HomeMy WebLinkAbout048 - E-10 - TYP ANALOG INSTR WIRING FlELD OR AS NOTED CONTROL PANEL I120VAC 24VAC 24VAC 120VAC � n n n n X01 I X01 1 CHANNEL ANALOG IS BARRIER X02 I ISBX04 X02 � PR ELECTRONICS I 51046B2A X03 AIR GAP PANEL X03 CONTINUE� EXAREA PWR FUXXX X04 33+ ���q�� X04 / `\ +q4 31- XOS XOS TYPICAL �/ � . -----_--- —�-------�-----� I� SUBMERSIBLE LEVEL 1 LT I I I XO6 TRANSMITTER � / _ _________ _�_____________ -42 XO6 �� i X07 I SHL�D �3+� I in 0+ OI1/0 TYPICAL WET WELL LEVEL X07 � —� AI:1I0 (APPLICABLE TO LE-100-1-A AI AND LE-100-1-B) X08 � 11-.. V/I in 0- XOS I X49 I ANLG COM X09 X10 ' X10 I X11 I X11 �� . FUXXX X�2 NPICALBUILDING �// � 2 � ��4A X12 TEMPERATURE � TIT X13 TRANSMITTER � 3 — I in 1+ 0/1/1 TYPICAL TEMPERATURE X13 / -------------------�---------------------------- AI:111 TRANSMITTER � � �— . I I AI (APPLICABLE TO TIT-101 AND X14 1 — Vll in 1- TIT-110) X14 ——————————————————— —————————————————————— SHLD � X15 4 I �--� ANLG COM X15 X16 L — ' — — ' — — ' — — ' � 4 X16 X17 I X17 X18 I X18 TYPICAL MAGNETIC X19 FLOW TRANSMITTER I X19 X20 —� L ———————————————————————�————————— X20 / \ \ I X21 FIT N ————————————————————————————————— X21 \ / X22 \�—� I X22 X23 + I I in 2+ 0/V2 TYPICAL FLOW METER X23 AI:1/2 (APPLICABLE TO RT-100-1-1 Iql AN�FIT 100-1-2) X24 - I Vll in 2- X24 SHLD � X25 i ,1 --� ANLG COM X25 X26 I X26 X27 I X27 X28 I X28 0 X29 I X29 � X30 I X30 0 a X31 I X31 X32 I X32 � X33 I X33 W x34 RECORD DRAWWGS NOTE I x34 X35 A. UPDATE ALL SCADA PANEL,NOR-101,WIRING DRAWWGS TO MATCH I X35 " AS-BUILT CONDITIONS.WRITE SUPERCEDED ON ANY PREVIOUS � DRAWINGS THAT ARE NO LONGER APPLICABLE TO THIS PROJECT. g X36 I X36 ° GENERALNOTES I X37 A. ADJUST WIRING AS NECESSARY FOR ACTUAL EDUIPMENT I X37 - INSTALLED ON THIS PROJECT.VERIFV EXACT INPUTS AND z Xgg OUTPUTS IN THE RELD.I/O SHOWN IS FROM PREVIOUS PROJECT . X38 q� DOCUMENTS AND MAY NEED TO CHANGE FOR THIS PROJECT. I B. LOGIC SHOWN ADAPTED FROM IPS PROJECT 2146,NORTON RANCH ° X39 LS IMPROVEMENTS NOR-101 PROJECT DRAWINGS.FIELD VERIFY X39 o ANDADJUSTTOEXISTINGCONDITIONSFORACOMPLETE I A ENCY REVIEW (REVISION 2) OPERATIONALSYSTEM. 640 640 JUNE 2025 J REVISIONS J veaiFvsCn�e�. ,•°"��� ""'„ DRAWNBY: MBH PROJECTNUMBER � NO. DESCRIPTION BY DATE y' .�� �NT� "'c 10678.001 mesePrzmrsnnnvserzeouceo. MOI �ISO� 2880Techno�o s��dwest ` r"" -� DSGN.BY: BCL NORTONRANCHLIFTSTATIONUPGRADES a LINE BELOW MEASURES ONE INCH � BRIAN C. 9Y ��7ft `_�`�, oNorziciNn�oanwiNc. ■■ � LITERSKI ` SHEETNUMBER eozeman,mr es��a f : APPR.BY: BCL gOZEMAN MONTANA 4e ��_ 16554PE �w_ DATE: O6/2025 �--F � M a i e r I e � #F' DRAW WG NUMBER �oT_ „ozs �,; MooiFvscn�enccoaowc�v� � www.m-m.net ',,, F•S���ENSE�'���e q.c.Rewew TYPICALANALOG INSTRUMENTS WIRING E-10 engineers surveyors planners scientists .,� S� E� ,,.� BY: a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 �NAL DATE: