Loading...
HomeMy WebLinkAbout049 - E-11 - SCADA CNTRL WIRINGLSHH-100-1-3FLOAT SWITCHBLKWHTGNDAIR GAP PANELCONTINUEDCONTINUED TO 801BLKWHTGNDGNDGNDGNDGNDFIELD OR AS NOTEDCONTROL PANEL41425152CH2CH1PR ELECTRONICS5202B2EX-AREAPWR33 +31 -111213212223FUXXX1A13120VAC24VACX01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X17X18X19X20X21X22X23X24X25X26X27X28X29X30X31X32X33X34X35X36X37X38X39740X01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X17X18X19X20X21X22X23X24X25X26X27X28X29X30X31X32X33X34X35X36X37X38X39740IN 20/2/2DI:2/2DIHIGH HIGH LEVELFLOATIN 30/2/3DI:2/3DIHIGH LEVELFLOATOUT 40/4/4DO:4/4DOLOW LEVEL CUT OFFA2RJ2S-CL-A120CR70518A2RTE-P2AF20ON DELAY21065HIGH HIGH FLOATFM RELAYSHIGH HIGH LEVELRELAYNO 719NCA4IDECRU4S-C-A110CR7151413A4IDECRU4S-C-A110CR7171413A2RJ2S-CL-A120CR71918NO 719NCFLOAT MODEPUMPS REQUIREDNO 810,910,1010NCFM PUMPS STOPDELAYNO 728NCFLOAT MODEPUMPS REQUIREDNO 813,913,1013NCA4IDECRU4S-C-A110CR7241413A2RTE-P2AF20OFF DELAYTD72721065CR71934LOW LEVEL CUT OFFNO 809,909,1009NCNONC4N24VAC120VACON DELAY119OFF DELAY119SJ2S-05BWSY4S-05LSH-100-1-3FLOAT SWITCHLSHH-100-2-1FLOAT SWITCHBLKWHTGNDAIR GAP PANELCONTINUEDCONTINUEDBLKWHTGNDGNDGNDGNDGND41425152CH2CH12 CHANNEL DISCRETEIS BARRIERPR ELECTRONICS5202B2EX-AREAPWR33 +31 -111213212223FUXXX1ALSLL-100-2-2FLOAT SWITCHSEE E-8SEE E-8LSLL-100-1-2FLOAT SWITCHBLKWHTGNDAIR GAP PANELCONTINUEDGNDGND41425152CH2CH1PR ELECTRONICS5202B2EX-AREAPWR33 +31 -111213212223FUXXX1A2 CHANNEL DISCRETEIS BARRIER2 CHANNEL DISCRETEIS BARRIERIN 150/3/15DI:3/15DILOW LEVELFLOATVERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2025COPYRIGHT © MORRISON-MAIERLE,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYP:\10678-LAUREL PARKWAY LLC\001 - NORTON RANCH LIFT STATION\ACAD\SHEETS\7-ELECTRICAL\E-11_EXST_FLOAT_MODE.DWGREVISIONS DRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierlePLOTTED BY:LEE HAGEMAN ON Jun/04/2025 NORTON RANCH LIFT STATION UPGRADES BOZEMANMONTANASCADA FLOAT MODE CONTROL WIRING10678.00149E-11MBHBCLBCL06/2025 AGENCY REVIEW (REVISION 2)JUNE 2025RECORD DRAWINGS NOTEA.UPDATE ALL SCADA PANEL, NOR-101, WIRING DRAWINGS TO MATCHAS-BUILT CONDITIONS. WRITE SUPERCEDED ON ANY PREVIOUSDRAWINGS THAT ARE NO LONGER APPLICABLE TO THIS PROJECT.GENERAL NOTESA.ADJUST WIRING AS NECESSARY FOR ACTUAL EQUIPMENTINSTALLED ON THIS PROJECT. VERIFY EXACT INPUTS ANDOUTPUTS IN THE FIELD. I/O SHOWN IS FROM PREVIOUS PROJECTDOCUMENTS AND MAY NEED TO CHANGE FOR THIS PROJECT.B.LOGIC SHOWN ADAPTED FROM IPS PROJECT 2146, NORTON RANCHLS IMPROVEMENTS NOR-101 PROJECT DRAWINGS. FIELD VERIFYAND ADJUST TO EXISTING CONDITIONS FOR A COMPLETEOPERATIONAL SYSTEM.C.LOGIC SHOWN IN CONTROL PANEL ON THIS SHEET IS FOREXISTING SCADA BACK-UP FLOAT MODE CONTROL, ADJUST ASNECESSARY TO UPDATE SYSTEM.05/29/2025