Loading...
HomeMy WebLinkAbout16-L2.2 IRRIGATION DETAILSProject Date Drawn by Checked byarchitectsNelson DreamDesignBuild621 2nd Avenue North Great Falls, MT 59401406.727.3286 NelsonArchitects.comNOT FOR CONST.REVISION SCHEDULE #DESCRIPTION DATE CONSTRUCTIONISSUED FOR6-21-24 23-012 GSG NGSBOZEMAN ATWELL HOTEL1851 BAXTER LANE, BOZEMAN MONTANA59715P L L C GOLF COURSE ARCHITECTURE IRRIGATION DESIGN LANDSCAPE ARCHITECTURE THUESEN STEINER NATHAN STEINER 143 G CNLADS APE ARCHITECTOMNTANA R EG ISTERED L2.2IRRIGATION DETAILSFINISH GRADE CURB OR BED PAVEMENT EDGE OF LATERAL PIPE PVC CLASS 200 PVC TEE AS SPECIFIED SWING JOINT AS SPECIFIED SPRAY HEAD NOZZLE MATCHED PRECIPITATION 1 TURF SPRAY HEAD DRIP EMITTER AT PLANT PVC LATERAL PIPE STAKE, AS REQUIRED 2 BE FLUSH WITH TOP OF MULCH. FPT BASE. BOTTOM OF EMITTER TO GPH TRUCHECK DRIP, EMITTER WITH MULCH, AS SPECIFIED PVC SCH. 40 SST TEE/ELL 1/2" 90° ELL BARBED INSERT FITTING 14" LONG MINIMUM, 48" LONG MAXIMUM. 1/2" DISTRIBUTION TUBING (RAINBIRD SPX-FLEX) TOPSOIL FINISH GRADE 1/2" MARLEX STREET ELL 1/2" 90° ELL BARBED INSERT FITTING NOTES: 3. PLACE EMITTER ON UPHILL SIDE OF PLANT ON SLOPES. 2. REFER TO DRIP SCHEDULE FOR NUMBER OF EMITTERS AND FLOW. 1. MINIMUM (2) EMITTERS PER PLANT UNLESS NOTED OTHERWISE. NOT TO SCALE12"NOT TO SCALE 2-1/2" 3" MIN.NOTES: TO BE USED. 1. DO NOT DRIVE REBAR THROUGH TABS ON SWING JOINT, STABILIZING BAR 5 TYPICAL QUICK COUPLER NOT TO SCALE BOX AS SPECIFIED 10" ROUND VALVE VALVE AS SPECIFIED QUICK COUPLING TO FIT NOTCH VALVE BOX STABILIZING BAR - 1" X 18" SCH 80 45° MAX. 30° MIN. AS SPECIFIED UNITIZED SWING JOINT FLOWLATERAL PIPE MAINLINE/ ONE EACH SIDE MIN. 2 CONC. BLOCKS, WASHED AGGREGATE 6" MIN. OF 3/4" COMPACTED SOIL AS SPECIFIED SCH 80 PVC TEE FINISH GRADE NOTES: 2. PROVIDE 1" MIN. SPACE BETWEEN BOTTOM OF VALVE BOX AND TOP OF MAINLINE. BETWEEN LID AND TOP OF AIR RELEASE VALVE. 1. ROTATE TEE ON MAINLINE AS NECESSARY TO ENSURE CLEARANCE IS PROVIDED 6 AIR RELIEF VALVE NOT TO SCALE AS SPECIFIED 1" GATE VALVE AIR RELEASE VALVE BERMAD 1"- C10 AS SPECIFIED SERVICE TEE 1" SCH 80 PVCPVC NIPPLE 1" CLOSE FINISH GRADE EACH CORNER BLOCKS, ONE MIN. 4 CONC. RISER AS SPECIFIED VALVE BOX & BASE 3/4" AGGREGATE 6" OF WASHED THRUST BLOCK 2SF CONCRETE 18"12"4 87 13 14 6 5 FLOW 16 3 1 2 11 12 17 9 15 10 9 TYPICAL ELECTRIC CONTROL VALVE NOT TO SCALE NOTES: VALVE SIZE CALLED FOR ON PLANS. 1. ADJUST SIZE OF PVC FITTINGS TO MATCH ELECTRIC LEGEND: BOX. 17. 1" MIN. SPACE BETWEEN LATERAL AND VALVE 16. MIN. 4 CONC. BLOCKS, ONE EACH CORNER. 15. VALVE ID TAG, AS SPECIFIED. ALL SPLICES IN VALVE BOX. 14. DBY WIRE CONNECTORS AS SPECIFIED, MAKE 13. PROVIDE 20 EXPANSION COILS EACH WIRE 12. FINISH GRADE 11. VALVE BOX AS SPECIFIED, RISER AS REQUIRED. 2" CLEARANCE BELOW VALVE. 10. 6" OF WASHED 3/4" AGGREGATE BASE, MAINTAIN 9. SOLVENT WELD PIPE TO LATERALS. 8. 3" X 2" SCH 80 1 PIECE REDUCER COUPLING 7. 2" X 4" SCH. 80 T.O.E. NIPPLE 6. 2" - T X T SCH. 80 UNION 5. 2" X 2" T.B.E. SCH 80 NIPPLE 4. ELECTRIC VALVE AS SPECIFIED 3. SCH 80 PVC T.O.E. NIPPLES AND ELBOW 2. SCH 80 PVC SERVICE TEE 1. MAINLINE DIAMETERS 5 PIPE FLOW 3/4" WASHED GRAVEL VALVE INLET SIZE. SCH 80 NIPPLES, 10 PIPE DIAMETERS NO VALVES, REDUCERS, OR ELBOWS IN THIS AREA FINISH GRADE EXTENSIONS AS SPECIFIED. VALVE BOX WITH 6" LOOPED WIRES. TO AIRCARD WITH SLC SPLICE. WATERPROOF WIRE CONNECTORS ON 18" 1" MIN. SPACE OVER MAINLINE SCH 80 PVC REDUCER AS REQUIRED. 3/4" WASHED GRAVEL 80 UNION SCHEDULE SUBMAINLINE VALVE INLET SIZE. SCHEDULE 80 NIPPLE TOE, CONCRETE SUPPORT BLOCKS, 4 PER BOX, MIN. GOPHER SCEEN. WRAP UP SIDES, OVER AT BOTTOM OF EACH BOX: 1/2" WIRE CLOTH CONNECTORS WATERPROOF WIRE NORMALLY OPEN MASTER VALVE, FLOW SENSOR. BACK TO CONTROLLER (SEE NOTE 1). PE39/98 CABLE IN 1" SCH 40 PVC CONDUIT NOT TO SCALE 8 MASTER VALVE AND FLOW SENSOR NOTES: 4. FLOW SENSOR ANGLE TO BE PER MANUFACTURER'S RECOMMENDATIONS. 3. MINIMUM DISTANCES BETWEEN ANY FITTING OR VALVE AND FLOW SENSOR ARE NOTED ABOVE. 2. FLOW SENSOR PIPE RUN SIZE SAME AS FLOW SENSOR SIZE NOTED ON PLANS. IN LAYING DISTANCE FROM FLOW SENSOR TO IRRIGATION CONTROLLER. 1. 1 PAIR, TWISTED SHIELDED CABLE-MINIMUM CONDUCTOR SIZE 20 AWG. DO NOT EXCEED 2,000 FEET NOTES: 2. THIS DETAIL FOR VALVES 2-1/2" AND SMALLER. 1. VALVE TO BE SUPPORTED BY GRAVEL, PROVIDE BLOCK SHIM AS REQUIRED. FINISH GRADE AS SPECIFIED VALVE BOX LINE SIZE GATE VALVE LATERAL AND VALVE BOX 1" MIN. SPACE BETWEEN MAINLINE PIPE ONE EACH CORNER MIN. 4 CONC. BLOCKS, 3/4" AGGREGATE BASE 6" OF WASHED MANUAL ISOLATION VALVE7 NOT TO SCALE TYPICAL DRIP CONTROL VALVE10 NOT TO SCALE12"18"12 11 19. 1" BALL VALVE 18. PRESSURE REGULATING DRIP FILTER, SEE NOTES. 17. 1" MIN. SPACE BETWEEN LATERAL AND VALVE BOX. 16. MIN. 4 CONC. BLOCKS, TWO EACH SIDE. 15. VALVE ID TAG, AS SPECIFIED. 14. DBY WIRE CONNECTORS AS SPECIFIED, MAKE ALL SPLICES IN VALVE BOX. 13. PROVIDE 20 EXPANSION COILS EACH WIRE. 12. FINISH GRADE. 11. JUMBO VALVE BOX AS SPECIFIED, RISER AS REQUIRED. VALVE. 10. 6" OF WASHED 3/4" AGGREGATE BASE, MAINTAIN CLEARANCE BELOW 9. SOLVENT WELD PIPE TO LATERALS. 8. 2" X 1" SCH 80 1 PIECE REDUCER COUPLING. 7. 1" X 4" SCH. 80 T.O.E. NIPPLE. 6. 1" - T X T SCH. 80 UNION. 5. 1" X 1" T.B.E. SCH 80 NIPPLE. 4. ELECTRIC VALVE AS SPECIFIED. 3. 1" SCH 80 PVC ELBOW & NIPPLES, LENGTH AS REQUIRED. 2. SCH 80 PVC SERVICE TEE. 1. MAINLINE. LEGEND: NOTES: 2. PRESSURE REGULATING FILTER: SEE LEGEND. FOR ON PLANS. 1. ADJUST SIZE OF FITTINGS TO MATCH ELECTRIC VALVE SIZE CALLED 1 2 5 3 6 10 17 9 8 7 17 18 4 15 13 14 19 13 CONTROLLER 18" BELOW FINISH GRADE. 1. ROUTE CONDUIT THROUGH FLOOR AND SWEEP THROUGH FOUNDATION AT NOTES: LEGEND: 1 PVC SCH 40 CONDUIT AND FITTINGS, SIZE AS SPECIFIED.2 WIRES TO REMOTE CONTROL VALVES, MASTER VALVE, AND FLOW SENSOR.3 MODULAR HYBRID CONTROLLER, AS SPECIFIED. INSIDE WALL MOUNT. STANDARD MODULE FOR 4-STATION CONTROLLER. EXPANSION MODULES. STANDARD 120 V PLUG. 120 VAC, 60 HZ INTERNAL TRANSFORMER. 4 5 6 7 NOT TO SCALE INSIDE CONTROLLER CHASSIS INSIDE FRONT COVER 1 2 3 .MOUNTING WALL 1 6 4 5 37 12 TRENCHING DETAILS AND LOCATED ON AS-BUILT PLANS. SHALL BE MADE IN VALVE BOXES WIRING AND MAINLINE. ALL SPLICES 6" ABOVE ALL DIRECT BURIAL 120 V. INTERVALS. USE 6" WIDE MARKING TAPE TAPE & BUNDLE ALL WIRING AT 10' PULL BOXES AS REQUIRED. SLEEVES SHALL BE IN CONDUIT. PROVIDE WIRING UNDER PAVEMENT & THROUGH WITH MARKER TAPE AS ABOVE. ALL ALL 120 V. WIRING SHALL BE IN CONDUIT AFTER MAKING CONNECTIONS. GREATER THAN 30°. UNTIE ALL LOOPS AT ALL CHANGES IN DIRECTION TIE A LOOSE 20" LOOP IN WIRING SECTION CONDUIT PLAN CONDUIT VOLTAGE ONLY SECTION-LOW DIRECT BURY PLAN DIRECT BURY PLANS FINISH GRADE LOOP O.C. MAX. TIES 10' LATERAL SECTIONS FINISH GRADE LATERAL MAINLINE BEDDING. MARKING TAPE 120 V. WIRE IN CONDUIT TRENCH PIPE IN LATERAL SNAKE ALL FINISH GRADE 12" 18"12"18"12" 12" MIN. 30" WIRE VOLTAGE LOW NOT TO SCALE THE 120 V. WIRE AT MAINLINE PIPE DEPTH. 2. LOW VOLTAGE WIRE TO BE BUNDLED AND INSTALLED OPPOSITE AS SHOWN ON THE PLANS. 1. 120 V. WIRE TO BE INSTALLED ON THE SIDE OF THE MAINLINE NOTES: FINISH GRADE MARKING TAPE CONTINUOUS MARKING TAPE 11 TYP. MAINLINE DRAIN NOTES: FINISH GRADE BOX AS SPECIFIED 10" ROUND VALVE AGGREGATE ¾" WASHED LENGTH AS REQUIRED 4" PVC RISER COMPACTED SOIL ONE EACH SIDE MIN. 2 CONC. BLOCKS , TURN DOWN AT ENDS SUPAC 4NP CLOTH, DRAIN TO DAYLIGHT 1-1/2" CL 200 PVC SCH 80 PVC ELBOW 1-1/2" GATE VALVE SCHED. 80 MALE ADAPTOR AGGREGATE 1 CY OF 1-1/2" WASHED DRY WELL WITH MIN. NOT TO SCALE TEE ON BOTTOM SCH 80 PVC SERVICE MAINLINE WITH 1-1/2" TO STEEL PIPE 36" BEFORE END OF PIPE. 1. DRAIN TO DAYLIGHT WHEREVER POSSIBLE. TRANSITION SCH 80 PVC T.O.E. NIPPLE T.O.E. NIPPLE SCH 80 PVCMIN.3" WIRE LOW VOLTAGE 2" MIN.12" MINIMUM1/4" MIN.4 ROOT WATERING SYSTEM NOT TO SCALE 4. FOLLOWING INSTALLATION, FILL BASKET WITH PEA GRAVEL. 3. INSTALL 4"-6" OF 3/4" WASHED ROCK AROUND UNIT. 2. TOP OF GRATE TO MATCH TOP OF MULCH. 1. SPACE UNITS EVENLY AROUND ROOTBALL. NOTES: 4" WIDE X 18" LONG RIGID LATERAL PIPE. PVC SCH 40 TEE OR ELBOW. MALE NPT INLET. FUNNY PIPE SWING ASSEMBLY LOCKING GRATE. TOP OF MULCH. BUBBLER. ROOT WATERING SYTEM. LEGEND: 1 2 33 4 55 6 77 8 9 BASKET WEAVE CANISTER. 1 2 4 3 5 6 78 918"TREE ROOT BALL10 10 POSSIBLE 60-90° IF INSTALL AT . SAME SIZE AS MASTER VALVE 12" LONG SCH 80 PVC NIPPLE, MALE ADAPTER MAINLINE W/ PVC MASTER VALVE SAME SIZE AS GATE VALVE COVER18" MINIMUM DRIP LATERAL FLUSH VALVE3 NOT TO SCALE 1 2 3 4 5 6 LEGEND: PVC LATERAL PIPE PVC MALE ADAPTER 6" MINIUMUM DEPTH OF WASHED 3/4" CRUSHED GRAVEL. 10" ROUND VALVE BOX AS SPECIFED MIN. 2 CONCRETE BLOCKS, ONE EACH SIDE IRRIGATION HOSE (LENGTH AS NECESSARY) MULCH 1" BALL VALVE 7 8 5 2 7 1 3 48 6