HomeMy WebLinkAbout16-L2.2 IRRIGATION DETAILSProject
Date
Drawn by
Checked byarchitectsNelson DreamDesignBuild621 2nd Avenue North Great Falls, MT 59401406.727.3286 NelsonArchitects.comNOT FOR CONST.REVISION SCHEDULE
#DESCRIPTION DATE
CONSTRUCTIONISSUED FOR6-21-24
23-012
GSG
NGSBOZEMAN ATWELL HOTEL1851 BAXTER LANE, BOZEMAN MONTANA59715P L L C
GOLF COURSE ARCHITECTURE
IRRIGATION DESIGN
LANDSCAPE ARCHITECTURE
THUESEN
STEINER
NATHAN
STEINER
143
G
CNLADS
APE ARCHITECTOMNTANA
R
EG
ISTERED
L2.2IRRIGATION DETAILSFINISH GRADE
CURB OR BED
PAVEMENT
EDGE OF
LATERAL PIPE
PVC CLASS 200
PVC TEE
AS SPECIFIED
SWING JOINT
AS SPECIFIED
SPRAY HEAD
NOZZLE
MATCHED PRECIPITATION
1 TURF SPRAY HEAD DRIP EMITTER AT PLANT
PVC LATERAL PIPE
STAKE, AS REQUIRED
2
BE FLUSH WITH TOP OF MULCH.
FPT BASE. BOTTOM OF EMITTER TO
GPH TRUCHECK DRIP, EMITTER WITH
MULCH, AS SPECIFIED
PVC SCH. 40 SST TEE/ELL
1/2" 90° ELL BARBED INSERT FITTING
14" LONG MINIMUM, 48" LONG MAXIMUM.
1/2" DISTRIBUTION TUBING (RAINBIRD SPX-FLEX)
TOPSOIL
FINISH GRADE
1/2" MARLEX STREET ELL
1/2" 90° ELL BARBED INSERT FITTING
NOTES:
3. PLACE EMITTER ON UPHILL SIDE OF PLANT ON SLOPES.
2. REFER TO DRIP SCHEDULE FOR NUMBER OF EMITTERS AND FLOW.
1. MINIMUM (2) EMITTERS PER PLANT UNLESS NOTED OTHERWISE.
NOT TO SCALE12"NOT TO SCALE
2-1/2" 3" MIN.NOTES:
TO BE USED.
1. DO NOT DRIVE REBAR THROUGH TABS ON SWING JOINT, STABILIZING BAR
5 TYPICAL QUICK COUPLER
NOT TO SCALE
BOX AS SPECIFIED
10" ROUND VALVE
VALVE AS SPECIFIED
QUICK COUPLING
TO FIT
NOTCH VALVE BOX
STABILIZING BAR -
1" X 18" SCH 80
45° MAX.
30° MIN.
AS SPECIFIED
UNITIZED SWING JOINT
FLOWLATERAL PIPE
MAINLINE/
ONE EACH SIDE
MIN. 2 CONC. BLOCKS,
WASHED AGGREGATE
6" MIN. OF 3/4"
COMPACTED SOIL
AS SPECIFIED
SCH 80 PVC TEE
FINISH GRADE
NOTES:
2. PROVIDE 1" MIN. SPACE BETWEEN BOTTOM OF VALVE BOX AND TOP OF MAINLINE.
BETWEEN LID AND TOP OF AIR RELEASE VALVE.
1. ROTATE TEE ON MAINLINE AS NECESSARY TO ENSURE CLEARANCE IS PROVIDED
6 AIR RELIEF VALVE
NOT TO SCALE
AS SPECIFIED
1" GATE VALVE
AIR RELEASE VALVE
BERMAD 1"- C10
AS SPECIFIED
SERVICE TEE
1" SCH 80 PVCPVC NIPPLE
1" CLOSE
FINISH GRADE
EACH CORNER
BLOCKS, ONE
MIN. 4 CONC.
RISER AS SPECIFIED
VALVE BOX &
BASE
3/4" AGGREGATE
6" OF WASHED
THRUST BLOCK
2SF CONCRETE
18"12"4
87
13 14
6
5
FLOW
16
3
1 2
11
12
17
9
15
10
9 TYPICAL ELECTRIC CONTROL VALVE
NOT TO SCALE
NOTES:
VALVE SIZE CALLED FOR ON PLANS.
1. ADJUST SIZE OF PVC FITTINGS TO MATCH ELECTRIC
LEGEND:
BOX.
17. 1" MIN. SPACE BETWEEN LATERAL AND VALVE
16. MIN. 4 CONC. BLOCKS, ONE EACH CORNER.
15. VALVE ID TAG, AS SPECIFIED.
ALL SPLICES IN VALVE BOX.
14. DBY WIRE CONNECTORS AS SPECIFIED, MAKE
13. PROVIDE 20 EXPANSION COILS EACH WIRE
12. FINISH GRADE
11. VALVE BOX AS SPECIFIED, RISER AS REQUIRED.
2" CLEARANCE BELOW VALVE.
10. 6" OF WASHED 3/4" AGGREGATE BASE, MAINTAIN
9. SOLVENT WELD PIPE TO LATERALS.
8. 3" X 2" SCH 80 1 PIECE REDUCER COUPLING
7. 2" X 4" SCH. 80 T.O.E. NIPPLE
6. 2" - T X T SCH. 80 UNION
5. 2" X 2" T.B.E. SCH 80 NIPPLE
4. ELECTRIC VALVE AS SPECIFIED
3. SCH 80 PVC T.O.E. NIPPLES AND ELBOW
2. SCH 80 PVC SERVICE TEE
1. MAINLINE
DIAMETERS
5 PIPE
FLOW
3/4" WASHED GRAVEL
VALVE INLET SIZE.
SCH 80 NIPPLES,
10 PIPE DIAMETERS
NO VALVES, REDUCERS, OR ELBOWS IN THIS AREA
FINISH GRADE
EXTENSIONS AS SPECIFIED.
VALVE BOX WITH 6"
LOOPED WIRES. TO AIRCARD WITH SLC SPLICE.
WATERPROOF WIRE CONNECTORS ON 18"
1" MIN. SPACE OVER MAINLINE
SCH 80 PVC REDUCER AS REQUIRED.
3/4" WASHED GRAVEL
80 UNION
SCHEDULE
SUBMAINLINE
VALVE INLET SIZE.
SCHEDULE 80 NIPPLE TOE,
CONCRETE SUPPORT BLOCKS, 4 PER BOX, MIN.
GOPHER SCEEN. WRAP UP SIDES, OVER
AT BOTTOM OF EACH BOX: 1/2" WIRE CLOTH
CONNECTORS
WATERPROOF WIRE
NORMALLY OPEN
MASTER VALVE,
FLOW SENSOR.
BACK TO CONTROLLER (SEE NOTE 1).
PE39/98 CABLE IN 1" SCH 40 PVC CONDUIT
NOT TO SCALE
8 MASTER VALVE AND FLOW SENSOR
NOTES:
4. FLOW SENSOR ANGLE TO BE PER MANUFACTURER'S RECOMMENDATIONS.
3. MINIMUM DISTANCES BETWEEN ANY FITTING OR VALVE AND FLOW SENSOR ARE NOTED ABOVE.
2. FLOW SENSOR PIPE RUN SIZE SAME AS FLOW SENSOR SIZE NOTED ON PLANS.
IN LAYING DISTANCE FROM FLOW SENSOR TO IRRIGATION CONTROLLER.
1. 1 PAIR, TWISTED SHIELDED CABLE-MINIMUM CONDUCTOR SIZE 20 AWG. DO NOT EXCEED 2,000 FEET NOTES:
2. THIS DETAIL FOR VALVES 2-1/2" AND SMALLER.
1. VALVE TO BE SUPPORTED BY GRAVEL, PROVIDE BLOCK SHIM AS REQUIRED.
FINISH GRADE
AS SPECIFIED
VALVE BOX
LINE SIZE GATE VALVE
LATERAL AND VALVE BOX
1" MIN. SPACE BETWEEN
MAINLINE PIPE
ONE EACH CORNER
MIN. 4 CONC. BLOCKS,
3/4" AGGREGATE BASE
6" OF WASHED
MANUAL ISOLATION VALVE7
NOT TO SCALE
TYPICAL DRIP CONTROL VALVE10
NOT TO SCALE12"18"12
11
19. 1" BALL VALVE
18. PRESSURE REGULATING DRIP FILTER, SEE NOTES.
17. 1" MIN. SPACE BETWEEN LATERAL AND VALVE BOX.
16. MIN. 4 CONC. BLOCKS, TWO EACH SIDE.
15. VALVE ID TAG, AS SPECIFIED.
14. DBY WIRE CONNECTORS AS SPECIFIED, MAKE ALL SPLICES IN VALVE BOX.
13. PROVIDE 20 EXPANSION COILS EACH WIRE.
12. FINISH GRADE.
11. JUMBO VALVE BOX AS SPECIFIED, RISER AS REQUIRED.
VALVE.
10. 6" OF WASHED 3/4" AGGREGATE BASE, MAINTAIN CLEARANCE BELOW
9. SOLVENT WELD PIPE TO LATERALS.
8. 2" X 1" SCH 80 1 PIECE REDUCER COUPLING.
7. 1" X 4" SCH. 80 T.O.E. NIPPLE.
6. 1" - T X T SCH. 80 UNION.
5. 1" X 1" T.B.E. SCH 80 NIPPLE.
4. ELECTRIC VALVE AS SPECIFIED.
3. 1" SCH 80 PVC ELBOW & NIPPLES, LENGTH AS REQUIRED.
2. SCH 80 PVC SERVICE TEE.
1. MAINLINE.
LEGEND:
NOTES:
2. PRESSURE REGULATING FILTER: SEE LEGEND.
FOR ON PLANS.
1. ADJUST SIZE OF FITTINGS TO MATCH ELECTRIC VALVE SIZE CALLED
1
2
5
3
6 10
17
9
8
7
17
18
4
15 13 14
19
13 CONTROLLER
18" BELOW FINISH GRADE.
1. ROUTE CONDUIT THROUGH FLOOR AND SWEEP THROUGH FOUNDATION AT
NOTES:
LEGEND:
1
PVC SCH 40 CONDUIT AND FITTINGS, SIZE AS SPECIFIED.2
WIRES TO REMOTE CONTROL VALVES, MASTER VALVE, AND FLOW SENSOR.3
MODULAR HYBRID CONTROLLER, AS SPECIFIED. INSIDE WALL MOUNT.
STANDARD MODULE FOR 4-STATION CONTROLLER.
EXPANSION MODULES.
STANDARD 120 V PLUG.
120 VAC, 60 HZ INTERNAL TRANSFORMER.
4
5
6
7
NOT TO SCALE
INSIDE CONTROLLER CHASSIS
INSIDE FRONT COVER
1
2
3
.MOUNTING WALL
1
6
4 5
37
12 TRENCHING DETAILS
AND LOCATED ON AS-BUILT PLANS.
SHALL BE MADE IN VALVE BOXES
WIRING AND MAINLINE. ALL SPLICES
6" ABOVE ALL DIRECT BURIAL 120 V.
INTERVALS. USE 6" WIDE MARKING TAPE
TAPE & BUNDLE ALL WIRING AT 10'
PULL BOXES AS REQUIRED.
SLEEVES SHALL BE IN CONDUIT. PROVIDE
WIRING UNDER PAVEMENT & THROUGH
WITH MARKER TAPE AS ABOVE. ALL
ALL 120 V. WIRING SHALL BE IN CONDUIT
AFTER MAKING CONNECTIONS.
GREATER THAN 30°. UNTIE ALL LOOPS
AT ALL CHANGES IN DIRECTION
TIE A LOOSE 20" LOOP IN WIRING
SECTION
CONDUIT
PLAN
CONDUIT
VOLTAGE ONLY
SECTION-LOW
DIRECT BURY
PLAN
DIRECT BURY
PLANS
FINISH GRADE
LOOP
O.C. MAX.
TIES 10'
LATERAL
SECTIONS
FINISH GRADE
LATERAL
MAINLINE
BEDDING.
MARKING TAPE
120 V. WIRE IN CONDUIT
TRENCH
PIPE IN
LATERAL
SNAKE ALL
FINISH GRADE
12"
18"12"18"12"
12"
MIN.
30"
WIRE
VOLTAGE
LOW
NOT TO SCALE
THE 120 V. WIRE AT MAINLINE PIPE DEPTH.
2. LOW VOLTAGE WIRE TO BE BUNDLED AND INSTALLED OPPOSITE
AS SHOWN ON THE PLANS.
1. 120 V. WIRE TO BE INSTALLED ON THE SIDE OF THE MAINLINE
NOTES:
FINISH GRADE
MARKING TAPE
CONTINUOUS
MARKING TAPE
11 TYP. MAINLINE DRAIN
NOTES:
FINISH GRADE
BOX AS SPECIFIED
10" ROUND VALVE
AGGREGATE
¾" WASHED
LENGTH AS REQUIRED
4" PVC RISER
COMPACTED SOIL
ONE EACH SIDE
MIN. 2 CONC. BLOCKS ,
TURN DOWN AT ENDS
SUPAC 4NP CLOTH,
DRAIN TO DAYLIGHT
1-1/2" CL 200 PVC
SCH 80 PVC ELBOW
1-1/2" GATE VALVE
SCHED. 80 MALE ADAPTOR
AGGREGATE
1 CY OF 1-1/2" WASHED
DRY WELL WITH MIN.
NOT TO SCALE
TEE ON BOTTOM
SCH 80 PVC SERVICE
MAINLINE WITH 1-1/2"
TO STEEL PIPE 36" BEFORE END OF PIPE.
1. DRAIN TO DAYLIGHT WHEREVER POSSIBLE. TRANSITION
SCH 80 PVC T.O.E. NIPPLE
T.O.E. NIPPLE
SCH 80 PVCMIN.3" WIRE
LOW VOLTAGE
2"
MIN.12" MINIMUM1/4" MIN.4 ROOT WATERING SYSTEM
NOT TO SCALE
4. FOLLOWING INSTALLATION, FILL BASKET WITH PEA GRAVEL.
3. INSTALL 4"-6" OF 3/4" WASHED ROCK AROUND UNIT.
2. TOP OF GRATE TO MATCH TOP OF MULCH.
1. SPACE UNITS EVENLY AROUND ROOTBALL.
NOTES:
4" WIDE X 18" LONG RIGID
LATERAL PIPE.
PVC SCH 40 TEE OR ELBOW.
MALE NPT INLET.
FUNNY PIPE SWING ASSEMBLY
LOCKING GRATE.
TOP OF MULCH.
BUBBLER.
ROOT WATERING SYTEM.
LEGEND:
1
2
33
4
55
6
77
8
9 BASKET WEAVE CANISTER.
1
2
4
3
5
6
78
918"TREE ROOT BALL10
10
POSSIBLE
60-90° IF
INSTALL AT
.
SAME SIZE AS MASTER VALVE
12" LONG SCH 80 PVC NIPPLE,
MALE ADAPTER
MAINLINE W/ PVC
MASTER VALVE
SAME SIZE AS
GATE VALVE COVER18" MINIMUM DRIP LATERAL FLUSH VALVE3
NOT TO SCALE
1
2
3
4
5
6
LEGEND:
PVC LATERAL PIPE
PVC MALE ADAPTER
6" MINIUMUM DEPTH OF WASHED 3/4" CRUSHED GRAVEL.
10" ROUND VALVE BOX AS SPECIFED
MIN. 2 CONCRETE BLOCKS, ONE EACH SIDE
IRRIGATION HOSE (LENGTH AS NECESSARY)
MULCH
1" BALL VALVE
7
8
5 2
7 1
3
48
6