Loading...
HomeMy WebLinkAbout14-L1.2 PLANTING DETAILS0+00 0+10 0+20 0+30 0+40 0+50 0+60 4710 4720 4730 4710 4720 4730 GRASS NATIVE WETLAND GRASS RETENTION POND GRASS NATIVE FENCE EXISTING Project Date Drawn by Checked byarchitectsNelson DreamDesignBuild621 2nd Avenue North Great Falls, MT 59401406.727.3286 NelsonArchitects.comNOT FOR CONST.REVISION SCHEDULE #DESCRIPTION DATE CONSTRUCTIONISSUED FOR6-21-24 23-012 GSG NGSBOZEMAN ATWELL HOTEL1851 BAXTER LANE, BOZEMAN MONTANA59715P L L C GOLF COURSE ARCHITECTURE IRRIGATION DESIGN LANDSCAPE ARCHITECTURE THUESEN STEINER NATHAN STEINER 143 G CNLADS APE ARCHITECTOMNTANA R EG ISTERED 1 PLAN CHANGE 2-21-25 2 CITY COMMENTS 2-21-25 SD 3'4'4'4'4'4'4'4'3'2'-6"L1.2PLANTING DETAILSNOT TO SCALE WARRANTY PERIOD. COMPLETION OF THE ANY TIME THROUGH IF DIRECTED TO DO SO AT TREE WITHOUT QUESTION REPLACE ANY UNSTAKED THE CONTRACTOR SHALL MANDATORY, HOWEVER, 1. STAKING IS NOT FROM BALL AS NEEDED. ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY. ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF PRUNE AS SPECIFIED TO RETAIN NATURAL FORM. FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE.3/4- 2/31/4- 1/3UNBURIEDBURIEDGRADE FINISH MULCH AT END OF WARRANTY PERIOD. TREE TO SWAY. CONTRACTOR TO REMOVE TRUNK WRAP, STAKES & TIES SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT 6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON MULCH TO EXTEND BEYOND STAKES AND 6" BEYOND DRIPLINE (5' DIA.) 3" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM TRUNK. WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS. SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER. ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING. 1 22 3 4 5 6 7 1 2 3 4 5 6 7 LEGEND: NOTES: 1 2 GRAFT UNION TYP. 4-6" ABOVE ROOT FLARE. FROM BALL AS NEEDED. ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL 3 4 ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY. ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF 5 6 1 25 7 8 SECURE WITH ELECTRICAL TAPE. DO NOT WRAP TIGHTLY. ASPHALT COATED PAPER TREE WRAP TO BOTTOM OF FIRST BRANCH, 9 FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE. WARRANTY PERIOD. COMPLETION OF THE ANY TIME THROUGH IF DIRECTED TO DO SO AT TREE WITHOUT QUESTION REPLACE ANY UNSTAKED THE CONTRACTOR SHALL MANDATORY, HOWEVER, 1. STAKING IS NOT 6 4 9 8 PRUNE AS SPECIFIED TO RETAIN NATURAL FORM. WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS. SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER. ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING. MULCH TO EXTEND BEYOND STAKES AND 6" BEYOND DRIPLINE (5' DIA.) 3" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM TRUNK. AT END OF WARRANTY PERIOD. TREE TO SWAY. CONTRACTOR TO REMOVE TRUNK WRAP, STAKES & TIES SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT 6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON NOTES: LEGEND: LINEAR SPACING AT JOINTS. SPACING 3' O.C. & 1' O.C. WEED BARRIER, TRIANGULAR 8"STAPLES TO ANCHOR SPECIFIED. LAP 3" AT JOINTS. WEED BARRIER FABRIC AS SPECIFICATIONS MANUFACTURER'S & INSTALL ACCORDING TO EDGING AS SPECIFIED, STAKE GRADE FINISH SPECIFIED MULCH AS1" FLARE VISIBLENOT TO SCALE 1 CONIFEROUS TREE PLANTING 2 DECIDUOUS TREE PLANTING 1" FLARE VISIBLENOT TO SCALE 5 LANDSCAPE BOULDER PLACEMENT NOT TO SCALE 6 EDGING, MULCH & FABRIC 3"½"33 7 ROOT BARRIER NOTES: 2. EXCAVATION AND SOIL PREPARATION SHALL CONFORM TO THE DRAWINGS ABOVE FINISH GRADE PRIOR TO INSTALLATION OF MULCH. INWARDS TO THE ROOT BALL AND THE DOUBLE TOP EDGE SHALL BE 1/2" (12.7MM) SHOWN ON THE DRAWINGS. THE VERTICAL ROOT DEFLECTING RIBS SHALL BE FACING 1. THE CONTRACTOR SHALL INSTALL THE TREE ROOT BARRIERS IN THE LOCATION POLYETHYLENE PANEL HOMOPOLYMER 0.080" (2.03MM) THICK INSTALLED VERTICALLY INTEGRAL TO PANEL, 48"24" BIKE RACK8 3. SEE L1.1 FOR LOCATIONS. 2. INSTALL ACCORDING TOP MANUFACTURER'S RECOMMENDATIONS. 1. BIKE RACK SHALL BE AS SPECIFIED. NOTES: 21-7/8"21-5/8"36"COMPACTED SUBGRADE ELEVATION NOT TO SCALE BASE MATERIAL COMPACTED GRAVEL SITE CONCRETE CONTRACTOR CONCRETE FLATWORK BY SURFACE MOUNT ADHESIVE ANCHOR BOLTS 3/8" X 3-1/2" CONCRETE NOT TO SCALE PLAN 5'-10¾"1'-2½"18" MIN.19" MAX.17" MIN.20" MIN. 24" MAX. 4. SHIMS NOT ALLOWED FOR LEVELING, SEE SPECIFICATIONS. 3. INSTALLATION TO BE PER MANUFACTURER'S RECOMMENDATIONS. 2. BENCH TO BE ASSEMBLED PRIOR TO ANCHORING. 1. BENCH WITH BACK AS SPECIFIED. 6'-0 ½"2'-1⅜"PLAN ELEVATION NOTES: BENCH FRAME (RIGHT) (LEFT) BENCH FRAME BENCH SEAT FOR ANCHORS (TYPICAL-4) 5/8" DIA. HOLE PROVIDED SIZE AS REQUIRED. ANCHOR BOLTS, SEE CIVIL CONCRETE PAD, NOT TO SCALE 9 BENCH A 1 SECTION A 1 NOT TO SCALE 10 SECTION - RETENTION POND FINISH GRADE PLANT FORM. TO RETAIN NATURAL PRUNE AS SPECIFIED 4 SHRUB PLANTING FINISH GRADE ONE YEAR. SAUCER. REMOVE AFTER AREAS SHALL HAVE EARTH ONLY PLANTS IN NATIVE 1" MIN.BED EDGING BEFORE PLANTING. EXCESS CONTAINER GROWTH MEDIUM AWAY FROM STEM RADIALLY. REMOVE ROOTS. ARRANGE ROOTS TO POINT ROOT BALL. PRUNE OFF GIRDLING REMOVE CONTAINER AND INSPECT BARRIER AS SPECIFIED. 3" MULCH OVER WEED AIR POCKETS. INSTALLATION TO ELIMINATE THOROUGHLY AFTER WATER. WATER IN IN LAYERS, SETTLE WITH SPECIFIED AMENDMENTS EXISTING SOIL AND ANY BACKFILL HOLE WITH ON UNDISTURBED SOIL. GLAZING. ROOT BALL RESTS ROUGHEN SIDES TO BREAK PLANTED POT TO POT. OF BALL. EXCEPT HEDGES DIG HOLE MIN. 2X WIDTH NOT TO SCALE AWAY FROM PLANT. KEEP MULCH 2"-3" 3 ORNAMENTAL GRASS PLANTING NOT TO SCALE BEFORE PLANTING. EXCESS CONTAINER GROWTH MEDIUM AWAY FROM STEM RADIALLY. REMOVE ROOTS. ARRANGE ROOTS TO POINT ROOT BALL. PRUNE OFF GIRDLING REMOVE CONTAINER AND INSPECT 1" MIN.FINISH GRADE BED EDGING FINISH GRADE BARRIER AS SPECIFIED. 3" MULCH OVER WEED SAUCER. AREAS SHALL HAVE EARTH ONLY PLANTS IN NATIVE AIR POCKETS. INSTALLATION TO ELIMINATE THOROUGHLY AFTER WATER. WATER IN IN LAYERS, SETTLE WITH SPECIFIED AMENDMENTS EXISTING SOIL AND ANY SOIL. BACKFILL HOLE WITH BALL RESTS ON UNDISTURBED TO BREAK GLAZING. ROOT OF BALL. ROUGHEN SIDES DIG HOLE MIN. 2X WIDTH AWAY FROM PLANT. KEEP MULCH 2"-3" 11 TABLE NOT TO SCALE 3. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. PERMANENTLY AFFIXED TO THE GROUND. 1. LOCATE ANCHOR BOLTS AFTER TABLE AND SEATS ARE IN PLACE. TABLE SHALL BE HEIGHT TABLE HEIGHT SEAT NOTES: * ALL DIMENSIONS ARE IN INCHES * 76-5/8"48"46"18"12"30-5/16"BOLT ADHESIVE ANCHOR 3/8" X 3" CONCRETE 2