Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
051 - E-13 - PUMP CNTRL WIRING
4N24VAC120VACX01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X17X18X19X20X21X22X23X24X25X26X27X28X29X30X31X32X33X34X35X36X37X38X39940X01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X17X18X19X20X21X22X23X24X25X26X27X28X29X30X31X32X33X34X35X36X37X38X39940from E-12from E-1213120VAC24VACFUXXXCONTROL PANELFIELD OR AS NOTEDSF902FLYGT14-40 71 296 (120VAC)2 (24VAC/VDC)7+5-1012VDCOVERTEMP314LEAKAGE8119IN 110/2/11DI:2/11DIIN 100/2/10DI:2/10DITYPICAL PUMPSUBMERSIBLE PUMPMONITORING MODULEFLYGT MINICAS(APPLICABLE TO ALL 3PUMPS, WIRE EACHINDIVIDUALLY AS SHOWNHERE)TYPICALPUMP OVERTEMPTYPICALPUMP SEAL FAILFU912I out 3+0/5/3AO:5/3AOTYPICALLEVEL DISPLAYANLG COMANALOG LEVEL DISPLAYLITRED LIONPAXLA002716PWRETM1010000000SHLD1037720000103772000010377200001037720000103772000010377200001010000000SHLD10377200004103772000041A1AFUXXX1A10377200001037720000GENERATORVERIFYTERMINALS103772000010377200001037720000IN 10/3/1DI:3/1DIIN 20/3/2DI:3/2DIFUXXX1A10377200001037720000ATSVERIFYTERMINALS1037720000IN 40/3/4DI:3/4DI1037720000IN 30/3/3DI:3/3DIGENERATOR LOWBATTERY VOLTAGE(FROM GENERATOR)GENERATOR RUNNING(FROM GENERATOR)ATS IN GENERATORPOSITION (FROM ATS)ATS IN GENERATORPOSITION (FROM ATS)VERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2025COPYRIGHT © MORRISON-MAIERLE,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYP:\10678-LAUREL PARKWAY LLC\001 - NORTON RANCH LIFT STATION\ACAD\SHEETS\7-ELECTRICAL\E-13_EXST_PUMP_MONITORS.DWGREVISIONS DRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierlePLOTTED BY:LEE HAGEMAN ON Jun/04/2025 NORTON RANCH LIFT STATION UPGRADES BOZEMANMONTANAPUMP MONITORING AND LEVEL DISPLAY CONTROL WIRING10678.00151E-13MBHBCLBCL06/2025 AGENCY REVIEW (REVISION 2)JUNE 2025RECORD DRAWINGS NOTEA.UPDATE ALL SCADA PANEL, NOR-101, WIRING DRAWINGS TO MATCHAS-BUILT CONDITIONS. WRITE SUPERCEDED ON ANY PREVIOUSDRAWINGS THAT ARE NO LONGER APPLICABLE TO THIS PROJECT.GENERAL NOTESA.ADJUST WIRING AS NECESSARY FOR ACTUAL EQUIPMENTINSTALLED ON THIS PROJECT. VERIFY EXACT INPUTS ANDOUTPUTS IN THE FIELD. I/O SHOWN IS FROM PREVIOUS PROJECTDOCUMENTS AND MAY NEED TO CHANGE FOR THIS PROJECT.B.LOGIC SHOWN ADAPTED FROM IPS PROJECT 2146, NORTON RANCHLS IMPROVEMENTS NOR-101 PROJECT DRAWINGS. FIELD VERIFYAND ADJUST TO EXISTING CONDITIONS FOR A COMPLETEOPERATIONAL SYSTEM.05/29/20253E-811KEY NOTESSEE DETAIL FOR ADDITIONAL INFORMATION.