Loading...
HomeMy WebLinkAboutType TB1_specsheet_bollardLSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (800) 436-7800 • ©LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 1/3 Rev. 08/02/22 SPEC.1111.A.1121 Catalog #:Project: Date:Type:Prepared By: Mirada Bollard (MRB) Low Level Lighting FEATURES & SPECIFICATIONS Construction • Precision 2pc die-cast aluminum head maintains durability and consistency while providing vandal resistance, effective heat dissipation, and superior aesthetics. • 8-5/8” OD one-piece extruded aluminum heavy wall .322 inch thick seamless shaft. Various heights are available in 6” increments starting at a minimum of 26” (maximum height is 62”). • Lower housing attaches to cast aluminum universal base plate with four stainless steel roll pins. Accommodates 4.5” - 6” bolt circles. • Optional roughneck zinc plated steel base plate (.375” thick) with welded U shaped reinforcement. 3/8” diameter 302 stainless steel roll pins with 10,000 lb. shear load. • IP66 rated Optical and Driver compartment protects integral components from harsh environments. • Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. Other standard LSI finishes available. Consult factory. • Luminaire is proudly manufactured in the U.S. of U.S. and imported parts. • Shipping weight: 40 lbs in carton. Optical System • Available in two optical distributions, symmetrical and asymmetrical. • High transmission clear flat acrylic lens seals the luminaire’s optical chamber to IP66. • Available in 5000K, 4000K, 3000K, and 2700K color temperatures per ANSI C78.377. Also available in Phosphor Converted Amber. Consult Factory for other color temperature requirements. • Minimum CRI of 70. Electrical • High-performance programmable driver features over-voltage, under-voltage, short- circuit and over temperature protection. Custom lumen and wattage packages available. • 0-10V dimming (10% - 100%) standard. • Standard Universal Voltage (120-277 Vac) Input 50/60 Hz. Optional High Voltage 347- 480 Vac Input available. • L91 Calculated Life: >100k Hours calculated @ 25°C per IESNA TM-21-11. • Total harmonic distortion: <20%. • Operating temperature: -40°C to +50°C (-40°F to +122°F); Cold-weather emergency battery backup rated for -20°C minimum ambient. • Power factor: >.90. • Input power stays constant over life. • High-efficacy LEDs with integrated circuit board mount to the housing to maximize heat dissipation and promote long life. • Driver components are fully encased in potting long material for moisture resistance. Driver complies with FCC standards. Driver and key electronic components can easily be accessed. • Electrical components are mounted on a removable power tray. • Field replaceable surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). • Optional 120v-277v integral emergency battery pack is available. The 90- minute batteries provide constant power to the LED system, ensuring code compliance. A test switch/indicator button is installed on the housing for ease of maintenance. Installation • Easy leveling even in uneven areas and full 360-degree rotation for precise alignment during installation. • Base plate installs with four heavy-duty 3/8” x 10” galvanized steel anchor bolts. • Base plate attaches to lower extruded housing via four stainless steel roll pins. Warranty • LSI luminaires carry a 5-year limited warranty. Refer to https://www.lsiindustries. com/resources/terms-and-warranty.aspx for more information. Listings • Listings • Listed to UL 1598 and UL 8750. • RoHS Compliant. • Meets Buy American Act requirements. • Suitable for wet locations. • IP66 rated Driver compartment and IP66 rated optical chamber per IEC 60598. • IDA compliant; with 3000K or 2700K color temperature selection. OVERVIEW Lumen Package 1,000 - 3,000 Wattage Range 23 - 38 Efficacy Range (LPW)72 - 84 Weight lbs (kg)40 (18) QUICK LINKS Ordering Guide Performance Photometrics Dimensions IP66 LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (800) 436-7800 • ©LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 2/3 Rev. 08/02/22 SPEC.1111.A.1121 Type: Mirada Bollard MRB ORDERING GUIDE Back to Quick Links Accessory Ordering Information Description Part Number HSS - House Side Shield 699105 Galvanized anchor Bolt kit 285560 TYPICAL ORDER EXAMPLE:MRB LED 25L ACR S UNV DIM 40 PCI120 BLK Prefix Technology LumenPackage Lens Distribution Voltage Driver Color Temp CRI Controls Battery Backup Finish Options MRB - Mirada Bollard LED 25L - 2,500 lm30L - 3,000 lm Custom LumenPackages 5 ACR - Acrylic A - Asymmetric S - Symmetric UNV - Universal Voltage (120-277V) HV- High Voltage (347-480V) DIM - 0-10V Dimming (10-100%) 50 - 5,000K 40 - 4,000K 30 - 3,000K 27 - 2,700K 1 AMB - Phosphor Converted Amber1 (Blank) - 70CRI Button Type Photocells PCI120 - 120V PCI208-277 - 208-277V PCI347 - 347V BB - Battery Backup CWBB - Cold Weather Battery Backup BLK - BlackBRZ - BronzeGMG - Gun Metal GrayGPT - Graphite MSV - Metallic SilverPLP - Platinum PlusSVG - Satin Verde GreenWHT - White H - XX (Specify Height) 2 GFR - GFI Duplex ReceptacleLAB - Less Anchor Bolts RN - Roughneck Heavy Duty Mtg Plate PERFORMANCE Back to Quick Links FOOTNOTES: 1 - Consult Factory for availability. 2 - Standard height is 44”. Non Standard heights are available in 6” increments. Minimum height is 26”, 32” with battery backup option. Maximum height is 62”.3 - Accessories are shipped seperately and field installed.4 - Not available in HV Voltage. 5 - Custom lumen and wattage packages available consult factory. Values are within industry standard tolerances but not DLC listed. DELIVERED LUMENS* Lumen Package Distribution CRI AMB CCT 2700K CCT 3000K CCT 4000K CCT 5000K CCT WattageDelivered Lumens Efficacy Delivered Lumens Efficacy Delivered Lumens Efficacy Delivered Lumens Efficacy Delivered Lumens Efficacy 25L S 70 1713 56 2242 74 2156 71 2487 82 2485 81 30.5 30L 2110 55 2761 72 2655 69 3063 80 3061 80 38.4 25L A 1327 58 1736 76 1670 73 1926 84 1925 84 23.0 30L 1634 56 2138 74 2056 71 2372 82 2370 81 29.1 *LED Chips are frequently updated therefore values are nominal. ELECTRICAL DATA (Amps)* Lumen Package Distribution 120V 208V 240V 277V 347V 480V 25L S 0.25 0.15 0.13 0.11 0.09 0.06 30L S 0.32 0.18 0.16 0.14 0.11 0.08 25L A 0.19 0.11 0.10 0.08 0.07 0.05 30L A 0.24 0.14 0.12 0.10 0.08 0.06 Recommended Lumen Maintenance1 AMBIENT TEMP C INITIAL2 25K HR2 50K HR2 75K HR3 100K HR3 0 C 100%98%95%93%90% 10 C 100%98%95%93%90% 20 C 100%98%95%93%91% 25 C 100%98%96%93%91% 30 C 99%96%93%91%88% 40 C 99%95%91%88%85% 50 C 99%94%89%84%80% *Electrical data at 25C (77F). Actual wattage may differ by +/-10%. 1- Lumen maintenance values at 25C are calculated per TM-21 based on LM-80 data and in-situ testing. 2- In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times the IESNA LM-80-08 total test duration for the device under testing. 3- In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times the IESNA LM-80-08 total test duration for the device under testing LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (800) 436-7800 • ©LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 3/3 Rev. 08/02/22 SPEC.1111.A.1121 Type: Mirada Bollard MRB PRODUCT DIMENSIONS Back to Quick Links ø 9.0(228.6 mm) 3/8" X 10" 1.5" (38mm) Bolt Circle 6" Maximum(114mm) Maximum Bolt Circle is 6" ConduitOpening3" (76mm)Bolt Projection Anchor Bolt Standard (Minimum) Bolt Circle is 4.5" UNIVERSAL MOUNTING BASE DETAILNote: Base plate dimensions may change without noticeDo not use for setting anchor bolts. Consult factory for baseplate templates. ø 9.0(228.6 mm) 44"(1117.6 mm) Symmetric Asymmetric PHOTOMETRICS Luminaire photometry has been conducted by an accredited laboratory in accordance with IESNA LM-79. As specified by IESNA LM-79 the entire luminaire is tested as the source resulting in a luminaire efficiency of 100%.