HomeMy WebLinkAbout036 - H-3 - HVAC DETAILS CONTROL DRAWING LEGEND BUILDINGWALL LV-3 FAN LV-2� M o ERCo-2A �— CAULK ALL WEATHER O i SUPPORT WITH STEEL MAKE WEATHER TIGHT DAMPER WITH ACTUATOR ANGLE AS NEEDED M DAMPER CO-3-----1 _OUTSIDEAIR HEAD SECTION(JAMB SIMILAR) EXHAUST AIR GENERATOR BIRD SCREEN ANCHOR SECURELY TO WALL VARIABLE TEMPERATURE r \ 1�� CONSTRUCTION FREQUENCY 4 SENSOR oAMPER co ,\/ EXTRUDED ALUM.OR e DRIVE lr IMMERSION TYPE CAULK / I�GALV.STEEL LOUVER MODULATING 2-WAY CONTROL VALVE Pea co-2e \ (SEE SPECIFICATIONS) DUCT TEMPERATURE WITH ---------- ---"O ROOM THERMOSTAT n M onM IAYI SENSOR-SINGLE ACTUATOR r---------- ----r SHEET METAL POINT MODULATING 3-WAY SLEEVE SILL EXTENSION CONTROL VALVE 120V�' � WITH UH 22 SUPPLY __ ---- - --EF-2 T DUCT TEMPERATURE ACTUATOR CONTROLLER TILT DUCT AND MOTORIZED DAMPER SENSOR- 0 UC-1 MOTORIZED SLIGHTLY FOR DRAINAGE 2-POSITION INTERLOCK AVERAGING V-NG WITH EXHAUST FAN ELEMENT PUMP M MANUAL RE-SET FREEZE WALL LOUVER WITH CONTROL DAMPER DETAIL STAT COIL I N.T.S. SEQUENCE OF OPERATION FOR NEW DIESEL/GENERATOR ROOM: WHEN DIESEL GENERATOR IS RUNNING: DUCT PRESSURE SENSOR THERMOSTAT MANUAL RESET HIGH O ENABLING SIGNAL FOR /GENER START SHALL CAUSE CONTROL DAMPERS CD-2A,CD-2B,AND CD-4 TO GO FULL SUSPEND FROM LIMIT OUTSIDE AIR OPEN.CONTROL DAMPERR CD-CD- REMAIN SHALL REMAIN CLOSED. ABOVE TEMPERATURE HEATING: THREADED SUPPORT RODS n CONTROL DAMPER CD-2A SHALL MODULATE FROM 100%OPEN TO 100%CLOSED AND CONTROL DAMPER CD-3 SHALL DUCT STATIC SENSOR PRESSURE MODULATE FROM 100%CLOSED TO 100%OPEN TO MAINTAIN HEATING SETPOINT.CONTROL DAMPER CD-2B SHALL REMAIN FACTORY SUPPLIED SENSOR ❑T TEMPERATURE SENSOR 100%OPEN. SEPARATED COMBUSTIO TERMINAL KIT COOLING: FILTER FLOOR SLAB CONTROL DAMPERS CD-2AAND CD-2B SHALL MODULATE OPEN AND CONTROL DAMPER CD-3 SHALL MODULATE CLOSED TO DIFFERENTIAL O TEMPERATURE MAINTAIN COOLING SETPOINT. PRESSURESENSOR SENSOR GAS SUPPLY WHEN DIESEL GENERATOR IS OFF: HUMIDISTAT NG� GAS-FIRED UNIT ❑" THERMOSTAT(T2)SATISFIED:ALL CONTROL DAMPERS SHALL BE FULLY CLOSED. r HEATER s°- DUCT SMOKE DETECTOR u IJI WALL MOUNTED HEATING: GAS COCK c❑ CO2 UNIT HEATER UH-2 SHALL OPERATE TO MAINTAIN HEATING SETPOINT. SENSOR FLEX PIPE COOLING: DUCT MOUNTED CURRENT CONTROL DAMPER CD-4 SHALL GO FULLY OPEN AND EXHAUST FAN EF-1 SHALL RUN TO MAINTAIN COOLING SETPOINT. DIRT LEG NOTE: CO2 TRANSDUCER MAINTAIN CLEARANCE FROM COMBUSTIBLES SENSOR NOTES: PER MANUFACTURERS RECOMMENDATIONS INITIAL THERMOSTAT COOLING SETPOINT SHALL BE 85°F AND INITIAL HEATING SETPOINT SHALL BE 60°F.PROVIDE u CONTROL CONTROLLED AS NOTED IN ABOVE CONTROL SEQUENCE. AIR FLOW RELAY MEASURING STATION CONTROLS- NEW DIESEUGENERATOR ROOM UNIT HEATER DETAIL MANUAL SWITCH 2 N.T.S. N.T.S. DEFINITIONS: Al = ANALOG INPUT AO = ANALOG OUTPUT BI = BINARY INPUT BO = BNARY OUTPUT AV = ANALOG VALUE BV = SINARYVALUE EXTEND THIMBLE ADJ = ADJUSTABLE 9"BEYOND WALL THIMBLE SHALL BE 12" SCH. = SCHEDULE FLASH UP SIDES OF THIMBLE 7RD. = TREND MINIMUM 1/8"W*LDEDRGER IN DIAMETER ALM. = ALARM STAINLESS STEEL CLAMP STEEL THIMBLEN EXAUST PIPE DISP. = DISPLAY MOD = MOTOR OPERATED DAMPER TR EXHAUST PIPE E INSULATION MODIFIED SEQUENCE OF OPERATION FOR EXISTING DIESELIGENERATOR ROOM THERMOSTAT(T71 SATISFIED: _____________ EXHAUST PIPE ALL CONTROL DAMPERS SHALL BE FULLY CLOSED.HEATING: -=UNIT HEATERS EH-1 AND UH-1 SHALL OPERATE TO MAINTAIN HEATING SETPOINT. VVENTILATION COOLING: HOLES IN TOP AND CONTROL DAMPERS(E)CD-1A AND(E)CD-1B SHALL GO FULLY OPEN AND EXHAUST FAN EF-1 SHALL RUN TO MAINTAINPIPE INSULATION BOTTOM PLATES COOLING SETPOINT. SPACERSEXHAUST T X 6"LONG NOTES: TEEL SPACERS INITIAL THERMOSTAT COOLING SETPOINT SHALL BE 85-F AND INITIAL HEATING SETPOINT SHALL BE 60-F. EXTEND THIMBLE PIPE INSULATION WELDED TO 8"BEYOND WALL EXAUST PIPE ESCUTCHEON CONTROLS- EXISTING DIESEUGENERATOR ROOM GENERATOR EXHAUST WALL THIMBLE DETAIL N.T.S. l `J / N.T.S. �i 9 8 AGENCY REVIEW (REVISION 2) JUNE 2025 o VERIFY SCALE! REVISIONS ,. 7�,q DRAWN BY: CMH PROJECT NUMBER NO. DESCRIPTION BY DATE O 10678.001 THESE PRINTS MAYBE BE Cr Morrison 0 9 DSGN.BY: CMH NORTON RANCH LIFT STATION UPGRADES REDUCED.LINE BELOW 2880 Technology Blvd West p JOSEPH R. * SHEET NUMBER m MEASURES ONE INCH ON ■■ Bozeman,MT 59718 G S . APPR.BY: JRH BOZEMAN MONTANA 36 � ORIGINAL DRAWING. Mai e r I e ` 406.587.0721 No.41135 PE o• DATE: 0612025 DRAWING NUMBER ® www.m-m.net �° 7jCENSEO �W� Q.C.REVIEW HVAC DETAILS �_� 8i MODIFY SCALE ACCORDINGLY! engineers•surveyors•planners•scientists PS G BY: JRH PLOTTEDON:5/29120253:27:03PM COPYRIGHT@MORRISON-MAIERLE,2023 S��'M w� N DATE: 1/27/2025