HomeMy WebLinkAbout050 - E-12 - TYP PUMP WIRING FlELD OR AS NOTED MCC SECTION EXISTING CONTROL PANEL AIRGAPPANEL raviKtsnoo 24VAC 120VAC 24VAC 120VAC CONTINUED DV/DT FILTER DVDT802 n n p�q�� n n XQ� I OR EQUAL MCC MOUNTED VFD I PUMP 1 REQUIRED X01 i 6A 10 HP �0:411 2�A DO ' 17 FLA �� ' X02 �--- -- —�-----�-- A2 A1 802 U/T1 R/L1 I I OUT1 X02 I PUMP1 � X03 6.SHP ---- -- —�-----�-- B2 B1 803 V/T2 S/L2 j\ MCCBUS I X03 ioEc � RJ2S-CL-A120 X04 480VAC I �--- -- —�-----�-- C2 C1 804 W/T3 TIL3 �\ I 1A28 PUMP1REQUIRED X04 8.2 FLA 3440 RPM � s�zs-osaw XOS �—_------ _�—_---I------------- PE PE I N0811,828 X05 X06 I I XO6 X07 MOTORSEALFAIL ----�— --y—�toPUMPMONITORS,E-13 I X07 AND X08 TEMPERATURE SENSOR ____�_ __�—�to PUMP MONITORS,E-13 I FU AXX XOS XQy I (RUN ENABLEj01 I CR724 X09 . . 9 1 CONTINUED I LOW LEVEL CUTOFF X10 I (STARTIRUN FWD)02 —1— CR715 X10 II CR804 9 5 X11 � (RUN PRESET SPEED 1)03 ___ FLOAT MODE X11 3 4 PUMPS REQUIRED Ip�Mp� I PUMP 1 REQUIRED X12 (DIG COM)04 SSXXX — — X�2 I OFF I HAND AUTO CR717 X13 05 � I Ae I OOX I 3 4 X13 BOOH-JR2B FLOAT MODE x�q (SELECT SPEED 420mA)06 to X28 � PUMPS REQUIRED I � XOO I X14 � X15 (DI7)07 ---- toE-8 � . I �FLOAT RUN � OOX T X15 I X16 I (DI8)OS I —}— IN 4 O1214 PUMP 1 Xi6 � ��;Z�4 LOCAL IN AUTO . I . DI X�� I �+zav oc�ii rrom xa���aoX I xn � X18 I \\\ to E-8 � � iaeoas0000 IN 5 p�Z255 PUMP 1 X18 XOO LOCALIN HAN� �FLOAT RUN FU819 g�g DI X19 I ` I 1A X19 I (N.O.)17 I X20 X20 (COM)19 Ol3/5 PUMP 1 XZ� I I IN 5 DI:3/5 VFD RUNNING X2� I (COM)19 I DI X22 X22 (N.C.)18 I O1316 PUMP 1 X23 I —t— IN 6 DI:3I6 VFD FAIL X23 I I DI X24 . . X24 X25 I —I— I out 0+ 0/5/0 PUMP 1 IVOLTAGE INPUT I I I I I AO AO�S/a SPEED COMMAND X25 X26 � (+10V�C)12 --- ANLG COM X26 X27 � (0-10VIN)13 � SHLD I SHLD I I �--�—�—�— � X27 CR804 xpg ' (ANALOG COM)14 PUMP 1 RUNNING from X14�0 � - 6 5 817 X28 I �Rg2g I PUMP 1 REQUIRED N N � X29 I 1 A2 8 I X29 o HIMXXX . ANALOG INPUT sdzs-asaw NO X37 . � X30 I � (4-20mAINPUT)15 NC X40 I X30 iosnzooao 000 817 � X31 I oo ta X17 a�—+— X31 � oo ANALOG OUTPUT I OI7I0 X32 RECORD DRAW WGS NOTE � (ANA�oc ourPur�is I I � I I I in 0+ AI AI:7/0 SPEED FEEDBACK X32 o X33 A. UPDATE ALL SCADA PANEL,NOT-101,WIRING DRAWINGS TO MATCH HIM � I VII in 0- X33 - AS-BUILT CONDITIONS.WRITE SUPERCEDED ON ANY PREVIOUS � w DRAWINGS THAT ARE NO LONGER APPLICABLE TO THIS PROJECT. CAT6 � SHLD SHLD I w X34 P�MP� --------btoENET �--�—+—�— -----� ANLGCOM X34 � ——— � GENERAL NOTES OTHER VFD RATINGS: X35 VFD PUMP#2-60HP,96 FLA,125A CB. I FUXXX X35 A. ADJUST WIRING AS NECESSARY FOR ACTUAL EQUIPMENT VFD PUMP#3-60HP,96 FLA,125A CB. PUMP 1 ON ' �A � INSTALLED ON THIS PROJECT. LTXXX g X36 B. LOGIC SHOWN ADAPTED FROM IPS PROJECT 2146,NORTON RANCH � i CR829 I X36 o LS IMPROVEMENTS NOR-101 PROJECT DRAWINGS.FIELD VERIFY L2 C' B1 3 4 Q AND ADJUST TO EXISTING CONDITIONS FOR A WMPLETE � � PUMP 1 RUNN WG X37 OPERATIONAL SYSTEM. N , N X37 � C. FOR LARGER MOTORS(60HP)PROVIDE 1000V,150A RATED POWER I ❑ J DISTRIBUTION BLOCKS INSTEAD OF TERMINAL BLOCKS. z X38 D. PUMP 1 WIRING SHOWN,ADJUST AS NECESSARY FOR PUMPS 2 X38 � AN D 3. I o X39 � LTXXX � i CR829 X39 � LZ R B� PUMP31 RUNNWG I ENCY REVIEW (REVISION 2) 840 I PUMP 1 OFF q3 / 840 JUNE 2025 J REVISIONS J veaiFvsCn�e�. ,•°"��� ""'„ DRAWNBY: MBH PROJECTNUMBER � NO. DESCRIPTION BY DATE y' .�� �NT� "'c 10678.001 mesePrzmrsnnnvserzeouceo. MOI �ISO� 2880Techno�o s��dwest ` r"" -� DSGN.BY: BCL NORTONRANCHLIFTSTATIONUPGRADES a LINE BELOW MEASURES ONE INCH � BRIAN C. 9Y ��7ft `_�`�, oNorziciNn�oanwiNc. ■■ � LITERSKI ` SHEETNUMBER eozeman,mr es��a f : APPR.BY: BCL gOZEMAN MONTANA so �--F � M a i e r I e � �� 16554PE ,�w� DATE O6/2025 DRAWING NUMBER 7 oT= s/z/ozs �u = MooiFvscn�enccoaowc�v� � www.m-m.net •�„ F: �� pf�;� q.C.REVIEW engineers surveyors planners scientists '•,,, S�EN�E��,�„�,�� BY TYPICAL PUMP WIRING E-12 a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 �NAL DATE: