Loading...
HomeMy WebLinkAbout055 - SD-3 - STANDARD DETAILS -- -----,----- WSIDE OF � -� �- - -- --- STRUCTURE OR � � TOP OF FLOOR iiiiiiiiiiiiiii . OVERSIZE _ SLEEVE BUILDING WALL � WIRING DEVICE� OR ELECTRICAL � EQUIPMENT SIZE \ �WALL OR COLUMN AS REQUIRED �- . LFMC .. �, � .. � . . , - JUNCTION BOX ADJUSTABLE GLAND—I '. _ LB CONDULEfS CONDUIT----__ TO MOTOR, INSTRUMENT� RATED FOR LOCATION LOCATED WHERE , OR PIPE GROUNDING ACCESSIBLE . — —_ �"� PIPE STRAP I — — — — — — — — — — — ,�`— FOR SEALING FOR CONTROL RGS — ___ �I/ STATIONS MOUNT CONDUIT � 4�_p�• f CONCRETE SLAB SEE 16053 FLOOR OR�, NOTES: PLATFORM ''� FINISHED GRADE 1. USE WATERTIGHT CONDUIT SEAL WHERE CONDUIT . PENETRATIONS OF BUILDING EXTERIOR WALLS ARE � BELOW GRADE, OR FOR IDENTIFIED PENEfRATIONS � VI II OF FLOOR SLABS ON GRADE. �\� i I I NOTE 2 SPACING BEfWEEN OUTSIDE EDGES OF SLEEVES ALL MOUNTING HARDWARE SHALL BE GALVANIZED SHALL BE AS FOLLOWS: - .- �\ � STEEL (UNLESS SST NOTED). ON CONCRETE WALLS, \ — USE MALLEABLE IRON WSERTS. MOUNT ENCLOSURE 3'" FOR 2" CONDUIT AND LARGER J ON Ya" SPACERS OF Yz" RIGID CONDUIL 2" FOR 1Yz" CONDUIT AND SMALLER CONDUIT ENTRANCE �so�o WALL OR COLUMN MOUNTED DEVICE �6�oi CONDUIT RISER 16056 WATERTIGHT CONDUIT SEAL 16053 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE REWFORCING INTERUPTED BY OPENING,(U.N.O.) OPNG. AS REQ"D 6"' PIPE c� �� � U.N.O., PROVIDE BARS w� AREA EQUAL TO INTERUPTED REINF. o PLACE 1 2 OF THIS REWF. EA. �; RLL WITH WATERPROOF STANDARD WEIGHT STEEL PIPE ��� � Q EXPANDING SEALANT UNLESS SLEEVE. HOT DIP GALVANIZED \,` m SIDE OF OPNG. � 3" MAX. LWK SEAL NOTED. JOINT AFTER FABRICATION. SEE 15605 STANDON MODEL C92 SPACING. o SHALL BE WATERTIGHT N z I ADJUSTABLE PIPE SADDLE Q � CLAMP SUPPORT � # 4" UNLESS SHOWN PROVIDE 1� Sx4'-0'" DIAGONAL � — OTHERWISE ON PLANS =— EA. LAYER OF REWF.— 4 CORNERS o PROVIDE 1�#4 HOOP � EA. `� PAINT SAME AS PIPING �P LAYER OF REINF. OMIT FOR LAP F OR PROVIDE 304 __ _ OPENING DIA. < 12'" SPLICE A =-- ATTACH TO CONCRETE w/ 4 SPLICE STAINLESS STEEL =- TYP. / STAINLESS STEEL CONCRETE NP. // ANCHORS � PROVIDE SEEP���RINGJ �lYz� GROUT PASSWG �PII E � � , UNLESS OTHERWISE NOTED I C j NOTES: �PIPE FLANGE r 1. lYPICAL FOR ALL OPENINGS IN CONCREfE, UNLESS NOTED OTHERWISE. O.D. +2" MIN. 2. DO NOT WELD REINF. TO PIPE SLEEVES OR INSERTS. ¢ NOTE: 3. PROVIDE MINIMUM LAP AS NOTED OR SHOWN ON PLANS. g NOTE PROVIDE HALF ROUND RIGID INSULATION AND INSULATION o COAT & LINE FLOOR SLEEVE w/ SPECIFIED PROTECTION SHIELD, SIMILAR TO ANVIL FIGURE 167 OR ELCEN Q PAINT SYSTEM BEFORE CONCREfE PLACEMENL FIGURE 219, WHERE PIPING IS INSULATED. z FLOOR SLEEVE DETAIL isszz PIPE SUPPORT �55�� REINF. FOR OPENINGS IN WALLS AND SLABS 33os � SCALE: NONE SCALE: NONE SCALE: NONE 0 ° AGENCY REVIEW (REVISION 2) JUNE 2025 J REVISIONS J veaiFv SCn�e�. DRAWN BY: KJS PROJECT NUMBER � _,al�'�A�J �>> NO. DESCRIPTION BY DATE y' --C�` � �� 10678.001 mesePrzmrsnnnvserzeouceo. MOI �ISO� � 2880TechnologyBlvdWest DSGN.BY: LRH NORTONRANCHLIFTSTATIONUPGRADES a LINE BELOW MEASURES ONE INCH ■■ �^� ���� oN orziciNn�oanwiNc. � Bozeman,MT 59718 , qppR.BY: LRH SHEET NUMBER ,� BOZEMAN MONTANA 56 �--F � M a i e r I e 406 58�0�2, �A W. � No.48 6 PE=J DATE: O6/2025 DRAWWG NUMBER MooiFvscn�enccoaowc�v� � www.m-m.net �`%�ssqe%s97EREo�G� q.C.REVIEW STANDARDDETAILS 1�1 engineers surveyors planners scientists ��'4�ONAL`�`� BY� v D�� a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 DATE: