Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
001 - SUP001 - COVER SHEET
1. AIA DOCUMENT A201, GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION APPLIES TO THIS PROJECT AND SHALL BE INCORPORATED IN THE SERVICES PROVIDED BY THE GENERAL CONTRACTOR.2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT.3. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.4. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTING/ BRACING/ SHORING/ TEMPORARY SUPPORTS/ ETC. ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY AN ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE COMPLETION OF WALLS, CEILING, AND FINISH MATERIALS.5. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBING.6. ALL MATERIALS AND FINISHES ARE TO BE AS SPECIFIED BY OWNER, OR APPROVED EQUAL.7. SUBSTITUTIONS SHALL BE BY APPROVAL PRIOR TO THE BID, OR INDICATED AS A LINE ITEM ON THE BID AS AN ALTERNATE TO THE BASE BID. SEE SPECIFICATIONS IF AND WHEN APPLICABLE.8. CONTRACTOR IS TO USE WATER-RESISTANT GYPSUM WALL BOARD IN ALL WET SPACES (RESTROOMS, JANITORIAL AREAS, MECHANICAL/PLUMBING ROOMS, FOOD SERVICE ROOMS, ETC.)9. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS, SHOWING ANY CHANGES TO PLANS, ELEVATIONS, SYSTEMS, DIMENSIONS, ETC.GENERAL PROJECT NOTESLIST OF ABBREVIATIONS∠ANGLE@ ATAB ANCHOR BOLTACT ACOUSTIC CEILING TILEALT ALTERNATEAP ACCESS PANELAPPD APPROVEDAPPR APPROXIMATEARCH ARCHITECTURALASPH ASPHALTAVE AVERAGEBD BOARDBLDG BUILDINGBLKG BLOCKINGBM BEAMBM BENCH MARKBOT BOTTOMBRG BEARINGBRK BRICKDN DOWNDP DAMP ROOFINGDS DOWN SPOUTDW DISHWASHERE EASTEA EACHEL ELEVATIONELEC ELECTRICEQ EQUAL EQUIP EQUIPMENTEXIST EXISTINGEXT EXTERIORFD FLOOR DRAINFE FIRE EXTINGUISHERFF FINISHED FLOORFIN FINISHFIX FIXTUREFL FLOORFND FOUNDATIONLT LIGHTMATL MATERIALMAX MAXIMUMMECH MECHANICALMFR MANUFACTURERMIN MINIMUMMISC MISCELLANEOUSMOD MODULARMTL METALN NORTHNO NUMBERNOM NOMINALNTS NOT TO SCALEOC ON CENTEROF OWNER FURNISHEDOI OWNER INSTALLEDOPNG OPENINGOPP OPPOSITEOVHD OVERHEADRM ROOMS SOUTHSCHED SCHEDULESECT SECTIONSERV SERVICESHT SHEETSHTHG SHEATHINGSIM SIMILARSPEC SPECIFICATIONSQ SQUARESTD STANDARDSTG STORAGESTL STEELSTRUCT STRUCTURALSYS SYSTEMT&G TONGUE AND GROOVETHRU THROUGHTR TREADTYP TYPICALBS BOTH SIDECAB CABINETCC CENTER TO CENTERCER CERAMICCF CONTRACTOR FURNISHEDCI CONTRACTOR INSTALLEDCIR CIRCLECL CENTER LINECLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONST CONSTRUCTIONCONT CONTINUECT CERAMIC TILED DRYERDIA DIAMETERDIM DIMENSIONFT FEET / FOOTFTG FOOTINGGA GAUGEGALV GALVANIZEDGL GRADELINEGWB GYPSUM WALL BOARDHB HOSE BIBHDWD HARDWOODHOR HORIZONTALHT HEIGHTIN INCHINSUL INSULATIONINT INTERIORJST JOISTJT JOINTLAM LAMINATELAV LAVATORYLBS POUNDSLG LENGTHPERM PERMANENTPERP PERPENDICULARPL PLATEPLMB PLUMBINGPNL PANELPREFAB PREFABRICATEDPSI POUNDS PER SQUARE INCHPT POINTPTD PAINTEDPTN PARTITIONQTY QUANTITYRAD RADIUSR RISERREF REFRIGERATORREG REGISTERREINF REINFORCEREQD REQUIREDREV REVISIONRFG ROOFINGUNO UNLESS NOTED OTHERWISEVERT VERTICALVEST VESTIBULEVIF VERIFY IN FIELDVP VENT PIPEW WESTW WIDTHWD WOODWDW WINDOWWG WIRE GLASSWH WEEPHOLEW/M WASHING MACHINEW/O WITH OUTWP WEATHERPROOFWT WEIGHTWTP WATERPROOFINGPROJECT DIRECTORYOWNER: THE OLD SALOON LLCP.O. BOX 704GALLATIN GATEWAY, MT 59730(406) 223-8332CONTACT: BRETT EVJEARCHITECT:BECHTLE ARCHITECTS4515 VALLEY COMMONS DRIVE #201BOZEMAN, MT 59718(406) 585-4161CONTACT: SCOTT BECHTLEGENERAL CONTRACTOR:XXXXSTRUCTURAL ENGINEER:BRIDGER ENGINEERS, INC.2150 ANALYSIS DRIVE SUITE BBOZEMAN, MT 59718(406) 587-2917CONTACT: BREN RASMUSSENPLUMBING ENGINEERENERGY 12042 STADIUM DR #2BOZEMAN, MT 59715(406) 587-2917CONTACT: JEN BURGETTELECTRICAL ENGINEER:ENERGY 12042 STADIUM DR #2BOZEMAN, MT 59715(406) 587-2917CONTACT: JEN BURGETTMECHANICAL ENGINEER:ENERGY 12042 STADIUM DR #2BOZEMAN, MT 59715(406) 587-2917CONTACT: JEN BURGETTPROJECT SITE:35 EAST MAIN STREETBOZEMAN, MONTANACODE INFORMATION:APPLICABLE CODES: (STATE OF MONTANA)-INTERNATIONAL BUILDING CODE, 2021 EDITION-2021 EDITION OF THE INTERNATIONAL EXISTING BUILDING CODE-INTERNATIONAL RESIDENTIAL CODE, 2021 EDITION-UNIFORM PLUMBING CODE, 2021 EDITION-INTERNATIONAL MECHANICAL CODE, 2021 EDITION-INTERNATIONAL FUEL GAS CODE, 2021 EDITION-NATIONAL ELECTRICAL CODE, 2020 EDITION-INTERNATIONAL ENERGY CONSERVATION CODE, 2021 EDITION-INTERNATIONAL FIRE CODE 2021-NFPA 99C, 2014 EDITION ZONING: B3FIRE SPRINKLERS: NFPA13BUILDING CONSTRUCTION TYPE: IIIBBUILDING OCCUPANCY TYPE: B, M, S & A2BUILDING OCCUPANCY LOAD: 210ALLOWABLE BUILDING HEIGHT: 55 FEETACTUAL BUILDING HEIGHT: 36 FEET (EXISTING)BUILDING AREA:BASEMENT: 5,234 SFMAIN LEVEL: 5,234 SFUPPER LEVEL: 337 SF TOTAL: 10,805 SFPROJECT INFORMATIONAROOM TAGWINDOW NUMBERDOOR NUMBERPLAN NOTEGRID HEADNORTH ARROWPROJECT SYMBOLSROOM NAME101x1XXXA1011SIMDETAIL CALLOUTSECTION HEADWALL SECTION HEADSPOT ELEVATION1A101SIM1A101SIM14/16/15REVISION TAGDESIGN AND CONSTRUCTION DOCUMENT SERVICES AS IT PERTAINS TO AN INTERIOR BAR REMODEL IN AN EXISTING BUILDING.SCOPE OF WORKAny unauthorized reproduction or use of this information without the expressed written consent of Bechtle Architects is a violation of U.S. copyright laws. Copyright © 2024 Bechtle ArchitectsJOB:4515 Valley Commons Drive #201 Bozeman, MT 59718406.585.4161 ph 406.585.6919 faxBECHTLEARCHITECTSTHIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE5/30/2025 2:55:41 PMAutodesk Docs://2425_Powderhorn Saloon/2425_PowderhornSaloon_Central_V24_nathanielz.rvtSTOCKMAN SALOONBOZEMAN, MT2425SUP001COVER SHEETPERMIT SET -SUPMAY 30, 202535 EAST MAIN ST.BOZEMAN, MONTANASTOCKMAN SALOONVICINITY MAPPROJECT SITEREVISION SCHEDULENO. DESCRIPTION DATESHEET INDEX (SUP)GENERALSUP001 COVER SHEETSUP002 CODE PLANSSUPSUP100 ARCHITECTURAL SITE PLANSUP101 BASEMENT PLANSUP102 MAIN FLOOR PLANMINIMUM REQUIREMENTS. THE NUMBER OF SPACES SHOWN IN TABLE 38.540.050-3 MUST BE PROVIDED SUBJECT TO THE ADJUSTMENTS ALLOWED BY THIS DIVISION 38.540. SPACES ARE NOT REQUIRED TO BE PROVIDED FREE TO THE USER.PARKING SPACES REUIRED - UDC 38.540.050.A.3.b.(4)ALL REAL PROPERTY ASSESSED BY SPECIAL IMPROVEMENT DISTRICT (SID) NO. 565, OR OTHER SIMILARLY ADOPTED IMPROVEMENT DISTRICTS DESIGNED TO PROVIDE ADDITIONAL PARKING SPACES WITHIN THE B-3 DISTRICT, WILL NOT BE REQUIRED TO PROVIDE ADDITIONAL PARKING SPACES BEYOND THOSE REQUIRED AT THE TIME OF THE SID ADOPTION, PROVIDED THE USE OF THE REAL PROPERTY AND IMPROVEMTNS REMIANS UNCHANGED FROM THE INITIAL ASSESSMENTS OF SID NO 565, OR OTHER SIMILARLY ADOPTED IMPROVEMENT DISTRICTS.a. IN THE EVENT THAT A NEW USE OR AN EXPANSION IS INITIATED ON ANY PORTION OF THE REAL PROPERTY OR IMPROVEMENTS ARE MADE SUBSEQUENT TO THE ASSESSMENTS FOR SID NO. 565 OR OTHER SIMILARLY ADOPTED IMPROVEMENT DISTRICTS, THEN PARKING SPACE REQUIREMENTS MUST BE SATISFIED PRIOR TO INITIATION OF THOSE NEW OR EXPANDED USES.72.6 PARKING SPACES WERE PAID FOR INTO SID 565PARKING SPACES REUIRED - UDC (Table 38.540.050-3)RESTRAUNT, CAFES, BARS AND SIMILAR USES: 1 SPACE PER 50 SQUARE FEET OF INDOOR PUBLIC SERVING AREA.OFFICES: 1 SPACE PER 250 SQUARE FEET OF FLOOR AREA.WAREHOUSING, STORAGE, OR HANDLING OF BULK GOOD: 1 SPACE PER 1,000 SQUARE FEET OF FLOOR AREA DEVOTED TO STORAGE OF GOODS.PARKING CALCULATION - EXISTINGRETAIL AREA: 10,960 SF - 3,000 SF = 7,960 X 35% = 2786 / 300 9 SPACESOFFICE AREA: 11,060 SF X 55% - 6,083 / 250 24 SPACESSTORAGE AREA: 11,060 X 45% = 4,977 / 1000 5 SPACESTOTAL EXISTING REQUIRED PARKING SPACES = 38 PARKING SPACESPARKING CALCULATION - NEWRESTAURANT/BAR AREA: 2,094 SF X 25% = 523.5 / 50 10 SPACESRETAIL AREA: 7,056 SF - 3,000 SF = 4,056 X 35% = 1,419 / 300 5 SPACES OFFICE AREA: 11,060 SF X 55% = 6,083 / 250 24 SPACESSTORAGE AREA: 11,243 SF X 45% = 5,059 / 1000 5 SPACESTOTAL REQUIRED PARKING SPACES = 44 PARKING SPACESTOTAL PROVIDED PARKING SPACE = 72.6 PARKING SPACES, PER SID 565REDUCTIONS ALLOWED - UDC (38.540.050.A.2.C)(1) NEIGHBORHOOD COMMERCIAL. WITHIN THE B-1 AND R-O ZONING DISTRICTS IMPLEMENTING A SMALL SCALE COMMUNITY COMMERCIAL MIXED USE GROWTH POLICY DESIGNATION OR THE B-3 ZONING DISTRICT, THE PARKING REQUIREMENTS FOR NON-RESIDENTIAL USES MAY BE REDUCED.(TABLE 38.540.050-4)• RETAIL : 40%• RESTAURANT : 50%• OFFICE : 20%• ALL OTHERS : 30%(3) TRANSIT AVAILABILITY. REQUIRED PARKING MAY BE REDUCED BY TEN PERCENT IN CIRCUMSTANCES WHERE THE DEVELOPMENT IS WITHIN 800 FEET OF A DEVELOPED AND SERVICED TRANSIT STOP. FOR THE PURPOSE OF THIS SUBSECTION A TRANSIT STOP IS ELIGIBLE WHEN IT HAS PUBLICLY AVAILABLE COVER FROM WEATHER APPROVED BY THE TRANSIT PROVIDER TO BE EQUIVALENT TO A TRANSIT SHELTER, AND SERVICE IS PROVIDED ON NOT LESS THAN AN HOURLY SCHEDULE A MINIMUM OF FIVE DAYS PER WEEK.(4) STRUCTURED PARKING. AN ADDITIONAL 15 PERCENT REDUCTION MAY BE TAKEN WHEN THE SITE IS WITHIN 800 FEET OF A PARKING STRUCTURE OF AT LEAST 200 SPACES, WHICH IS AVAILABLE TO THE GENERAL PUBLIC, AND FOR WHICH A FEE FOR PARKING IS CHARGED. (5) THE FIRST 3,000 GROSS SQUARE FEET OF A NON-RESIDENTIAL BUILDING WITHIN THE B-3 DISTRICT OR ADJACENT TO DESIGNATED STOREFRONT BLOCK FRONTAGE PER SECTION 38.500.010 IS NOT INCLUDED IN THE CALCULATION OF REQUIRED PARKING.CH 38 - UDC - ARTICLE 5 - SEC. 38.540.070. - OFF-SITE PARKING.5. OFF-SITE PARKING FOR NON-RESIDENTIAL USES MAY NOT BE LOCATED MORE THAN 1,000 FEET FROM THE ENTRANCE OF THE PRINCIPAL USE. THE DISTANCE IS MEASURED ON A PEDESTRIAN ROUTE OF TRAVEL SUCH AS A SIDEWALK OR CITY STANDARD TRAIL FROM THE NEAREST PARKING SPACE TO THE ENTRANCE OF THE PRINCIPAL USE SERVED; AND6. ANY USE WHICH DEPENDS UPON OFF-SIT PARKING TO MEET THE REQUIREMENTS OF THIS CHAPTER MUST MAINTAIN OWNERSHIP OR PROVIDE EVIDENCE OF A LONG-TERM LEASE AGREEMENT, REVOCABLE WITH REVIEW AUTHORITY APPROVAL, RUNNING WITH THE TERM OF THE DESIGNATED USE, FOR PARKING UTILIZATION OF THE OFF-SITE LOCATION.PARKING CALCULATIONSN O T F O R C O N S T R U C T IO N NAC Scott Bechtle 1914 ES D A R NLECITS H TCETIANETfoOM T A BECHTLE ARCHITECTS