HomeMy WebLinkAbout14-L1.2 PLANTING DETAILS0+00 0+10 0+20 0+30 0+40 0+50 0+60
4710
4720
4730
4710
4720
4730
GRASS
NATIVE
WETLAND GRASS
RETENTION POND
GRASS
NATIVE
FENCE
EXISTING
Project
Date
Drawn by
Checked byarchitectsNelson DreamDesignBuild621 2nd Avenue North Great Falls, MT 59401406.727.3286 NelsonArchitects.comNOT FOR CONST.REVISION SCHEDULE
#DESCRIPTION DATE
CONSTRUCTIONISSUED FOR6-21-24
23-012
GSG
NGSBOZEMAN ATWELL HOTEL1851 BAXTER LANE, BOZEMAN MONTANA59715P L L C
GOLF COURSE ARCHITECTURE
IRRIGATION DESIGN
LANDSCAPE ARCHITECTURE
THUESEN
STEINER
NATHAN
STEINER
143
G
CNLADS
APE ARCHITECTOMNTANA
R
EG
ISTERED
1 PLAN CHANGE 2-21-25
2 CITY COMMENTS 2-21-25
SD
3'4'4'4'4'4'4'4'3'2'-6"L1.2PLANTING DETAILSNOT TO SCALE
WARRANTY PERIOD.
COMPLETION OF THE
ANY TIME THROUGH
IF DIRECTED TO DO SO AT
TREE WITHOUT QUESTION
REPLACE ANY UNSTAKED
THE CONTRACTOR SHALL
MANDATORY, HOWEVER,
1. STAKING IS NOT
FROM BALL AS NEEDED.
ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL
ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY.
ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL
REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF
PRUNE AS SPECIFIED TO RETAIN NATURAL FORM.
FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE.3/4- 2/31/4- 1/3UNBURIEDBURIEDGRADE
FINISH
MULCH
AT END OF WARRANTY PERIOD.
TREE TO SWAY. CONTRACTOR TO REMOVE TRUNK WRAP, STAKES & TIES
SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING
PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES
STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT
6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON
MULCH TO EXTEND BEYOND STAKES AND 6" BEYOND DRIPLINE (5' DIA.)
3" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM TRUNK.
WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS.
SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER.
ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING
DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING.
1
22
3
4
5
6
7
1
2
3
4
5
6
7
LEGEND:
NOTES:
1
2
GRAFT UNION TYP. 4-6" ABOVE ROOT FLARE.
FROM BALL AS NEEDED.
ROOT FLARE VISIBLE ABOVE FINISH GRADE. REMOVE EXCESS SOIL
3
4
ROOT FLARE. ARRANGE ROOTS TO LEAVE TRUNK & ROOT FLARE RADIALLY.
ANY GIRDLING ROOTS, PRESS ALL HAIR ROOTS DOWN UNDER STRUCTURAL
REMOVE WIRE BASKET & ALL BURLAP. INSPECT ROOT BALL & PRUNE OFF
5
6
1
25
7
8
SECURE WITH ELECTRICAL TAPE. DO NOT WRAP TIGHTLY.
ASPHALT COATED PAPER TREE WRAP TO BOTTOM OF FIRST BRANCH,
9 FINISH GRADE - SLOPE AWAY FROM TREES WHEREVER POSSIBLE.
WARRANTY PERIOD.
COMPLETION OF THE
ANY TIME THROUGH
IF DIRECTED TO DO SO AT
TREE WITHOUT QUESTION
REPLACE ANY UNSTAKED
THE CONTRACTOR SHALL
MANDATORY, HOWEVER,
1. STAKING IS NOT
6
4
9
8
PRUNE AS SPECIFIED TO RETAIN NATURAL FORM.
WATER IN THOROUGHLY AFTER INSTALLATION TO ELIMINATE AIR POCKETS.
SOIL AND ANY SPECIFIED AMENDMENTS IN LAYERS, SETTLE WITH WATER.
ROOT BALL TO REST ON UNDISTURBED SOIL. BACKFILL HOLE WITH EXISTING
DIG HOLE MIN. 2X WIDTH OF BALL. ROUGHEN SIDES TO BREAK GLAZING.
MULCH TO EXTEND BEYOND STAKES AND 6" BEYOND DRIPLINE (5' DIA.)
3" MULCH AS SPECIFED. NO WEED BARRIER. END MULCH 3" FROM TRUNK.
AT END OF WARRANTY PERIOD.
TREE TO SWAY. CONTRACTOR TO REMOVE TRUNK WRAP, STAKES & TIES
SHOULD BE SNUG ENOUGH TO PROVIDE SUPPORT WHILE ALLOWING
PENETRATE ROOT BALL. DO NOT OVER-TIGHTEN AROUND TREE. TIES
STRAP WITH BRASS GROMET TIES ON TRUNK. STAKES SHALL NOT
6' STEEL TEE POSTS, 2/TREE W/ 14 GA. SOFT WIRE AND 1-1/2"X18" NYLON
NOTES:
LEGEND:
LINEAR SPACING AT JOINTS.
SPACING 3' O.C. & 1' O.C.
WEED BARRIER, TRIANGULAR
8"STAPLES TO ANCHOR
SPECIFIED. LAP 3" AT JOINTS.
WEED BARRIER FABRIC AS
SPECIFICATIONS
MANUFACTURER'S
& INSTALL ACCORDING TO
EDGING AS SPECIFIED, STAKE
GRADE
FINISH
SPECIFIED
MULCH AS1" FLARE VISIBLENOT TO SCALE
1 CONIFEROUS TREE PLANTING 2 DECIDUOUS TREE PLANTING 1" FLARE VISIBLENOT TO SCALE
5 LANDSCAPE BOULDER PLACEMENT
NOT TO SCALE
6 EDGING, MULCH & FABRIC 3"½"33
7 ROOT BARRIER
NOTES:
2. EXCAVATION AND SOIL PREPARATION SHALL CONFORM TO THE DRAWINGS
ABOVE FINISH GRADE PRIOR TO INSTALLATION OF MULCH.
INWARDS TO THE ROOT BALL AND THE DOUBLE TOP EDGE SHALL BE 1/2" (12.7MM)
SHOWN ON THE DRAWINGS. THE VERTICAL ROOT DEFLECTING RIBS SHALL BE FACING
1. THE CONTRACTOR SHALL INSTALL THE TREE ROOT BARRIERS IN THE LOCATION
POLYETHYLENE PANEL
HOMOPOLYMER
0.080" (2.03MM) THICK
INSTALLED VERTICALLY
INTEGRAL TO PANEL, 48"24"
BIKE RACK8
3. SEE L1.1 FOR LOCATIONS.
2. INSTALL ACCORDING TOP MANUFACTURER'S RECOMMENDATIONS.
1. BIKE RACK SHALL BE AS SPECIFIED.
NOTES:
21-7/8"21-5/8"36"COMPACTED SUBGRADE
ELEVATION
NOT TO SCALE
BASE MATERIAL
COMPACTED GRAVEL
SITE CONCRETE CONTRACTOR
CONCRETE FLATWORK BY
SURFACE MOUNT
ADHESIVE ANCHOR BOLTS
3/8" X 3-1/2" CONCRETE
NOT TO SCALE
PLAN
5'-10¾"1'-2½"18" MIN.19" MAX.17" MIN.20" MIN.
24" MAX.
4. SHIMS NOT ALLOWED FOR LEVELING, SEE SPECIFICATIONS.
3. INSTALLATION TO BE PER MANUFACTURER'S RECOMMENDATIONS.
2. BENCH TO BE ASSEMBLED PRIOR TO ANCHORING.
1. BENCH WITH BACK AS SPECIFIED.
6'-0 ½"2'-1⅜"PLAN
ELEVATION
NOTES:
BENCH FRAME (RIGHT)
(LEFT)
BENCH FRAME
BENCH SEAT
FOR ANCHORS (TYPICAL-4)
5/8" DIA. HOLE PROVIDED
SIZE AS REQUIRED.
ANCHOR BOLTS,
SEE CIVIL
CONCRETE PAD,
NOT TO SCALE
9 BENCH
A
1 SECTION
A
1
NOT TO SCALE
10 SECTION - RETENTION POND
FINISH GRADE
PLANT FORM.
TO RETAIN NATURAL
PRUNE AS SPECIFIED
4 SHRUB PLANTING
FINISH GRADE
ONE YEAR.
SAUCER. REMOVE AFTER
AREAS SHALL HAVE EARTH
ONLY PLANTS IN NATIVE 1" MIN.BED EDGING
BEFORE PLANTING.
EXCESS CONTAINER GROWTH MEDIUM
AWAY FROM STEM RADIALLY. REMOVE
ROOTS. ARRANGE ROOTS TO POINT
ROOT BALL. PRUNE OFF GIRDLING
REMOVE CONTAINER AND INSPECT
BARRIER AS SPECIFIED.
3" MULCH OVER WEED
AIR POCKETS.
INSTALLATION TO ELIMINATE
THOROUGHLY AFTER
WATER. WATER IN
IN LAYERS, SETTLE WITH
SPECIFIED AMENDMENTS
EXISTING SOIL AND ANY
BACKFILL HOLE WITH
ON UNDISTURBED SOIL.
GLAZING. ROOT BALL RESTS
ROUGHEN SIDES TO BREAK
PLANTED POT TO POT.
OF BALL. EXCEPT HEDGES
DIG HOLE MIN. 2X WIDTH
NOT TO SCALE
AWAY FROM PLANT.
KEEP MULCH 2"-3"
3 ORNAMENTAL GRASS PLANTING
NOT TO SCALE
BEFORE PLANTING.
EXCESS CONTAINER GROWTH MEDIUM
AWAY FROM STEM RADIALLY. REMOVE
ROOTS. ARRANGE ROOTS TO POINT
ROOT BALL. PRUNE OFF GIRDLING
REMOVE CONTAINER AND INSPECT 1" MIN.FINISH GRADE
BED EDGING
FINISH GRADE
BARRIER AS SPECIFIED.
3" MULCH OVER WEED
SAUCER.
AREAS SHALL HAVE EARTH
ONLY PLANTS IN NATIVE
AIR POCKETS.
INSTALLATION TO ELIMINATE
THOROUGHLY AFTER
WATER. WATER IN
IN LAYERS, SETTLE WITH
SPECIFIED AMENDMENTS
EXISTING SOIL AND ANY
SOIL. BACKFILL HOLE WITH
BALL RESTS ON UNDISTURBED
TO BREAK GLAZING. ROOT
OF BALL. ROUGHEN SIDES
DIG HOLE MIN. 2X WIDTH
AWAY FROM PLANT.
KEEP MULCH 2"-3"
11 TABLE
NOT TO SCALE
3. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
PERMANENTLY AFFIXED TO THE GROUND.
1. LOCATE ANCHOR BOLTS AFTER TABLE AND SEATS ARE IN PLACE. TABLE SHALL BE
HEIGHT
TABLE
HEIGHT
SEAT
NOTES:
* ALL DIMENSIONS ARE IN INCHES *
76-5/8"48"46"18"12"30-5/16"BOLT
ADHESIVE ANCHOR
3/8" X 3" CONCRETE
2