Loading...
HomeMy WebLinkAbout046 - E-8 - ELECTRICAL DETAILS UTILITY TRANSFORMER STAINLESS STEEL N EXTERIOR ENCLOSURE SHALL 24"x24"x10"ULSQ NEMA BE LOCKABLE AND 4X JUNCTION BOX LISTEDILABELED TO UL508A. NEMA 4X JUNCTION BOX. SW-01 JBOX BACK PLATE N G TOUCH-SAFE LOCKABLE HANDLE POWER AND ATS-01 CONTROLS N .:.��; TERMINALS G p ��� CONCRETE SLAB #2 #4 #2 #2/0 :;.' FOOTING EQUIPMENT GROUND TO WATER PIPEI REBAR(TYP) MCG01 PROCE55 PIPE UFER GND PREMISE #2/0 CU GROUNDING CONDUCTOR TIED GAS PIPE TO A MINIMUM 20FT,#5 A36 ROD.JOINT SHALL BE MADE BY EXOTHERMIC NEMA 7 SEALED WELDING PROCESS.LOCATED BELOW CABLE GLANDS ATS-01.WIRE TIE TO STRUCTURAL REBAR IN FOOTING. r r �� GROUNDING AND BONDING RISER DETAIL � I� I � � � E-C SCALE:N.T.S. STAINLESS STEEL � I� I � � � J AIR GAP AIR GAP I CABLESFROM PANEL � I� I � WET WELL � G I� I � � � � I� II � � BUILDING WALL WETWELL LEVEL LEVEL � DISPLAY LEVEL SIGNAL�}——— — FROMNOR-1010--- ----- � I� I � � � SEE E-13 LSHH � I� I � � � 120VACOF�RO�M� 100-2-1 RB' �NEUTRAL � g FROM NOR-101 � � � RB� LSLL SHROUD 3 4 100-2-2 RB2 �RB2$ NEMA 7 SEALED CABLE 3 4 GLANDS CONCRETE PAD BACK-UP PUMP CONDUIT W/ SELECTOR SWITCH BUSHING ENDS VFD 2(V+) PUMP 2 PUMP 3 R61 VFD 2(DI7) CONCRETE PAD SEEE-13 o--------0 I °XOO I�o--- � AB VFD 3(V+) eooH� RBZ VFD 3(DI7) o- -0 �OOX 3 i q o--- � II I I BUILDING FOOTING a? �� -� NOTE: �� �� �� �� �� A. VFD INPUTS SHALL BE PROGRAMMED TO OPERATE RESPECTNE � � �� �� �� �� VFD AT FULL SPEED TO DRAW DOWN THE WETWELL IN BACK-UP i � F � �� � " : _.. MODE. w B. LSHH-100-2-1 AN�LSLL-100-2-2 CLOSE ON RISING LEVEL AND OPEN �RGS SWEEP(TYP) ON FALLING LEVEL.INTRINSICALLY SAFE BARRIER NOT SHOWN � �PVC SCH 8Q(TYP) ABOVE. tt C. SELECTOR SWITCH ALLOWS OWNER TO SET EITHER PUMP#2 (LEA�)OR PUMP#3(LAG)TO BE THE BACK-UP MODE PUMP. ' D. PROVIDE A REDLION PAXLA000 OR EQUAL PROCESS METER TO � SHOW CURRENT WET WELL LEVEL.WET WELL LEVEL TO BE � NOTE: TRANSMITTED FROM SCADA PANEL,NOR-101,TO THE LEVEL U A. TERMINAL BLOCKS:WEIDMULLER OR SIMILAR FOR EACH TYPE OF �ISPLAY. PROVIDE ALL PANEL MOUNT ACCESSORIES AS NEEDED. - DISCRETE OR ANALOG SIGNAL E. PROVIDE NEMA 3R JUNCTION BOX,DIN RAIL,TERMINAL BLOCKS, B. 1000V POWER DISTRIBUTION BLOCKS:MERSEN MPDB SERIES WITH OPTIONAL RELAYS,TERMINATIONS,ETC FOR A COMPLETE SYSTEM. ISOLATE FLOAT SWITCHES USING AN INTRINSICALLY SAFE BARRIER. PANEL � SAFETY COVER OR EQUAL RATE�FOR 125%OF MOTOR CURRENT. TO MEET ALL UL 508A REQUIREMENTS. ¢ z C. CONTRACTOR MAY REUSE EXISTING PANEL.IF IT IS REUSED,THE CONTRACTOR ° MUSTUPGRADETHENUMBERANDNPEOFTERMINALBLOCKSTOMATCHNEW �3� LEVEL DISPLAYAND BACK-UP PUMP MODE DETAIL � PUMPSANDCONTROLS. J E-5, E-13 SCALE:N.T.S. � �� AIR GAP PANEL DETAIL ° E-3, E-5 SCALE:N.T.S. ° AGENCY REVIEW (REVISION 2) JUNE 2025 J REVISIONS J veaiFvsCn�e�. ,•°"��� ""'„ DRAWNBY: MBH PROJECTNUMBER � NO. DESCRIPTION BY DATE y' .�� �NT� "'c 10678.001 mesePrzmrsnnnvserzeouceo. MOI �ISO� 2880Techno�o s��dwest ` r"" -� DSGN.BY: BCL NORTONRANCHLIFTSTATIONUPGRADES a LINE BELOW MEASURES ONE INCH � BRIAN C. 9Y ��7ft `_�`�, oNorziciNn�oanwiNc. ■■ � LITERSKI ` SHEETNUMBER eozeman,mr es��a f : APPR.BY: BCL gOZEMAN MONTANA a6 �--F � M a i e r I e � �� 16554PE ,�w� DATE O6/2025 DRAWING NUMBER 7 oT= s/z/ozs �u = MooiFvscn�enccoaowc�v� � www.m-m.net •�„ F: �� pf�;� q.C.REVIEW engineers surveyors planners scientists '•,,, S�EN�E��,�„�,�� BY ELECTRICAL DETAILS ��Q a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 �NAL DATE: v