG NOTES THIS SHEET: 1 4 3 ) APPROXIMATE LOCATION OF MAIN SWITCHBOARD(MSB)IN ELECTRICAL 126. p ❑ I D\„ B 17 O LOCATION FOR NEW ELECTRICAL SERVICE TRANSFORMER.COORDINATE THE LOCATION WITH THE FIELD CONDITIONS �❑ AND UTILITY.NEW TRANSFORMER SHALL BE SET ON A CONCRETE PAD.COORDINATE EXACT LOCATIONS AND T4 REQUIREMENTS WITH THE SERVING UTILITY.INSTALL TRANSFORMER SUCH THAT MINIMUM WORKING CLEARANCES ARE I 0 MAINTAINED AROUND THE TRANSFORMER AND IN FRONT OF THE SERVICE ENTRANCE EQUIPMENT.REFER TO TYPICAL :a w TRANSFORMER PAD GROUNDING DETAIL,E5.02,FOR GROUNDING INFORMATION.REFER ALSO TO ELECTRICAL ONE-LINE DIAGRAM,EO.03,FOR ADDITIONAL INFORMATION. CONDUITS WITH SERVICE ENTRANCE CONDUCTORS FROM THE METER/CT CABINET LOCATION TO THE MSB INSIDE THE BUILDING.CONDUITS SHALL BE UNDERGROUND IN SCHEDULE 40 PVC CONDUIT IN A SAND-ENCASED DUCTBANK. 1 INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 70.REFER TO SERVICE ENTRANCE POWER DUCTBANK DETAIL, 1 T4 E5.02,FOR ON INFORMATION. ®� O CONDUITS WITH PULLWIRE FOR NEW COMMUNICATIONS SERVICE ENTRANCE.ROUTE THE CONDUITS FROM APPROXIMATELY 5'-0"OUTSIDE THE BUILDING(AWAY FROM THE FOUNDATION)AND STUB-UP INTO DATA/MDF 128. REFER ALSO TO COMMUNICATION TRENCH DETAIL,E5.02,FOR ADDITIONAL INFORMATION.COORDINATE THE COMMUNICATIONS SERVICE ENTRANCE WITH THE SERVING UTILITY AND OWNER'S COMMUNICATIONS PERSONNEL. i � u � F O LOCATION FOR NEW STORAGE GARAGE.GARAGE WILL HAVE A PANEL LOCATED INSIDE TO FEED LIGHTS AND �- 5 15 RECEPTACLES. I _ TYR O FEEDER TO NEW STORAGE GARAGE FROM THE MSB IN ELECTRICAL 126.COORDINATE ROUTING WITH THE FIELD CONDITIONS. �i h CDSITE LIGHTING O NEW MONUMENT SIGN.PROVIDE FEEDER AND TERMINATE A BELOW GRADE JUNCTION BOX LOCATED WITHIN 6'-0"OF FIXTURE(TYP.) 12 j I THE SIGN.COORDINATE LOCATION AND CONNECTION REQUIREMENTS WITH THE SIGN INSTALLER AND THE SIGN 11 1A 8 PROVIDED.CONNECT TO CIRCUIT,AS SHOWN. O I I wi O8 FEEDER TO THE MONUMENT SIGN FROM PANEL L1A AND THE LIGHTING CONTACTOR IN ELECTRICAL 126.COORDINATE \ ROUTING WITH THE FIELD CONDITIONS. r _ O PROVIDE PHOTOCELL AS MANUFACTURED S AM TOR#2 SERIES,COMPLETE WITH ADJUSTABLE SHIELD,ADJUST FOR -"�—E-- - -- --—-- -- --—- "DUSK ON,DUSK OFF"OPERATION,120VAO, PST,20 AMP.MOUNT PHOTOCELL AT THE ROOFLINE,FACING IN THE Bl NORTHERLY DIRECTION.INSTALL;PER THE MANUFACTURER'S RECOMMENDATIONS. ] Q MONUMENT SIGN 7 O FO 10 REFER TO LIGHTING FLOOR PLANS,E1.01 THROUGH E1.04,FOR LOCATIONS,QUANTITIES,AND FIXTURE TYPES FOR THE BUILDING MOUNTED LIGHT FIXTURES.CONTROL SHALL BE PHOTOCELL ON/TIMECLOCK OFF. rr 11 REFER TO POLE BASE DETAIL,E5.02,FOR ADDITIONAL INFORMATION REGARDING THE SITE LIGHTING FIXTURES. FIXTURE AND POLE ASSEMBLY SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS.TYPICAL FOR cc ALL THE SITE LIGHTING FIXTURES,EXCEPT FOR THE POLES MOUNTED ON THE RETAINING WALL(SEE FLAG NOTE 16 BAXTER LANE BELOW). 12 CONNECT SITE LIGHTING AND SIGNS TO CIRCUITS,AS INDICATED,VIA THE LIGHTING CONTACTOR.CONTROL FOR THE 0 REVI5ION 5GHEWLE BAXTER LANE SITE LIGHTING AND SIGNS SHALL BE PHOTOCELL ON/TIMECLOCK OFF,UNLESS NOTED OTHERWISE OR DIRECTED # DESCRIPTION DATE OTHERWISE BY THE PROJECT MANAGER AND HOTEL REPRESENTATIVE.INSTALL PER THE MANUFACTURER'S RECOMMENDATIONS AND COORDINATE INSTALLATION WITH THE BUILDING MANAGEMENT SYSTEM.COORDINATE 1 CITY COMMENTS .21.2 ROUTING OF THE FEEDERS WITH THE FIELD CONDITIONS. n 13 CONDUIT WITH PULL WIRE FUTURE ELECTRIC VEHICLE(EV)CHARGING STATIONS.ROUTE THE CONDUIT FROM 0 ELECTRICAL 126 TO THE EDGE OF THE PARKING AREA,AS INDICATED.STUB-UP,CAP AND LABEL THE CONDUITS. / D PAD-MOUNTED CT METERING CABINET I DISCONNECT.CABINET PROVIDED AND INSTALLED .Zm1 BY THE E ECTR CAL CONTRA TOR.C O E RDINA E ONCRE PAD W TH THE GENERAL CONTRACTOR.OWNER INSTALL PER THE n MANUFACTURER'S RECOMMENDATIONS AND UTILITY COMPANY REQUIREMENTS. m 15 PROVIDE 10/2 CONTROL WIRE FOR THE EXTERIOR SITE LIGHTING POLE-MOUNTED FIXTURES TO PROVIDE DIMMING CAPABILITY.ROUTE CONTROL WIRE DIRECTLY TO THE DIMMING SWITCH(ES)LOCATED IN ELECTRICAL 126.DO NOT RUN THE DIMMING CONTROL WIRE THROUGH THE LIGHTING CONTACTOR OR ANY OTHER CONTROLS. POLES ALONG OF ELECTRICAL SITE PLAN 19 16 THE POLE SHALL{BE 25'OE EASTSTO MATCH THE EST OF THE FIXTURES ON THE SITE.IDE OF THE PROPERTY SHALL BE MOUNTED IN THEENG AD ADJUST POLE HEIGHT FORT EWALL.OVELHPOLES IN THE RETAINING WALL.REFER TO CIVIL AND STRUCTURAL DRAWINGS FOR MOUNTING DETAILS.ROUTE CONDUIT ON E0.02 V=30'-0" THE EAST SIDE OF THE WALL AND THEN PASS INTO THE WALL AT EACH LIGHT.FIELD COORDINATE ROUTING OF THE FEEDER BETWEEN FIXTURES WITH THE WALL CONSTRUCTION AND THE FIELD CONDITIONS.ROUTE AS CLOSE TO THE Z SITE PLAN FEEDER SCHEDULE WALLAS POSSIBLE TO AVOID CONFLICTS WITH LANDSCAPING.TYPICAL FOR(8)POLE-MOUNTED FIXTURES ON THE EAST 4 SIDE OF THE PROPERTY. 17 CONDUIT WITH PULLWIRE FOR NEW CABLE TV(CAN)SERVICE ENTRANCE.ROUTE CONDUIT FROM APPROXIMATELY OUNDERGROUND SECONDARY BY UTILITY COMPANY.ELEC.CONTRACTOR TO COORDINATE 10'-0"OUTSIDE BUILDING(AWAY FROM THE FOUNDATION)AND STUB-UP INTO DATA/MDF 128.COORDINATE CAN O Z z WITH THE UTILITY AND PROVIDE RACEWAY,AS REQUIRED.REFER TO ONE-LINE DIAGRAM. SERVICE ENTRANCE WITH THE SERVING UTILITY. 0 O2 8 SETS OF[(4#500MCM,1#350MCM GND)3-1/2"C]FROM METERING CABINET TO MSB INSIDE 16 PROVIDE WEATHERPROOF GFI RECEPTACLE AT THE SIGN FOR CONNECTION TO THE STANDARD CHARGER PROVIDED WITH THE BIRD SHOCK FLEX-TRACK SYSTEM.COORDINATE LOCATION FOR CONNECTION TO THE SYSTEM AND THE O (2)4"EMPTY CONDUITS WITH PULL LINE FOR COMMUNICATIONS SERVICE FROM THE UTILITY CHARGER SUPPLIED WITH THE SYSTEM SPECIFIED ON THE ARCHITECTURAL DRAWINGS.LOCATE THE RECEPTACLE$O THAT IT WILL NOT BE EASILY VISIBLE.CONNECT RECEPTACLE TO THE SIGN CIRCUIT AHEAD OF ALL LIGHTING CONTROLS.PROVIDE ALL CONNECTIONS,DEVICES,WIRING,ETC.FORA COMPLETE SYSTEM. 02#8,1#8 GND,3/4"C(SIGN-MONUMENT) N 19 FOR ALL SITE PLAN FEEDERS NEAR THE RETAINING WALL ON THE NORTH AND EAST SIDES,ROUTE CONDUITS AS CLOSE Z O 2#4,1#8 GND+10/2 WIRE,1-1/2"C(SITE LIGHTING-PARKING AREAS) 15 TO THE WALL AS POSSIBLE TO AVOID CONFLICTS WITH THE LANDSCAPING.COORDINATE ALL FEEDER ROUTING WITH THE FIELD CONDITIONS AND OTHER CONSTRUCTION DISCIPLINES. O O4#1,1#8GND,1-1/2"C(GARAGE BUILDING PANEL) p O z 7 (3)2"EMPTY CONDUITS WITH PULL LINE FOR FUTURE EV CHARGING STATIONS � OB (1)4"EMPTY CONDUIT WITH PULL LINE FOR CABLE TV(CATV)SERVICE FROM THE UTILITY NOTE:IT IS ACCEPTABLE TO INSTALL ONLY THE CONDUIT AT THE TIME OF THE SITE WORK AND INSTALL THE WIRE AND/OR CABLING DURING A LATER PHASE OF CONSTRUCTION. Project COORDINATE INSTALLATION WITH THE GENERAL CONTRACTOR.PROVIDE PULLWIRE IN ALL EMPTY CONDUITS. Date Drawn by tw Checked by tw 0 4" 8" I'-O" 0 2 0 1. 2 0 I - 2 - 0 2 0 2 - 1. 4 0 2 0 O - 0 1. 6, 2 0 10- 2 - 2