HomeMy WebLinkAbout039 - E-1 - ELECT LGNDS & SMBLS x � O � ALARM FLASHING LIGHT
��ZpA pR ��100AF LOW - VOLTAGE CIRCUIT BREAKER (CB�. �PT CONTROL POWER TRANSFORMER (CPT� p.QO NORMALLY CLOSED LIMIT SWITCH, $Y TOGGLE SWITCH X HEAT DEfECTOR
80AT RATINGS AND N0. OF POLES AS SHOWN. OPEN ON REACHING LIMIT SUBSCRIPT: X ALARM BELL AND FLASHING
� 3P 0 3P WHEN SPECIFIC NPE IS REQUIRED, X INDICATES SUBSCRIPTS: �
TYPE. X - INDICATES NPE R/C - RATE COMPENSATION �,� LIGHT COMBINATION UNIT
�— � FIELD WIRWG EXTERNAL TO CONTROL PANEL NONE - SINGLE POLE R/F - COMBINATION RATE OF I x L. ALARM HORN AND FLASHING
iYPES: �� VOLTAGE TRANSFORMER (Vi OR PT) /� 3 - THREE-WAY RISE AND FIXED TEMP L-S•� LIGHT COMBINATION UNIT
MCCB - MOLDED CASE �X� INTERLOCK; X INDICATES NPE 4 - FOUR-WAY R - RATE OF RISE
ICCB - WSULATED CASE \� TYPES: HP - TOGGLE SWITCH, HORSEPOWER RATED F - FIXED SUBSCRIPT:
LVP - LOW - VOLTAGE POWER � CURRENT TRANSFORMER (CT) K - KEY SWITCH � NONE - GENERAL ALARM
MCP - MOTOR CIRCUIT PROTECTOR E - ELECTRICAL TE - MANUAL MOTOR STARTER WITH THERMAL ELEMENT x ALARM BELL DEVICE
M - MECHANICAL
(RATING PER CONNECTED LOAD) OFF K - KEY P - PILOT LIGHT F - FIRE ALARM DEVICE
CB SEPARATELY MOUNTED CIRCUIT BREAKER; SEE L - LIGHTED HANDLE x
HAND AUTO ALARM HORN
ELECTRICAL ONE - LWE DIAGRAM OR �yH UTILITY WATT-HOUR METER PER UTILIN � Y - SWITCH NAME/DESIGNATION
REQUIREMENTS X00 3 POSITION SELECTOR SWITCH, MAINTAINED coNrncrs; ABBREVIATIONS:
SCHEDULE FOR DESCRIPTION UNLESS OTHERWISE NOTED, 2-POSITION SIMILAR SPECIAL-PURPOSE RECEPTACLE AS DEFWED ON PLANS
� OOX � A or AMP AMPERES UG UNDERGROUND
GFP GROUND FAULT PROTECTION � -Q AC ALTERNATING CURRENT UH UNIT HEATER
DMP DIGITAL METERING PACKAGE � NORMALLY OPEN PUSHBUTTON, MOMENTARY � PWG-IN RECEPTACLE STRIP, QUANTIlY AND SPACING OF AFF ABOVE FINISHED FLOOR
0 o CONTACT UNLESS OTHERWISE NOTED RECEPTACLES AS NOTED OR SPECIFIED ATS AUTOMATIC TRANSFER SWITCH V VOLT
52 MEDIUM - VOLTAGE CIRCUIT BRFAKER VA VOLT AMPERES
EfM ELAPSED TIME METER NORMALLY CLOSED PUSHBUTTON, MOMENTARY C CONDUIT VFD VARIABLE FREQUENCY
o I n CONTACT UNLESS OTHERWISE NOTED �` GROUNDING BUS CB CIRCUIT BREAKER
� FUSE, SIZE, AND NUMBER OF FUSES AS NOTED DRNE
t CKT CIRCUIT
�Q 1 GROUND �� INDICATING LIGHT. X INDICATES LENS COLOR N TELECOMMUNICATIONS OUTLET JUNCTION BOX CU COPPER W WATTS
D� FUSED CUTOUT, CURRENT RATING, FUSE SIZE, WP WEATHERPROOF
AND NUMBER OF POLES AS NOTED I PUSH TO TEST INDICATING LIGHT, X INDICATES
X � QUAD-DUPLEX RECEPTACLE, TWO NEMA 5-20R EF EXHAUST FAN
6 ELEC ELECTRIC
`� FUSIBLE SWITCH, CURRENT RATING, FUSE SIZE, � --o LENS COLOR Y UNDER COMMON COVER PLATE XFMR TRANSFORMER
LIGHTNING ARRESTER X EMT ELECTRICAL METALLIC TUBING
AND QUANTITY AS NOTED LENS COLORS: �.,q EXP EXPLOSION PROOF Y WYE CONNECTED
�-'c'Y DUPLEX RECEPTACLE, NEMA 5-20R
� NON-FUSED SWITCH, CURRENT RATING, AND R - RED Y - YELLOW
SPD LOW VOLTAGE SURGE PROTECTIVE DEVICE G - GREEN W - WHITE GFI GROUND FAULT INTERRUPTER Q DELTA CONNECTED
NUMBER OF POLES AS NOTED X GND GROUND
8 - BLUE A - AMBER � SIMPLEX RECEPTACLE, NEMA 5-20R
^ DISCONNECT OR DRAWOUT CONNECTION � �T TRANSFORMER Y � PHASE
ELECTRICAL CONNECTION SUBSCRIPTS: HOA HAND-OFF-AUTOMATIC
X - INDICATES TYPE HP HORSEPOWER
MAGNETIC MOTOR STARTER AND SS SELECTOR SWITCH HVAC HEATING, VENTILATING &
A c� & A c� SEPARATELY MOUNTED COMBINATION MAGNEfIC I ,J� GFCI - GROUND FAULT CIRCUIT INTERRUPTER AIR CONDITIONING
B B MOTOR STARTER t OR�I L OR — NO ELECTRICAL CONNECTION pg PUSHBUTTON Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD
� HZ HERTZ
MOTOR CONTROLLER AND A IC � � CONDUIT TURNING UP J-BOX JUNCTION BOX
D c� & D o SEPARATELY MOUNTED MOTOR CONTROLLER WITH SV OR O--�L--O SOLENOID VALVE INSTRUMENTATION CONTROL DEVICE
SHORT CIRCUIT PROTECTION AND DISCONNECT � � CONDUIT TURNING DOWN kW KILOWATTS
� CONTROL PANEL INTEGRAL OR PROVIDED WITH kVA KILOVOLT AMPERES
MOTOR STARTER AND CONTROLLER SUBSCRIPTS: ASSOCIATED EQUIPMENT
O CONTROL/RELAY COIL; X INDICATES TYPE, �� HOME RUN TO PANEL, 2 #12, 1 #12G IN LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
A - MAGNEfIC STARTER NEMA SIZE Y Y INDICATES LOOP N0. WHEN USED 3 4"C UNLESS OTHERWISE NOTED MAN MANUAL
CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL OR
B - STARTER 71'PE TYPES: � PROVIDED WITH ASSOCIATED EQUIPMENT MCC MOTOR CONTROL CENTER
CR - CONTROL RELAY �-' HOME RUN WITH CONDUIT SEAL-OFF MECH MECHANICAL
NONE - FULL VOLTAGE NON-REVERSING (FVNR) �
FVR - FULL VOLTAGE REVERSING DP - DEFINITE PURPOSE RELAY O JUNCTION OR PULL BOX MFR MANUFACTURER
2S - TWO SPEED LC - LIGHTWG CONTACTOR
M - MOTOR STARTER PANELBOARD (250V TO 600V) CIRCUIT RUN BETWEEN DEVICES EXPOSED IN N NEUTRAL
RVAT - REDUCED VOLTAGE AUTO TRANSFORMER PC - PHOTO CELL _ NON-ARCHITECTURALLY FINISHED AREAS; NC NORMALLY CLOSED
C - CONTROL DIAGRAM OR CONTROLS TC - TIME CLOCK CONCEALED IN ARCHITECTURALLY FINISHED NEC NATIONAL ELECTRICAL CODE
TR - TIMING RELAY PANELBOARD (LESS THAN 250V) AREAS. CONDUIT AND CONDUCTOR SIZES SHALL NO NORMALLY OPEN
SCHEDULE NUMBER (IF REQUIRED) �
BE THE SAME AS THE HOMERUN FOR THE # NUMBER
D - CONTROLLER TYPE �� NORMALLY OPEN CONTACT (N.O.) CIRCUIT.
ELECTRICAL EQUIPMENT ENCLOSURE: SWITCHBOARD,
VFD - VARIABLE FREQUENCY DRIVE MOTOR CONTROL CENTER, CONTROL PANEL, OR OTHER — — — CONDUIT RUN BETWEEN DEVICES CONCEALED IN PB PUSHBUTTON
SS - SOLID STATE �`� NORMALLY CLOSED CONTACT (N.C.) EQUIPMENT AS INDICATED NON-ARCHITECTURALLY FINISHED AREAS OR PDR POWER DISTRIBUTION RECEPTACLE
UNDER FLOOR SLAB. CONDUIT AND CONDUCTOR PH PHASE
� SEPARATELY MOUNTED COMBINATION MOTOR NORMALLY OPEN TIME DELAY RELAY CONTACT SIZES SHALL BE THE SAME AS THE HOMERUN PNL PANEL
STARTER OR CONTROLLER; SEE ELECTRICAL � PVC POLYVINYL CHLORIDE CONDUIT
WITH TIME DELAY ON CLOSING AFTER COIL IS D MOTION DEfECTOR, PROVIDE POWER PACK AS NEEDED FOR THE CIRCUIT.
ONE - LINE DIAGRAM OR SCHEDULE FOR ENERGIZED PWR POWER
DESCRIPTION CIRCUIT HASH MARKS (WHEN INDICATED); LONG,
O-'� NORMALLY CLOSED TIME DELAY RELAY CONTACT PC PHOTOCELL SHORT, SINGLE DOT, AND DOUBLE DOT RECPT RECEPTACLE
� THERMAL OVERLOAD ELEMENT ^ WITH TIME DELAY ON OPENING AFTER COIL IS � REPRESENT PHASE, NEUTRAL, EQUIPMENT RGS RIGID GALVANIZED STEEL
ENERGIZED X CEILWG/PENDANT-MOUNTED LUMINAIRE - HID, GROUND, AND ISOLATED EQUIPMENT GROUND,
�yOL� � � NORMALLY OPEN TIME DELAY RELAY CONTACT �Y COMPACT FLUORESCENT, OR INCANDESCENT RESPECTIVELY. #12 IN 3/4" CONDUIT UNLESS SV SOLENOID VALVE
�`�- THERMAL OVERLOAD RELAY CONTACT WITH TIME DELAY ON OPENING AFTER COIL IS OTHERWISE INDICATED. SW SWITCH
DE-ENERGIZED �X WALL-MOUNTED LUMINAIRE - HID, COMPACT � CIRCUIT CONTINUATION SWBD SWITCHBOARD
'�-t Y FLUORESCENT, OR INCANDESCENT SWGR SWITCHGEAR
�1 DISCONNECT OR SAFETY SWITCH, 30A, 3P, NORMALLY CLOSED TIME DELAY RELAY CONTACT
NON-FUSED UNLESS OTHERWISE NOTED � WITH TIME DELAY ON CLOSING AFTER COIL IS z X � CONDUIT STUBBED OUT AND CAPPED T THERMOSTAT
DE-ENERGIZED � CEILWG/PENDANT-MOUNTED FLUORESCENT
Y TD TIME DELAY
Q FIXTURE XXX CONDUIT TAG OR CIRCUIT NUMBER - WIRE AND TEL TELEPHONE
O NORMALLY OPEN TEMPERATURE SWITCH; z X WALL-MOUNTED FLUORESCENT FIXTURE CONDUIT SIZE AS SPECIFIED IN CIRCUIT TTB TELEPHONE TERMINAL BOARD
7 1/2 OR HP � CLOSE ON RISING TEMPERATURE �Y SCHEDULE ON THE SHEEfS TX TRANSFORMER
< MOTOR WITH DESIGN HORSEPOWER
(WHEN INDICATED) � �Y CEILWG/PENDANT-MOUNTED FLUORESCENT
NORMALLY CLOSED TEMPERATURE SWITCH; � FIXTURE NORMAL/EMERGENCY GROUND CABLE
OPEN ON RISING TEMPERATURE
' X WALL-MOUNTED FLUORESCENT FIXTURE O
GROUND ROD
`� � CL�OSELON WCREASWG FLOWH� �Y NORMAL/EMERGENCY GENERAL NOTES:
� O GENERATOR �X EMERGENCY LIGHT FIXTURE� 2 ATTACHED HEADS FAA FIRE ALARM ANNUNCIATOR
� Y AS SHOWN
NORMALLY CLOSED FLOW SWITCH;
w TRANSFER SWITCH, CURRENT RATING, AND OPEN ON MCREASING FLOW X FACP FIRE ALARM CONTROL PANEL
W o� I EMERGENCY LIGHT, REMOTE MOUNTED HEAD � 1. THIS IS A STANDARD ELECTRICAL
NUMBER OF POLES AS NOTED Y SYMBOLOGY SHEET. NOT ALL
� SYMBOLS MAY BE USED ON THIS PROJECT.
ATS - AUTOMATIC NORMALLY OPEN LEVEL SWITCH, F
� ATS X X DOUBLE-FACED CEILING OR WALL-MOUNTED FIRE ALARM MANUAL PULL STATION
� MTS - MANUAL CLOSE ON RISING LEVEL
w � Y �Y EXIT LIGHT; DIRECTIONAL ARROWS QF REQUIRED) 2.SCREENING OR SHADING OF WORK IS USED
� NORMALLY CLOSED LEVEL SWITCH, AS INDICATED ON PLANS O TO INDICATE EXISTWG
OPEN ON RISING LEVEL �R FIRE ALARM CONTROL RELAY COMPONENTS OR TO DE-EMPHASIZE
- �v'�'v'� TRANSFORMER �X ��X SWGLE-FACED CEILING OR WALL-MOUNTED EXIT PROPOSED IMPROVEMENTS
I ppp��� Y Y LIGHT; DIRECTIONAL ARROWS (IF REqUIRED) AS Fg RRE ALARM CONTACT, FLOW SWITCH TO HIGHLIGHT SELECTED TRADE WORK.
i � 3-PHASE, 3-WIRE DELTA CONNECTION 7�o NORMALLY OPEN PRESSURE SWITCH, INDICATED ON PLANS
� `� 3-PHASE, 4-WIRE GROUNDED WYE � CLOSE ON WCREASING PRESSURE O REFER TO CONTEXT OF EACH
z CONNECTION � NORMALLY CLOSED PRESSURE SWITCH, �"�X AREA OR ROADWAY LIGHT - POLE-MOUNTED TS RRE ALARM CONTACT, TAMPER SWITCH SHEET FOR USAGE.
o Y PS RRE ALARM CONTACT, PRESSURE SWITCH 3.REFERENCES OTHER LEGEND SHEETS FOR
OPEN ON INCREASING PRESSURE
a �� SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, LIGHTING FIXTURE SUBSCRIPTS: PROJECT-SPECIFIC EQUIPMENT
N PHASE, NUMBER OF WIRES WHEN INDICATED X - INDICATES RXTURE 7`!PE PER LIGHTING SYMBOLS, EQUIPMENT ABBREVIATIONS, AND
J � NORMALLY CLOSED PRESSURE SWITCH, RXTURE SCHEDULE PIPWG SYSTEM ABBREVIATIONS.
OPEN ON INCREASING PRESSURE Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD OX AND � X SMOKE AND DUCT DETECTOR
z
� 100 0 NORMALLY OPEN LIMIT SWITCH, z - INDICATES CONTROLLING SWITCH (IF REQUIRED) SUBSCRIPT:
o KVA NON-MOTOR LOAD WITH DESIGN KVA, KW, OR � CLOSE ON REACHING LIMIT I - IONIZATION TYPE
AMP $m MANUAL MOTOR STARTER P - PHOTOELECTRIC TYPE
° AGENCY REVIEW (REVISION 2)
JUNE 2025
J REVISIONS
J veaiFvsCn�e�. ,•°"��� ""'„ DRAWNBY: MBH PROJECTNUMBER
� NO. DESCRIPTION BY DATE y' .�� �NT� "'c 10678.001
mesePrzmrsnnnvserzeouceo. MOI �ISO� 2880Techno�o s��dwest ` r"" -� DSGN.BY: BCL NORTONRANCHLIFTSTATIONUPGRADES
a LINE BELOW MEASURES ONE INCH � BRIAN C.
9Y ��7ft `_�`�,
oNorziciNn�oanwiNc. ■■ � LITERSKI ` SHEETNUMBER
eozeman,mr es��a f : APPR.BY: BCL gOZEMAN MONTANA 39
4�� 16554PE ��,.
�--F � M a i e r I e � ` A= #�`w- DATE O6/2025
DRAWING NUMBER
7 oT= s/z/ozs �u�_
MooiFvsen�enccoaowc�v� � www.m-m.net ',,, F•S���ENSE�'���,- q.c.Rewew ELECTRICAL LEGENDS AND SYMBOLS E��
engineers surveyors planners scientists .,� S� E� ,,.� BY:
a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 �NAL DATE: